1.Investigation on Disinfection in Hospitals in Zibo
Xujian WANG ; Xuehui TANG ; Ling WANG
Journal of Environment and Health 1993;0(03):-
Objective To understand the status of disinfection in hospitals in Zibo. Methods Sanitary investigation on the disinfection quality of indoor air ,hands of doctors and nurses,surface of objects,the sanitary quality of disinfection reagents in use and the intensities of ultraviolet ray emitted from ultraviolet lamps was carried out in 34 general hospitals with bed capacity of more than 100 and special hospitals in Zibo. Results The total qualified rates of above indexes were 86.77% for municipal hospitals ,78.77% for district (county)hospitals,61.63% for factory and mine-hospitals respectively,and between them revealed significant differences (?2=59.95,P
2.Evaluation of repair of large segmental defects with vascularized tissue-engineered bone induced by endothelial progenitor cells in rabbits
Xuehui WU ; Zhao XIE ; Qingyi HE ; Jianzhong XU ; Ling ZENG ; Weijun CHEN ; Dong SUN
Chinese Journal of Trauma 2010;26(3):275-279
Objective To evaluate the bone healing effect of vascularized tissue-engineered bone induced by endothelial progenitor cells(EPCs)in repair of large segmental radius defects in rabbits.Methods A total of 68 healthy New Zealand white rabbits were enrolled in the study and randomized into three groups,ie,experimental group(EPCs group):EPCs plus bone marrow mesenchymal stem cells (BMSCs)plus decalcified bone matrix(DBM);control group:BMSCs plus DBM;sham control group:pure DBM.Materials mentioned above were implanted into middle radius defects for 15 mm.At 12 and 16 weeks post-operatively,X-ray test,bone mineral density test,histological light microscopic test,osteocalcin immunohistochemical staining test and biomechanical test were carried out.Results Growth and plasticity of callus,speed of medullary cavity recanalization,bone healing speed and biomechanical intensity in the experimental group were all significantly better than those of control group.Conclusions Vascularized tissue-engineered bone induced by EPCs has strong osteegenic ability,can accelerate bone healing and hence is an effective method for repair of large segmental bone defects.
3.Assessment of the consistency of five standardized cystatin C measurement systems
Xiuzhi GUO ; Jie WU ; Li′an HOU ; Xuehui GAO ; Ali YE ; Zhihong QI ; Dawei TONG ; Shuling CHI ; Ling QIU
Chinese Journal of Laboratory Medicine 2014;(5):365-370
Objective To assess the consistency of four standardized cystatin C particle-enhanced turbidimetric assay (PETIA) and one particle-enhanced nephelometric immunoassay (PENIA) measurement systems Methods Performance verification test was conducted according to CLSI EP 15-A2 and EP9-A2. Fourty serum samples in comparative test were obtained from the remaining serum samples of outpatients in Peking Union Medical College Hospital in March 2013.Fourty serum samples were tested on Olympus AU5400 automatic biochemical analyzer ( four PETIA Cys C reagents:Shanghai Jingyuan Co ., Ltd, Beijing Leadman Biochemistry Co ., Ltd, Beijing Strong Biotechnologies , Maker Biotechnology in Sichuan , and labelled as A, B, C, D respectively) and PENIA N Latex Cys C measurement system on Siemens BNⅡ(labelled as E).Correlation analysis were performed among four PETIA methods one PENIA method Differences of each detection system were compared in the medical decision level 1,2,3,4 mg/L.The reference material ERM-DA471/IFCC was measured by five systems and bias ( percentage bias ) was calculate for each system.Results Results of systems A, B, C, D, E were 1.29(0.89-2.43), 1.30 (0.96-2.59), 1.22(0.90-2.44), 1.27(0.96-2.47), 1.14(0.82-2.05)mg/L.Chart shows bias among these five systems was small when Cys C concentration was less than 4mg/L.PETIA method A, B, C, D correlated with their mean value well , with the average deviation from their mean value ( percent deviation) at -0.017 -0.031 mg/L ( -3.1%-2.1%), and all were less than allowed bias from the biological variation (3.4%).The deviation of PETIA method A, B, C, D with their mean value in medical decision level at -0.176 -0.178 mg/L.Systems A, B, C, D correlated well with the result of PENIA method system E , and the mean deviation ( percent deviation ) was at 0.278 -0.326 mg/L ( 12.6%-18.5%) , and the deviation ( percent deviation ) in the medical decision level 0.055 -1.079 mg/L (5.51%-26.98%).Bias of PETIA method A, B, C, D Cys C system measuringERM -DA471/IFCC ranged from 0.22 to 0.39 mg/L ( 3.9%-7.0%) , which exceeded the allowable range of the reference material target value, and were larger than the allowable bias from biological variation (3.4%).Bias ( percent ) of PENIA method system E was -0.1 mg/L ( -1.7%) , within the allowable range of ERM-DA471/IFCC target value .Conclusions The consistency of four assesed PETIA Cys C reagents was relatively ideal, and improved markably after being traced to ERM-DA471/IFCC.Besides, the results of PETIA were higher than those of PENIA .Bias among these five systems was small when Cys C concentration was less than 4 mg/L, and the bias became larger in higher Cys C concentration.
