1.Asymmetric osteotomy via posterior adjacent vertebrae in treating traumatic thoracolumbar kyphotic scoliotic deformity
Xingwei PU ; Chunshan LUO ; Bing QIU ; Chon WANG ; Yuqiang CAI ; Tingsheng LU ; Shudan YAO ; Guoquan ZHAO
Chinese Journal of Trauma 2018;34(8):689-695
Objective To investigate the clinical efficacy of asymmetric osteotomy via posterior adjacent vertebrae in the treatment of traumatic thoracolumbar kyphotic scoliotic deformity.Methods A retrospective case series study was conducted on the clinical data of 16 patients with traumatic thoracolumbar kyphotic scoliotic deformity admitted to our department from January 2012 to January 2017.There were 10 males and six females,aged (42.5 ±7.6) years (range,20-62 years).According to the location of injured vertebrae,there were two patients with T11,five with T12,six with L1,and three with L2,all of which had scoliosis deformity and obvious low back pain.All patients underwent asymmetric osteotomy via posterior adjacent vertebrae.The operation time and intraoperative bleeding were recorded.The imaging parameters such as kyphosis Cobb angle,scoliosis Cobb angle,distance between C7 plumbline and central sacral vertebral line (C7-CSVL),and distance between C7 plumbline and sagittal vertical axis (SVA) were measured before and after operation.At the same time,the visual analogue scale (VAS),Oswestry dysfunction index (ODI),and SRS-22 scale were used to evaluate the clinical efficacy.The AISA score was used to evaluate the neurological function recovery before and after operation.Results All patients were followed up for (26.3 ± 16.8) months (range,15-65 months).The operation time was (6.0 ± 1.4) hours (range,4.5-9.0 hours),and the intraoperative bleeding was (900.5 ± 360.8)ml (range,800-1600 ml).The kyphosis Cobb angle was improved from (70.3 ± 9.8) °before operation to (12.2 ± 2.9) ° after operation (P < 0.01).The scoliosis Cobb angle was improved from (47.6 ± 11.6) ° before operation to (4.0 ± 0.9) ° after operation (P < 0.01).The C7-CSVL decreased from preoperative (3.1 ±0.8)cm to postoperative (1.2 ±0.4)cm (P <0.01),and the SVA decreased from preoperative (5.0 ± 0.9) cm to postoperative (2.9 ± 0.5) cm (P < 0.01).No severe complications such as spinal cord and nerve injury occurred.The VAS decreased from preoperative (6.8 ± 1.0) to (1.9 ± 0.9) points at the last follow up.The ODI decreased from (54.6 ± 4.2) % before operation to (8.1 ± 2.5) % at the last follow up.The SRS-22 score was increased from (64.6 ±7.5) points before operation to (87.4 ± 3.2) points at the last follow-up.In terms of the ASIA classification,two patients were improved from grade C to grade D after operation,and six patients were improved from grade D to grade E.Conclusion Asymmetric osteotomy via posterior adjacent vertebrae is safe and effective in the treatment of traumatic thoracolumbar scoliosis,with high correction rate of scoliosis and kyphosis at the same time.
