1. Applications of the Fe3O4 nanocomposite modified by Humic Acid in determination of S-phenylmercapturic acid in urine by dispersive solid-phase extraction and HPLC
Haipeng YE ; Yanpeng SHI ; Ji SHAO ; Siwei TAN ; Xiaoyue SHAN ; Lei ZHANG ; Chengjian CAO
Chinese Journal of Industrial Hygiene and Occupational Diseases 2018;36(6):463-465
Objective:
To establish a method for determination the S
2.Left Ventricular Remodeling in Patients with Primary Aldosteronism: A Prospective Cardiac Magnetic Resonance Imaging Study
Tao WU ; Yan REN ; Wei WANG ; Wei CHENG ; Fangli ZHOU ; Shuai HE ; Xiumin LIU ; Lei LI ; Lu TANG ; Qiao DENG ; Xiaoyue ZHOU ; Yucheng CHEN ; Jiayu SUN
Korean Journal of Radiology 2021;22(10):1619-1627
Objective:
This study used cardiac magnetic resonance imaging (MRI) to compare the characteristics of left ventricular remodeling in patients with primary aldosteronism (PA) with those of patients with essential hypertension (EH) and healthy controls (HCs).
Materials and Methods:
This prospective study enrolled 35 patients with PA, in addition to 35 age- and sex-matched patients with EH, and 35 age- and sex-matched HCs, all of whom underwent comprehensive clinical and cardiac MRI examinations. The analysis of variance was used to detect the differences in the characteristics of left ventricular remodeling among the three groups. Univariable and multivariable linear regression analyses were used to determine the relationships between left ventricular remodeling and the physiological variables.
Results:
The left ventricular end-diastolic volume index (EDVi) (mean ± standard deviation [SD]: 85.1 ± 13.0 mL/m2 for PA, 75.9 ± 14.3 mL/m2 for EH, and 77.3 ± 12.8 mL/m2 for HC; p = 0.010), left ventricular end-systolic volume index (ESVi) (mean ± SD: 35.2 ± 9.8 mL/m2 for PA, 30.7 ± 8.1 mL/m2 for EH, and 29.5 ± 7.0 mL/m2 for HC; p = 0.013), left ventricular mass index (mean ± SD: 65.8 ± 16.5 g/m2 for PA, 56.9 ± 12.1 g/m2 for EH, and 44.1 ± 8.9 g/m2 for HC; p < 0.001), and native T1 (mean ± SD: 1224 ± 39 ms for PA, 1201 ± 47 ms for EH, and 1200 ± 44 ms for HC; p = 0.041) values were higher in the PA group compared to the EH and HC groups. Multivariable linear regression demonstrated that log (plasma aldosteroneto-renin ratio) was independently correlated with EDVi and ESVi. Plasma aldosterone was independently correlated with native T1.
Conclusion
Patients with PA showed a greater degree of ventricular hypertrophy and enlargement, as well as myocardial fibrosis, compared to those with EH. Cardiac MRI T1 mapping can detect left ventricular myocardial fibrosis in patients with PA.
3.Left Ventricular Remodeling in Patients with Primary Aldosteronism: A Prospective Cardiac Magnetic Resonance Imaging Study
Tao WU ; Yan REN ; Wei WANG ; Wei CHENG ; Fangli ZHOU ; Shuai HE ; Xiumin LIU ; Lei LI ; Lu TANG ; Qiao DENG ; Xiaoyue ZHOU ; Yucheng CHEN ; Jiayu SUN
Korean Journal of Radiology 2021;22(10):1619-1627
Objective:
This study used cardiac magnetic resonance imaging (MRI) to compare the characteristics of left ventricular remodeling in patients with primary aldosteronism (PA) with those of patients with essential hypertension (EH) and healthy controls (HCs).
