1.Monoclonal antibodies in the treatment of malignant lymphoma
Journal of International Oncology 2009;36(5):384-387
In recent years, monoclonal antibody comes to be a new and promising kind of treatment mode for malignant lymphoma, because of its advantages, such as target property, minimal residual of tumor cell in vivo and little side effect. The main methods include single agent therapy, combination with chemothera-py, combination with immunotoxin, radioimmunotherapy and etc.
2.Simultaneous Determination of Five Major Lignans from Schisandrae Sphenantherae Fructus and Schisandrae Chinensis Fructus by Microemulsion Liquid Chromatography
Chinese Journal of Information on Traditional Chinese Medicine 2015;(5):94-98
Objective To develop a stable and sensitive microemulsion liquid chromatography method by using oil-in-water microemulsion mobile phase;To simultaneously determine five major active lignans, namely, schizandrin, schisandrol B, schisantherin A, deoxyschizandrin, and schisandrin B, in Schisandrae Sphenantherae Fructus and Schisandrae Chinensis Fructus. Methods The quantitative determination was conducted by using Kromasil C18 column (250 mm × 4.6 mm, 5μm). The influence of the composition of the microemulsion system on separation effect and retention time was studied. The method was optimized to sodium dodecyl sulfonate 3.3%(SDS, W/V), n-octanol 1.2% (V/V) and n-butanol 6.6% (V/V) in 20 mmol/L phosphate buffer (adjusted to pH 7.0 with orthophosphoric acid and sodium hydroxide). The flow rate was set at 0.7 mL/min. The compound peaks were detected by UV at 254 nm. The column temperature was 25 ℃. Results Under the optimized conditions, baseline separation of 5 lignans was achieved in 20 min, and the separation was satisfying. Schizandrin, schisandrol B, schisantherin A, deoxyschizandrin, and schisandrin B were in linear relation within the ranges of 2.0-155.0, 8.3-166.7, 8.8-175.8, 8.3-166.7, 8.9-177.1μg/mL (r>0.999). The limit of detection ranged from 0.06μg/mL to 0.18μg/mL, and the limit of quantitation ranged from 0.17μg/mL to 0.55μg/mL. The average recovery values were between 97.22%and 100.8%. Conclusion This method is simple, accurate and reliable, and can be successfully applied to simultaneous determination of five major active lignans in 13 batches of Schisandrae Sphenantherae Fructus and Schisandrae Chinensis Fructus from different producing areas in China.
3.Protective Effects of Recombinant Human Erythropoietin on Chronic Lung Injury Induced by Hyperoxia in Newborn Rats
xiao-lei, WANG ; xin-dong, XUE
Journal of Applied Clinical Pediatrics 1986;0(02):-
Objective To investigate the protective effects of recombinant human erythropoietin(rhEPO)treatment on histopathologic changes seen in hyperoxia induced lung injury.Methods Rat pups were randomly divided into four groups:Ⅰ:air-exposed control group,Ⅱ: air-exposed+rhEPO-treated group,Ⅲ:hyperoxia-exposed control group,Ⅳ:hyperoxia-exposed+rhEPO-treated group.GroupⅢ and Ⅳ rats were exposed to 85% oxygen.GroupⅡand Ⅳ rats were received rhEPO (1 200 U/kg) subcutaneously on postnatal 0 day and 2 day.On postnatal 14 day,survival curve,measurement of body weight and lung weight,radical alveolar counts(RAC),microvessel count were compared,CD_ 31 and vascular endothelial growth factor(VEGF) were performed by immunostaining to assess hyperoxia-induced changes in lung morphology.Results Treatment of hyperoxia-exposed rats with rhEPO prolonged the survival and resulted in a significant increase in the weight gain of body and lung[(25.88?2.59) vs(18.8?3.93) P
4.Experiences in clinical teaching of plastic surgery for individualized foreign students
Chunyu XUE ; Zhinong WANG ; Xin XING
Chinese Journal of Medical Education Research 2005;0(05):-
To improve the quality of clinical teaching of plastic surgery for foreign students at different levels,we think that good teaching result will be got by applying English teaching for whole range,attaching importance to the selection and cultivation of the teaching staff,establishing individualized teaching program and compiling suitable material,and sticking to trial teaching before class,collective discussion and flexible teaching methods.
5.Design and implementation of Neonate Information Management System
Li XIN ; Qingzheng XUE ; Yaai WANG
Chinese Medical Equipment Journal 2003;0(10):-
Objective To develop Neonate Information Management System for neonate information management in computer.Methods After detailed analysis for demand in neonate management,prototype law was used to develop the program with PowerBuilder9.0 and Micorsoft SQL Server 2000 as tools.Results Neonate Information Management System realized such functions as neonate information input & revision,data inquiry,data statistics,printing,etc.Besides,the operation was simple.Conclusions Neonate Information Management System makes the information input more accurate,and the inquiry more quick and convenient so that the personnel's working efficiency can be greatly enhanced.
6.Casae of dysphagia caused by stroke.
Ping-ju XUE ; Li-xin FU ; Lei WANG
Chinese Acupuncture & Moxibustion 2014;34(4):384-384
Acupuncture Therapy
;
Deglutition Disorders
;
etiology
;
therapy
;
Humans
;
Male
;
Middle Aged
;
Stroke
;
complications
7.Effect of iohexol on the renal function in children undergoing cardiac angiography.
