1.The influence of different nifedipine types on the blood pressure variability
Xuelei WANG ; Zhongchao CAO ; Ye GAO ; Yang JIN ; Fangyi MA ; Dali TIAN ; Guifen FU
Chinese Journal of Postgraduates of Medicine 2006;0(27):-
Objective To observe the influence of the short effect antihypertension drugs- nifedipine and medial effect antihypertension drugs- extended release nifedipine on the blood pressure variability (BPV) in essential hypertension(EH). Methods Twenty-five EH patients were underwent 24-hour noninvasive ambulatory blood pressure monitoring (ABPM) and observed their BPV respectively before taking drugs, after taking nifedipine and extended release nifedipine. Meantime,25 normotensive controls (NC) were observed. Results (1)BPV in EH group was higher than that in controlled group and the severer the rise of blood pressure, the more obvious the increase of BPV (P 0.05). Conclusions Nifedipine could increase BPV but extended release nifedipine did not change BPV while they decreased blood pressure. Effect of extended release nifedipine was better than nifedipine in decreasing blood pressure.
2.Reactive protein, plasminogen activator inhibitor type-1 (PAI-1) levels, PAI-1 promoter 4G/5G polymorphism and acute myocardial infarction
Xuelei CAO ; Changyong ZHOU ; Lei YIN ; Shaochun WANG ; Xiuling JIA ; Huan HUANG ; Xiaohong SUN
Journal of Geriatric Cardiology 2010;07(3):147-151
Objective To investigate the relationship between CRP, plasminogen activator inhibitor type 1 (PAI-1) levels, PAI-1 gene promoter 4G/5G polymorphism and the type of acute myocardial infarction (ST elevation myocardial infarction, STEMI vs the non-ST elevation Myocardial infarction, NSTEMI). Methods One hundred seventy-six consecutive patients with AMI were included for the study, of whom 60 had STEMI and 56 had NSTEMI, and 60 adults without cardiovascular and cerebrovascular disease were selected as controls. Blood samples were obtained from patients within 6 h of AMI and the plasma PAI-1, CRP, and the gene polymorphism were measured. Results Plasma levels of PAI-1 and CRP were higher in AMI groups, compared those in the control group, and plasma levels of PAI-1 were significantly higher in patients with STEMI compared to those with NSTEMI (80.12ng/ml VS.73.01ng/ml, P <0.01), while CRP levels were not significantly different between patient with STEMI and NSTEMI (3.87±0.79 mg/ml VS.4.01±0.69mg/ml, P>0.05). PAI-1 levels presented a significant correlation with CRP levels in the NSTEMI subjects. However, PAI-1 and CRP levels could explain the lack of a significant relationship between them in control and STEMI subjects.The frequencies of 4G/4G genotype in the AMI group were higher than those in the control group and higher in patient with STEMI than in patient with NSTEMI. Plasma levels of PAI-1 in subjects with 4G/4G genotype were significantly increased as compared to those in subjects with 4G/5G and 5G/5G genotype. Conclusions Plasma PAI-1 levels were associated with different myocardial infarction type, and PAI-1 promoter 4G/5G polymorphisms and CRP may be related to plasma PAI-1 levels.
3.Clinical Observation of Compound Artemisiae Rupestris Granules Plus Other Traditional Chinese and Western Medicines in Treatment of Viral Myocarditis
Liangzhen TU ; Xuelei YANG ; Limeng CAO ; Jianguo XU ; Fangming GAO ; Jinsheng WU ; Liya WU ; He SUN ; Bin ZHANG
China Pharmacy 1991;0(04):-
0.05) but there was significant difference between CARG group and control group(P
4.Establishment and Application of dose evaluation model for typical mammal in dry region in China
Han YUAN ; Wenjing GONG ; Xuelei HAN ; Shaofei CAO ; Jianguo LI
Chinese Journal of Radiological Medicine and Protection 2022;42(10):793-798
Objective:To establish a simplified anatomical model with the selected rabbits widely distributed in China′s dry region as the reference species and compare the result of internal exposure dose coefficients based on the present mode and ERICA.Methods:A simplified anatomical model based on anatomy and geometry was established for rabbits. Combined with Monte Carlo program, the deposited energy of radionuclide particles in rabbit tissues/organs was obtained, and the internal and external exposure dose coefficient for rabbits was calculated following the empirical formula.Results:Simplified anatomy model-based dose coefficients were 129I 4.81 × 10 -6, 137Cs 4.34 × 10 -5, and 134Cs 3.81 × 10 -5(μGy·h -1)/(Bq·kg -1) for internal exposure and 129I 3.16 × 10 -7, 137Cs 2.39 × 10 -4 and 134Cs 6.22 × 10 -4(μGy·h -1)/(Bq· kg -1) for external exposure. respectively. ERICA-based dose coefficients were 129I 4.44 × 10 -5, 137Cs 1.94 × 10 -4 and 134Cs 2.34 × 10 -4(μGy·h -1)/(Bq·kg -1) for internal exposure and 129I 2.19 × 10 -6, 137Cs 2.52 × 10 -4 and 134Cs 6.95 × 10 -4(μGy·h -1)/(Bq·kg -1) for external exposure, respectively. Conclusions:The simplified anatomical model established is based on the measured data and focuses on the radiation doses to biological tissues/organs, and the calculated result based on the present model are closer to the actual situation, and can provide reference values for the reference biological evaluation of non-human species.
5.Stability of temperature field in blood refrigerated warehouse using micro-hole air inlet
Xingzhi CHEN ; Yunguang CHEN ; Xuelei CAO ; Deyuan WANG ; Jiewang XU ; Xiaolian PAN
Chinese Journal of Blood Transfusion 2022;35(9):991-995
【Objective】 To study the effect of air inlet modes on the temperature variation, fluctuation, uniformity and coefficient of variation(CV), so as to evaluate the stability and uniformity of the temperature field in refrigerated warehouse for blood. 【Methods】 The temperature changes of blood refrigerated warehouse under different modes of air inlet during compressor operation were analyzed. The stability of the temperature field in the storehouse was evaluated by the changes, fluctuation, uniformity, CV and deviation of temperature at each testing point. 【Results】 The average value of temperature in the storehouse, adopting air inlet via straight blow, was (4.98±0.92)℃, while that of air inlet via micro-hole mode was(4.15±0.25)℃, with significant differences between each other(P<0.05). As to the CV of temperature, air inlet via straight blow was significantly different from that via micro hole(P<0.01). The fluctuation, uniformity and deviation of temperature created by straight blow and micro hole were 1.85±1.11 vs 0.49±0.38, 1.00±0.68 vs 0.47±0.37, and 0.61±0.45 vs 0.27±0.21, respectively, with significant differences between each other(P<0.01). 【Conclusion】 Compared with straight blow, the mean temperature created by micro hole was closer to the median value (4℃) of the temperature range, i. e.(4±2)℃, during blood storage. Otherwise, micro hole demonstrated a smaller CV of temperature, and superior performance in fluctuation, uniformity and deviation of the temperature at the testing points, which was conducive to ensure the stability of storehouse temperature field.