1.Distribution of mean platelet volume in the healthy and impaired fasting glucose individuals
Jing XUE ; Lixia LYU ; Wei LI ; Li YAN ; Hua YAN
Chinese Journal of Laboratory Medicine 2014;(6):451-454
Objective The different distribution and clinical significance of mean platelet volume (MPV) in the healthy normoglycemic and impaired fasting glucose (IFG) individuals were discussed.Methods The 499 individuals including 184 male and 315 female,who had undergone health checks in Tianjin Huanhu Hospital during May and July 2012 were studied retrospectively.Average age is forty-five ( thirty-five to eighty).Subjects were categorized into four groups according to fasting plasma glucose ( FPG) levels:G1 (3.89 mmol/L≤FPG<5 mmol/L, n=125),G2(5 mmol/L≤FPG <5.5 mmol/L, n=121), G3(5.5 mmol/L≤FPG<6.1 mmol/L, n=142), and G4(6.1 mmol/L≤FPG<7 mmol/L, n=111).G1, G2, and G3 are defined as normal FPG groups and G 4 is defined as IFG group.Eighty-nine cases in the same age patients with type II diabetes mellitus group ( G5 ) were observed at the same time.Results The MPV increased with the increasing FPG levels in the following order:G1(8.62 ±0.77) fl, G2 (8.85 ±0.80) fl, G3(8.90 ±0.69) fl,G4(9.14 ±0.78) fl and G5(12.03 ±1.42) fl.MPV[(12.03 ±1.42) fl] of type Ⅱdiabetes mellitus group(G5) was higher than that in the IFG group (G4)[(9.14 ±0.78) fl] and normal FPG groups[G1(8.62 ±0.77) fl,G2(8.85 ±0.80) fl,G3(8.90 ±0.69) fl] (F=12.773,P<0.01);MPV of the IFG group [ ( 9.14 ±0.78 ) fl ] was significantly higher than that in normal FPG groups [ G1 (8.62 ±0.77) fl,G2(8.85 ±0.80) fl,G3(8.90 ±0.69) fl] (F=12.773,P<0.01 for G4 vs.G1 and G2, P<0.05 for G4 vs.G3) ;MPV in the high-normal glucose group (G3) [(8.90 ±0.69) fl] was obviously higher than that in the low-normal glucose group (G1) [(8.62 ±0.77) fl] (F=12.773,P<0.05);MPV was positively associated with FPG in normal FPG groups ,IFG group and type Ⅱ diabetes mellitus group (G1-3:r=0.22, P<0.05;G4:r=0.26, P<0.01;G5:r=0.29, P<0.01).Conclusions Significant difference of MPV was observed in population of different FPG levels.Especially, MPV in IFG group was evidently higher than that in normal FPG group and was positively associated with FPG levels.
2.Personality as a moderator between personal disposable income and female depression
Jie YUAN ; Wei XUE ; Shaobo LYU ; Lina LI ; Jing WANG
Chinese Journal of Behavioral Medicine and Brain Science 2015;24(4):343-346
Objective To investigate the relationship between personal disposable income and female depression,and to examine the moderating roles of personality in this link.Methods The demographic questionnaire,self-rating depression scale (SDS) and eysenck's personality questionnaire short scale (EPQ-RSC) were used to survey 139 cases of married female patients with depression.Results Personal disposable income could be used to significantly and negatively predict female depression(β=-0.669,P<0.01).The interaction between personal disposable income and introversion-extroversion,personal disposable income and neuroticism was significant (β=0.142,P<0.05.β=-0.232,P<0.01).In the groups of higher and lower scores on the introversion-extroversion dimension,personal disposable income could be used to significantly predict female depression(β=-0.397,P <0.05.β=-0.452,P<0.05).In the group of higher scores on the neuroticism dimension,personal disposable income could be used to significantly predict female depression(β=-0.553,P<0.01),but not in the group of lower scores(β=-0.349,P>0.05).Conclusion Personal disposable income has significantly negative prediction effect on female depression,and introversion-extroversion and neuroticism have significant moderating effects on the relationship between personal disposable income and female depression.
