1.Comparison of rectal cancer tumor volume parameters measured by MRI sequences and CT with those by pathological specimen
Yuanyuan LIU ; Suyu ZHU ; Xiaoyan CHEN ; Lu WEN ; Jinjiao LI ; Xujie BAO ; Jumei ZHOU ; Shaolin NIE
Chinese Journal of Clinical Oncology 2017;44(13):656-661
Objective:This study aimed to compare rectal cancer tumor volume parameters measured by MRI sequences (T1WI, T2WI, and DWI) and/or CT with those by pathological specimen. Methods:Twenty-two patients with rectal cancer were prospectively enrolled. MRI sequences including T1WI, T2WI, and DWI, and/or CT of the pelvis were performed before operation. Volume parameters, such as tumor length along the rectal axis, maximum tumor width perpendicular to rectal axis, and tumor actual area in that perpendicular plane, were measured on T1WI, T2WI, DWI, and CT, respectively, for each patient. The respective pathological parameters were further measured in surgical specimen after total mesorectal excision. The two kinds of parameter values measured in imaging and pathology were statistically compared and accuracy appraisal was performed. Results:The mean Lpath-L was 4.06±1.14 cm. The mean LT1-L, LT2-L, LDWI-L, and LCT-L were 3.91± 1.51, 4.62±1.41, 3.39±1.05, and 3.94±1.23 cm, respectively. Correlation coefficients were 0.688, 0.635, 0.688, and 0.720 (P<0.05). An average 6 mm overestimation was found in T2WI, and 1 to 6 mm underestimation in T1WI, DWI, and CT in length values compared with those measured in surgical specimen. The mean Lpath-W was 2.56 ±0.94 cm. The mean LT1-W, LT2-W, LDWI-W, and LCT-W were 3.62±0.99, 3.66±0.76, 3.23±0.58, and 3.64±1.04 cm, respectively. The magnitude of mean overestimation ranged from 5.1 to 11.1 mm. The Apath was 4.30 ±2.83 cm2. AT1, AT2, ADWI, and ACT were 8.98±3.90, 8.99±3.43, 8.41±3.09, and 9.63±4.40 cm2, respectively, which double overestimated the tumor area in the perpendicular rectal plane. Conclusion:The difference in longitudinal length between MRI sequences/CT and pathological specimen was in the range of?6 mm to 6 mm. The mean maximum tumor width and areas in the maximum tumor perpendicular plane were overestimated. This study indicated that gross tumor volume delineation based on CT or MRI for rectal cancer irradiation should be conservative in the axial images of rectum, and meticulous consideration is required along the rectum.
2. Improve the effect of nurses on the occupational protection of cytotoxic drugs
Huiling BAO ; Jianhong NING ; Xujie ZHAO
Chinese Journal of Industrial Hygiene and Occupational Diseases 2019;37(3):210-212
Objective:
Evaluation of improving the occupational protective effect of nurses in cytotoxic drugs.
Methods:
The occupational hazards of cytotoxic drugs in Qingdao Central hospital were taken as samples. Compare the occupational hazards of cytotoxic drugs before and after improvement.
Results:
From Sept.2017 to Aug.2018, the number of occupational hazards of cytotoxic drugs decreased by 90.38%; Sharp injuries, drug spillovers, distribution errors and excessive air diffusivity were decreased by 70%~100%.
Conclusion
Targeted occupational protection can significantly reduce the hazards of cytotoxic drugs and ensure the health of the medicinal staff.
3.Measurement of the distance of microfoci from a rectal gross tumor in a pathological specimen
Xujie BAO ; Suyu ZHU ; Xiaoyan CHEN ; Ke LIU ; Jumei ZHOU ; Zheng WU ; Yuanyuan LIU
Chinese Journal of Clinical Oncology 2019;46(8):406-411
Objective: To measure the distance of the lateral, inferior, and superior microfoci from a gross tumor in a pathological speci-men and to provide scientific evidence for margin extension to form the clinical target volume (CTV) in high-dose radiotherapy for rec-tal cancer. Methods: Twenty-eight surgical specimens were collected from patients with rectal cancer who underwent total mesorectal excision (TME) in Hunan Cancer Hospital between October 2016 and April 2017. The nearest distance of the farthest peripheral micro-foci from the gross tumor was measured. The in vivo-in vitro tumor retraction factor (R1) was calculated by measuring the ratio of the tumor's perpendicular depth based on magnetic resonance imaging and immediate surgical specimens. The retraction factor (R2) in the process of pathological specimen makeup was calculated by knot labeling. The distance of microfoci extension was calculated based on that measured in pathological specimens including corrections with R1 and R2 and record as microcarcinoma extension mea-sured in vivo,MEin vivo. Results: Among the 28 pathological specimens, lateral, inferior, and superior microfoci were found in 17 (60.7%), 3 (10.7%), and 0 cases, respectively. The mean R1 was 0.913 and mean R2 was 0.803. The farthest distance measured inferiorly was 28 mm in vivo after correction. The maximum, minimum, and mean measured lateral distances were 12.03 mm, 3.03 mm, and 7.50 mm after correction, respectively. The 95% frequency value was within 10 mm. Conclusions: The lateral microfoci extension was within 10 mm for 95% of the rectal cancer patients. The margin expansion to form the CTV was suggested to be 10 mm for a late-course boost of high-dose radiotherapy for rectal cancer.
4.Nephrotic syndrome associated with coenzyme Q10 deficiency due to coenzyme Q2 gene mutation: a case report
Daorina BAO ; Hongyu YANG ; Fang WANG ; Xujie ZHOU ; Xin ZHANG ; Suxia WANG ; Fude ZHOU
Chinese Journal of Nephrology 2023;39(2):138-141
The paper reports a case of coenzyme Q10 deficiency nephrotic syndrome associated with coenzyme Q2 gene mutation and reviews the literature on this topic. The patient presented with hematuria, proteinuria, and a diminution of vision as clinical manifestations. But the proteinuria was not relieved after sufficient doses of glucocorticoids for over 2 months. The patient′s birth history was unremarkable, and his parents were both healthy and not consanguineous. Whole exome sequencing revealed that the patient had a mutation of coenzyme Q2 gene at c.973A>G(p.T325A) and c.517C>T(p.R173C). Combined with renal biopsy pathology, the patient was diagnosed with hereditary nephropathy and started the supplements of coenzyme Q10 after stopping glucocorticoid treatments immediately. After 5 weeks of therapy, the patient′s 24-h urine protein quantification decreased from 6.01 g to 1.53 g.