1.Comparison of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer
Wei, QIU ; Yanjun, HUA ; Zequan, XU ; Qiang, WU
Chinese Journal of Experimental Ophthalmology 2017;35(6):544-547
Background The measurement of corneal Q value is essential for corneal refractive surgery and calculation of intraocular lens during cataract surgery.Topolyzer was often used for the measurement of Q value,and recently Topcon KR-1W and iTrace were applied in ophthalmology.However,whether the measured values are interchangeable is unclear.Objective This study was to assess the difference and consistency of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer.Methods Corneal Q values were measured on 100 right eyes of 100 healthy subjects under the approval of Ethic Committee of the Sixth Hospital Affiliated to Shanghai Jiaotong University and informed consent of each subject from November to December in 2014 with Topcon KR-1W,iTrace and Topolyzer.Three valid measurements were obtained for each device,and the average values from each device were calculated.The difference of the outcomes among the instruments was compared by repeated measures analysis of variance (ANOVA),and the consistency among the outcomes from different apparatus was analyzed by Bland-Altman plots.Results The mean corneal Q values were-0.184-±0.112,-0.117±0.167 and-0.269±0.117 from Topcon KR-1W,iTrace and Topolyzer,respectively,with a significant difference among them (P < 0.001).The measured Q value by Topcon KR-1W was 0.085±0.010 larger than that by Topolyzer,and the Q values by iTrace was 0.152± 0.014 larger than that by Topolyzer,while the Q values obtained by Topcon KR-1W was 0.067±0.016 smaller than that by iTrace (all at P<0.05).The 95% confidence interval of the values between Topcon KR-1W and iTrace,Topcon KR-1W and Topolyzer,iTrace and Topolyzer were-0.106 to-0.028,0.060 to 0.109 and 0.118 to 0.186,respectively.Bland-Altman plots showed that 6%,6% and 5% values were outside of 95% agreement of limit (LoA) between Topcon KR-1W and iTrace,iTrace and Topolyzer or KR-1W and Topolyzer,respectively,with the maximal differences of 0.28,0.43 and 0.38.Conclusions Corneal Q values measured by Topcon KR-1W and iTrace are larger than those measured by Topolyzer.Due to the poor agreements among the corneal Q values by the 3 kinds of devices,they are not interchangeable in clinical applications for the measurement of corneal Q value.
2.Effect of speech therapy on mental health of patients with aphasia
Xu HE ; Jun HONG ; Jian-hua LIN ; Ling QIU
Chinese Journal of Rehabilitation Theory and Practice 2002;8(11):694-695
ObjectiveTo investigate the effect of speech therapy on mental health of patients with aphasia. MethodsCRRCAE and SCL-90 were used to assess the speech and mental state in 28 aphasia patients. All aphasia patients were treated by using speech therapy and the changes before and after treatment were compared. ResultsThe scores in listening comprehension, repetition, naming, reading,reading comprehension, writing and counting were distinctly higher at post-treatment than that at pre-treatment. All SCL-90 factor's levels at post-treatment were distinctly reduced than that at preat post-treatment(P<0.01).Conclusions Speech therapy can improve the language function,as well as mitigate the mental symptoms.
3.Application of Simple Biopsy Clip by Ultrasound-Guided Percutaneous on Renal Biopsy in Children
qiu-qin, XU ; xiao-zhong, LI ; mei-hua, ZHANG ; hua, KUAI
Journal of Applied Clinical Pediatrics 1992;0(05):-
Objective To analyze the safety and diagnostic value of ultrasound-guided biopsy with simple biopsy clip in children.Methods Under simple biopsy clip 52 cases were performed percutaneous renal biopsy.Then the curative rate and the incidence rate of complications were evaluated.Results Of 52 cases,49 cases(94.23%) gained enough renal tissue specimen for histological evaluation;Three failed cases occurred at early stage,nothing was found at later stage.The main complication was macroscopic hematuria occurred only once or twice after the operation and perirenal hematoma in 1.92% of the cases.No other severe complications were found.Conclusions The biopsy clip is convenient and sterile,and can guide the biopsy device exactly and safely.The use of 18-gauge biopsy gun and the automated biopsy device in children can decrease the complication rate,which can be easily performed.
