1.Regulatory effect of Diwu Yanggan Decoction on lysoglycerophospholipids in circulating exosomes in a mouse model of nonalcoholic fatty liver disease
Guangya CHEN ; Xingliang XIANG ; Zhaoxiang ZENG ; Rongzeng HUANG ; Shuna JIN ; Mingzhong XIAO ; Chengwu SONG
Journal of Southern Medical University 2024;44(7):1382-1388
Objective To evaluate the regulatory effect of Diwu Yanggan(DWYG)Decoction on lysoglycerophospholipids(Lyso-GPLs)in circulating exosomes in a mouse model of nonalcoholic fatty liver disease(NAFLD).Methods Circulating exosomes isolated from mouse serum by size exclusion chromatography were morphologically characterized using transmission electron microscope and examined for surface markers CD9,CD63 and TSG101 using Western blotting.Twenty-four male Kunming mice were randomized into 3 groups for normal feeding(control,n=8)or high-fat diet feeding for 1 week to induce NAFLD,after which the latter mice were given DWYG decoction(treatment group,n=8)or normal saline(model group,n=8)by gavage for 4 weeks.After the last treatment,blood samples were collected from the mice for testing serum TC,HDL-C,LDL-C,ALT and AST levels and isolating circulating exosomes.Using multivariate statistical analysis based on targeted metabolomics strategy,the potential biomarkers for Lyso-GPLs in the exosomes were screened.Results The isolated exosomes about 100 nm in size had a typical saucer-like structure with distinct double-layer membranes and a mean particle size of 137.5 nm and expressed the specific surface marker proteins CD9,CD63 and TSG101.The mouse models of NAFLD had significantly increased serum levels of TC,HDL-C,LDL-C and AST and lowered serum ALT level.A total of 43 Lyso-GPLs with significant reduction after DWYG Decoction treatment were identified in NAFLD mice.Conclusion DWYG Decoction can regulate Lyso-GPLs in circulating exosomes in NAFLD mice,which provides a new clue for studying the therapeutic mechanism of DWYG Decoction for liver disease.
2.Comparative Evaluation of Encephalon State Index and Bispectral Index in Monitoring the Depth of Anesthesia during the Surgical Anesthesia Stage
Sanchao LIU ; Nong YAN ; Xingliang JIN ; Xianliang HE ; Ke XIAO ; Hanyuan LUO ; Huacheng LUO ; Yongjun ZENG ; Jie QIN ; Yinbing YANG ; Yalan LI ; Lan GAO
Chinese Journal of Medical Instrumentation 2024;48(6):639-644
Objective Evaluate the performance of the encephalon state index(ESI)in depth of anesthesia monitoring during clinical surgery,compared with the bispectral index(BIS).Methods ESI and BIS data were collected from 60 patients in a single-center clinical trial to compare their efficacy in measuring the depth of anesthesia.Results Consistency analysis revealed mean differences and standard deviations of-0.18±5.42 and-0.11±6.51 between ESI and BIS for awake and anesthetized states,respectively.Correlation analysis showed a correlation coefficient of 0.92 throughout the operative period.Prediction probability analysis indicated that both ESI and BIS had prediction probabilities of 0.97,effectively predicting anesthesia status.Conclusion ESI and BIS show good equivalence in monitoring depth of anesthesia during clinical surgery,which meet the requirements of clinical anesthesia.
