1.Analysis of the comparison results of dental CBCT phantoms in radiological health technical service institutions in Guangdong Province, China
Xuan LONG ; Hongwei YU ; Zhan TAN ; Lei CAO ; Weixu HUANG ; Huifeng CHEN ; Aihua LIN
Chinese Journal of Radiological Health 2025;34(2):219-224
Objective To understand the situation of dental cone beam computed tomography (CBCT) quality control testing phantoms in radiation health technical service institutions in Guangdong province, analyze the differences among different phantoms, and provide a reference for dental CBCT quality control testing. Methods The testing phantoms of 49 radiation health technical service institutions were used as the research objects. The designated CBCT equipment was used for scanning and imaging. The Z-score method was used to evaluate the high-contrast resolution, low-contrast resolution, and distance measurement deviation of each phantom. Results The satisfaction rates of various items for the phantoms in 49 institutions ranged from 85.7% to 100%. The distance measurement deviations of four institutions were “suspicious”, and the high-contrast resolution of four institutions and the distance measurement deviation of one institution were “unsatisfactory”. Conclusion The overall performance of dental CBCT quality control testing phantoms in radiological health technical service institutions in Guangdong province is satisfactory. However, there are still some phantoms with poor results in items such as distance measurement deviation and high-contrast resolution. The structural design, material selection, and manufacturing process of the phantom may all affect the results of quality control testing. Therefore, appropriate phantoms, optimized exposure conditions, and suitable reconstruction algorithms should be used in CBCT quality control testing to ensure accurate and reliable measurements.
2.Analysis of differences in radiation dose rates in the fluoroscopic protection zone of digital subtraction angiography devices
Hongwei YU ; Zhan TAN ; Pengxiang QU ; Weixu HUANG ; Xuan LONG
Chinese Journal of Radiological Health 2025;34(3):348-353
Objective To analyze bedside radiation dose rates for interventional surgery operators in Guangdong Province, examine dose distribution patterns, and identify potential weaknesses in radiation protection, and to provide guidance for optimizing radiation monitoring and protection measures. Methods A total of 209 digital subtraction angiography devices measured in Guangdong Province between 2017 and 2024 were used as the research objects. The first and second operator positions were set at 30 cm and 90 cm horizontally from the X-ray tube focal point, respectively. Monitoring points were set up at 155, 125, 105, 80, and 20 cm above the ground. Results The median bedside radiation dose rate for interventional surgery operators in Guangdong Province was 83.0 (3.9,
3.Research progress on age-related changes in binocular vision
Chunyan LAI ; Changkang LUO ; Xuan LIAO ; Changjun LAN ; Qingqing TAN
International Eye Science 2025;25(11):1820-1825
With the accelerating process of population aging, binocular vision disorders have become increasingly prevalent, posing new challenges for both social aging strategies and ophthalmic clinical practice. Non-strabismic binocular vision anomalies(NSBVAs)are notably prevalent among elderly populations; however, current research predominantly focuses on the abnormality rates derived from individual binocular vision clinical tests, while data on the actual prevalence based on comprehensive diagnostic criteria remain limited. This review synthesizes existing scientific literature to provide a concise yet comprehensive overview of the prevalence, risk factors, and clinical diagnostic methods of NSBVAs in pre-presbyopic and presbyopic populations, with an in-depth examination of age-related changes in binocular vision function among older adults. By integrating and comparing analyses of the correlations between age and various binocular vision parameters, this review aims to enhance understanding of age-related binocular vision dysfunction and establish a theoretical foundation for developing targeted diagnostic and therapeutic approaches. Ultimately, these insights could contribute to improved visual performance and life satisfaction in elderly individuals.
4.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.