4.Cytotoxicity in Vitro of a Noval Ni-free ZrCuFeAlAg Bulk Metallic Glass.
Huifang PANG ; Cong XU ; Hua QIN ; Demin LI ; Peiyuan LI ; Bo WANG ; Shujuan ZHANG ; Qiu ZHAO
Journal of Biomedical Engineering 2015;32(2):380-386
This paper is to evaluate the biocompatibility and cytotoxicity of a new Ni-free Zr-based bulk metallic glass (BMG), Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, by comparing it with conventional Ti6Al4V alloy. According to ISO 10993-5: 1999 and GB/T 16886.5-1997 standards, Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, pure Zr and Ti6Al4V materials were extracted with surface area of sample/volume of medium ratio being 1 cm2/mL and 0.5 cm2/mL, respectively. The viabilities of MG-63 cells (Human osteosarcoma cell line) cultured in the BMG medium extracts for 1, 3 and 5 days were determined by CCK-8 assay. The cellular morphology of MG-63 cells cultured on the surface of samples for 3 days was tested through laser scanning confocal microscopy (LSCM) and scanning electron microscopy (SEM). The relative growth rate (RGR) of MG-63 cells cultured in Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and pure Zr were both more than 85%, indicating that the cytotoxicity of BMG was relatively low and met the national biomedical material eligibility standard. There was insignificant difference in the morphology of MG-63 cells cultured in the BMG medium extracts and the control group through LSCM and SEM, which showed the BMG had excellent biological compatibility. The Zr-based bulk metallic glass Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and the conventional Ti6Al4V alloy both had no obvious cytotoxicity to MG-63 cells. These results provided evidence that the new Zr-based bulk metallic glass could be potential replacement material for the orthopedic surgical implant.
Alloys
;
Biocompatible Materials
;
Cell Line
;
Glass
;
Humans
;
Microscopy, Electron, Scanning
;
Nickel
;
Titanium
;
Zirconium
5.Effects of cobalt chloride mimetic hypoxia on the proliferation, apoptosis and migration of human pancreatic cancer cell line PANC1
Liang ZHU ; Shengnan XU ; Huifang PANG ; Huizhen ZHAO ; Hua QIN ; Peiyuan LI ; Demin LI ; Qiu ZHAO
Chinese Journal of Pancreatology 2012;12(2):111-114
ObjectiveTo investigate the influence of cobalt chloride ( CoCl2 )-mimetic hypoxia on theproliferation,apoptosis and migration of human pancreatic cancer cell fine PANC1.MethodsPANC1 cells were treated with 0(control),100,200,400,800 μmol/L CoCl2 respectively for 24 h.Real-time RT-PCR and Western blot were used to determine hypoxia induced factor ( HIF)-1o mRNA and protein expression respectively,and cell counting kit-8(CCK-8) assays,flow cytometry and cell scratch test were used to examine the proliferation,apoptosis and migration of PANC1 cells,respectively.ResultsIn the control group and 100,200,400 and 800 μmol/L CoCl-2 groups,the expressions of HIF-1t mRNA were 1,1.08 ±0.12,1.12 ± 0.09,1.04±0.11,0.66 ±0.07,and the expressions of VEGF mRNA were 1,2.69±0.35,4.81 ±0.54,2.19 ± 0.21,0.79 ± 0.08,while the expressions of HIF-1 α protein were 0.23 ± 0.03,0.36 ± 0.04,1.15 ± 0.11,1.08 ± 0.09,0.44 ± 0.04; and the expressions of VEGF protein were 0.14 ± 0.02,0.12 ± 0.01,0.95 ±0.09,0.87 ±0.09,0.55 ±0.06; and cell viability rates were 100%,(98.43 ±2.88)%,(76.15 ± 0.70)%,(53.87 ±0.77)%,(35.23 ±0.67)% ; while cell apoptotic rates were (5.2 ±1.12)%,(5.74 ± 1.07)%,(6.82 ± 1.85)%,(12.09 ±3.53)%,(31.88 ±6.95)% ; the cell migration distance of PANC1 cells were (43.24 ±3.67)%,(59.46 ±5.39)%,(80.56 ±8.05)%,(63.89 ±5.96)%,(9.09 ± 1.59 ) %.Compared with those of control group,the expressions of VEGF mRNA,VEGF and HIF-1 α protein,cell migration distance showed a two-way variation ( ascending first and descending later) (P <0.05 ),and the expression of HIF-1α mRNA and cell proliferation rate was decreased in a dose-dependent manner,while the cell apoptosis was increased in a dose-dependent manner.Conclusions CoCl2 significantly inhibits the proliferation and promotes apoptosis of PANC1 cells at certain level.CoCl2 has a two-way effect on the migration of PANC1 cells,and it may be related to the direct injury of high concentration of CoCl2 on cells.