3.Studies on the cognitive behavior and the myelin basic protein of the offspring in adult by infecting polyriboinosinic-polyribocytidilic acid in pregnacy
Fancui MENG ; Wenqiang LI ; Xue LI ; Yanli LU ; Shuang DING ; Hongxing ZHANG ; Luxian LYU
Chinese Journal of Behavioral Medicine and Brain Science 2014;23(8):728-731
Objective By analyzing the changes in behavior and the myelin basic protein (MBP) of the offspring in adult that treated with Poly(I∶C) during pregnancy,and to understand the role of white matter abnormalities in the abnormal behavior of the offspring induced by infection in maternal hosts.Methods Two models maternal female rats were given Poly(I∶ C) with 5 mg/kg and 10mg/kg respectively during the early pregnancy,and control maternal female rats was administered 5 mg/kg saline.The prepulse inhibition test,passive avoidance test and active avoidance test were used to evaluate schizophrenia like behaviors for each groups offspring in 8 weeks,and the expression of MBP was detected by immunohistochemical staining methods.Results The results of prepulse inhibition test showed that significant differences of PP2,PP4 and PP8 results existed among control group,single-dose model group and double-dose model group (F=10.381,P=0.001,F=10.313,P=0.001,F=15.233,P=0.000).Compared with the control group,the two model groups showed significantly lower,the double-dose model group was lower than single-dose model group (P<0.05).In passive avoidance test,there were significant differences of T1 and T2 results existed among control group,single-dose model group and double-dose model group (F=23.555,P=0.000,F=17.524,P=0.000).The T1 results of two model groups were significantly higher than control group,the double-dose model group was significantly higher than single-dose model group (P<0.05) ; the T2 results of two model groups were lower than control group,the double-dose model group was lower than single-dose model group(P<0.05).The results of passive avoidance test indicated that significant differences existed among control group,single-dose model group and double-dose model group in whole period of testing and total conditioned response rate(F=8.631,P=0.000,F=6.986,P=0.001),the two model groups were significantly lower than control group,double-dose model group was significantly lower than single-dose model group (P<0.05).MBP results of two model groups were significantly lower than control group,two model groups had no significant difference (P> 0.05).Conclusion The adult offspring that were treated with Poly (I∶C) exit abnormal behavior and damaged white matter,and there is a correlation between the degree of abnormal behavior and drug dose.
4.Analysis of the grants funded by National Natural Science Foundation on biomarker research in laboratory medicine during 2010 -2014 and future perspectives
Lixiang XUE ; Zhenghu JIA ; Kun LYU ; Min ZHANG ; Xin ZHANG ; Qingshu LI ; Zhangcai YAN
Chinese Journal of Laboratory Medicine 2015;(10):713-715
The accepted and supported items of National Natural Science Foundation related to biomarker research in laboratory medicine during 2010 to 2014 were summarized. The grants were categorized according to the biochemistry property of biomarkers and disease type .The features in the past 5 years were analyzed and the issues worth noticing for further research were also pointed out .
