1.Automated synthesis and quality analysis of 18F-FMISO based on CFN-MPS-100 module
Liping CHEN ; Yu ZHANG ; Najing WU ; Xuyang YOU ; Liang CHENG ; Weixing WAN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2015;35(4):303-305
Objective To synthesize 18F-FMISO and analyze the quality of the product.Methods 1-(2'-nitro-l'-imidazolyl)-2-O-tetrahydropyranyl-O-trluendulfonylpropanediol (NITIT) was taken as the precursor and simple one pot method was used.CFN-MPS-100 fluorine multifunction radiopharmaceutical chemical synthesis module was adopted to complete the radioactive fluorination reaction in a closed flat flask,and the crude product was purified by semi-preparative HPLC,the solvent was removed by rotary evaporation.Then 15 ml saline was added into the product to get 18F-FMISO injection.Radio-HPLC and radio-TLC were applied for quality control.Results 18F-FMISO was obtained in 60 min with the radiochemical yield of (32±5.0)% (no decay corrected,n=25).The radiochemical purity was above 99.0% and still above 98.5% after 6 h.The radioactive concentration was above 1.11 × 1012 Bq/L.The product was colorless solution,with pH value of 7.0.The radioactive nuclear purity was more than 99%.The K222 was less than 25 μg/ml.Conclusion 18 F-FMISO could be synthesized with automatic synthesis method based on the CFN-MPS-100 fluorine multifunction module.The labeling rate,stability and chemical purity are high.
2.Characteristics and diagnostic value of temporal retinal thinning in young patients with Alport syndrome
Liang ZHAO ; Ruilin ZHU ; Xuyang YAO ; Jia XIE ; Yanqin WANG ; Fang WANG ; Jie DING ; Liu YANG
Chinese Journal of Ocular Fundus Diseases 2019;35(2):176-180
Objective To observe the features of temporal macular thinning and its value for the diagnosis of Alport syndrome (AS) in young patients.Methods Eighty-one young patients with AS (81 eyes) from Peking University First Hospital during January 2016 and July 2017 were included in this study.There were 67 males (67 eyes) and 14 females (14 eyes),the aged from 3 to 17 years,with the mean age of 9.6 years.Among 81 patients (81 eyes),there were 64 patients with X-linked AS (XLAS,including 53 males and 11 females),17 patients with autosomal recessive AS (ARAS,including 14 males and 3 females).One hundred healthy subjects aged 4 to 17 years were included as controls.Clinical data were retrospectively evaluated,including visual acuity,slit-lamp microscopy,dilated fundus photography,and OCT.Retinal thickness was measured with an OCT scan and the temporal thinning index (TTI) was calculated as stated in a previous study.The TTI values of each group was compared by One-way ANOVA or independent sample t test.The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic effectiveness for AS.Results The TTI of the control group,XLAS and ARAS patients were 6.46 ± 1.58,10.93 ± 3.77,12.14± 4.05,respectively.Compared with the control group,the TTI value of males were larger in the XLAS and ARAS group (F=45.056,P<0.001),the TTI value of females were larger in the ARAS group (F=26.541,P<0.001).The difference of TTI value in females was significant between the XLAS and ARAS groups (F=26.541,P<0.001).In males,the area under the ROC curve was 0.896 (95%CI 0.837-0.955,P<0.001).The optimal cutoff value of the TTI was determined as 9.47,with a sensitivity of 73.1% and a specificity of 100%.Conclusions TTI is a common ocular finding in young patients with AS.In males,a TTI > 9.47 may differentiate AS from normal males.