2.Research on application of advanced 3D printing navigation templates in assisting placement of atlantoaxial pedicle screw
Xingwei PU ; Chunshan LUO ; Bing QIU ; Guoquan ZHAO ; Tingsheng LU ; Shudan YAO ; Qilin CHEN ; Jianwen YANG
Chinese Journal of Orthopaedics 2017;37(24):1511-1520
Objective To explore the accuracy and clinical efficacy of advanced 3D printing navigation templates in assisting placement of atlantoaxial pedicle screw.Methods A retrospective analysis was carried out on 49 cases of patients with atlanto-axial vertebral fractures and dislocations between June 2013 and June 2016,and all of them were given posterior incision,reduction and internal fixation of atlantoaxial pedicle screw.The patients were divided into advanced 3D printing navigation template group (14 cases),early 3D printing navigation template group (16 cases),and routine pedicle screw placement group (19 cases).Atlantoaxial CT data of patients in advanced 3D printing navigation template group and early 3D printing navigation template group were input into Mimics 17.0,then advanced 3D printing navigation template group and early 3D printing navigation which were used in clinic surgery were designed and printed.The relationship between positions of pedicle screw with the pedicle and bone cortex in plain CT image was observed after operation.The quality of the screw position was assessed and the accuracy of three kinds of screwing methods was compared.The accuracy of the screwing angle was assessed by comparing with the differences between the preoperative designed channel inclination angle and postoperative actual screwing angle.Three groups were compared for differences between operation time,intraoperative blood loss,and scores of cervical nerve scale and visual analogue scale (VAS) of neck and shoulder pain by Japanese Orthopaedic Association (JOA).Results All 49 cases of patients successfully completed the surgery.Patients of the routine pedicle screw placement group,early 3D group and advanced 3D group correspond operation time for 141.2±20.7 min,112.5±12.1 min and 103.1±10.4 min,intraoperative blood loss for 314.0±81.4 ml,243.6±71.2 ml and 181.0+59.1 ml;total accuracy of screwing for 75.0% (54/72),93.75 % (60/64) and 96.43 % (54/56).There were statistically significant differences among the routine group,3D group and advanced 3D group in the mentioned programs.There were no statistical differences between advanced 3D group and 3D group in the inclination angle and head tilt angle with the pre-designed values,while there was statistically significant difference between the routine group and the pre-designed value.The accuracy of the inclination angle and bead tilt angle screwing angle were obviously superior in the advanced 3D group and early 3D group to that of the routine group.There were statistically significant differences between preoperative with postoperative VAS scores and JOA scores in the same group,while there were no statistically significant differences among groups in JOA.But there was statistically significant difference between the routine group and the advanced 3D in VAS,and there was no statistically significant difference between the routine pedicle screw placement group and the early 3D in VAS.All three groups of patients had bony fusion of atlantoaxial vertebral body,without loosening,dislocation and fracture of the internal fixators.Conelusion Advanced 3D printing templates in assisting the surgical treatment for atlantoaxial fracture and dislocation can improve the accuracy of pedicle screwing and safety of the surgery,reduce the surgery risk,and obtain satisfied clinical curative effects.
3.Xenogenic bone with chitosan / norvancomycin sustained-release system for treatment of infectious bone defects in rabbits
Chunshan LUO ; Chao YANG ; Yu SUN ; Chuan YE ; Tingsheng LU ; Shudan YAO ; Xingwei PU ; Jianwen YANG ; Guoquan ZHAO ; Xiaobin TIAN
Chinese Journal of Trauma 2018;34(1):68-73
Objective To investigate the effects of xenogenic bone with chitosan/norvancomycin sustained-release biomaterials in treating infectious bone defects in rabbits.Methods Xenogenic bone with chitosan/norvancomycin sustained-release biomaterials was made by electrospinning technique.Rabbit infectious bone defect models were made by Methicillin-resistant Staphylococcus aureus.A successful model was evaluated with the standard of more than three points in Norden score assessment.All models were divided into two groups by random number table method,with eight models in each.The control group was treated with surgical debridement,and the experimental group was implanted with bone particles of xenogenic bone with chitosan/norvancomycin sustained-release system after debridement.Postoperatively,general conditions,X-ray,histological results of HE staining,and bacteriological examination results of the rabbits were observed.Results X-ray showed significant bone defects,sequestration,periosteal reaction,and soft tissue swelling after one month of modeling,with Norden score of (3.84 ± 0.52) points.The general conditions were good and the sinus tracts were healed in experimental group after two months of treatment.The control group demonstrated generally poor conditions with swollen sinus and purulent discharge.Two rabbits were died of sepsis.The pathological scores of tibial were (0.41 ± 0.08) points in experimental group,and (3.27 ± 0.26) points in control group by gross observation.The pathological score of experimental group was significantly lower than control group(P < 0.05).The bone defects were basically repaired in experimental group.The longest diameter of bone defect in experimental group was (0.11 ± 0.02)cm,significantly smaller than (0.48 ± 0.06) cm in control group (P < 0.05).There were no obvious signs of osteomyelitis and the bone defects were well repaired in experimental group.Periosteal reaction,soft tissue swelling,a substantial number of bone destruction,and sequestration were observed in control group.The Norden score was (1.32 ± 0.23) points in experimental group,lower than (5.21 ± 0.48) points in control group(P < 0.05).HE staining showed a large amount of trabecular bone formation,bone cell formation,and fibrous hyperplasia in experimental group,with no obvious signs of infection.On the other hand,infiltration of inflammatory cells,necrotic tissue,and sequestration were observed in control group.The histological score was(0.61 ± 0.10) points in experimental group,lower than (4.21 ± 0.41) points in control group (P <0.05).The negative rate of bacterial culture in experimental group was 33%,lower than 100% in control group (P < 0.05).Conclusion Xenogenic bone with ehitosan/norvancomycin sustained-release biomaterials has excellent effect in infection clearance and bone defect reparation in treatment of infectious bone defects in rabbits.
