1.Program-controlled high-fi amplifier for EMG
Ming-Xin QIN ; Wei SONG ;
Chinese Medical Equipment Journal 1989;0(03):-
we have designed a program-controlled high-fi amplifier for EMG.Its gain can be controlled by computer.The program-contralled circuit is implemented with numerical control resistor.The amplifier can be used in automatically measuring EMG signals over 100?v.The circuit is characterized by easy de- sign,simple programing and convenient control.
2.Optical quality evaluation of pseudophakic eyes implanted different materials of IOL by optical quality analysis system
Yinjuan, WEI ; Hui, SONG ; Xin, TANG
Chinese Journal of Experimental Ophthalmology 2016;34(3):248-253
Background Phacoemulsification with IOL implantation can reduce the light scattering caused by cataract,but many patients with IOLs implantation complained of glare or blurred vision.IOLs from different materials will affect IOL refractive index (RI) and optical design,which affect the value of scattered light of IOLs implantation.Objective This study was to analyze the effect of IOL materials on optical quality in pseudophakic eyes with optical quality analysis system (OQAS).Methods The clinical data of 95 eyes from 65 patients with age-related cataract who received phacoemulcification with IOL implantation in Tianjin Eye Hospital from March to Octomber were retropectively analyzed.Three types of lOL,including AR40e,Acrysof SA60 AT and Rayner 620H,were implanted in 32 eyes,30 eyes and 33 eyes,respectively.The visual quality indexes were detected and evaluated using OQAS,including uncorrected distance visual acuity (UCDVA,LogMAR),objective scatter index (OSI),modulation transfer function cut off (MTF cut off),strehl ratio (SR),Profile width at 50% point scatter function (PSF),Profile width at 10% PSF and contrast visual acuity under the 100%,20%,9% contrasts.Results The UCDVA was ≥ 0.3 in the eyes of AR40e group,SA60AT group and 620H group 1 month after surgery.No significant difference was found in the best corrected distance visual acuity (BCDVA,LogMAR) among three groups (F =1.362,P =0.246).The OSI was 1.72±1.11,1.89±1.07 and 2.13±1.13 in the AR40e group,SA60AT group and 620H group,with a significant difference among the groups (F =3.638,P =0.045),and the OSI was significantly lower in the AR40e group than that in the SA60AT group or 620H group (both at P<0.05).No considerable difference in MTF cut off among the groups (F =2.401,P =0.192).The SR value was significantly elevated and the PSF at both 50% and 10% was declined in the AR40e group compared with the SA60AT group and 620H group (all at P<0.05).A significant difference was found in 9% contrast visual acuity among the three groups (F=3.866,P=0.038),and 9% contrast visual acuity was better in the AR40e group than that in the SA60At group or the 620H group (both at P< 0.05).Negative correlations were found betwee OSI and BCDVA in the AR40e group,SA60AT group and 620H group (r=-0.275,P=0.041;r=-0.287,P=0.042;r=-0.233,P=0.037).Conclusions OQAS can evaluate optical quality of cataract patients after opeartion objectively.Material and RI of IOL have a great effect on visual quality after phacoemulcification with IOL implantation,especially under the low contrast environment.The operated eyes implanted hydrophobic acrylic IOLs with a lower RI can get better optical quality in comparison with the eyes implanted hydrophilic IOLs.
3.Clinical observation on large dosage of shenfu injection in supplementary treating liver cirrhosis complicated with esophageal varix rupture bleeding.
Chinese Journal of Integrated Traditional and Western Medicine 2002;22(3):211-212
Adult
;
Drugs, Chinese Herbal
;
administration & dosage
;
therapeutic use
;
Esophageal and Gastric Varices
;
drug therapy
;
etiology
;
Female
;
Gastrointestinal Hemorrhage
;
drug therapy
;
etiology
;
Humans
;
Infusions, Intravenous
;
Liver Cirrhosis
;
complications
;
drug therapy
;
Male
;
Middle Aged
;
Phytotherapy
4.Study of the location of coronary ostial in the artic valve stenosis by the real-time three-dimensional transesophageal echocardiography
Lingqiu KONG ; Ben REN ; Yu KANG ; Xin WEI ; Haibo SONG ; Xin WEI ; Hong TANG
Chinese Journal of Ultrasonography 2012;21(10):829-832
Objective To study the the feasibility of real-time 3D transesophageal echocardiography (RT-3D TEE) to measure the distance between the coronary ostial and the junction of left ventricle and artery.Methods The RT-3D TEE image of the aortic root was collected intraoperative in 65 cases who were refered to our center for valve replacement.The reconstruction of the aortic annulus was done in the QLAB quantitative analysis software and the height parameter of the annulus could be generated.Meanwhile the coronary artery position was observed and the distance between the coronary ostial and the junction of left ventricle and artery was measured respectively.Results In the 65 cases,49 cases clearly showed bilateral coronary ostial,three cases only showed the left coronary ostial,six cases only showed the right coronary ostial,seven cases of both sides of the coronary ostial were unclear.The shows rate of right coronary ostial was 84.61% (55/65),with the left coronary ostial 81.54% (52/65).The measured value of the L-AA in systole and diastole were (15.5 ± 1.9)mm,(12.8 ± 1.5)mm,the R-AA systole and diastole measured values were (13.7 ± 1.8)mm,(12.4 ± 1.7)mm,respectively,there was significant difference between systole and diastole respectively.The aortic annulus height (H) got by 3D reconstruction of the aortic annulus was lower than ventricular-arterial junction to the coronary artery distance in both systole and diastole.Conclusions Not only can RT-3D TEE reconstruct the annulus,but also can show and measure the distance between the coronary ostial and the junction of left ventricle and artery respectively.
