1.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
XU Xinyi ; WEI Shifeng ; ZHANG Qiming ; HE Langchong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):045-050
Objective: To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Methods: Introduce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Results: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guidelines of the ICH Q series, and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety, efficacy, and quality controllability is further increased.
Conclusion: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China’s drugs to go international, standardized testing technology support for achieving full process quality control, and better meet the needs of drug research and development, production, quality control, and supervision in China.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Molecular characterization of FGFR fusion in a large real-world population and clinical utility of bidirectional fusion.
Xinyi ZHANG ; Jing ZHAO ; Ling MA ; Yitong TIAN ; Jiaguang ZHANG ; Hejian ZHENG ; Junling ZHANG ; Runyu HE ; Luhang JIN ; Jing MA ; Mengli HUANG ; Xiao LI ; Xiaofeng CHEN
Chinese Medical Journal 2025;138(12):1510-1512
8.Comprehensive management of tophaceous wound.
Guoyu HE ; Shuliang LU ; Xinyi LU ; Yingkai LIU
Journal of Zhejiang University. Medical sciences 2025;54(5):611-619
Tophaceous wound represent a severe complication of end-stage gout, characterized by the deposition of monosodium urate (MSU) crystals leading to localized tissue ischemia, chronic inflammation, and non-healing ulcers. The pathological mechanism involves the formation of MSU crystals under persistent hyperuricemia, inflammatory encapsulation, and mechanical compression of the vascular system due to tophus enlarge-ment, ultimately resulting in chronic non-healing ulcers. This article consolidates current evidence to outline an integrated management strategy for such wounds, combining systemic metabolic control with localized interventions. Effective treatment depends on maintaining serum uric acid levels below 300 μmol/L through urate-lowering agents, including conventional drugs and novel urate transporter 1 inhibitors such as AR882, complemented by anti-inflammatory medications such as nonsteroidal anti-inflammatory drugs and glucocorticoids to alleviate pain and reduce inflammation. Topical agents and advanced dressings are utilized to support healing and manage exudate. Debridement, which encompasses sharp, ultrasonic, and micro-techniques, is essential for removing necrotic tissue and MSU deposits, with efficacy assessed via local uric acid monitoring. Surgical reconstructions, including skin flap grafting and tendon or ligament reconstruction, are indicated for significant tissue loss or functional impairment. Long-term management emphasizes continuous metabolic control, personalized rehabilitation, and lifestyle modification. The comprehensive treatment of tophaceous wounds requires multidisciplinary collaboration to balance local repair and systemic regulation for improved prognosis. Future research directions include gene therapy to regulate purine metabolism and artificial intelligence-assisted personalized treatment plans, to achieve precision medicine for tophaceous wounds.
Humans
;
Wound Healing
;
Gout/therapy*
;
Uric Acid/blood*
;
Debridement
9.The role of home medical and nursing care team in the service system for home disabled elderly
Yao JIANG ; Jing ZHANG ; Xinyi WU ; Qiaolu LI ; Yunying ZHANG ; Yan HE ; Nie ZHANG
Journal of Shenyang Medical College 2024;26(2):118-121,135
Objective:To analyze the role of home medical and nursing care team in the service system of home disabled elderly.Methods:A total of 100 home disabled elderly managed by our hospital from Jan to Dec 2022 were enrolled,and the home medical and nursing care teams strengthened home rehabilitation nursing services and guidance,health risk guidance,psychological support,and nutrition guidance and intervention.The management results before and after intervention was compared.Results:After intervention,the mastery of health risk management,psychological support and nutritional intervention,and the compliance rate of rehabilitation exercise were higher than those before intervention(P<0.05).The incidence of pressure injury was lower than that before intervention(P<0.05).After intervention,the satisfaction rate of the elderly to the work of the home medical and nursing care team was 95%.Conclusion:Home medical and nursing care team plays an important role in the nursing service system of the disabled elderly,and play an important role in the construction of a three-level service health management system of institution-community-home.
10.RAS-selective lethal small molecule 3 inhibits the fibrosis of pathological scar fibroblasts
Jiangyong SHEN ; Xi HE ; Yuting TANG ; Jianjun WANG ; Jinyi LIU ; Yuanyuan CHEN ; Xinyi WANG ; Tong LIU ; Haoyuan SUN
Chinese Journal of Tissue Engineering Research 2024;28(8):1168-1173
BACKGROUND:Abnormal extracellular matrix accumulation and excessive proliferation of fibroblasts are the main manifestations of pathological scars.Excessive proliferation of fibroblasts leads to the production of large amounts of collagen-based extracellular matrix.Therefore,to investigate the role of fibroblast fibrosis in the formation of pathological scar will provide a new idea for revealing the mechanism of pathological scar and biological therapy. OBJECTIVE:To investigate the effect of RAS-selective lethal small molecule 3(RSL3)on the fibrosis of human pathological scar fibroblasts. METHODS:Then cases of pathological scar tissue and normal skin tissue samples from the same individuals,provided by the Department of Burn Plastic Surgery,General Hospital of Ningxia Medical University,were collected.Fibroblasts of human pathological scar and human normal skin were extracted and used in the following experiments.The general condition of the pathological scar tissue and the normal skin tissue was detected by hematoxylin-eosin staining.The appearance of fibroblasts from pathological scar and normal skin were observed by inverted microscope.The fibroblasts were verified by immunofluorescence assay.The cells were treated with different concentrations of RSL3(1,3,5,7,9,11,13 μmol/L).The inhibitory concentration of RSL3 on fibroblasts was detected by cell counting kit-8.Control group(without treatment)and RSL3 intervention group(treated with 7 μmol/L RSL3 for 24 hours)were set up.The mRNA and protein expressions of glutathione peroxidase 4,type Ⅰ collagen,type Ⅲ collagen and α-smooth muscle actin were detected by Qrt-PCR and western blot,respectively.Level of malondialdehyde in cells was detected.The residual scratch area was measured by cell scratch test after 24 hours to calculate the percentage of residual scratch area. RESULTS AND CONCLUSION:The expression of glutathione peroxidase 4 in the pathological scar group was higher than that in the normal skin group(Mrna:t=3.252,P<0.01;protein:t=5.075,P<0.01).The expression of glutathione peroxidase 4 in the pathological scar fibroblast group was higher than that in the normal skin fibroblast group(Mrna:t=10.32,P<0.01;protein:t=26.22,P<0.01).Compared with the control group,the expression of glutathione peroxidase 4 was decreased(Mrna:t=2.798,P<0.05;protein:t=4.643,P<0.01),the content of malondialdehyde was increased(t=2.917,P<0.05),the expression of type Ⅰ collagen(Mrna:t=15.84,P<0.01;protein:t=4.610,P<0.01),type Ⅲ collagen(Mrna:t=28.86,P<0.01;protein:t=7.713,P<0.01)and α-smooth muscle actin(Mrna:t=2.671,P<0.05;protein:t=7.417,P<0.01)were decreased in the RSL3 intervention group.Compared with the control group,the migration ability was weakened in the RSL3 intervention group(t=14.06,P<0.01).To conclude,RSL3 can inhibit the expression of glutathione peroxidase 4 and then inhibit the ability of fibrosis and migration of pathological scar fibroblasts.

Result Analysis
Print
Save
E-mail