1.The research progress of Treacher Collins syndrome.
Pu WANG ; Xinmiao FAN ; Yue FAN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2016;30(4):333-338
Treacher Collins syndrome (TCS, OMIM 154500), also known as Franceschetti-Klein syndrome, is a rare disorder that affects the first and second branchial arches. The estimated incidence is 1/50 000 live births. Mutations in TCOF1 (78%-93%) and POLR1C or POLR1D (8%) cause the disease. Most of TCS cases are inherited in a dominant pattern, while a small proportion are inherited in a recessive pattern. TCS has a variable phenotype with typical clinical characteristics including downward-slant of palpebral fissure, malar hypoplasia, mandibular hypoplasia and microtia. TCS management is a multidisciplinary affair, as interventions range from reconstructive to psychosocial. For hearing rehabilitation, TCS patients may have the choices of BAHA, ponto, vibrant soundbridge or bonebridge implantation. In this review, we summarize the TCS clinical malformations, diagnosis, genetics, management and auditory rehabilitation.
DNA-Directed RNA Polymerases
;
genetics
;
Facial Bones
;
abnormalities
;
Humans
;
Mandibulofacial Dysostosis
;
diagnosis
;
genetics
;
rehabilitation
;
Mutation
;
Nuclear Proteins
;
genetics
;
Phosphoproteins
;
genetics
2.Application of cardiac pacemaker in laparoscopic cholecystectomy—an analysis of 215 cases
Dengqun SUN ; Renhua GONG ; Yanjun SUN ; Binquan CAO ; Guoli TIAN ; Xingguo ZHONG ; Xinmiao HE ; Jun CAI ; Yulin FAN ; Baoqiang CAO ; Shitao JIANG ; Zhenyu DAN ; Kailang LI
Chinese Journal of Digestive Endoscopy 2012;29(11):628-630
ObjectiveTo evaluate the influence of electrotome on permanent and temporary cardiac pacemaker in laparoscopic cholecystectomy ( LC),and the application of cardiac pacemaker to the cases of cholecystolithiasis combined with bradyarrhythmia.MethodsClinical data of 215 patients with permanent or temporary cardiac pacemaker who underwent were studied for the preoperative and postoperative variation of pacemaker function,and for the influence of electricity coagulation during the operation on cardiac pacemaker function.ResultsLC was successfully completed in all 215 patients.The function of cardiac pacemaker was not obviously interfered during the operation,and the parameters of cardiac pacemaker did not remarkably change after the operation.ConclusionCardiac pacemaker is slightly interfered when electrotome and electrocoagulation were used in LC; LC is feasible and safe for patients with bradyarrhythmia by placement of cardiac pacemaker.
3.Application of Third-generation Dual-source CT for Ultra-high Resolution Temporal Bone Imaging Using Automated Tube Voltage Adaptation in Children with Hearing Impairment.
Yuanli ZHU ; Yu CHEN ; Xinmiao FAN ; Huadan XUE ; Xiaowei CHEN ; Man WANG ; Yun WANG ; Zhuhua ZHANG ; Zhengyu JIN
Acta Academiae Medicinae Sinicae 2017;39(1):12-16
Objective To evaluate the radiation dose and image quality of the third-generation dual-source CT using automated tube voltage adaptation (CARE kV) in temporal bone scanning in pediatric patients with hearing impairment. Methods Totally 27 children with hearing impairment less than 18 years old were randomly divided into two groups:Group A (n=14),examined with CARE kV (reference with 100 kV and 214 mA)and sinogram-affirmed iterative reconstruction;and Group B (n=13),examined with CARE kV (reference with 100 kV and 171 mA)and advanced modeled iterative reconstruction. The scan range was from eyebrow to the end of the mastoid process. CT values and image noise were measured.The signal to noise ratio (SNR)was calculated. Subjective image quality was assessed by two radiologists and later in a consensus reading. Results There was no significant difference in CT value,image noise,and SNR between these two groups (all P>0.05). Also,the subjective scores of the 10 anatomical structures showed no significant difference (all P>0.05). The CT dose index volume and dose-length product were (11.62+1.92)mGy and (106.92+37.48)mGy·cm,respectively,in group B and (21.28+2.19)mGy (t=12.15,P<0.001)and (229.65+56.26)mGy·cm (t=6.62,P<0.001)in group A,decreased by 45% and 53%. Conclusion Compared with the second-generation dual-source CT,the third-generation dual-source CT for the scanning of temporal bone with CARE kV can ensure image quality and reduce radiation dose.
Child
;
Hearing Loss
;
diagnosis
;
Humans
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
;
Temporal Bone
;
diagnostic imaging
;
Tomography, X-Ray Computed
;
methods
4. Selection and application in the approach of Bonebridge implantation for bilateral congenital malformation of external and middle ear: selection and application
Yue FAN ; Xinmiao FAN ; Xiaomin NIU ; Tengyu YANG ; Xin XIA ; Xiaowei CHEN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2021;35(7):602-607
5.Genetic Analysis of a Family with Mohr-Tranebjaerg Syndrome
Ruzhen GAO ; Yue FAN ; Xinmiao FAN ; Tengyu YANG ; Wenjie SONG ; Xiaowei CHEN
JOURNAL OF RARE DISEASES 2023;2(1):50-54