5.Influence of nodule enhanced viewing of dual-source CT on efficacy of detecting pulmonary nodule in low-dose CT
Liang YANG ; Wei SONG ; Xin SUI ; Zhengyu JIN ; Yun WANG
Chinese Journal of Radiology 2013;47(8):709-712
Objective To evaluate efficacy in detecting lung nodules at low-dose CT(LDCT) by nodule enhanced viewing(NEV).Methods One hundred and twenty seven patients who were referred to undergo low-dose CT (LDCT) for the evaluation of pulmonary metastasis or screening lung cancer were selected randomly.Two radiologists with at least 10 years experience read the images with normal clinical reading speed to find actionable nodules ≤ 2.0 cm in maximum diameter,and their consensus result was referred as Standard.NEV was adopted to detect the pulmonary nodules.Two residents with experience of less than three years read first detected suspicious nodules and recorded reading time,first consensus and mean time were recorded.Then,they made second decisions on the images with the help of NEV and the results and the reading time were recorded and analyzed by using wilcoxon test.The sensitivity and accuracy of NEV,residents and residents with NEV were analyzed.Results Standard,resident,NEV and resident with NEV detected 570,404,768 and 593 lung nodules ≤2.0 cm in maximum diameter,respectively.More than 60% nodules were less than 0.5 cm in maximum diameter.The performance of NEV in detecting nodules ≤2.0 cm as well as nodules < 0.5 cm in maximum diameter was significantly higher than that of the resident(Z =-6.887,P <0.01 and Z =-7.235,P <0.01),and the performance of resident with NEV indetecting nodules ≤2.0 cm as well as nodules < 0.5 cm in maximum diameter was significantly higher than that of resident without NEV (Z =-6.606,P < 0.01 and Z =-6.657,P < 0.01).The resident,NEV and the resident with NEV detected nodules < 20 mm in maximum diameter with sensitivities of 61.4%,86.3% and 95.3%,and with accuracy of 56.1%,58.1% and 87.6%,respectively.The resident achieved sensitivities of 51.4%,88.1% and 94.8%,and accuracy of 47.0%,56.9% and 87.5% for nodules <5 mm in maximum diameter,respectively.The resident,NEV and resident with NEV spent 120-444 s,85-262 s and 131-1512 s per case to read the CT scans,respectively.The reading time of resident with NEV in was significantly higher than that of resident without NEV(Z =-9.781,P < 0.01).The resident spent 23 s per NEV mark.Conclusion NEV considerable improves the resident's performance in lung nodule detection,especially in maximum diameter < 0.5 cm nodule detection.
6.Strategy of expanding marginal donor heart and elinical result
Keming YANG ; Wei WANG ; Yunhu SONG ; Xin YUAN
Chinese Journal of Organ Transplantation 2010;31(3):170-172
Objective To study the strategy of expanding standard donor heart application and to analyze the clinical effect on applying expanding standard donor heart in heart transplantation.Methods 146 patients received heart transplantation in Fuwai Hospital Bering from June 2004 to February 2009.Expanding standard donor heart was defined as prolonged ischemic time over 6 h,advanced age up to 40,and blood type ABO mismathched.Blood type examination and PRA test were done before operation.The donor heart was preserved by sequential perfusion with cold St.Thomas and HTK solution.The patients were divided into groups according to different oversize body weight,ischemic time,and donor age Results There were 11 deaths after operation.Ischernic time of donor heart was 262.1±120.8 min,and that of 21 donors was over 360 min(the longest one was 605 min).There was no significant diffeFence in recipient properties before transplantation.and also there was no significant difference in mortality,heart function,heart rejection,and main morbidity after transplantation and during follow-up.Conclusion These data support continued aggressive utilization of expanding standard donor hearts in heart transplantation.Our experience demonstrates thatproperly expanding standard cardiac allografts application has no effects on the short- and long-term clinical outcome following heart transplantation.
