1.Relationship between the expression of Toll-like receptor 4 on mononuclear cells in peripheral blood and changes of serum vitamin D level in children with bronchiolitis
Kui WU ; Beifang YUAN ; Xuejing HOU ; Chao LI ; Lihong REN
Chinese Journal of Applied Clinical Pediatrics 2015;30(12):938-940
Objective To investigate the relationship between the expression of Toll-like receptor 4 (TLR4) on mononuclear cells in peripheral blood and changes of serum vitamin D level in children with bronchiolitis.Methods The children who were diagnosed as bronchiolitis and received treatment in the Second Affiliated Hospital of Harbin Medical University from October 2013 to January 2014 were chosen as the pre-treatment group,and then divided them into moderate group and severe group according to the clinical symptoms,20 cases for each group.Then the cases in pre-treatment group who recovered after treatment were recruited as the after-treatment group,and the children who were healthy and medical examination in the Second Affiliated Hospital of Harbin Medical University in the same period were recruited as the healthy control group.The expressions of TLR4 on CD14 labeled mononuclear cells in the periphera were measured by flow cytometry.The level of 25 (OH) D in serum was detected by enzyme linked immunosorbent assay (ELISA).Results (1) The expression level in children with bronchiolitis of TLR4:the mode-rate group [(18.98 ±2.29)%] and severe group [(30.13 ±2.13)%] increased significantly (P <0.05) compared with control group [(1.17 ± 0.57) %].And the expression level of moderate group [(2.02 ± 0.48) %] and severe group [(11.43 ± 1.52) %] decreased significantly after treatment (P <0.05).(2) Serum vitamin D level in children with bronchiolitis of the moderate group[(17.16 ± 3.34) μg/L] and severe group [(6.56 ± 2.28) μg/L] were lower than healthy control group [(53.69 ± 20.18) μg/L] before treatment (P < 0.05),especially the severe group [(6.56 ±2.28) μg/L].The level of moderate group [(9.59 ± 2.31) μg/L] and severe group [(4.70 ± 0.67) μg/L] became lower after treatment (P < 0.05).(3) Both severe group (r =-0.491,P < 0.05) before treatment and moderate group (r =-0.436,P < 0.05) after treatment showed negative correlation between TLR4 on mononuclear cells in peripheral blood and serum 25 (OH)D level in children with bronchiolitis.And no correlation was found among healthy control group,moderate group before treatment and severe group after treatment (P > 0.05).Conclusions The conditions of children with bronchiolitis was positively correlated with the expression level of TLR4,and negatively correlated with the vitamin D level.The serum 25 (OH) D decreased steadily during the treatment.The expression of TLR4 in monocytes has a certain correlation with the level of vitamin D in children with bronchiolitis.
2.Study on neurogenic bladder-induced renal fibrosis based on AngⅡ/TGF-β1/Smads signaling pathway
Yan ZHENG ; Yuan MA ; Xuejing REN ; Peiyuan NIU ; Lei YAN ; Huixia CAO ; Fengmin SHAO
Chinese Journal of Nephrology 2021;37(12):1001-1007
Objective:To establish a rat model of neurogenic bladder and analyze the changes in kidney morphology and function and the expression of proteins in AngiotensinⅡ(AngⅡ)/transforming growth factor β1 (TGF-β1)/Smads pathway.Methods:Sprague-Dawley rats were randomly divided into experimental group (spinal nerve amputation, n=36) and control group (sham operation, n=12). At 6, 12, and 24 weeks, the bladder compliance was measured by cystometry, the kidney morphology was detected by B-ultrasound, blood urea nitrogen (BUN) and serum creatinine (Scr) in blood samples were examined, the kidney pathological changes were detected by Masson and HE staining, the distribution of AngⅡ/TGF-β1/Smads pathway proteins was analyzed by immunohistochemisty, and the protein expressions in kidney were detected by Western blotting. Results:Urodynamics showed that the basic bladder pressure in experimental group was higher than that in control group. B-ultrasound showed that compared with the control group, the diameter of the renal pelvis of the rats with nerve dissection gradually increased ( P<0.05), and the hydronephrosis was gradually obvious. Compared with the control group, the BUN and Scr in experimental group gradually increased (both P<0.01). Masson and HE staining showed that compared with the control group, the collagen expression and renal tubulointerstitial scores in experimental group were gradually increased (both P<0.01). Immunohistochemisty showed that compared with the control group, in experimental group the expression of angiotensinⅡ receptor type 1 (AT1), TGF-β receptor 1(TGF-βR1), phosphorylated Smad2 gradually increased (all P<0.01), the pathway inhibitor Smad6 gradually decreased ( P<0.01), and the distribution of each protein in kidney was consistent. Western blotting showed a corresponding expression trend with immunohistochemisty. Conclusions:In neurogenic bladder caused by bilateral spinal nerve amputation, due to bladder dysfunction, increased bladder pressure induces hydronephrosis, destruction of the nephron structure, activation of AngⅡ/TGF-β1/Smads pathway, and renal fibrosis. This method is effective and has clinical similarities, laying a foundation for exploring neurogenic bladder treatment.