4.Application of 5-point positioning point-contact pedicle navigation template in the case of scoliosis and complex pedicle
Lihang WANG ; Tingsheng LU ; Qiling CHEN ; Shudan YAO ; Xingwei PU ; Linsong JI ; Guoquan ZHAO ; Beiping OUYANG ; Bin ZHANG ; Zaisong YANG ; Chunshan LUO
Chinese Journal of Tissue Engineering Research 2024;28(18):2859-2864
BACKGROUND:The pedicle navigation template has many advantages,but there are still some problems.For example,poor soft tissue dissection leads to poor adhesion of the pedicle navigation template,resulting in screw path deviation;careful dissection of soft tissue to fit the pedicle navigation template leads to prolonged surgery time and increased bleeding;the design of the pedicle navigation template cannot predict the vertebral rotation and the impact of body position changes,resulting in the poor fitting. OBJECTIVE:To explore the utility of a new 5-point positioning point-contact pedicle navigation template in the case of scoliosis and complex pedicle. METHODS:A total of 20 patients with scoliosis and complicated pedicle admitted to the Department of Spinal Surgery,Guizhou Hospital,Beijing Jishuitan Hospital from February 2020 to February 2023 were selected for scoliosis orthopedics.During the operation,the 5-point positioning point-contact pedicle navigation template was used to guide the screws.According to the inclusion and exclusion criteria,34 cases were matched as the empirical nail placement group,and conventional barehanded nail placement was performed.The time of placement,the amount of bleeding,the number of fluoroscopies,the number of manual diversions,the level and accuracy of pedicle screws,the complications of placement,and the rate of correction of main curvature were compared between the two groups. RESULTS AND CONCLUSION:(1)There were no significant differences in sex,age,coronal Cobb's angle of the main curvature,bending Cobb's angle of the main curvature,pedicle variation,apex rotation,fusion segment,number of screws,level of screws,accuracy of screws,and rate of correction of main curvature between the navigation template group and the empirical nail placement group(P>0.05).(2)Compared with the empirical nail placement group,the navigation template group had more advantages in time of placement(P=0.034),amount of bleeding(P=0.036),number of fluoroscopies(P=0.000)and number of manual diversions(P=0.021).(3)There were 0 cases of screw-related complications in both groups.(4)In conclusion,the 5-point positioning point-contact 3D printing pedicle navigation template has a claw-like structure.It can firmly adapt to various deformities of the lamina articular process,avoid drift,and accurately place the screws.It has a point-like contact lamina structure to avoid extensive and complete dissection of the posterior structure,and reduce bleeding,operation time,and trauma.Pre-designed screw entry points and directions can reduce the number of fluoroscopy and operation time.Segmental design can avoid discomfort due to changes in anesthesia position.The operation is simple and the accuracy of screw placement is high.
5.Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery.
Lihang WANG ; Qian TANG ; Qiling CHEN ; Tingsheng LU ; Shudan YAO ; Xingwei PU ; Linsong JI ; Chunshan LUO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):700-705
OBJECTIVE:
To explore the effectiveness of a new point contact pedicle navigation template (referred to as "new navigation template" for simplicity) in assisting screw implantation in scoliosis correction surgery.
METHODS:
Twenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups ( P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated.
RESULTS:
Both groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups ( P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group ( P<0.05). There was no complications related to screws implantation during or after operation in the two groups.
CONCLUSION
The new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.
Humans
;
Orthopedic Procedures
;
Pedicle Screws
;
Retrospective Studies
;
Scoliosis/surgery*
;
Spinal Fusion/methods*
;
Spine
;
Surgery, Computer-Assisted/methods*