1.Determination of triclocarban and triclosan in urine by QuEChERS extraction and ultra-performance liquid chromatography-tandem mass spectrometry
Qiaoli QIU ; Xiaohong CHEN ; Shanshan YAO ; Xunping YAO ; Lanyun FANG ; Micong JIN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(1):46-49
Objective:To establish a method for the determination of triclocarban (TCC) and triclosan (TCS) in urine by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) after purification by QuEChERS.Methods:In May 2022, urine samples were extracted by acetonitrile, purified by QuEChERS, separated by Waters Acquity UPLC BEH C18 column (100 mm×2.1 mm, 1.7 μm), and eluated with water-acetonitrile as mobile phase gradient at a flow rate of 0.3 ml/min. The detection was conducted in negative ion mode (ESI -) and multiple reaction monitoring (MRM) scanning, it was quantified with a internal standard method, and the methodology was verified. Results:The linear ranges of TCC and TCS were 0.5-100.0 μg/L and 1.0-100.0 μg/L, and the correlation coefficients were 0.9997 and 0.9991, respectively. The limits of detection and quantitation of TCC and TCS were 0.17 and 0.33 μg/L, and 0.5 and 1.0 μg/L, respectively. The recoveries of TCC and TCS were 100.1%-102.8% and 96.7%-108.6%, and the relative standard deviations were 4.9%-6.7% and 4.1%-8.3%, respectively, at 2.0, 10.0 and 80.0 μg/L.Conclusion:QuEChERS-UPLC-MS/MS method is simple, rapid, sensitive and reproducible, and can be used for rapid and accurate simultaneous detection of TCC and TCS exposure levels in occupational population.
2.Determination of triclocarban and triclosan in urine by QuEChERS extraction and ultra-performance liquid chromatography-tandem mass spectrometry
Qiaoli QIU ; Xiaohong CHEN ; Shanshan YAO ; Xunping YAO ; Lanyun FANG ; Micong JIN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(1):46-49
Objective:To establish a method for the determination of triclocarban (TCC) and triclosan (TCS) in urine by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) after purification by QuEChERS.Methods:In May 2022, urine samples were extracted by acetonitrile, purified by QuEChERS, separated by Waters Acquity UPLC BEH C18 column (100 mm×2.1 mm, 1.7 μm), and eluated with water-acetonitrile as mobile phase gradient at a flow rate of 0.3 ml/min. The detection was conducted in negative ion mode (ESI -) and multiple reaction monitoring (MRM) scanning, it was quantified with a internal standard method, and the methodology was verified. Results:The linear ranges of TCC and TCS were 0.5-100.0 μg/L and 1.0-100.0 μg/L, and the correlation coefficients were 0.9997 and 0.9991, respectively. The limits of detection and quantitation of TCC and TCS were 0.17 and 0.33 μg/L, and 0.5 and 1.0 μg/L, respectively. The recoveries of TCC and TCS were 100.1%-102.8% and 96.7%-108.6%, and the relative standard deviations were 4.9%-6.7% and 4.1%-8.3%, respectively, at 2.0, 10.0 and 80.0 μg/L.Conclusion:QuEChERS-UPLC-MS/MS method is simple, rapid, sensitive and reproducible, and can be used for rapid and accurate simultaneous detection of TCC and TCS exposure levels in occupational population.