5.Evaluation of left ventricular transmural mechanics after anthracycline chemotherapy in patients with breast cancer by speckle tracking imaging
Jiping XUE ; Lili SU ; Chunsong KANG ; Zhifen WANG ; Shuai LI ; Hong LYU
Chinese Journal of Ultrasonography 2015;(12):1033-1038
Objective To evaluate the left ventricular transmural mechanics changes of breast cancer patients between before and after anthracycline chemotherapy by two-dimensional speckle tracking imaging (2D-STI),and to predict early cardiotoxicity caused by anthracycline.Methods Forty-six breast cancer patients with postoperative anthracycline-based chemotherapy were recruited.Echocardiography were performed on all subjects before and at 1 ,3 and 6 anthracycline-based chemotherapeutic cycle.Global longitudinal strain(GLS),endocardial longitudinal strain(LS-endo),epicardial longitudinal strain(LS-epi), global radial strain (GRS),endocardial radial strain (RS-endo ),epicardial radial strain (RS-epi ),global circumferential strain (GCS),endocardial circumferential strain (CS-endo)and epicardial circumferential strain(CS-epi) were assessed by 2D-STI and transmural myocardial strain gradient-longitudinal strain (TMSG-LS),transmural myocardial strain gradient-radial strain(TMSG-RS),transmural myocardial strain gradient-circumferential strain(TMSG-CS)were calculated.Conventional echocardiographic parameters and strain-related parameters before and after chemotherapy were compared. The receiver operating characteristics(ROC)curve was performed to determine sensitivity and specifity of strain parameters for prediction value of cardiotoxicity induced by anthracycline chemotherapy.Results ①After the sixth cycle of anthracycline chemotherapy,9 patients (16.4%)had developed anthracycline-induced cardiotoxicity,and 37 patients (80.4%)did not meet the criteria for cardiotoxicity.② There were no significant differences in conventional echocardiography parameters between before and after chemotherapy (P > 0.05 ).Left ventricular ejection fraction (LVEF),fractional shortening (FS)and E/A significantly decreased,but E/e significantly increased after six cycles of chemotherapy (P < 0.05 ).③ When comparison with baseline cases,GLS,LS-endo,LS-epi,TMSG- LS,TMSG-RS decreased after 3,6 cycles of chemotherapy,GRS, RS-endo and RS-epi decreased after six cycles of chemotherapy,the difference was statistically significant (P <0.05 ).④ ROC curve results showed the value of TMSG-LS,LS-endo,GLS and LS-epi after three cycles of chemotherapy to detect of anthracycline-induced cardiotoxicity,the areas under the curve were TMSG-LS> LS-endo> GLS> LS-epi.Conclusions After three cycles of chemotherapy,the decreases of TMSG-LS,LS-endo,GLS and LS-epi preceded the change of LVEF and other strain parameters,TMSG-LS and LS-endo can accurately and early detect anthracycline chemotherapy-induced cardiotoxicity.
6.Application value of biliary stent in endoscopic retrograde cholangio pancreatography for treatment of benign biliary stricture after liver transplantation
Jie HAO ; Yu LI ; Jie TAO ; Zheng WANG ; Xue YANG ; Liang YU ; Yi LYU ; Hao SUN
Chinese Journal of Digestive Surgery 2017;16(4):385-390
Objective To explore the application value of plastic biliary stent and fully covered self-expandable metallic stent (FCSEMS) in endoscopic retrograde cholangio pancreatography (ERCP) for treatment of benign biliary stricture after liver transplantation.Methods The retrospective cross-sectional study was conducted.The clinical data of 54 patients with benign biliary stricture after liver transplantation undergoing ERCP treatment who were admitted to the First Affiliated Hospital of Xi'an Jiaotong University between January 2010 and August 2016 were collected.Among 54 patients,44 had simple anastomotic stricture and 10 had non-anastomotic stricture.All the patients underwent stent implantation by ERCP.Patients with stricture within 1 month postoperatively initially selected single plastic stent or endoscopic nasobiliary drainage (ENBD),and then changed into multiple plastic stents at the second stent replacement.Patients with stricture after 1 month postoperatively selected multiple plastic stents,multiple plastic stents after balloon dilation or FCSEMS.Observation indicators:ERCP situations,stent implantation,time of stent indwelling,postoperative complications,stent dislocation,treatment outcome and follow-up situations.Patients were followed up by outpatient examination and telephone interview up to November 2016.Clinical symptoms of patients were observed within 1 month postoperatively and liver function and abdominal ultrasound were retested.Liver function and remission degree of biliary stricture were monitored regularly once every 3 months.Measurement data were described as average (range).Results All the patients underwent successful ERCP,of which 53 completed the process of ERCP and 1 rejected treatment due to economic problems.All the 54 patients received 140 times ERCPs with an average of 2.59 times per person,21 times ENBDs,11 times FCSEMSs and 108 times plastic stent implantations (including 35 times single stent implantations,46 times double stents implantations,23 times 3-stents