3.Regulatory effect of Diwu Yanggan Decoction on lysoglycerophospholipids in circulating exosomes in a mouse model of nonalcoholic fatty liver disease
Guangya CHEN ; Xingliang XIANG ; Zhaoxiang ZENG ; Rongzeng HUANG ; Shuna JIN ; Mingzhong XIAO ; Chengwu SONG
Journal of Southern Medical University 2024;44(7):1382-1388
Objective To evaluate the regulatory effect of Diwu Yanggan(DWYG)Decoction on lysoglycerophospholipids(Lyso-GPLs)in circulating exosomes in a mouse model of nonalcoholic fatty liver disease(NAFLD).Methods Circulating exosomes isolated from mouse serum by size exclusion chromatography were morphologically characterized using transmission electron microscope and examined for surface markers CD9,CD63 and TSG101 using Western blotting.Twenty-four male Kunming mice were randomized into 3 groups for normal feeding(control,n=8)or high-fat diet feeding for 1 week to induce NAFLD,after which the latter mice were given DWYG decoction(treatment group,n=8)or normal saline(model group,n=8)by gavage for 4 weeks.After the last treatment,blood samples were collected from the mice for testing serum TC,HDL-C,LDL-C,ALT and AST levels and isolating circulating exosomes.Using multivariate statistical analysis based on targeted metabolomics strategy,the potential biomarkers for Lyso-GPLs in the exosomes were screened.Results The isolated exosomes about 100 nm in size had a typical saucer-like structure with distinct double-layer membranes and a mean particle size of 137.5 nm and expressed the specific surface marker proteins CD9,CD63 and TSG101.The mouse models of NAFLD had significantly increased serum levels of TC,HDL-C,LDL-C and AST and lowered serum ALT level.A total of 43 Lyso-GPLs with significant reduction after DWYG Decoction treatment were identified in NAFLD mice.Conclusion DWYG Decoction can regulate Lyso-GPLs in circulating exosomes in NAFLD mice,which provides a new clue for studying the therapeutic mechanism of DWYG Decoction for liver disease.
4.Development of Vital Signal Monitoring System Based on Accelerometer.
Jian CEN ; Xingliang JIN ; Sanchao LIU ; Huacheng LUO ; Nong YAN ; Xianliang HE ; Yumei MA ; Hanyuan LUO ; Jie QIN ; Yinbing YANG
Chinese Journal of Medical Instrumentation 2023;47(6):602-607
OBJECTIVE:
Reduce the number of false alarms and measurement time caused by movement interference by the sync waveform of the movement.
METHODS:
Vital signal monitoring system based on motion sensor was developed, which collected and processed the vital signals continuously, optimized the features and results of vital signals and transmitted the vital signal results and alarms to the interface.
RESULTS:
The system was tested in many departments, such as digestive department, cardiology department, internal medicine department, hepatobiliary surgery department and emergency department, and the total collection time was 1 940 h. The number of false electrocardiograph (ECG) alarms decreased by 82.8%, and the proportion of correct alarms increased by 28%. The average measurement time of non-invasive blood pressure (NIBP) decreased by 16.1 s. The total number of false respiratory rate measurement decreased by 71.9%.
CONCLUSIONS
False alarms and measurement failures can be avoided by the vital signal monitoring system based on accelerometer to reduce the alarm fatigue in clinic.
Humans
;
Monitoring, Physiologic
;
Electrocardiography
;
Arrhythmias, Cardiac
;
Blood Pressure
;
Accelerometry
;
Clinical Alarms
5.Research Progress of Physiologic Parameters Monitoring Technology for Critical Neonates.
Ke XIAO ; Mengxing LIU ; Xingliang JIN ; Xianliang HE ; Hexian ZHONG ; Ye LI
Chinese Journal of Medical Instrumentation 2022;46(1):68-75
Physiological parameter monitoring is essential to medical staff to evaluate, diagnose and treat patients in neonatal intensive care unit (NICU). Monitoring in NICU includes basic vital signal monitoring and functional monitoring. Basic vital signal monitoring (including ECG, respiration, SpO2, blood pressure, temperature) is advanced and focus on study of usability, continuity and anti-interference. Functional monitoring (including respiratory function, circulatory function, cerebral function) still focus on study of monitoring precision and reliability. Meanwhile, video monitoring and artifact intelligence have presented well performance on improving monitoring precision and anti-interference. In this article, the main parameters and relevant measurement technology for monitoring critical neonates were described.