Xin-Ying ZHANG ; Yu-Lin WANG ; Xue-Lian ZHU
Chinese Journal of Contemporary Pediatrics 2009;11(11):935-936
Child
;
Child, Preschool
;
Contrast Media
;
adverse effects
;
Coronary Angiography
;
Female
;
Humans
;
Infant
;
Iohexol
;
adverse effects
;
Kidney
;
drug effects
;
physiology
;
Male
;
beta 2-Microglobulin
;
urine
8.HIF-1α expression in lung tissue of rats with paraquat poisoning
Rong XU ; Ruilan WANG ; Xin WU ; Xue TANG
Chinese Journal of Emergency Medicine 2011;20(9):945-950
ObjectiveTo study the HIF-1α expression in rats with paraquat poisoning (PQP).MethodsNinety-six healthy SD rats were randomly (random number) divided into 2 groups ( n =48 in each group) : PQP group and control group. The PQP group was further divided into six subgroups as per thedifferent intervals after Paraquat intoxication. Samples from 6 PQP subgroups and control group were taken at 0 h, and 2 h, 6 h, 12 h, 24 h, 48 h, 72 h and 120 h after paraquat administration. Aarterial blood wascollected for blood gas analysis, and the sections of lung tissue were stained with hematoxyhn-eosin and masson's trichrome to detect the trichrome positive area, and HIF-1α was detected by immunohistochemistryAll data were processed with one-factor analysis of variance and Pearson correlation analysis. ResultsTwo hours after paraquat poisoning, the levels of HIF-1α protein and the collagen were both significantly upregulated in the lung tissue in rats with paraquat poisoning. However, the hypoxemia existed until 72h.There was correlation between levels of Masson's trichrome positive area and HIF-1α positive area (r =0. 819, P <0. 05 ). There was correlation between the levels of lactic acid in blood gas analysis and HIF-1α positive area (r=0. 761, P<0. 05. But there was no correlation between levels ofPO2 and HIF-1α positive area (r=-5.24, P>0. 05). ConclusionsThe level of HIF-1α was up-regulated in rats with paraquat poisoning and it was not associated with hypoxemla.
9.Non-invasive cardiac output measurement in children using bioreactance:a comparison with echocar-diography
Tian SANG ; Ying WANG ; Xue FENG ; Xin ZHANG ; Xueqin LIU
Chinese Pediatric Emergency Medicine 2016;23(2):78-81
Objective To investigate the value of measurement of cardiac output in children by bio-reactance versus echocardiography.Methods Pediatric patients admitted in pediatric department of Peking University First Hospital from September to December 2012 who needed hemodynamic monitoring were enrolled prospectively.Cardiac index(CI)and stroke volume(SV)were measured by echocardiography and non-invasive cardiac output measurement(NICOM)and compared by Spearman correlation and Bland-Alt-man analysis.Results Thirty patients were included.The median age was 7.25 years.CI[M(P5 ,P95 )] measured by NICOM and echocardiography were correlated significantly[3.42(2.28,4.92)L /(min?m2 ) vs.3.51 (2.94,4.85 )L/(min?m2 ),R =0.385,P =0.035 ].Bland-Altman analysis revealed a bias of-0.22 L/(min?m2 )(P =0.051 ),limits of agreement of -1.40 to 0.95 L/(min?m2 ).SV[M(P5 ,P95 )] measured by NICOM and echocardiography were correlated more significantly [36.3 (12.6,87.8 )ml vs.39.4(14.7,86.9)ml,R =0.768,P ﹤0.001 ].Bland-Altman analysis revealed a bias of -3.1 ml(P =0.176),limits of agreement of -27.4 to 21.2 ml.Conclusion There is no significant difference between NICOM and echocardiography for the measurement of CI and SV in pediatric patients.Further validation studies need to be conducted before routine clinical use.
10.Combination of urine sediment quantitative analyzer and urine dry chemistry analyzer in detection of urine cell
Xin LIU ; Shuguang ZHAO ; Xue BAI ; Yi WANG
International Journal of Laboratory Medicine 2015;(18):2679-2680
Objective To evaluate the efficacy of IQ200 urine sediment quantitative analyzer(IQ200) and Mejer700 urine dry chemistry analyzer(Mejer700) in detecting urine erythrocyte(RBC)and leukocyte(WBC) .Methods The WBC and RBC in 1 000 u‐rine specimens were detected by using IQ200 ,Mejer700 and sediment microscopy respectively .Taking sediment microscopy as the golden standard ,the sensitivity ,specificity and accuracy of IQ200 and Mejer700 in detecting urine RBC and WBC were analysed .Re‐sults No statistically significant differences of positive rates of RBC and WBC detected by using the three methods were found (P>0 .05) .When IQ200 and Mejer700 were combined ,the sensitivities of detection of RBC and WBC test were improved .Conclu‐sion The sensitivities of RBC and WBC detection by using IQ200 and Mejer700 are high .Combing the two methods the sensitivity and accuracy is higher ,which could improve work efficiency .Combination of the three methods should be recommended ,in order to improve the quality of urine analysis .