implantations and 4 times 4-stents implantations).All the 54 patients were followed up for 3-143 months,with an average time of 73 months.Of 44 with anastomotic stricture,34 received plastic stent implantation and 98 times ERCPs,with an average number of stent implantation of 2 (range,1-4) and an average time of stent indwelling of 10.7 months (range,9.0-13.0months);the postoperative acute pancreatitis,biliary infection,hyperamylasemia and adverse stent implantation or dislocation were detected in 4 persons every time,7 persons every time,10 persons every time and 3 persons every time,respectively;26 patients were cured and 5 were improved,with an effective rate of 91.2% (31/34);3 patients with noneffective treatment continued to undergo ERCP and 3 patients had recurrence of anastomotic stricture.Among 10 patients with initial FCSEMS implantation,12 times ERCPs were performed,with an average time of stent indwelling of 7.6 months (range,6.0-12.0 months);postoperative biliary infection,hyperamylasemia and stent dislocation were detected in 1 person every time,1 person every time and 1 person every time,respectively;8 patients were cured,with an effective rate of 8/10;of 2 patients with persistent stricture,1 patient received contrast examination after stent removal,showing a comparative stricture in level 1 branch of intrahepatic duct and considering combined ischaemia,and then underwent the second implantation using multiple plastic stents;the other patient had elevated level of jaundice at 3 months after stents removal and received ERCP,showing anastomotic inflammatory polyp,and then underwent FCSEMS implantation again.Ten patients with non-anastomotic stricture received plastic stent implantation and 30 times ERCPs,with an average number of stent implantation of 3 (range,2-4) and an average time of stent indwelling of 11.3 months (range,10.0-14.0 months);the postoperative acute pancreatitis,biliary infection,hyperamylasemia and adverse stent implantation or dislocation were detected in 2 persons every time,5 persons every time,2 persons every time and 1 person every time,respectively;3 patients were cured and 3 were improved,with an effective rate of 6/10;of 4 patients with noneffective treatment,2 died of gradually deteriorating liver function and 2 underwent the second liver transplantation.Conclusions Stent implantation in ERCP is safe and effective for treatment of benign biliary stricture after liver transplantation,single plastic stent should be used in the early period (within 1 month) and multiple plastic stents should be used in the later period.Although FCSEMS has a higher displacement rate,it should be recommended due to a better clinical effect,lower incidence of complications and simple operation.For patients with non-anastomotic stricture,plastic stent should be used for extrahepatic biliary stricture,with a good clinical effect,and there is worse effect in stent implantation through ERCP for multiple intrahepatic biliary strictures.
7.Autofluorescence and spectrum characteristics of Echinococcus granulosus culturing in vitro
Ning YANG ; Xue ZHANG ; Chuanshan ZHANG ; Guodong LYU ; Liang LI ; Huanyuan LIU ; Hui WANG
Chinese Journal of Zoonoses 2015;(3):222-226,231
The objective of this study was to illustrate the autofluorescence phenomenon and scanning confocal λcharacteris‐tics of Echinococcus granulosus (Eg) cultured in vitro ,which can not only rich the spectroscopy and biological information of Eg ,but also lay a foundation for study the immunofluorescence and medical photonics .Protoscoleces (PSC) of Eg were aspi‐rated and pooled from sheep liver hydatid cysts collected from a slaughterhouse .The PSC viability was determined by Methyl‐ene blue staining .The autofluorescence of endocyst were observed through the confocal microscope excited respectively by 405 nm ,488 nm ,514 nm ,and 561 nm .The autofluorescence curve was measured by thermo Varioskan Flash respectively by 405 nm ,488 nm ,514 nm ,561 nm ,and 633 nm .Theλ scanning analysis was executed by confocal respectively by 405 nm ,488 nm ,514 nm ,561 nm ,and 633 nm to measure the autofluorescence curve .The Eg excited by different excitation light through confocal showed different colors autofluorescence .Under the same excitation intensity and detector voltage condition ,blue fluo‐rescence showed the best fluorescence effect and clearer structure which excited by 405 nm laser .Scanning respectively by five different excitation lights ,the corresponding sensitive emission wave lengths scope were 490‐520 nm ,around 520 nm and 580 nm ,580‐600 nm ,610‐630 nm ,and around 650 nm ,respectively .The 405 nm ,488 nm and 561 nm excitation effect were bet‐ter than that of the 514 nm and 633 nm .The autofluorescence curve detected by Microplate Reader were basically as same as that by confocal ,although the intensity detected by Microplate Reader were lower .The results indicated that the best excita‐tion light to detect the autofluorescence of Eg is 405 nm ,which showed blue fluorescence . The autofluorescence spectrum of Eg is wide ,mainly in 490‐520 nm and 610‐630 nm .The better excitation wave lengths are 405 nm ,488 nm and 561 nm .
