2.The use of bioluminescent image in monitoring islet graft in vivo after islet transplantation
Xue-Fei YANG ; Shao-Ping DENG ; Fu-Rong LI ;
Chinese Journal of Organ Transplantation 2005;0(11):-
Objective To demonstrate the superiority and feasibility of using bioluminescent image to monitor the islet graft after islet transplantation.Methods Diabetic models were established by intraperitoneal injection of streptomycin into mature male C57BL/6 mice.Islets were harvested from the pancreas of C57BL/6 and Bclb/c mice by digestion and purification,and transfected with Lueiferase gene.The mouse diabetic models were divided into iso-transplantaion group (n=20) and allo-transplantation group (n=7).The islets of C57BL/6 were transplanted into iso-transplantaion mice with different doses (10,50,110 and 200,n=5 in every dose),and Bclb/c mouse islets were transplanted into allo-transplantation group.The islets were transplanted into the subcutaneous fat tis- sue near left scapula.The receptor mice were scanned with CCD camera to get bioluminescent images at different scheduled time points,and the changes in random blood glucose of allo-transplantation group were observed.Results On day 6 after transplantation,the scanning image showed that the pi- xel intensity from the region of interest (ROI) was increased with the increased number of islet grafts and they had a positive correlation.The random blood glucose was reduced to the normal level in the first 2 days,and then increased again to the diabetic level on 11 days averagely,while pixel intensity from the ROI reached the peak on day 6-7,and then reduced rapidly after islet transplantation in allo- transplantation group.The beginning of pixel intensity reduction occurred on day (6.14?0.90), while that of the random blood glucose raise occurred on day (10.00?0.82) after transplantation,and the former alteration occurred obviously earlier than the latter (P
3.Construction and Application of Operation Room Digital Video Transmission System
Xinghua SHAO ; Zehe LI ; Haili ZHANG ; Zhigang XUE
Chinese Medical Equipment Journal 1989;0(04):-
Objective To improve the technology of operation room video transmission for remote view and exchange.Methods The integrated controllable environment,the core technology of digital video transmission and video-on-demand were applied in the system.Results The system was easy to set up and operate.It had a strong network adaptability.Conclusion A feasible interactive platform is built for surgery teaching,research,medical management in the hospital.
4.Manipulation parameter optimization in Liu's back tuina therapy for kids' cough variant asthma in remission stage
Xue LI ; Bin-Ye ZHU ; Xiang-Ning SHAO ; Jue HONG
Journal of Acupuncture and Tuina Science 2020;18(1):67-74
Objective: To determine the optimal manipulation parameters in Liu's back tuina therapy for remission-stage cough variant asthma (CVA) in kids. Methods: A 5-factor 3-level L18(37) orthogonal design was adopted. The experimental factors and levels were selected: A, the number of times of Rou-kneading Feishu (BL 13); B, the frequency of Rou-kneading Feishu (BL 13); C, the number of times of Tui-pushing in a '介'-like pattern; D, the frequency of Tui-pushing in a '介'-like pattern; E, the intensity of red color after Ca-scrubbing Feishu (BL 13) with salt. A1, A2 and A3 stood for 10 times, 20 times and 30 times, respectively; B1, B2 and B3 stood for 200 times/min, 240 times/min and 280 times/min, respectively; C1, C2 and C3 stood for 50 times, 75 times and 100 times, respectively; D1, D2 and D3 stood for 150 times/min, 175 times/min and 200 times/min, respectively; E1, E2 and E3 stood for pinkish, bright red and dark red, respectively. A total of 108 kids with CVA in remission stage were divided into 18 groups using the random number table method, with 6 cases in each group. Changes in the cough score and fractional exhaled nitric oxide (FENO) level were observed after 15-day treatment. Results: The cough score and FENO level changed significantly in every group after treatment (all P<0.01). By the effect in improving cough score, the factors were listed as D, B, A, C and E in descending order; the most optimal manipulation parameter combination was group 17 (A3B2C1D3E1); the second optimal parameter combinations were group 7 (A3B1C2D1E3), group 13 (A2B1C2D3E1) and group 14 (A2B2C3D1E2). Regarding the effect in down-regulating the level of FENO, the factors were listed as C, A, E, B and D in descending order; the most optimal manipulation parameter combination was group 13 (A2B1C2D3E1); the second optimal parameter combinations were group 18 (A3B3C2D1E2), group 16 (A3B1C3D2E3) and group 14 (A2B2C3D1E2).Conclusion: Two most effective manipulation parameter combinations were selected out of 18 different parameter combinations in Liu's back tuina therapy for remission-stage CVA in kids. Doctors can choose an appropriate manipulation based on the symptom features of the disease.