4.Analysis on correlation between serum Lp-PLA2 level with ischemic stroke occurrence and prognosis in patients with hypertension
Yong QIN ; Yixin ZHOU ; Qing ZHAN ; Ying HAN ; Hongmei LU ; Wei LI ; Qin GU ; Xuehui LING ; Wenjie XU
International Journal of Laboratory Medicine 2018;39(2):163-165
Objective To explore the correlation between serum lipoprotein-associated phospholipase A2 (Lp-PLA2) level with the occurrence of ischemic stroke and prognosis in the patients with hypertension . Methods Eighty-eight patients with hypertension in this hospital from January 2013 to January 2016 were se-lected ,including 34 cases of simple hypertension and 54 cases of hypertension complicating ischemic stroke . The Lp-PLA2 level was detected .The severity of ischemic stroke was evaluated on 1 ,14 d after admission by adopting the NIHSS .The patients with hypertension complicating ischemic stroke were divided into the good prognosis group and poor prognosis group according to the NIHSS change situation .Moreover the independent predictive factors of prognosis were evaluated by adopting the Logistic multivariate regression .Results The Lp-PLA2 level in the patients with hypertension complicating ischemic stroke was significantly higher than that in the patients with simple hypertension .The Lp-PLA2 level (OR=1 .523 ,95% CI=1 .323-1 .657) and NIHSS score (OR=3 .275 ,95% CI=1 .402 -6 .208) at admission were the independent predictive factors of poor prognosis .Conclusion Serum Lp-PLA2 level is closely correlated with the occurrence and prognosis of ische-mic stroke in the patients with hypertension ,which can serve an evaluation index for the occurrence and prognosis of ischemic stroke in the patients with hypertension and provides an objective basis for the clinical therapy .
5. The investigation of the positive rate of intrinsic factor antibody and deficiency rate of vitamin B12 in normal physical examination population
Xuehui GAO ; Quexuan CUI ; Qiangxing ZHANG ; Xinqi CHENG ; Jun LU ; Ling QIU ; Bing HAN
Chinese Journal of Hematology 2018;39(11):917-920
Objective:
To explore the positive rate of intrinsic factor antibody (IFAb) and level of vitamin B12 (VitB12) in normal physical examination population and the possible relation between IFAb, VitB12 and sex, age, number of RBC, HGB and MCV.
Methods:
A total of 1 427 people who came to Peking Union Medical Colleague Hospital (PUMCH) for physical examination were enrolled. There were 758 males with average age of (52.5±14.5) years-old and 669 females with average age of (50.3±14.3) year-old. Beckman DxI800 automatic biochemical-immune analyzer and corollary reagents were used to analyze the level of serum IFAb and VitB12. The results in different sex, age were documented and their correlation with the value of whole blood cell count was tested later on.