3.Analysis of macular microstructure and visual function based on morphological closure of idiopathic macular hole after inverting internal limiting membrane flap
Ying WANG ; Xuyang YAO ; Dongqing LIANG ; Yuyan LIU ; Quanhong HAN
Chinese Journal of Ocular Fundus Diseases 2020;36(5):374-378
Objective:To observe the healing morphology, macular microstructure and visual function of idiopathic macular hole (IMH) after pars plana vitrectomy (PPV) combined with internal limiting membrane (ILM) flap.Methods:Retrospective case study. From 2016 to 2018, 39 eyes of 39 patients with IMH diagnosed in Tianjin Eye Hospital were included in the study. Among them, there were 4 eyes in 4 males and 35 eyes in 35 females, with an average age of 64.56±7.2 years. BCVA, OCT, OCT angiography (OCTA) and MAIA microperimetry examination were performed in all patients. BCVA examination was performed with the international standard visual acuity chart, which was converted to logMAR visual acuity when recording. All patients underwent PPV combined with ILM flap covering and air tamponade. According to the characteristics of OCT images postoperatively, the eyes were divided into U-shaped closed group, V-shaped closed group, irregular closed group and flat closed group, with 26, 5, 7 and 1 eyes respectively. There was a significant difference in the minimum hole diameter ( F=5.118, P=0.005) and macular hole classification ( F=3.608, P=0.024). The shallow capillary layer (SCP) blood flow density in the U-shaped closure group was significantly higher than that in the V-shaped closure group, the irregular closure group and the flat closure group (t=2.079, 2.368; P=0.047, 0.025). At 1, 3, 6 months after the operation, the same equipment and methods were used for relevant examination. The blood flow density of BCVA, SCP, perimeter of foveal avascular zone (PERIM) and mean sensitivity (MS) were compared before and after operation. Independent sample t-test was used for quantitative data comparison between different groups, and χ2 test was used for counting data comparison. Results:Six months after operation, the logMAR of the eyes in the U-shaped closure group was -0.75±0.29 higher than that before operation, and was better than that in the V-shaped closure group, the irregular closure group and the flat closure group ( t=-2.974, -2.518; P=0.006, 0.018). The integrity of external limiting membrane (ELM) and ellipsoid in U-shaped closed group was significantly higher than that in V-shaped closed group, irregular closed group and flat closed group ( χ2=15.229, 10.809; P=0.020, 0.013). The percentage of macular central fovea reflex mass in the U-shaped closed group was significantly lower than that in the V-shaped closed group, irregular closed group and flat closed group ( χ2=20.107, P=0.000). PERIM in U-shaped closure group was smaller than that in V-shaped closure group, irregular closure group and flat closure group, and the difference was statistically significant ( t=-3.391, -2.427; P=0.002, 0.022). The total MS of macular area 10° in the U-shaped closure group was significantly higher than that in the other V-shaped closure group, irregular closure group and flat closure group ( t=2.939, 2.811; P=0.001, 0.001). Conclusion:After IMH operation, the U-shaped closure showed better BCVA and macular light sensitivity, the proportion of ELM and ellipsoid to restore structural integrity are higher, PERIM is smaller, and there are fewer macular fovea strong reflex masses.
4.Application of traction with titanium clips in endoscopic submucosal dissection for large laterally spreading tumor in rectum and sigmoid colon
Ling REN ; Shuxian ZHANG ; Kun WANG ; Lu WANG ; Xuyang LIANG ; Chenyan ZUO ; Zhimei ZHANG ; Yunliang SUN ; Shengxiang LÜ
China Journal of Endoscopy 2024;30(6):30-36
Objective To investigate the advantages and efficacy of traction with titanium clips in endoscopic submucosal dissection(ESD)for large laterally spreading tumor(LST)in rectum and sigmoid colon.Methods 67 patients with large sigmoid or rectal LST underwent ESD from January 2018 to June 2022 were analyzed retrospectively,including 32 patients in Group A and 35 patients in Group B.Group A was treated with clip-line traction and group B was treated with traditional ESD.The size of lesion,the total operation time,the submucosal dissection time,submucosal dissection rate,submucosal injection number,en bloc resection rate,R0 resection rate,curative resection rate and complications of the two groups were compared.Results LST-G-M was the most common type and villous adenoma was the main pathology in both groups.There were no differences in en bloc resection rate,R0 resection rate and incidence of complications between the two groups.The average size of group A was(13.6±8.4)cm2,significantly larger than that in group B(9.3±4.7)cm2,the total operation time was(42.3±10.3)min in group A,significantly shorter than that in group B(47.9±10.1)min,submucosal dissection time was(30.7±8.2)min in group A,significantly shorter than that in group B(36.1±7.6)min,submucosal injection number was(2.7±1.1)times in group A,significantly less than that in group B(3.5±1.2)times,submucosal dissection rate was(0.4±0.2)cm2/min in group A,significantly faster than that in group B(0.2±0.1)cm2/min,the differences were statistically significant(P<0.05).Conclusion Compared with traditional ESD,clip-line traction can provide a better surgical field and more effective dissection for large LST in rectum and sigmoid colon.