5.Clinical observation on 1g/L bromfenac sodium hydrate ophthalmic solution associated with glucocorticoid in high myopia after LASEK
Qing-He, LI ; Yue-Mei, LI ; Xue-Ying, SONG ; Hao, WANG ; Shao-Wen, QI
International Eye Science 2017;17(6):1133-1136
AIM:To observe the efficacy and safety of 1g/L bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after laser subepithelial keratomileusis (LASEK).METHODS: Totally 104 cases (208 eyes) were received LASEK, which were selected and divided into study group and control group.The study group were adopted 1g/L bromfenac sodium hydrate ophthalmic solution combined with tobramycin dexamethasone eye drops and fluorometholone eye drops, the control group were adopted tobramycin dexamethasone eye drops and fluorometholone eye drops.The changes of visual acuity and intraocular pressure of two groups were recorded before and after surgery, and the score of painness and the occurrence of haze were observed after surgery.RESULTS: At postoperative 1, 2, 3d, respectively, the pain score of the study group were 1.70±0.35, 1.25±0.34, 0.82±0.32, the pain score of the control group were 2.30±0.43, 1.68±0.44, 1.12±0.33, the differences were significant (P<0.05).Before and at 2wk, 1, 3mo after surgery, respectively, uncorrected visual acuity of study group were 0.035±0.02, 0.71±0.13, 0.89±0.17, 0.88±0.18, while which of control group were 0.037±0.015, 0.73±0.15, 0.87±0.14, 0.86±0.15 (P>0.05), and the differences were not significant(P>0.05).At preoperative and postoperative 1, 2wk, 1 and 3mo of surgery, respectively, the intraocular pressure of study group were 17.33±1.58, 7.54±1.28, 7.23±1.58, 7.26±1.47, and 7.30±1.36 mmHg;the intraocular pressure of control group were 17.53±1.43,7.57±1.32,7.73±1.55,7.80±1.38,7.86±1.43 mmHg,the differences were not significant between before and at 2wk after surgery(P>0.05), the differences were significant between the two groups at 2wk, 1mo and 3mo (P<0.05).At postoperative 1, 3mo of surgery, the score of haze level of the study group were 91.7% and 93.3%, respectively and which in control group were 92.0% and 92.9%, respectively, and the differences were not significant between the two groups at every time point(P>0.05).CONCLUSION: It is safe and effective that 1g/L bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after laser subepithelial keratomileusis.The patient has a lower intraocular pressure, has similar therapeutic effect as glucocorticoid in vision and antiinflammatory.
6.NIRS-based total quality control system construction of Tanreqing injection and relative thinking.
Wen-Long LI ; Shao-Yong LIU ; Dong-Sheng XUE ; Hai-Bin QU
China Journal of Chinese Materia Medica 2014;39(17):3409-3412
In this paper, NIRS (near infrared spectroscopy)-based total quality control system for the Tanreqing injection was introduced briefly. By analyzing and summing up the significance and difficulties, several important problems of the practical applications which need urgent solutions are proposed. And also the applicationprospect of NIRS is fully discussed and put forward in the end.
Drug Compounding
;
standards
;
Drugs, Chinese Herbal
;
administration & dosage
;
analysis
;
standards
;
Injections
;
Quality Control
;
Reproducibility of Results
;
Spectroscopy, Near-Infrared
;
methods
7.Technological parameter optimization method for washing of coarse bear gall powder extracts based on NIR spectroscopy.
Wen-Long LI ; Shao-Yong LIU ; Dong-Sheng XUE ; Zhi-Wei CHENG ; Hai-Bin QU
China Journal of Chinese Materia Medica 2014;39(1):75-79
During the washing process of coarse bear gall powder extracts, it is necessary to adjust the amount of ethyl acetate according to the properties of raw materials, which aims to improving the yield and purity of the final product. In the research, using NIR spectra to reflect the comprehensive properties of coarse bear gall powder extracts, the process is optimized in a flexible way. Forty batches experiments are designed according to the weight ratio of ethyl acetate and coarse extracts of bear gall powder. The NIR spectra of the coarse extracts of bear gall powder are collected and processed using principal component analysis (PCA) method. The first 8 principal components combined with the amount of the ethyl acetate are used as the input variables, and calibration models are established to predict the yield and purity of the final product 30 batches are used as calibration set, which is used to establish the models, and other 10 batches are used as validation set, which is used for the performance appraisal of the established models. The correlation coefficients of the calibration, inner cross-validation and external validation for the purity model are 0.902, 0.896 and 0.883, respectively, and the RMSEC, RMSECV and RMSEP are 1.22%, 1.48% and 1.59%, respectively. The correlation coefficients of the calibration, inner cross-validation and external validation for the yield model are 0.921, 0.859 and 0.916, respectively, and the RMSEC, RMSECV and RMSEP are 1.39%, 1.65% and 1.53% respectively. This work demonstrated that NIR spectra combined with technology parameter could be used to predict the yield and purity of the final product. Using the established models, the most appropriate amount of the ethyl acetate can be determined according to the properties of the coarse bear gall powder extracts, and the yield and purity of the final product can be improved.