Results:
Among the 1 427 normal subjects, 66 (4.63%) were positive for IFAb. The positive rate for IFAb in the population≥40 years-old was higher than those<40 years-old (5.66%
6.The performance evaluation of four Lp-PLA2 activity assays
Danchen WANG ; Li'an HOU ; Ling QIU ; Xiuzhi GUO ; Liangyu XIA ; Qiong WU ; Yi'cong YIN ; Honglei LI ; Dandan LI ; Qian LIU ; Xuehui GAO ; Liyan LIN
Chinese Journal of Laboratory Medicine 2018;41(3):208-213
Objective To evaluate the analytical performance of four lipoprotein associated phospholipase A2(Lp-PLA2)activity reagents on Beckman AU5800 automatic biochemical analyzer. Methods The remaining serum samples of 214 patients and 140 apparently healthy individuals were collected from March to July 2017 in Peking Union Medical College Hospital.These samples were used for method comparison and reference interval evaluation.According to the guidelines of EP15-A,EP6-A,EP-17 and EP7-P from Clinical and Laboratory Standards Institute(CLSI)standards,the precision, linearity, sensitivity and common interferences(e.g free bilirubin, conjunct bilirubin, hemoglobin and chyle)were assessed.According to EP9-A2,method comparisons of differents regents(Evermed,DiaSys,Hengxiao and Zhongyuan were labeled as A,B,C and D,respectively)were conducted and the differences were estimated at medical decision levels(328U/L,391U/L and 485U/L).Results The precision of four reagents were acceptable.The repeatability(CV%)of A to D were 0.5%-1.7%, 0.7%-3.0%, 0.9%-2.0% and 0.5%-3.3%,respectively.The reproducibility(CV%)were 0.7%-2.9%, 1.4%-3.2%, 1.3%-1.9%and 0.8%-4.1%,respectively.Both of those achievedlaboratory defined quality objective(<5%).The linearity of A to D were 44 -1 992 U/L,39 -1 798 U/L,13 -540 U/L and 75-1 717U/L,respectively.The regression coefficient R2 was between 0.997 and 1.000, and the correlation coefficient(r)was between 0.998 and 1.000.The interference of chyle were acceptable among these four reagents andmet the manufacturer′s requirementsor clinical needs.In a low level of Lp-PLA2,bilirubin had an obvious interferenceonreagent C;B and C were negatively affected when the hemoglobin was 4.5 g/L; and D was positively affected when the hemoglobin was 2.45 g/L.The regression coefficients R2 of A,C,D compared with B were between 0.978 and 0.995,and the correlation coefficients(r)were between 0.989 and 0.998. The expected differences at medical decision levels ranged from -240 U/L to 113 U/L.For A to D,the Lp-PLA2 activity results of 131(93.6%), 140(100%), 82(58.6%), and 128(91.4%)cases were analysed within the manufacturer′s claimed reference intervals.Conclusion The precision and linearity of the four Lp-PLA2 activity detection reagents used in automatic biochemical analyzer are good, but the anti-interference ability needs to be improved.
7.Consistency evaluation of thyroid stimulating hormone results from 4 chemiluminescence assays
Danchen WANG ; Songlin YU ; Yicong YIN ; Xiuzhi GUO ; Xinqi CHENG ; Ling QIU ; Chaochao MA ; Ruili ZHANG ; Qian LIU ; Li LIU ; Xuehui GAO ; Kui ZHANG
Chinese Journal of Clinical Laboratory Science 2019;37(1):62-66
Objective:
To compare the consistency of thyroid stimulating hormone (TSH) results from four chemiluminescence assays.
Methods:
A total of 102 fresh serum samples from Peking Union Medical College Hospital during March 2018 and April 2018 were collected for precision evaluation and methodological comparison referring to CLSI EP15-A2 and EP9-A2 protocols. The levels of serum TSH were detected by Abbott i2000 (system A), Beckman DXI800 (system B), Siemens ADVIA Centaur XP (system C) and Roche e601 (system D) automatic chemiluminescence analyzers and their matching reagents, respectively. The obtained results were compared with the passing-bablok and Bland Altman methods. Taking 0.27 μIU/mL and 5.33 μIU/mL as the medical decision level, the expected bias of each detection system was compared.
Results:
The precisions of systems A,B,C and D were 1.7%-3.3%, 2.3%- 3.9%,0.7%-2.3% and 0.6%-1.5%,respectively. The median (P 25,P 75) of TSH concentrations detected by systems A,B,C and D were 1.898 (0.518,4.809)μIU/mL, 2.819 (0.719,7.020)μIU/mL,2.502 (0.692,6.888)μIU/mL and 3.105 (0.886, 7.905)μIU/mL, respectively. The coefficients of determination (R 2 ) of regression equation were above 0.975 for 4 detection systems. The correlation coefficients (r), intercepts and slopes of 4 detection systems were 0.993 5-0.997 1, 0-0.06 and 0.59-1.15, respectively, and systems B and C had the best correlations with 1.02 of slope and 0 of intercept. The deviation plot showed that the bias% of 4 detection systems was between -48.1% and 17.3%. Among them, systems A and D had the largest bias, while systems B and C had the lowest bias. The expected bias of 4 detection systems at the medical decision level was -40.7%-37.2%.
Conclusion
The consistency between Beckman and Siemens TSH detection systems is good, while those of Roche and Abbott TSH detection systems are different from the other two.