1.Program-controlled high-fi amplifier for EMG
Ming-Xin QIN ; Wei SONG ;
Chinese Medical Equipment Journal 1989;0(03):-
we have designed a program-controlled high-fi amplifier for EMG.Its gain can be controlled by computer.The program-contralled circuit is implemented with numerical control resistor.The amplifier can be used in automatically measuring EMG signals over 100?v.The circuit is characterized by easy de- sign,simple programing and convenient control.
2.Clinical observation on large dosage of shenfu injection in supplementary treating liver cirrhosis complicated with esophageal varix rupture bleeding.
Chinese Journal of Integrated Traditional and Western Medicine 2002;22(3):211-212
Adult
;
Drugs, Chinese Herbal
;
administration & dosage
;
therapeutic use
;
Esophageal and Gastric Varices
;
drug therapy
;
etiology
;
Female
;
Gastrointestinal Hemorrhage
;
drug therapy
;
etiology
;
Humans
;
Infusions, Intravenous
;
Liver Cirrhosis
;
complications
;
drug therapy
;
Male
;
Middle Aged
;
Phytotherapy
3.Optical quality evaluation of pseudophakic eyes implanted different materials of IOL by optical quality analysis system
Yinjuan, WEI ; Hui, SONG ; Xin, TANG
Chinese Journal of Experimental Ophthalmology 2016;34(3):248-253
Background Phacoemulsification with IOL implantation can reduce the light scattering caused by cataract,but many patients with IOLs implantation complained of glare or blurred vision.IOLs from different materials will affect IOL refractive index (RI) and optical design,which affect the value of scattered light of IOLs implantation.Objective This study was to analyze the effect of IOL materials on optical quality in pseudophakic eyes with optical quality analysis system (OQAS).Methods The clinical data of 95 eyes from 65 patients with age-related cataract who received phacoemulcification with IOL implantation in Tianjin Eye Hospital from March to Octomber were retropectively analyzed.Three types of lOL,including AR40e,Acrysof SA60 AT and Rayner 620H,were implanted in 32 eyes,30 eyes and 33 eyes,respectively.The visual quality indexes were detected and evaluated using OQAS,including uncorrected distance visual acuity (UCDVA,LogMAR),objective scatter index (OSI),modulation transfer function cut off (MTF cut off),strehl ratio (SR),Profile width at 50% point scatter function (PSF),Profile width at 10% PSF and contrast visual acuity under the 100%,20%,9% contrasts.Results The UCDVA was ≥ 0.3 in the eyes of AR40e group,SA60AT group and 620H group 1 month after surgery.No significant difference was found in the best corrected distance visual acuity (BCDVA,LogMAR) among three groups (F =1.362,P =0.246).The OSI was 1.72±1.11,1.89±1.07 and 2.13±1.13 in the AR40e group,SA60AT group and 620H group,with a significant difference among the groups (F =3.638,P =0.045),and the OSI was significantly lower in the AR40e group than that in the SA60AT group or 620H group (both at P<0.05).No considerable difference in MTF cut off among the groups (F =2.401,P =0.192).The SR value was significantly elevated and the PSF at both 50% and 10% was declined in the AR40e group compared with the SA60AT group and 620H group (all at P<0.05).A significant difference was found in 9% contrast visual acuity among the three groups (F=3.866,P=0.038),and 9% contrast visual acuity was better in the AR40e group than that in the SA60At group or the 620H group (both at P< 0.05).Negative correlations were found betwee OSI and BCDVA in the AR40e group,SA60AT group and 620H group (r=-0.275,P=0.041;r=-0.287,P=0.042;r=-0.233,P=0.037).Conclusions OQAS can evaluate optical quality of cataract patients after opeartion objectively.Material and RI of IOL have a great effect on visual quality after phacoemulcification with IOL implantation,especially under the low contrast environment.The operated eyes implanted hydrophobic acrylic IOLs with a lower RI can get better optical quality in comparison with the eyes implanted hydrophilic IOLs.
