1.On the Application of TCM Theory of Constitution in P.E.
International Journal of Traditional Chinese Medicine 2008;30(2):126-127,129
This paper traced and reviewd the TCM theory of constitution and its application in school P. E.,and put forwards that this theory had broad applicating prospects in terms of evaluating constitutional health,explaining essential relation between TCM constitutional types and sub-health condition,establishing the means and measures of transforming the biased TCMC of non-traditional EE into normal constitution,classifying students into different levels based on their constitution,cultivating students to preserve their health by using TCM theory,and choosing the athletes scientifically.
2.Re-Examination of Ethical Dilemma of the Intervention of Social Work in Localization of Elderly Hospice Care Service
Bo LIU ; Xin TONG ; Xuekai LIU
Chinese Medical Ethics 2018;31(6):745-748
Social work as one type of practical work for pursuing moral practice,ideology and social value play an important restraint role in its professional ethical choice. In the work of social work intervened in the service of elderly dying patients, the realization of owner' s right is subject to institutional regulation, disputes of family interest, conflicts of social value and the alienation of ethical environment, causing that social workers fall into an ethical dilemma in practice. In order to solve this ethical dilemma, medical social workers can work together to reshape the construction of a new ethical system for elderly hospice care by strengthening their own guiding ability, promoting the education of ethics and optimizing the environment of ethical choice.
3."Leukocyte differential count in peripheral blood ""with"" single tube/ten colors""flow cytometry"
Xuekai LIU ; Jianzhong WANG ; Ying XING ; Chenxue QU ; Chengwei PU ; Ping WU ; Hui WANG ; Kangyuan LIU ; Lan MA ; Na PAN
Chinese Journal of Laboratory Medicine 2011;34(5):395-402
Objective To explore the values of potential clinical application ofsingle tube/ten colorsflow cytometry for leukocyte differential count in peripheral blood.Methods Utilizing multiple monoclonal antibody combinations and the vavious logical gating strategies,the single tube/12 antibodies with no-wash method for the leukocyte differential count in peripheral blood were determined by using 10 colors flow cytometry.Leukocyte differentials of 142 peripheral blood samples were determined by both Beckman-Coulter LH750 hematology analyzer and 10 colors flow cytometry.The results were then compared to standard microscopic examination as a reference method.The clinical diagnostic efficiency ofsingle tube/10 colorsflow cytometry was calculated.The correlations between standard microscopic cytology,single tube/10 colorsflow cytometry and the hematology analyzer were determined.In addition,the clinical diagnosis efficiency for blast counts ofsingle tube/10 colorswere compared to the results determined by BD FACS Calibur flow cytometer.Results The leukocyte differentials were correlated well between the single tube/10 colorsflow cytometry and standard microscopic cytology(r>0.700,P<0.01) except for basophils.The correlations with neutrophilic granulocytes,lymphocytes,immature granulocytes and blasts were superior(r=0.972,0.951,0.801,0.912,respectively,P<0.01).When 1% was selected as the cut-off point for immature granulocytes determined by standard microscopic cytology,the sensitivity and the specificity ofsingle tube/10 colorsflow cytometry were 92%(57/62) and 79% (63/80),respectively.When 0.5% was selected as the cut-off point for blasts detected by standard microscopic cytology,the sensitivity and the specificity were 99% (67/68) and 92% (68/74).Using the immunophenotyping results from BD FACS Calibur as a standard,the sensitivity for detecting blasts bysingle tube/10 colOrsflow cytometry was 100% (40/40),the specificity was 91% (10/11),the positive predictive value was 98% (40/41),the negative predictive value was 100% (10/10) and the accuracy was 98% (50/51).Conclusions Thesingle tube/10 colorsflow cytometry has a excellent correlation with the standard microscopic cytology when applied on leukocyte differential count in peripheral blood.It may potentially use as a subsequent method for verification of abnormal results of complete blood cell count in the future.