6.Clinical assessment of modified early warning score and SMART-COP on predicting mechanical ventilation in patients with severe influenza A H1N1
Jianru XU ; Liqun SHI ; Jun QIAN ; Hua LIU ; Bin QIU ; Xudong HAN ; Xiaoying HUANG
Chinese Journal of Infectious Diseases 2011;29(4):232-235
Objective To evaluate the predictive value of modified early warning score (MEWS) and SMART-COP score on mechanical ventilation in patients with severe influenza A H1N1. Methods Fifty cases diagnosed with severe influenza A H1N1 were retrospectively analyzed. The MEWS and SMART-COP score were calculated. The area under the receiver operating characteristic (ROC) curve (AUC) was evaluated using ROC curve. MEWS, SMART-COP score and AUC were analyzed by Z test. Results The AUCs of MEWS and SMART-COP score for predicting mechanical ventilation were 0. 923 and 0. 889, respectively, which were not significantly different (Z=0. 548, P =0. 584).Conclusion Both of MEWS and SMART-COP score are predictive factors of mechanical ventilation in the patients with severe influenza A H1N1.
7.Two-step Tandem Chromatography Purification of Anti-human CD80 Monoclonal Antibody 4E5 from Mouse Ascites
Hong-Bing MA ; Yu-Hua QIU ; Ran TAO ; Wen-Xiang LI ; Ying XU ; Xue-Guang ZHANG ;
China Biotechnology 2006;0(08):-
A two-step method for the purification of blocking-type anti-human CD80 monoclonal antibody 4E5 from mouse ascites was developed using anion exchange and gel filtration in combination. The ascites was first purified by anion exchange after centrifugation and filtration. The experimental parameters of sample loading and elution were optimized. The optimized loading condition was pH 8.0,50 mmol/L Tris-HCl and satisfactory results were obtained using a 0~0.5mol/L NaCl step elution. The fraction containing the protein of interest was directly loaded on gel filtration column and eluted using a 20 mmol/L phosphate buffer at pH 7.2. The purity of the obtained monoclonal antibody was up to 95% with a recovery of 61%. The purity of mAb could efficiently inhibit the growth of Daudi cells. The amplification of the method was also studied using a Bio-Scale Q5 column and the result was satisfied.
8.Isolation, culture and identification of human epidermal stem cells
cai, LIN ; xu, LUO ; guo-hua, XIN ; lai-jian, HUANG ; ze-liang, QIU
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(06):-
Objective To explore a method for isolation and culture of human epidermal stem cells. Methods Epidermis was obtained by digesting human foreskin with Dispase Ⅱ and Trypsin-EDTA.After suspension on the epidermal stem cell medium (ESCM), these single epidermis cells were inoculated onto human collagen Ⅳ-coated flasks and cultured at 37 ℃ in a humidified atmosphere containing 5% CO_2 for 10 min. The nonadherent cells were rinsed off 10 min after inoculation, and the adherent cells continued to be cultured after enriching and abstraction by type Ⅳ collagen. The cell growth was observed through inverted microscope, and the cell cloning efficiency and time of clone sustain were also detected. Immunocytochemistry was used to observe the expression of ?_1-integrin and keratin 19(K19). Keratinocytes were served as controls. Results It was revealed by histological observation that colonies were formed 24 hours after inoculation. The isolated and cultured cell cloning efficiency was higher and the time of clone sustain was longer than that of the control group. Positive expression of ?_1-integrin and K19 of cultured cells was detected by immunocytochemistry. Conclusion Adult epidermal stem cells could be successfully isolated and cultured by adhension with type Ⅳ collagen and culture with ESCM.