4.Study of the location of coronary ostial in the artic valve stenosis by the real-time three-dimensional transesophageal echocardiography
Lingqiu KONG ; Ben REN ; Yu KANG ; Xin WEI ; Haibo SONG ; Xin WEI ; Hong TANG
Chinese Journal of Ultrasonography 2012;21(10):829-832
Objective To study the the feasibility of real-time 3D transesophageal echocardiography (RT-3D TEE) to measure the distance between the coronary ostial and the junction of left ventricle and artery.Methods The RT-3D TEE image of the aortic root was collected intraoperative in 65 cases who were refered to our center for valve replacement.The reconstruction of the aortic annulus was done in the QLAB quantitative analysis software and the height parameter of the annulus could be generated.Meanwhile the coronary artery position was observed and the distance between the coronary ostial and the junction of left ventricle and artery was measured respectively.Results In the 65 cases,49 cases clearly showed bilateral coronary ostial,three cases only showed the left coronary ostial,six cases only showed the right coronary ostial,seven cases of both sides of the coronary ostial were unclear.The shows rate of right coronary ostial was 84.61% (55/65),with the left coronary ostial 81.54% (52/65).The measured value of the L-AA in systole and diastole were (15.5 ± 1.9)mm,(12.8 ± 1.5)mm,the R-AA systole and diastole measured values were (13.7 ± 1.8)mm,(12.4 ± 1.7)mm,respectively,there was significant difference between systole and diastole respectively.The aortic annulus height (H) got by 3D reconstruction of the aortic annulus was lower than ventricular-arterial junction to the coronary artery distance in both systole and diastole.Conclusions Not only can RT-3D TEE reconstruct the annulus,but also can show and measure the distance between the coronary ostial and the junction of left ventricle and artery respectively.
5.The cleaning of plaque biofilm on the surface of macromolecule ocular prosthesis material
Suping GUO ; Yan SONG ; Fantao WANG ; Xin XU ; Wei JIA
Chinese Journal of Tissue Engineering Research 2015;(43):6993-6997
BACKGROUND:The micro-ecological environment has been broken when the ocular prosthesis was inset into the conjunctival sac. The recede of self cleaning function is more conducive to the microbial growth and colonization. The cleaning of plaque biofilm on ocular prosthesis surface affects the patient's wearing comfort and quality of life. It is necessary to seek an effective cleaning method. OBJECTIVE:To compare the clearance effect of five cleaning methods on the palque biofilm on ocular prosthesis surface. METHODS: The conjunctival secretions from 84 patients who were subjected to ocular prosthesis repair were taken for bacterial culture and identification. Fifty pieces of self-curing resin and thermosetting resin artificial eyes were produced. The artificial eyes in each group were randomly divided into five groups, and were cleaned respectively with clear water, volume fraction of 75% ethanol, Boston SIMPLUS, polident and toothpaste. After the completion of the cleaning, the test piece was conducted residual biofilm culture. The clearance effects of different processing modes were evaluated using colony counting method. RESULTS AND CONCLUSION: Eighty-four specimens were submitted for inspection, of which 49 were positive. The Staphylococcusaureus separation rate was 14.29%.Staphylococcus epidermidis separation rate accounted for 13.10%. Maxwel Corynebacterium separation rate accounted for 7.14%. When water, Boston SIMPLUS and toothpaste were used for cleaning, theStaphylococcus aureus colony number in the self-curing resin group was higher than that in the thermosetting resin group (P< 0.05); when ethanol and polident were used for cleaning, there was no difference in the Staphylococcus aureus colony number between these two groups. In self-curing resin, the colony count in the clear water treatment group was higher than that in the other treatment groups (P < 0.05). The colony count in the ethanol treatment group was lower than that in the Boston SIMPLUS group (P < 0.05). There was no significant difference in the colony count between other groups. In thermosetting resin, the colony count in the clear water treatment group was higher than that in the other treatment groups (P < 0.05). There was no significant difference in the colony count between other groups. These results demonstrate that ethanol, Boston SIMPLUS, polident and toothpaste have better cleaning effects onStaphylococcus aureusbiofilms on the surface of two kinds of ocular prostheses than the clear water rinse. Overal, it is encouraged to clean the artificial eyes using polident and Boston SIMPLUS, in order to avoid the occurrence of microbial infection in the conjunctival sac after wearing ocular prosthesis.
