2.Study on the transmission characteristics of genital Candida albicans infection by a rapid mi-crosatellite genotyping
Weimin SHI ; Xingyu MEI ; Keke HUO ; Liangliang SHEN ; Xin HUANG
Chinese Journal of Dermatology 2003;0(12):-
Objectives In order to develop a rapid microsatellite genotyping assay for inter-strain differentiation of Candida albicans isolates and understand the transmission characteristics of the infections. Methods DNA was extracted from C. albicans isolates from genitals, anal canals and oral cavities of 39 women and 27 men with genital candidiasis. The microsatellite sequences in stabel genes(CDC3, EF3 and HIS3) were amplified by a fluorescence labeled PCR. Fluorescent signals were read with an automatic se- quencer, and the data were collected with GeneScan software followed by genotyping with Genotyper soft- ware to analyze polymorphic microsatellite loci. Results Combined analysis of the 3 microsatellite markers showed 18 gene allele associations in C. albicans from genital sites of all men and women, including 10 in women, 11 in men and 3 in both. The allele associations of dominant pathogenetic strains for both sexes were 116:124, 122:131,160:200, which covered 50% of pathogenetic infection. Three common allele associations for both sexes covered 71% of all infections. Genitals and anal canals shared strains of same allele associations in 80% of women and in only 3.8% of men. The strains of same allele associations were identified in both genitals and mouth in 2.7% of women but in none of men. In their genital sites 71% of couples shared the same allele strains, of which 80% were the dominant pathogenetic strains identified in both sexes. Conclusions The improved microsatellite genotyping assay is useful for rapid differentiation, identification of infective source, and contact tracing of C. albicans infection. There are pathogenetic C. albi- cans strains with predominant allele associations in genital infections.
4.Mining rules on determination of four properties based on traditional Chinese medicine functional combination.
Xue-Mei YANG ; Duan-Yi LIN ; Xin-Mei LAI ; Mei-Mei CHEN ; Lu-Qi HUANG
China Journal of Chinese Materia Medica 2013;38(10):1624-1626
OBJECTIVEIt laid the foundation of the large sample data mining for a comprehensive summary concerning four properties theory of traditional Chinese medicine (TCM), and also provided theory clues on determination of four properties for the new resource development of TCM and the clinical use of Chinese medicine.
METHODFour properties data of 8 980 Chinese medicines from "Chinese herbal medicine (CHM)" and associated function index data were chose as data sets. Then, the IBM SPSS Clementine 14.1 data mining platform and Apriori model were adopted to mining classification-association rules, setting the minimum support threshold of rule antecedent and the minimum confidence threshold as 0.5% and 60%.
RESULT11 classification-association rules involved in warm, cold and mild natures were found.
CONCLUSIONIt was discovered that the TCM with functions of "dispelling wind-cold, warming the middle, stopping pain and expelling wind-removing dampness, tonifying kidney yang, unblocking meridians and expelling wind-removing dampness, dispelling cold to stop pain, strengthening sinews-bones and expelling wind-removing dampness" was likely warm-natured, with functions of "tonifying the lung" was likely mild-natured, and with functions of " clearing heat and drying dampness, clearing heat and purging fire, eliminating restlessness" was likely cold-natured.
Drugs, Chinese Herbal ; chemistry ; therapeutic use ; Humans ; Medicine, Chinese Traditional ; Phytotherapy
5.Four properties law of nature data of Chinese materia medica in "Chinese herbal medicine (CHM)".
Xue-Mei YANG ; Duan-Yi LIN ; Xin-Mei LAI ; Mei-Mei CHEN ; Lu-Qi HUANG
China Journal of Chinese Materia Medica 2013;38(9):1438-1441
OBJECTIVEIn order to provide theoretical clues and data support for the use of Chinese medicine clinical drug, experimental study of Chinese materia medica and development of new resources of Chinese materia medica, the four properties as the core, the relationships of property, flavor, channel tropism and toxicity in nature data of Chinese materia medica were analyzed.
METHODThe spearman rank correlation method was employed to analyze 8 356 Chinese drugs with characteristic of four properties from " Chinese Herbal Medicine" based on data level coding.