Humans
;
Infant, Newborn
;
Intensive Care Units, Neonatal
;
Monitoring, Physiologic
;
Reproducibility of Results
;
Respiration
;
Technology
;
Vital Signs
6.Study on the value of pulse oximetry plethysmographic waveform derived parameters on the quality of cardiopulmonary resuscitation
Quan YUAN ; Cheng WANG ; Jie QIN ; Xianliang HE ; Xingliang JIN ; Fei ZHANG ; Jian CEN ; Lei WANG
Chinese Journal of Emergency Medicine 2022;31(3):364-367
Objective:Pulse oximetry plethysmographic (POP) waveform to indicate the patient's perfusion status and the quality of resuscitation has been affirmed. The POP waveform is obtained by a non-invasive monitoring method, and its clinical feasibility during CPR is better than that of invasive monitoring technologies. This study aimed to analyze the three parameters derived from POP waveform: CPR quality index (CQI), perfusion index (PI), and chest compression fraction (CCF) in evaluating the CPR quality and ROSC possibility.Methods:A prospective descriptive study was conducted on 74 CPR patients who were divided into the ROSC group and non-ROSC group according to their resuscitation results. The clinical data were extracted from patient monitor, the distribution and changes of the three parameters during CPR were collected, and their value of evaluating resuscitation outcome were analyzed.Results:At the end stage of resuscitation, there were statistically significant differences in the three parameters between the two groups ( P<0.05). In addition, CQI was significantly more capable in evaluating the possibility of ROSC than PI and CCF ( P<0.05). Conclusions:CQI, PI and CCF derived from POP waveform can all be applied to evaluate CPR quality and ROSC possibility. CQI has higher prognosis value than PI and CCF.
7.Review of Physiological Parameters Monitoring Technology in the ICU.
Mengxing LIU ; Yiwen LIN ; Ke XIAO ; Bailei SUN ; Xianliang HE ; Xingliang JIN ; Zehui SUN ; Hexian ZHONG ; Ye LI ; Yiyu ZHUANG
Chinese Journal of Medical Instrumentation 2021;45(6):662-669
Physiological parameters monitoring is essential to direct medical staff to evaluate, diagnose and treat critical patients quantitatively. ECG, blood pressure, SpO2, respiratory rate and body temperature are the basic vital signs of patients in the ICU. The measuring methods are relatively mature at present, and the trend is to be wireless and more accurate and comfortable. Hemodynamics, oxygen metabolism and microcirculation should be taken seriously during the treatment of acute critical patients. The related monitoring technology has made significant progress in recent years, the trend is to reduce the trauma and improve the accuracy and usability. With the development of machine vision and data fusion technology, the identification of patient behavior and deterioration has become hot topics. This review is focused on current parameters monitoring technologies, aims to provide reference for future related research.
Humans
;
Intensive Care Units
;
Monitoring, Physiologic
;
Oxygen Saturation
;
Technology
;
Vital Signs
8.The Embryo Toxicity Research of Manufacturing Water of Medical Device of in Vitro Fertilization Technology.
Qianqian HAN ; Xu JI ; Lu CHANG ; Xingliang JIN ; Chunren WANG ; Jingli LI
Chinese Journal of Medical Instrumentation 2020;44(5):439-442
Water is an important component in liquid medical device products for human assisted reproductive technology. Water traits, conductivity, microbial limits, total organic carbon, easy oxides, heavy metal content, bacterial endotoxin and other indicators have an important impact on sperm, egg and embryo development in vitro, so for such products, the quality of water control is extremely important. The production water for producing such products is generally prepared by MilliQ purification system. In this research, we used four different types of water to fabricate the IVF liquids. It included deionized reverse osmosis water, ultra purified water and ultra purified water without endotoxin or nucleic acid, and compared with tap water. The in vitro rat embryo test system was used to study the embryotoxicity of this four different culture liquid production waters. From the result, the group of the super purified water without endotoxin and nucleic acid has the best result of the embryo formation rate, the number of total cell number and the inner cell number. This study proved the importance of removing endotoxin and nucleic acid from the water used for the preparation of the liquid products for assisted reproduction, and provided the basis for the selection of water quality for the liquid products for assisted reproduction.