5.Predictive value of early thyroid function changes for the curative effect of 131I therapy in patients with Graves′ disease
Yan WANG ; Feng YU ; Renfei WANG ; Zhaowei MENG ; Guizhi ZHANG ; Ruiguo ZHANG ; Danyang SUN ; Xuan WANG ; Jian TAN ; Wei ZHENG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(1):30-34
Objective:To investigate the predictive value of early thyroid function changes on the efficacy of patients with Graves′ disease (GD) after 131I therapy. Methods:Data of patients with GD (59 males, 214 females; age (37.4±11.4) years) who underwent single therapy of 131I in Tianjin Medical University General Hospital from November 2017 to January 2019 were retrospectively analyzed. Symptoms, signs and laboratory tests (serum free triiodothyronine (FT 3) and serum free thyroxine (FT 4)) of patients were observed to assess the efficacy of 131I treatment. Efficacy was divided into complete remission (CR), partial remission (PR), non-remission (NR) or relapse. The changes of thyroid function (ΔFT 3=FT 3 before treatment-FT 3 after treatment)/FT 3 before treatment×100%; ΔFT 4=FT 4 before treatment-FT 4 after treatment)/FT 4 before treatment×100%) 1 month after 131I therapy in each efficacy group and differences among them were compared by using independent-sample t test, χ2 test, one-way analysis of variance and the least significant difference t test. ROC curves were drawn to analyze the predictive values of early thyroid function changes on the efficacy of 131I treatment for GD. Logistic regression analyses were performed to identify the influencing factors for the efficacy of 131I therapy. Results:CR rate and total effective rate of 273 GD patients after single therapy of 131I were 67.03%(183/273) and 92.67%(253/273), respectively. After 1 month, CR rate of euthyroidism group ( n=95) was significantly higher than that of hyperthyroidism group ( n=178; 81.05%(77/95) vs 59.55%(106/178); χ2=4.60, P=0.032). ΔFT 3 and ΔFT 4 at the first month were statistically significant and decreased sequentially in the CR group ( n=183), PR group ( n=70), NR or relapse groups ( n=20; F values: 15.40, 12.54, both P<0.001). ROC curve analysis showed that patients with ΔFT 3≥73.64% and (or) ΔFT 4≥59.03% had a higher probability of achieving CR, with sensitivities of 84.3% and 86.7%, and specificities of 62.6% and 62.6%, respectively. Logistic regression analysis showed that 24 h radioactive iodine uptake (odds ratio ( OR)=1.095, 95% CI: 1.031-1.139), dose of 131I given per gram of thyroid tissue ( OR=1.562, 95% CI: 1.321-1.694), ΔFT 3 ( OR=1.354, 95% CI: 1.295-1.482), ΔFT 4 ( OR=1.498, 95% CI: 1.384-1.608) were factors affecting the outcome of patients with GD treated with 131I treatment (all P<0.05). Conclusion:Effects of 131I treatment can be predicted based on the change of the thyroid function at the first month after 131I treatment in patients with GD.
6.Surgical treatment strategy for Chiari typeⅠ malformation complicated with syringomyelia
Tao WANG ; Xin-Yuan SUN ; Rong TAN ; Yi-Kun SUN ; Fan-Xuan KONG ; Nan LI ; Pei-Xin WANG
Journal of Regional Anatomy and Operative Surgery 2024;33(7):646-649
Objective To investigate the clinical efficacy and surgical experience of modified posterior fossa decompression combined with dural expansion repair in the treatment of type Ⅰ Chiari malformation complicated with syringomyelia.Methods The clinical data of 47 patients with Chiari type Ⅰ malformation complicated with syringomyelia treated by modified posterior fossa decompression combined with dural expansion repair in our hospital were analyzed retrospectively.The changes of posterior cranial fossa volume,cerebellar tonsil and syringomyelia were evaluated by MRI after operation.The scores of Japanese Orthopaedic Association(JOA)were used to evaluate the improvement of neurological function,and the complications were recorded.Results All the 47 patients successfully completed modified posterior fossa decompression combined with dural expansion repair.The main postoperative complications were unilateral limb numbness,incision pain,fever,subcutaneous effusion and so on,all of which were cured after symptomatic treatment.During the follow-up period,the clinical symptoms and neurological function of the patients were improved in varying degrees,and there was no deterioration of neurological function or death cases.The JOA score of the patients 3 months after operation was(15.83±1.31),which was higher than that of(14.66±2.06)before operation,the difference was statistically significant(P<0.05).MRI showed the extent of syringomyelia was reduced or disap-peared 6 after surgery in all 47 patients.Conclusion Modified posterior fossa decompression combined with dural expansion repair for the treatment of type Ⅰ Chiari malformation complicated with syringomyelia can not only ensure the decompression effect,but also increase the support of the contents of the posterior fossa,effectively prevent postoperative local adhesions,and restore the normal physiological circulation of cerebrospinal fluid in the cisterna magnum,which is an effective treatment method for type Ⅰ Chiari malformation complicated with syringomyelia.