8.The value of color Doppler ultrasound in diagnosing in-stent restenosis in lower limb artery
Shijing, SONG ; Huizhan, LI ; Qingmei, YANG ; Xiaoyan, KANG ; Fucheng, YAO ; Jiping, XUE ; Hong, LYU ; Chunsong, KANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(9):710-714
Objective To investigate the value of color Doppler flow imaging(CDFI) in diagnosing lower limb artery in-stent restenosis (ISR), and to provide the evidences for clinical application. Methods Patients with lower limb artery percutaneous transluminal stent insertion in 12 months were enrolled in this study and divided into two groups, CT angiography (CTA) or digital subtraction angiography (DSA) was applied to diagnose ISR, 31 patients with 47 stenting which were diagnosed ISR was named as restenosis group, 63 patients with 89 stenting which were diagnosed no ISR was named as no stenosis group, and 30 normal person was enrolled and named as normal control group. Ultrasonic characteristics and peak systolic blood flow velocity (PSV), systolic blood flow acceleration time (AT) of proximal part, inner stents, distal part were recorded in restenosis group and no stenosis group, then compared with data in normal control group. Regression and receiver operator (ROC) curve were applied to analyse the correlation between PSV and AT. Results PSV of no stenosis group in common femoral artery, femoral artery, superifcial, popliteal artery stent respectively were (146.71±35.59) cm/s, (120.11±25.67) cm/s, (96.44±32.87) cm/s. PSV of normal control group in common femoral artery, femoral artery, superifcial, popliteal artery respective were (119.67±15.34) cm/s, (91.17±15.09) cm/s, (71.13±21.23) cm/s. There was statistically signiifcant difference between the two groups (t=2.457, 2.459, 2.321, all P<0.05). AT of no stenosis group in common femoral artery, femoral artery, superficial, popliteal artery stent respectively were (84.98±13.77) ms, (87.33±16.36) ms, (90.77±12.05) ms. AT of normal control group in common femoral artery, femoral artery, superficial, popliteal artery respective were (78.23±21.24) ms, (82.31±18.24) ms, (84.29±23.01) ms. There was no statistically signiifcant difference between the two groups (t=1.696, 1.904, 1.835, all P>0.05). PSV of restenosis group in proximal part, restenosis part, distal part respectively were (87.67±23.34) cm/s, (218.17±72.09) cm/s, (54.13±21.23) cm/s. PSV of no stenosis group in proximal part, inner stents, distal part respectively were (91.71±25.59) cm/s, (131.11±45.67) cm/s, (96.44±32.87) cm/s. There was statistically significant difference between restenosis part/inner stents, distal part (t=3.412, 3.511, both P<0.05). There was no statistically signiifcant difference between the two groups in proximal part (t=1.901, P>0.05). AT of restenosis group in proximal part, restenosis part, distal part respectively were (98.31±14.09) ms, (109.54±21.03) ms, (158.23±45.21) ms. AT of no stenosis group in proximal part, inner stents, distal part respectively were (84.98±13.77) ms, (86.34±19.36) ms, (83.77±17.05) ms. There was statistically signiifcant difference between restenosis part/inner stents, distal part (t=2.319, 3.610, both P<0.05). There was no statistically signiifcant difference between the two groups in proximal part (t=1.833, P>0.05). ROC curve showed that in ISR lower limb artery, PSV>168 cm/s had a sensitivity of 89.4%, speciifcity of 92.1%, the area under the ROC curve was 0.949;AT>127 ms, had a sensitivity of 86.8%, speciifcity of 98.0%, the area under the ROC curve was 0.867. Conclusions CDFI can detect the changes of PSV and AT, ISR can be detected and diagnosed earlier in lower limb artery. By combining PSV>168 cm/s with AT>127 ms, the value of ISR diagnosis can be increased.