3.Value of urine HSP-70 in early diagnosis of acute kidney injury after cardiopulmonary bypass
Huixia CAO ; Xuejing REN ; Lina ZHANG ; Limeng WANG ; Xiaojing JIAO ; Lei YAN ; Leiyi YANG ; Fengmin SHAO
Chinese Journal of Nephrology 2020;36(4):294-299
Objective:To assess the value of urine heat-shock protein-70 (HSP-70) in the early diagnosis of acute kidney injury (AKI) after cardiac cardiopulmonary bypass (CPB).Methods:Patients with cardiopulmonary bypass from May 2018 to July 2018 in Henan Provincial People's Hospital were enrolled as subjects. Urine samples were collected before and after cardiopulmonary bypass at 0 h, 2 h, 4 h, 6 h, 8 h, 12 h, 24 h and 48 h. Patients were divided into AKI group and non-AKI group according to the Kidney Disease: Improving Global Outcomes Guide. Urinary HSP-70, tissue inhibitor of metalloproteinase-2 (TIMP-2) and insulin-like growth factor-binding protein 7 (IGFBP7) were detected by enzyme-linked immunosorbent assay (ELISA) and urine neutrophil gelatinase-associated lipocalin (NGAL) was determined by immunoturbidimetry. The receiver operating characteristic (ROC) curve was plotted to calculate the critical value, sensitivity and specificity of urine HSP-70, [TIMP-2]×[IGFBP7] and NGAL for the diagnosis of postoperative AKI after CPB.Results:A total of 45 patients were enrolled in the study. There were 24 cases in AKI group and 21 cases in non-AKI group. The level of urinary HSP-70, [TIMP-2]×[IGFBP7] and NGAL in AKI group were significantly higher than in the non-AKI group at each postoperative time point, with statistically significant differences (all P<0.05). The level of urinary HSP-70 in AKI group peaked at 2 h after CPB, which was significantly earlier than the peak time of urine [TIMP-2]×[IGFBP7] and urine NGAL (12 h after CBP and 4 h after CBP, respectively). Urinary HSP-70≥2.1 μg/L could predict postoperative AKI of CPB at 2 h after CPB, with the area under the curve ( AUC) of 1.00, the sensitivity of 100.0% and the specificity of 100.0%. Urinary [TIMP-2]×[IGFBP7]>19.1 μg 2/L 2 could predict postoperative AKI of CPB at 12 h after CPB with the AUC of 0.94, the sensitivity of 87.5%, and the specificity of 100.0%. Urinary NGAL>27.4 μg/L could predict postoperative AKI of CPB at 4 h after CPB with the AUC of 0.95, the sensitivity of 95.8%, and the specificity of 85.7%. The positive predictive value of urine HSP-70≥2.1 μg/L at 2 h after CPB was 100.0%, and the negative predictive value was 100.0%. Conclusions:The level of urinary HSP-70 increases earlier than that of urinary [TIMP-2]×[IGFBP7] and NGAL in patients with AKI after CPB. Clinical monitoring of urinary HSP-70 level contributes to early diagnosis of AKI.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.