6.Effects of advanced glycation end products on protein and mRNA expression of macrophage inflammatory protein-1? in cultured human umbilical vein endothelial cells
Xin MENG ; Jin ZHANG ; Wei WU ; Song BAI
Chinese Journal of Pathophysiology 1986;0(04):-
AIM: To investigate the effects of advanced glycation end products (AGEs) on protein and mRNA expression of macrophage inflammatory protein-1? (MIP-1?) in cultured human umbilical vein endothelial cells(HUVECs). METHODS: HUVECs were cultured with AGEs at different concentrations for 24 h and at a concentration of 400 mg/L for different time.The levels of mRNA and protein expression of MIP-1? in cultured HUVEC were detected by in situ hybridization and Western blot, respectively. RESULTS: In situ hybridization showed that after exposure of HUVECs to AGEs at different concentrations (100 mg/L, 200 mg/L, 400 mg/L) for 24 h, the average integrated optical density values (18.76?3.17, 26.58?1.61, 34.23?2.25) of MIP-1? mRNA expression in HUVECs were higher than that in control group (13.83?1.24, P
7.Strategy of expanding marginal donor heart and elinical result
Keming YANG ; Wei WANG ; Yunhu SONG ; Xin YUAN
Chinese Journal of Organ Transplantation 2010;31(3):170-172
Objective To study the strategy of expanding standard donor heart application and to analyze the clinical effect on applying expanding standard donor heart in heart transplantation.Methods 146 patients received heart transplantation in Fuwai Hospital Bering from June 2004 to February 2009.Expanding standard donor heart was defined as prolonged ischemic time over 6 h,advanced age up to 40,and blood type ABO mismathched.Blood type examination and PRA test were done before operation.The donor heart was preserved by sequential perfusion with cold St.Thomas and HTK solution.The patients were divided into groups according to different oversize body weight,ischemic time,and donor age Results There were 11 deaths after operation.Ischernic time of donor heart was 262.1±120.8 min,and that of 21 donors was over 360 min(the longest one was 605 min).There was no significant diffeFence in recipient properties before transplantation.and also there was no significant difference in mortality,heart function,heart rejection,and main morbidity after transplantation and during follow-up.Conclusion These data support continued aggressive utilization of expanding standard donor hearts in heart transplantation.Our experience demonstrates thatproperly expanding standard cardiac allografts application has no effects on the short- and long-term clinical outcome following heart transplantation.
8.Influence of nodule enhanced viewing of dual-source CT on efficacy of detecting pulmonary nodule in low-dose CT
Liang YANG ; Wei SONG ; Xin SUI ; Zhengyu JIN ; Yun WANG
Chinese Journal of Radiology 2013;47(8):709-712
Objective To evaluate efficacy in detecting lung nodules at low-dose CT(LDCT) by nodule enhanced viewing(NEV).Methods One hundred and twenty seven patients who were referred to undergo low-dose CT (LDCT) for the evaluation of pulmonary metastasis or screening lung cancer were selected randomly.Two radiologists with at least 10 years experience read the images with normal clinical reading speed to find actionable nodules ≤ 2.0 cm in maximum diameter,and their consensus result was referred as Standard.NEV was adopted to detect the pulmonary nodules.Two residents with experience of less than three years read first detected suspicious nodules and recorded reading time,first consensus and mean time were recorded.Then,they made second decisions on the images with the help of NEV and the results and the reading time were recorded and analyzed by using wilcoxon test.The sensitivity and accuracy of NEV,residents and residents with NEV were analyzed.Results Standard,resident,NEV and resident with NEV detected 570,404,768 and 593 lung nodules ≤2.0 cm in maximum diameter,respectively.More than 60% nodules were less than 0.5 cm in maximum diameter.The performance of NEV in detecting nodules ≤2.0 cm as well as nodules < 0.5 