9.Construction of enterhemorrhagic Escherichia coli strain deleted for espO gene and analysis of its biological functions
Qiaoling LEI ; Juan XUE ; Xing PAN ; Jun LYU ; Jin YANG ; Ping ZHU ; Kun MENG ; Shan LI
Chinese Journal of Microbiology and Immunology 2021;41(2):88-96
Objective:To analyze the effects of espO gene knockout on the biological characteristics of enterhemorrhagic Escherichia coli (EHEC). Methods:Two-step methods mediated by the suicide plasmid pCVD442-Δ espO and plasmid pTrc99a were used to construct the espO gene-deleted strain (Δ espO) and the complemented mutant (CΔ espO), respectively. HeLa cells were infected with different EHEC strains to analyze the biological functions and lethal effects of espO gene during infection. Results:PCR, electrophoresis and gene sequencing showed that the Δ espO and CΔ espO mutants were successfully constructed. Compared with the wild-type strain, neither the Δ espO nor CΔ espO mutant showed significant difference in growth rate, indicating that the espO gene had no influence on the growth and replication of EHEC. Furthermore, EspO could activate the tumor necrosis factor receptor (TNF)-induced NF-κB signaling pathway, while the effector protein NleB could inhibit the process. EspO could not inhibit the death of HeLa cells induced by TNF or TNF-related apoptosis-inducing ligand (TRAIL) after EHEC infection. Conclusions:In this study, we successfully constructed the espO gene-deleted and complemented mutants of EHEC and preliminarily analyzed the interaction between espO gene and host cells and the effects of espO gene on cell apoptosis during infection, which provided reference for further research on the in vitro biochemical activity and in vivo pathogenic roles of EspO.
10.The effect of the extracellular vesicle loaded polylactic acid microspheres in promoting hepatocyte proliferation
CHU Jin ; Mukexina Mulati ; GAO Jin ; LI Liang ; ZHANG Xue ; LYU Guodong ; LIN Renyong ; BI Xiaojuan
China Tropical Medicine 2023;23(10):1030-
Abstract: Objective To prepare a microparticle delivery system that regulates the release rate of extracellular vesicles (EVs), and to exert long-term enhancement of liver cell proliferation after only one intervention. Methods EVs was extracted by differential centrifugation. The structure of the EVs was observed by transmission electron microscopy and the membrane marker protein of EVs was detected by Western blotting. EVs-PLA microspheres with "core-shell" structure were prepared by emulsion-solvent evaporation method. Scanning and transmission electron microscopy were used to detect the morphology of EVs-PLA microspheres and EVs. The release test detected the release behavior of EVs in EVs-PLA microspheres. Scanning electron microscopy was used to detect the morphological changes of EVs-PLA microspheres at 8 weeks of release. EVs-PLA microspheres were co-cultured with hepatocytes, and Phalloidin/DAPI staining was used to observe the cell morphology and evaluate the cytotoxicity of the microspheres. CCK8-test was used to evaluate the cell proliferation activity. Western blot analysis was used to detect extracellular vesicles membrane marker protein expression. Results Comparing the ability of hepatocyte proliferation in the group treated with EVs-PLA microspheres and the control group, it was found that EVs-PLA microspheres did not cause cell apoptosis and mutation in cell structure, had biocompatibility and no cytotoxicity. The EVs-PLA microspheres with "core-shell" structure regulated the release behavior of EVs, which can continuously release EVs, exerting a continuous biological role in promoting hepatocyte proliferation after a single intervention. Conclusions The EVs-PLA microspheres can control-release EVs and promote hepatocyte proliferation continuously after a single intervention, providing a reference for further exploration of EVs-loaded delivery systems in promoting liver regeneration.