9.Peripapillary vessel density and the relevant factors in highly myopic eyes with peripapillary intrachoroidal cavitation
Qiu-Ying, CHEN ; Jiang-Nan, HE ; Yi-Hong, HUA ; Ying, FAN ; Xun, XU
International Eye Science 2017;17(7):1307-1312
AIM:To investigate peripapillary vessel density and its relationship with other ocular parameters in highly myopic eyes with peripapillary intrachoroidal cavitation (PICC), and to analyze risk factors for PICC.METHODS:Cross-sectional study.A total of 35 highly myopic eyes with PICC, 40 highly myopic eyes without PICC and 35 normal eyes were included in this study.All participants underwent fundus photography and spectral-domain optical coherence tomography (SD-OCT).OCT angiography was also performed to image the retinal vasculature in the peripapillary areas of different sectors, including the radial peripapillary capillaries (RPC) and optic nerve head (ONH) layer.The difference of morphology changes in optic disc and peripapillary vessel density between these three groups were compared.Correlations between peripapillary vessel density and PICC and risk factors for the presence of PICC were analyzed.RESULTS: Significant differences were found among the three groups in spherical equivalent refraction (SER), best-corrected visual acuity (BCVA), axial length, peripapillary atrophy β-zone (β-PPA) area, retinal nerve fiber layer (RNFL) thickness and the presence of tilted optic disc, posterior staphyloma and myopic maculopathy (MMD) (P<0.05).There were significant differences among the three groups in the peripapillary vessel density both in RPC (54.34±5.58, 57.54±7.44, 64.42±3.50) and ONH (51.24±7.43, 52.75±9.96, 61.25±4.15) layers (P<0.001).In highly myopic eyes, vessel density was significantly lower in eyes with PICC than in those without in inferotemporal area both in the RPC (56.76±6.62,63.84±6.02,67.52±4.78) and ONH (56.47±5.79,60.38±4.72,64.18±4.37) layers.The vessel density was significantly correlated with the presence of MMD, β-PPA area and RNFL thickness in the RPC layer, whereas correlated with the presence of MMD, PICC and RNFL thickness in the ONH layer (P<0.05).Tilted optic disc and posterior staphyloma were independent risk factors for the presence of PICC (OR=8.007, 95%CI: 2.045-31.348;OR=7.558, 95%CI: 1.398-50.026).CONCLUSION:Highly myopic eyes with PICC had relatively lower peripapillary vessel densities, especially in the temporal area, than those without.Tilted optic disc and posterior staphyloma were independent risk factors for the presence of PICC.
10.Effect of micro - incision on corneal wavefront aberration and tear film in phacoemulsification
Zong-Yan, SONG ; Feng-Hua, CHEN ; Fang, CHENG ; Ai-Min, YAN ; Xu, QIU ; Xue-Fei, LOU
International Eye Science 2014;(12):2207-2209
AlM: To investigate the effect of endocapsular phacoemulsification cataract extraction and intraocular lens (lOL) implantation with a 1. 8mm or 3. 0mm clear corneal incision on total root mean square ( RMS ) value of the cornea, corneal astigmatism, spherical aberration, coma, trefoil and tear film.
METHODS:ln a prospective study, 156 age- related patients ( 196 eyes ) were randomly distributed into two groups. 1. 8mm-group comprised 94 eyes that had a silicone lOL inserted through a 1. 8mm sutureless clear corneal incision, while, 3. 0mm- group comprised 102 eyes through a 3. 0mm clear corneal incision. Postoperatively, the changes in the total RMS value of the cornea, corneal astigmatism, spherical aberration, coma, trefoil and tear film at 1wk, 1 and 3mo were determined respectively.
RESULTS:ln both groups, postoperatively at 1wk,there were statistically significant differences ( P<0. 05 ) in the total RMS value of the cornea, corneal astigmatism, spherical aberration, coma, trefoil and tear film, while, there were statistically minimal differences ( P< 0. 05 ) between 1. 8mm-group and 3. 0mm-group at 1mo, but were not statistically significantly different ( P > 0. 05 ) between two groups at 3mo postoperative.
CONCLUSlON:This study confirms that incision size has strong impact on the corneal higher-order aberrations, especially, 3. 0mm incision caused significant differences in the total RMS value of cornea, corneal astigmatism, spherical aberration, coma, trefoil and tear film compared with 1. 8mm micro-incision, therefore, micro-incision is very beneficial for clinical use in phacoemulsification.