7.Detection and Validated Quantification of 11 Sedative-Hypnotics in Human Plasma by UPLC-MS/MS Method
Jing AN ; Zhanjun DONG ; Xin WEI ; Wanjun BAI ; Haojing SONG
Herald of Medicine 2016;35(9):938-942
Objective To develop a rapid ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) for determination of 11 sedative-hypnotics in human plasma. Methods The plasma samples were extracted with dichloromethane:n-hexane:acetoacetate (5∶4∶1). The separation was performed on a Waters ACQUITY UPLC HSS T3 column (2.1 mm×100 mm,1.8 μm) using the mobile phase composed of acetonitrile-0.1% ammonium solution at a flow rate of 0.2 mL?min-1 in gradient elution mode. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization (ESI) source in positive mode. Results Good linear relation was obtained over the investigated concentration range, with all correlation coefficients higher than 0.99. The limit of detection was 200 pg?mL-1 for dexzopiclone,and 10- 20 pg?mL-1 for other sedative-hypnotics. The intra- and inter-day RSD of 11 sedative-hypnotics were no more than 15.0%. The recoveries were in the range of 72.3%-108.0%, and the matrix effects were approximately 0.86- 1. 12. Conclusion The method is rapid, sensitive and reliable, and suitable for the simultaneous determination of 11 sedative-hypnotics in human plasma.
8.Effects of advanced glycation end products on protein and mRNA expression of macrophage inflammatory protein-1? in cultured human umbilical vein endothelial cells
Xin MENG ; Jin ZHANG ; Wei WU ; Song BAI
Chinese Journal of Pathophysiology 1986;0(04):-
AIM: To investigate the effects of advanced glycation end products (AGEs) on protein and mRNA expression of macrophage inflammatory protein-1? (MIP-1?) in cultured human umbilical vein endothelial cells(HUVECs). METHODS: HUVECs were cultured with AGEs at different concentrations for 24 h and at a concentration of 400 mg/L for different time.The levels of mRNA and protein expression of MIP-1? in cultured HUVEC were detected by in situ hybridization and Western blot, respectively. RESULTS: In situ hybridization showed that after exposure of HUVECs to AGEs at different concentrations (100 mg/L, 200 mg/L, 400 mg/L) for 24 h, the average integrated optical density values (18.76?3.17, 26.58?1.61, 34.23?2.25) of MIP-1? mRNA expression in HUVECs were higher than that in control group (13.83?1.24, P
9.Confer Effect of Air Disinfection by Using Nanometer Light Catalysis Decontamination Machine in Operating Room
Feng SONG ; Xin DONG ; Caixia YIN ; Hua WEI ; Yubin XING
Chinese Journal of Nosocomiology 2006;0(06):-
OBJECTIVE To analysis the effect of air disinfection by using nanometer light catalysis decontamination machine in operating room. METHODS By compare the effectiveness of air disinfection both by using nanometer light catalysis decontamination machine and ultraviolet rays light. RESULTS The result of tests is 0 CFU/m~2 by nanometer light catalysis decontamination machine and 33.3 CFU/m~2 by ultraviolet rays light in unmanned environment;By different groups: F=220.423,P=0.000,P
10.Segmentation of heart valves in DS CT image based on Contourlet transform
Lidan MA ; Xin YANG ; Wei SONG ; Junwei QIU ; Kun SUN
Journal of Medical Biomechanics 2009;24(6):408-413,433
Objecthe Children's heart valves by Dual-Source Compater Tomography(DS CT)images were enhanced and segmented in order to reconstruct 3D construction of heart valves and make motion analysis based on this model.Method,Adaptive seed-filling algorithm is proposed in this paper to segment interested region of heart based on DS CT images.Contoudet transform is used to enhance and segment heart valve based on the part-segmented image.Result With these methods,DS CT images were SUCCESS fully pro-cessed and segmented in Matlab 7.0 and clear images of mitral valves were got.Condusions The adaptive seed-filling algorithm proposed in this paper and Contourlet transform are very useful for segmentation in dif-ferent situation.The experimental result in this paper proides useful reference for doctors in their research on the motion of mitral valves and planning on surrgical operation of mitTal valves.