7.Association between cognitive function and anterior cingulate cortex gamma-amino-butyric acid concentrations in patients with depression before and after treatment
Siyan ZAN ; Congwen KU ; Shaokun ZHAO ; Ruihua MA ; Sijia LIU ; Jing SHI ; Yingna LI ; Hui LI ; Xuan WANG ; Fude YANG ; Yunlong TAN ; Baopeng TIAN ; Zhiren WANG
Chinese Mental Health Journal 2024;38(9):737-744
Objective:To explore the association between cognitive function and the level of gamma-amino-butyric acid(GABA)in anterior cingulate cortex(ACC)before and after treatment in patients with major depres-sion disorder.Methods:Totally 31 medication-naive patients with major depression disorder meeting the criteria of the Diagnostic and Statistical Manual of Mental Disorders,Fifth Edition(DSM-5)and 33 normal controls were col-lected.Each eligible patient received treatment with selective serotonin reuptake inhibitor agents for 8 weeks.The MATRICS Consensus Cognitive Battery(MCCB)was used to evaluate the cognitive function.By means of 1H magnetic resonance spectroscopy,anterior cingulate cortex GABA concentrations were measured.Results:At base-line,the concentration of ACC GABA relative to water(GABA+/W)was lower in the patient group than in the control group(P<0.05)and increased after treatment(P<0.05).ACC GABA+/W was negatively associated with verbal learning and visual memory score in patient group at baseline(correlation coefficient and P value were r=-0.40,P<0.05;r=-0.42,P<0.05,respectively).The ACC GABA+/W difference resulted of treatment in patient group was positively associated with the difference of working memory score and the difference of reasoning and problem-solving score(correlation coefficient and P value were r=0.58,P<0.05;r=0.66,P<0.05,respec-tively).Conclusion:The cognitive dysfunction of patients with major depression disorder may not be related to the degree of depression and anxiety.And improvement of cognitive function may be associated with increase of ACC GABA concentrations.
8.Analysis of risk factors for prognosis of interventional treatment of multiple pelvic fractures with bleeding
Shengpan JIANG ; Shilin ZHENG ; Xuan LIU ; Yiqing TAN
Journal of Practical Radiology 2024;40(6):977-980
Objective To explore the risk factors for the prognosis of interventional treatment of multiple pelvic fractures with bleeding.Methods A total of 82 patients with multiple pelvic fractures with bleeding were selected.All patients underwent interventional treatment and were divided into a death group(n=9)and a survival group(n=73)based on their treatment prognosis.The data of the two groups were reviewed and the complications,abbreviated injury scale(AIS),Glasgow prognostic score(GPS),and injury severity score(ISS)between the two groups were compared,and multivariate logistic regression was used to explore the influencing factors of patients prognosis.Results Eighty-two patients with multiple pelvic fractures with bleeding had 9 deaths after interventional treatment,with a mortality rate of 10.98%.The univariate results showed that there were statistical differences in the mortality rate of patients with multiple pelvic fractures with bleeding after interventional treatment,as well as the time to hospital after injury,combined trauma,blood transfusion,and surgical time(P<0.05).The total incidence of respiratory failure,shock and infection in the death group(44.44%)were higher than those in the survival group(15.07%)(P<0.05).The AIS,ISS,and acute physiology and chronic health evaluationⅡ(APACHE Ⅱ)in the death group were higher than those in the survival group(P<0.05);The GPS was lower than that of the survival group(P<0.05);The multivariate logistic results showed that the time to hospital after injury,combined trauma,blood transfusion,surgical time,complications,AIS,ISS,APACHE Ⅱ and GPS were the influencing factors for the mortality rate of patients with multiple pelvic fractures with bleeding treated with intervention(P<0.05).Conclusion The proportion of deaths in patients with multiple pelvic fractures with bleeding is often influenced by factors such as complications,time to hospital after injury,combined trauma,AIS,GPS,and ISS.However,early interventional treatment is recommended to improve the patient's treatment prognosis with minimal trauma and good results.
9.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.