RESULTIt was discovered that four properties showed significant positive correlations with tastes of "pungent and sweet" , channels of "spleen" , "stomach" , "kidney" and "toxicity" , but also showed significant negative correlations with tastes of "bitter" and "light" and six channels such as "large intestine" , "heart", "bladder" , "gallbladder" , "small intestine" and "lung" (in descending order of correlation ) (P <0. 01).
CONCLUSIONIt was indicated that the more hot the Chinese medicine nature, the more possible it contained "toxicity" , tastes of "pungent" and "sweet" , and the more possible it was belong to channels of "spleen" , "stomach" and "kidney". As well, the more cold the Chinese medicine nature, the more possible it contained tastes of "bitter" and "light", and the more possible it was belong to six channels such as "large intestine", etc.
Herbal Medicine ; methods ; Materia Medica ; standards ; Medicine, Chinese Traditional ; methods ; standards
6.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
7.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
8.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
9.A STUDY OF THE NUTRITIONAL STATUS AND ADEQUATE DIETARY NUTRIENTS INTAKES IN GRAVIDAS
Wenzhen PANG ; Siqi HUANG ; Lihua SHEN ; Limin ZHAO ; Mei LU ; Zongjian ZHU ; Qun WANG ; Yuying XIN ;
Acta Nutrimenta Sinica 1956;0(03):-
The nutritional status, serum protein, albumin, calcium, zinc, iron, SF, FEP, vitamin A, activity of RBC transketolase, and blood glutathione redu-ctase of 349 normal primigravidas, 30 healthy non-pregnant women and 42 toxemic gravidas were estimated longitudinally from the 1st trimester to delivery. It was noted that serum protein, albumin, Ca, Zn, and Fe decreased markedly in the course of pregnancy. The content of serum vitamin A showed no variation or decrease in the 3rd trimester in 1/3 of the pregnant women observed. Insufficiency of thiamine and riboflavin were noted in 16.7% and 47% of the normal pregnant women respectively. The adequate nutrients intakes in pregnancy were considered to be: Energy, +200 kcal/d; Protein, + 15g/d in the 2nd trimester and +25g/d in the 3rd trimester; Calcium 1000 mg/d in the 2nd trimester and 1500mg/d in the 3rd trimester; Zinc, 20mg/d; Iron 26 or 30 mg/d by supplementation if possible; vitaminA 1000 ?gRE/d; both thiamine and riboflavin 1.8 mg/d.
10.Prenatal diagnosis and treatment of fetal choroid plexus cysts
Mei-Ying LIANG ; Hong-Bin WANG ; Xin HUANG ; Yan-Qiu WEI ;
Chinese Journal of Obstetrics and Gynecology 2000;0(09):-
Objective To discuss the clinical management and significance of the prenatal diagnosis of Fetal Choroid Plexus Cysts(CPC).Methods From May 2004 to March 2007,55 cases of fetal CPC diagnosed by B-ultrasound during second trimester were prospectively studied.Each case was studied regarding fetal chromosome karyotype,disappearance weeks of the cyst,the clinical outcome and follow-up results respectively.Result The cases were diagnosed during 16-25 gestational weeks.The diameters of the cysts varied from 0.2 cm to 2.4 cm.There were 25 cases of bilateral cysts and 30 cases of unilateral or 50 cases of isolated CPC and 5 cases of complicated CPC.The cysts of all cases who continued pregnancy disappeared before 28 weeks.Fetal chromosome karyotypes were obtained in 50 cases.Among them,two cases were 18-trisomy,and one case was 21-trisomy.Five cases were terminated pregnancy because of abnormal chromosome karyotype or malformation during second trimester.One neonate was diagnosed as ventricular septal defect among 50 cases of follow up.Among these six cases,three were from advanced-age pregnant women,five cases were with abnormal fetal structure and five cases were with the diameter of bilateral or unilateral cysts more than 1.0 cm.Conclusion(1)Fetal CPC can be diagnosed during second trimester,and the majority disappear before 28 gestational weeks.(2)High risk factors for fetal abnormal chromosome karyotype may be:advanced-age pregnant women,abnormal structure of fetus,and the diameter of bilateral or unilateral cyst more than 1.0 cm.It is suggested that fetal CPC with the high risks should receive fetal chromosome karyotype test during pregnancy.