Animals
;
Embryonic Development
;
Equipment Contamination
;
Fertilization in Vitro/instrumentation*
;
Humans
;
Rats
;
Reproductive Techniques, Assisted
;
Research
;
Technology
;
Water
9.AIDS knowledge,attitudes and practices among freshmen of a university in Hangzhou
Yan LUO ; Gang ZHAO ; Xiting LI ; Jie JIN ; Hong WU ; Xingliang ZHANG ; Jianming DING ; Ke XU ; Wenjie LUO ; Jia-nyu YOU
Journal of Preventive Medicine 2019;31(7):673-677
Objective:
To understand the AIDS knowledge,attitudes and practices of freshmen in Hangzhou and to provide evidence for prevention and control of AIDS in university students.
Methods:
Freshmen who enrolled in 2015 in a comprehensive university in Hangzhou were recruited by convenience sampling method and surveyed by a questionnaire about AIDS knowledge,attitudes and practices. Logistic regression model was used to analyze the influencing factors for awareness of AIDS knowledge among freshmen.
Results:
There were 1 999 respondents recruited,with a response rate of 95.19%. The awareness rates of basic and extend AIDS knowledge were 97.90% and 30.67%,respectively. The results of multivariate logistic regression analysis showed that residence(OR=1.210,95%CI:1.006-1.456),average or good family economic status(OR:1.874-3.027,95%CI:1.255-7.300),receiving AIDS/STD related education(OR=1.717,95%CI:1.407-2.097)and receiving AIDS/STD related counselling in the past year(OR=1.786,95%CI:1.033-3.088)were the promotive factors for awareness of AIDS knowledge among freshmen. About 48.50% of freshmen thought they were impossible to be infected with AIDS,and 47.10% of them thought they were less likely to be infected with AIDS. About 0.90% of freshmen had sexual experience,fifteen,two and one of them experienced their first sex with girlfriend/boyfriend,homosexual partners and casual sex partners,respectively;nine of them used condoms in their first sex. The proportions of receiving AIDS/STD related services among freshmen ranged 2.00% from 37.77%.
Conclusion
The freshmen have a poor understanding of AIDS,weak awareness of HIV infection risk,high-risk behaviors for STDS/AIDS and receive insufficient AIDS prevention and intervention measures.
10.Cell Count of Mouse Blastocyst on Pre-clinical Evaluation of Safety of Medical Devices in Assisted Reproductive Technologies.
Qianqian HAN ; Junzhao ZHAO ; Zhaopeng YANG ; Jianfeng SHI ; Ying WANG ; Huan LIAN ; Chunren WANG ; Xingliang JIN
Chinese Journal of Medical Instrumentation 2018;42(4):289-292
Various types of medical devices used in assisted reproductive technologies (ART) should be detected for their safety by strict biological assays. Mouse embryo assay(MEA)has been recognized as one of the most important and standardized methods with the threshold more than 80% of blastocyst formation rate (BR) after 96 h culture of fertilized eggs. The disadvantage using BR for embryonic quality control has been concerned as it is ubiquitously dependent of embryonic morphology and the detailed data including molecular and genetic information is obviously missing and incomplete. This leads to the urgent requirement for more sensitive and efficient assessments for the quality control of ART. This study evaluated the reliability of an immunofluorescent MEA by counting total cell and differential number of the cells in the inner cell mass (ICM) and trophectoderm (TE) in the blastocyst. This method improved the traditional MEA, provided a sensitive and powerful platform to assess embryonic developmental viability and should be suggested as a standard assay to be globally used for the quality control of medical devices and pre-clinical procedures in ART.
Animals
;
Blastocyst
;
Embryonic Development
;
Equipment Safety
;
Mice
;
Reproducibility of Results
;
Reproductive Techniques, Assisted
;
instrumentation


Result Analysis
Print
Save
E-mail