1.Preliminary clinical study on treatment of prostate cancer with Cyber-Knife
Hanjing GAO ; Zhen TAO ; Huanhuan WANG ; Fengtong LI ; Yang DONG ; Xuyao YU ; Jingsheng WANG ; Huaming CHEN ; Yongchun SONG ; Zhiyong YUAN
Chinese Journal of Radiological Medicine and Protection 2019;39(6):415-421
Objective To evaluate the safety and effectiveness of ultra-hypofractionated stereotactic body radiotherapy in the treatment of prostate cancer.Methods A total of 26 patients with prostate cancer treated with Cyber-Knife from May 2010 to May 2018 were analyzed retrospectively.The median age of the patients was 69 years old (range,57 to 87).Ultra-hypofractionated radiotherapy was delivered in five fractions of 7.0-7.5 Gy for a total dose of 35.0-37.5 Gy.Androgen deprivation therapy (ADT) was administered in combination with the Cyber-Knife.The primary endpoints were radiation toxicity,PSA-response,local control and symptom alleviation,while the secondary endpoints were progression-free survival and overall survival.Results No graded ≥ 3 acute and late radiation toxicities occurred during follow-up.The acute toxicity of Grades 1 and 2 was 38.4% and 19.2%,while the late toxicity of Grades 1 and 2 was 30.8% and 3.8%,respectively.At a median follow-up of 22.44 months,for patients with localized stage,PSA level was decreased significantly after radiotherapy (Z =2.900,2.794,2.510,2.090,P<0.05).However,there was no statistically significant difference for the metastatic group (P> 0.05).Conclusions Ultra-hypofractionated stereotactic body radiotherapy is a safe and effective treatment for patients with prostate cancer.
2. Dosimetric comparison of two radiotherapy treatment planning approaches for multiple brain metastases from non-small cell lung cancer on CyberKnife
Xuyao YU ; Zhiyong YUAN ; Fengtong LI ; Yang DONG ; Yongchun SONG ; Xiaoguang WANG ; Ping WANG
Chinese Journal of Radiological Medicine and Protection 2019;39(12):926-930
Objective:
To compare the dosimetrics of the plan target volume (PTV) and organs at risk (OARs) between two treatment planning approaches for patients with multiple brain metastases from non-small cell lung cancer on CyberKnife.
Methods:
20 patients with multiple metastases from lung carcinoma were reviewed and analyzed, who had been treated by CyberKnife from December 2017 to December 2018. The CyberKnife stereotactic radiotherapy plans of the 20 cases were re-planed with single plan for multiple lesions and multiple plans per lesion. The dosimetry differences of PTV and OARs isodose disribution, conformity index (CI), total beam counts and total monitor units (MUs) were compared in the two types of plans.
Results:
The two types of plans could satisfy over 95% PTV coverage of the prescription dose. The maximum and mean dose of normal brain adjacent to the PTV were reduced in multiple plan approach effectively. Moreover, the maximum and mean dose of OARs (brainstem) dropped by 1.62% and 5.57% (
3. Research Progress on Relationship Between Estrogen and Colorectal Neoplasms
Ying WANG ; Xuyao YANG ; Xuan YANG ; Yuemeng CUI ; Shengrun XU ; Jiang CHANG
Chinese Journal of Gastroenterology 2022;27(1):57-61
Colorectal cancer (CRC) is one of the most common clinical malignancies, its morbidity and mortality are still on the rise. Colorectal tumorous polyp is the main precancerous lesion of CRC. The morbidity and mortality of colorectal neoplasms in men are higher than those in women, and exogenous estrogen supplementation can reduce the incidence of CRC in women, which suggests that estrogen may play a protective role in the occurrence and development of colorectal neoplasms. This article reviewed the research progress on the relationship between estrogen and colorectal neoplasms.
4.The effect of task-oriented exercise training on hospitalized elderly diabetic patients
Jin XING ; Xin GU ; Qingmei LIU ; Shijie ZHU ; Ruolin LIU ; Aixin GUO ; Xuyao WANG
Chinese Journal of Geriatrics 2024;43(1):39-44
Objective:To investigate the efficacy, feasibility, and safety of task-oriented exercise training for hospitalized elderly diabetic patients.Methods:This study is a parallel randomized controlled trial with a positive control and a single-blinded assessor.From July 2020 to July 2021, we included 84 elderly patients with type 2 diabetes who were hospitalized in the Department of Endocrinology at Beijing Hospital.These patients were randomly divided into two groups: the task-oriented exercise training group(TOE group)and the regular exercise training group(regular group). The TOE group participants were trained using a task-oriented exercise program that was specifically developed by our research team.On the other hand, the regular group participants were trained using a classical program that comprised of all exercise modes.Each subject received individualized exercise training for 10 consecutive days while staying in the hospital.We evaluated the efficacy, feasibility, and safety of the training programs by measuring the physical fitness of the participants, assessing the feasibility of the program, and monitoring any exercise-related adverse events that occurred.Results:A total of 79 subjects completed the entire intervention and follow-up period, with 40 subjects in the TOE group and 39 subjects in the regular group.In terms of efficacy, both groups showed improvement in their physical fitness indexes after the intervention, with no significant differences in the degree of improvement between the two groups(all P>0.05). When considering feasibility, the TOE group had a higher proportion of prospective feasibility at 87.5%(35 out of 40)compared to the regular group at 71.8%(28 out of 39). Similarly, the TOE group had a higher proportion of practical feasibility at 75.0%(30 out of 40)compared to the regular group at 53.8%(21 out of 39). The TOE group showed a significant advantage in practical feasibility between the two groups( χ2=3.862, P=0.049). As for safety, there were no exercise-related adverse events during the intervention in either group. Conclusions:The efficacy and safety of the task-oriented exercise program for hospitalized elderly diabetic patients is comparable to that of the regular program.Additionally, the task-oriented program is more feasible than the regular program.