4.Evaluation for clinical application of UniCel DxH 800 hematology analyzer
Chengwei PU ; Ke SHANG ; Jianzhong WANG ; Xuekai LIU ; Ying XING ; Xiaoling TANG ; Hui GAO ; Ning DONG ; Huiqing SU ; Xiufen MING
Chinese Journal of Laboratory Medicine 2012;35(7):643-646
ObjectiveTo evaluate the improvement on test performance of UniCel DxH 800 automated hematology analyzer for complete blood count (CBC) by detecting its performance indicators and comparing the differences of the results with LH 750 hematology analyzer and ADVIA 2120 hematology analyzer.MethodsThe precision,carryover and linearity of UniCel DxH 800 in measurement of CBC were evaluated by using fresh blood samples and instrument quality control of products.To evaluate the accuracy of leukocyte differential count and reticulocyte count with the microscopic method as the “gold standard”.To calculate the bias and correlation between the results measured by LH 750,ADVIA 2120 and UniCel DxH 800 hematology analyzers and compare these three instruments on the validity of the alarm in abnormal cells.ResultsIntra-precision:The coefficient of variation (CV) of the results of RBC,Hb and MCV were less than 0.5%,the CV of WBC and PLT results were less than 1.5%.Inter-precision:the CV of the parameters above were less than 2.5%.The carryover rate of WBC,RBC,Hb,MCV and PLT were less than 0.51%.In the concentration range covered by clinical samples,the correlation coefficients between the measured values and theoretical value in testing WBC,RBC,Hb and PLT were greater than 0.999 ( P <0.01 ).The measurement results of WBC,RBC,Hb,MCV and PLT hy UniCel DxH 800,ADV1A 2120 and LH 750 hematology analyzers have good correlation (r > 0.973,P < 0.01 ).Correlation of reticulocyte count between the UniCel DxH 800 hematology analyzer and microscolpic method was significant (r =0.920,P <0.01 ).Correlation of leukocyte differential count about the grauulocytes, lymphocytes and eosinophils between the UniCel DxH 800 hematology analyzer and microscopic method was good (r =0.914,0.900 and 0.725,P <0.01 ),followed by monocytes ( r =0.612,P <0.01 ),which were better than the LH 750 with similar detection principle.The UniCel DxH 800 hematology analyzer demonstrated higher sensitivity (96.6% ) for the alarm of abnormal cells and achieved a lower false-negative rate (2.5% ).Meanwhile,the sensitivity of the neutrophil nuclei left shift was higher (90.5% ) and the false-negative rate (5.0%) was lower.ConclusionsThe UniCel DxH 800 hematology analyzer for complete blood count shows advantages of high precision,low carryover rate and wide linear range.The results detected by the UniCel DxH 800 hematology analyzer have good correlation with the LH 750 and ADVIA 2120.
5.Clinical application of 3D printing-assisted extracorporeal fenestration in TEVAR surgery
Zhiyong WU ; Jincheng HOU ; Xuekai LIU ; Jingyuan WEN ; Rui HU ; Yongle RUAN
Chinese Journal of Thoracic and Cardiovascular Surgery 2022;38(10):586-589
Objective:To investigate the effectiveness and feasibility of 3D printing-assisted extracorporeal fenestration techniques in thoracic aortic endoluminal repair.Methods:Retrospectively analyzed the clinical data of patients who underwent endovenous repair of the thoracic aorta with the application of 3D printing technology-assisted extracorporeal windowing in the Department of Cardiovascular Surgery, Wuhan University Hospital from January 2019 to May 2021, and analyzed the surgical results as well as the occurrence of perioperative complications.Results:A total of 10 patients with a mean age of(53.3±15.7) years were included, including 4 cases of complex B aortic coarctation, 5 cases of thoracic aortic aneurysm and 1 case of abdominal aortic aneurysm. All patients in this group underwent endoluminal repair of the thoracic aorta with 3D printing assisted extracorporeal fenestration, including 1 case of PCI performed at the same time. There were no postoperative complications and no perioperative deaths.Conclusion:3D printing technology assisted extracorporeal fenestration and endoluminal aortic repair can accurately position aortic stents for fenestration, optimise endoluminal treatment options and improve patient prognosis.