cm in maximum diameter was significantly higher than that of the resident(Z =-6.887,P <0.01 and Z =-7.235,P <0.01),and the performance of resident with NEV indetecting nodules ≤2.0 cm as well as nodules < 0.5 cm in maximum diameter was significantly higher than that of resident without NEV (Z =-6.606,P < 0.01 and Z =-6.657,P < 0.01).The resident,NEV and the resident with NEV detected nodules < 20 mm in maximum diameter with sensitivities of 61.4%,86.3% and 95.3%,and with accuracy of 56.1%,58.1% and 87.6%,respectively.The resident achieved sensitivities of 51.4%,88.1% and 94.8%,and accuracy of 47.0%,56.9% and 87.5% for nodules <5 mm in maximum diameter,respectively.The resident,NEV and resident with NEV spent 120-444 s,85-262 s and 131-1512 s per case to read the CT scans,respectively.The reading time of resident with NEV in was significantly higher than that of resident without NEV(Z =-9.781,P < 0.01).The resident spent 23 s per NEV mark.Conclusion NEV considerable improves the resident's performance in lung nodule detection,especially in maximum diameter < 0.5 cm nodule detection.
9.Factors of Affecting Mcrobial Fermentative Hydrogen Production
Ben-Yi XIAO ; Yuan-Song WEI ; Jun-Xin LIU ;
Microbiology 1992;0(03):-
As a clean, efficient, and renewable energy, hydrogen is regarded as a promising alternative. Because of using biomass as substrate, microbial fermentative hydrogen production can meet the need of sustainable development. The factors affecting the process of microbial fermentative hydrogen production, are analyzed in this paper on the basis of microorganisms, substrates, products and operative parameters. The parameters related to hydrogen production from organic wastes, are also mentioned.
10.The effects of plasmin Kringle domains deficiency mutant on the interface of vitreous and retina in rabbit eyes
Wu, CHEN ; Xin, HUANG ; Wei, MO ; Wenji, WANG ; Houyan, SONG
Chinese Ophthalmic Research 2010;28(3):231-235
Background The vitreoretinal traction plays a critical role in the formation of macular hole and cystoid macular edema.Enzymatic vitreolysis has potential in relieving vitreoretinal traction as a simple and less invasive method in comparison with pars plane vitrectomy.ObjectiveThis study is to investigate the effects of plasmin mutant with kringle domains deficiency(Plm△K)on vitreoretinal interface in new Zealand white rabbits.Methods Plm△K was prepared through activating plasminogen mutant with Kringle domains deficiency (Plg△K) by tissue plasminogen activator (tPA).100μL of Plm△K at the dose of 0.5,1.0 and 1.5μmol/min was injected respectively into the vitreous of 48 New Zealand white rabbits and 16 eyes for each dose.B-scan and optical coherence tomography (OCT) were performed to detect the structure variety at the vitreoretinal interface in 1 day and 7 days after injection.The gross anatomy analysis with triamcinolone acetonide fine particle suspension,as well as histopathological examinations by scanning electron microscopy,was performed in the different time points mentioned above.Results Two peptide chains were determined with the relative molecular weight about 26000 and 5000 by the gel imaging analysis of reduced SDS-PAGE.Separation of the posterior vitreous cortex from retina was found after intravitreous injection under the B-scan and OCT.The ultrastructure change of vitreoretinal interface as well as the examination of fine particle suspension by triamcinolone acetonide demonstrated the same outcome.The degree of remnants of vitreous cortex showed the negative correlation with the dosage of Plm△K (r=-0.9516,P=0.048).No significant correlation was found between the degree of remnants of vitreous cortex and the action time(r=-0.720,P=0.470).There was no obvious morphological difference in outer layer of retina between control eyes and Plm△K-treated eyes.No drug-related adverse event was found after intravitreous injection of Plm△K.Conclusion Intravitreous injection of Plm△K alone can induce complete separation of vitreous from retina.This procedure is safe and effective.