5.Verification Phantom-based clinical quality control and detection of the MLC of CyberKnife M6
Xuyao YU ; Yang DONG ; Yuwen WANG ; Zhiyong YUAN ; Xiaolin TIAN ; Zeqian NIU ; Huaming CHEN ; Jingsheng WANG ; Yongchun SONG
Chinese Journal of Radiological Medicine and Protection 2022;42(7):511-515
Objective:To provide a new morning check method for the output dose stability of the multileaf collimator (MLC) of the CyberKnife M6 (CK-M6) system.Methods:The CT images of a verification phantom with a size of 20 cm × 20 cm × 10 cm were transmitted into the Precision Treatment Plan ning System (ver. 1.1.1.1). The high-precision alignment between the accelerator output front and the fixed position of the phantom surface was achieved using the fiducial tracking method. A 10 cm × 10 cm radiation field was formed by the MLC and a DailyCheck plan with an output of 200 MU was designed. The repeatability, sensitivity, and accuracy of the DailyCheck plan were measured, and the CK-M6 system was continuously tested for one month using the artificial fixed method and the DailyCheck plan designed in this study. Results:The average and the standard deviation of 10 repeated measurements by the DailyCheck plan were 492.28 pC and 0.09, respectively, indicating good stability. There was a linear correlation between the measured values and the output dose, with a correlation coefficient of R2 > 0.999. Moreover, there was a position deviation of 2 mm between the phantom and the accelerator output front, and the result ant effect on the measured values was equivalent to a dose deviation caused by an output of 1.24 MU. The result from the continuous measurement of both the artificial fixed method and the DailyCheck plan fell within permissible limits, showing high consistency. Conclusions:The DailyCheck plan established through the fiducial tracking of a verification phantom can achieve the convenient, quick, and accurate daily detection of the output dose stability of the MLC of CK-M6. Therefore, this method can be widely applied in the clinical quality control of the CK-M6 system.
6.A dosimetric analysis of lung tissue in early stage non-small cell lung cancer patients treated by Cyberknife radiotherapy
Jingsheng WANG ; Xuyao YU ; Fengtong LI ; Yang DONG ; Huaming CHEN ; Yongchun SONG ; Zhen TAO ; Zhiyong YUAN
Chinese Journal of Radiological Medicine and Protection 2018;38(12):933-937
Objective To analyze the radiation dose to the normal lung tissue of patients with early stage of non-small cell lung cancer treated by Cyberknife. Methods A retrospective analysis was conducted by summarizing the treatment plans of 264 patients with early stage non-small cell lung cancer from January 2011 to December 2013 in Tianjin Medical University Cancer Institute and Hospital. Sorted by the tumor volumes and locations, the Cyberknife plans were evaluated by means of dose volume histograms ( DVH) , homogeneity indexes ( HI) , percentage volumes receiving at least x Gy ( Vx ) of dose, i. e. , V5 , V10 , V20 , and V30 of the ipsilateral and contralateral lungs. For the tumors approximate to the hilus, the contralateral lungs were included in the optimization process, and the dose-volume metrics were analyzed for the contralateral and bilateral lungs. Results For the tumors close to the chest wall, V5≥(15. 21 ± 3. 12)% in ipsilateral lung tissue and V5≥(1. 34 ± 0. 67)% in contralateral lung tissue were observed. For the tumors near the hilus, V5≥(39. 4 ± 11. 90) % in ipsilateral lung tissue and V5≥(1. 48 ± 0. 34) % in contralateral lung tissue were observed. The irradiated volume ratios of both ipsilateral and contralateral lung tissue increased with the enlargement of tumor sizes. After including the contralateral lung tissue into the optimization, the irradiated volume ratios of the contralateral and bilateral lung tissue (V5,V10) decreasedsignificantly(t=2.44,4.81,3.53,3.17,P<0.05). Conclusions Higherriskof radiation injury in both ipsilateral and contralateral lung tissue can be expected for tumors near the hilus than near the chest wall. After including contralateral lung tissue into the planning optimization, lower dose to the contralateral and whole lung tissue was achieved, indicating a better protection of normal lung tissue.