Acetates
;
chemistry
;
Animals
;
Gallbladder
;
chemistry
;
Medicine, Chinese Traditional
;
Powders
;
chemistry
;
Principal Component Analysis
;
methods
;
Spectroscopy, Near-Infrared
;
methods
;
Ursidae
8.Development of Novel Microbial Lipase Resources
Zheng-Yu SHU ; Long-Yin XUE ; Rui-Feng LIN ; Shao-Li CAI ; Jian-Zhong HUANG ;
Microbiology 1992;0(05):-
Microbial lipase,one of important industrial biocatalysts,has been used widely in many industrial and agricultural fields.It is always the research focus to screen,mine and develop the microbial lipases with novel catalytic activity and high stability.This paper introduces briefly the pathways and methods to mine novel microbial lipase resources from six aspects,including extremophile,metagenome,genome database,protein engineering,immobilization,chemical modification,etc.
9.Karyotyping analysis of 396 newborns with congenital malformations and chromosomal abnormalities and the associated phenotypes
Hongying WANG ; Haibo LI ; Yaxiang HE ; Naichao YANG ; Xuejun SHAO ; Yongquan XUE
Chinese Journal of Applied Clinical Pediatrics 2014;29(20):1560-1563
Objective To reveal the chromosome abnormalities and their relationship with the clinical phenotype of neonates with congenital malformation.Methods Karyotype analysis of peripheral blood lymphocytes was performed on 396 newborns with congenital malformation,who were recruited at the Children's Hospital Affiliated to Soochow University from Jan.2006 to May 2012,chromosome karyotypes were prepared with neonatal peripheral lymphocytes by conventional G-banding technique.Results 1.Of 396 newborns,159 (40.2%) cases were detected to have chromosomal abnormalities,including karyotype first reported domestically and internationally in 3 cases.2.Trisomy-21 (Down's syndrome),which was the most common abnormal karyotype,was seen in 130 cases,accounting for 81.8%,of whom 119 cases show the standard type,10 cases accompanied by the Robertsonian translocation involving group D or group G,and 1 case accompanied by sexual chromosomal abnormality:inv(Y) (p1 1 q 1 1),+ 21.3.Other common karyotype abnormalities were as follows:del (5) (p 1 2-14) (cats cry syndrome) in 4 cases,trisomy-18 (Edwards syndrome)in 4 cases,45,XO (Turner' s syndrome) in 4 cases,inv (9) (p1 1 q1 2-21) in 4 cases,trisomy-X (super female syndrome) in 1 case,rob(13;14) in 1 case,trisomy-8 in 1 case and del(18) (q22) in 1 case.4.Special faces were seen in 147 cases (92.5 %),congenital heart disease in 97 cases (61.0%),low birth weight in 72 cases (45.3 %),congenital anal atresia in 13 cases(8.1%),multiple malformations in 11 cases (6.8%),intestinal malformations in 10 cases (6.2%),extrinsic genital abnormalities in 9 cases(5.7%),meow-like cry in 4 cases(2.5%),limb edema in 4 cases (2.5%),fingers and toe abnormalities in 6 cases(3.6%),congenital brain dysplasia in 6 cases (3.6%),webbed neck in 5 cases(3.1%) and cleft lip and palate in 3 cases(1.8%).Conclusions Chromosomal abnormality is an important factor leading to neonatal birth defects,of which special face,congenital heart disease,low birth weight,and multiple malformations are the main clinical manifestations of chromosomal diseases.
10.Expression and clinical significance of small fragments of P28 and P43 in papillary thyroid carcinoma after TRa1 gene transcription
Shiliang LI ; Lei XU ; Guoan SHAO ; Fenfen SUN ; Linyong SUN ; Jun XUE
Practical Oncology Journal 2017;31(4):294-298
Objective The objective of this study was to investigate the expression of P28 and P43 in papillary thyroid carcinoma(PTC)and its relationship with clinicopathological features after TRa1 gene transcription.Methods Real-time fluorescence quantitative PCR(RT-PCR)and gel electrophoresis were used to determine the target fragments and to isolate the bands of different fragments.The optical density of each band was scanned by UV transmittance analyzer to detect 31 cases of PTC tissue and expression levels of P28 and P43 in para-cancerous tissues.Results The average gray value of P28 in thyroid carcinoma group was 0.77±0.34,which was significantly higher than that in para-cancer group(0.31±0.18).The average gray value of P43(0.85+0.21)in thyroid carcinoma group was significantly higher than that in para-cancer group(0.34±0.15)(P<0.05).The expression levels of P28 were not correlated with gender,age,tumor size,lymph node metastasis and clinical pathologic stage(P>0.05),The expression levels of P43 were not correlated with gender,age,tumor size and lymph node metastasis.(P>0.05)but they were related to clinical pathologic stage(P<0.05).There was no correlation between expression levels of P28 and P43(r=0.266,P=0.071).Conclusion The increased expression of P28 and P43 may have a high degree of malignancy and a certain clinical value in predicting the adverse prognosis of PTC.Both factors are helpful for the prevention and treatment of PTC.