Materials and Methods:
This prospective study enrolled 35 patients with PA, in addition to 35 age- and sex-matched patients with EH, and 35 age- and sex-matched HCs, all of whom underwent comprehensive clinical and cardiac MRI examinations. The analysis of variance was used to detect the differences in the characteristics of left ventricular remodeling among the three groups. Univariable and multivariable linear regression analyses were used to determine the relationships between left ventricular remodeling and the physiological variables.
Results:
The left ventricular end-diastolic volume index (EDVi) (mean ± standard deviation [SD]: 85.1 ± 13.0 mL/m2 for PA, 75.9 ± 14.3 mL/m2 for EH, and 77.3 ± 12.8 mL/m2 for HC; p = 0.010), left ventricular end-systolic volume index (ESVi) (mean ± SD: 35.2 ± 9.8 mL/m2 for PA, 30.7 ± 8.1 mL/m2 for EH, and 29.5 ± 7.0 mL/m2 for HC; p = 0.013), left ventricular mass index (mean ± SD: 65.8 ± 16.5 g/m2 for PA, 56.9 ± 12.1 g/m2 for EH, and 44.1 ± 8.9 g/m2 for HC; p < 0.001), and native T1 (mean ± SD: 1224 ± 39 ms for PA, 1201 ± 47 ms for EH, and 1200 ± 44 ms for HC; p = 0.041) values were higher in the PA group compared to the EH and HC groups. Multivariable linear regression demonstrated that log (plasma aldosteroneto-renin ratio) was independently correlated with EDVi and ESVi. Plasma aldosterone was independently correlated with native T1.
Conclusion
Patients with PA showed a greater degree of ventricular hypertrophy and enlargement, as well as myocardial fibrosis, compared to those with EH. Cardiac MRI T1 mapping can detect left ventricular myocardial fibrosis in patients with PA.
4.Qualitative study on the real experience of rotation of nurses in the neurointensive care unit
Junhong REN ; Li ZENG ; Xiaoyue LI ; Jiali CHEN ; Qi LIN ; Manshi CHEN ; Chunjing XU ; Lei YU
Chinese Journal of Practical Nursing 2020;36(30):2371-2375
Objective:To further understand the real experience of the nurse in the rotation of NICU in neurosurgery.Methods:Qualitative research method was used to analyze the reflective diary of 26 nurses and the semi-structured interview data of 8 nurses.Results:Three primary themes and 11 secondary themes were extracted from the real experience of rotation of nurses in the neurointensive care unit: department integration and mental process, role competency and influencing factors, career expectations and coping strategies.Conclusions:At present, the integration process of the nurses in the neurointensive care unit is slow. Influenced by many factors, it is difficult to change their roles. It is the direction that nursing managers should pay attention to establish a diversified discipline training system and create a better organizational commitment
5.The method of determination for 2, 3-Butanedione in the air of workplace by high performance liquid chromatography with derivatization
Haipeng YE ; Hong FU ; Ji SHAO ; Xiaoyue SHAN ; Ling ZHANG ; Lei ZHANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(2):129-132
Objective:To establish a method for the determination of 2, 3-Butanedione (BUT) in the air of workplace, which including the process of collection by absorption in phosphoric acid aqueous solution and the process of analysis and detection by high performance liquid chromatography with derivatization.Methods:In October 2022, a porous glass plate absorption tube containing 10 ml of 0.01% phosphoric acid solution was used to collect BUT in the air of the workplace at a flow rate of 0.2 L/min. The absorption solution was derived by 2, 4-dinitrophenylhydrazine for 75 min and separated on a SB-C18 column (250 mm×4.6 mm, 5 μm) . At the column temperature of 30 ℃, the mixture of acetonitrile-water ( V∶ V, 1∶1) was eluted at the flow rate of 1.0 ml/min. It was detected by UV detector (λ=365 nm) , qualitatived by retention time and quantitatived by external standard. Results:It showed that BUT in phosphoric acid aqueous solution could be stored for at least 7 d at 4 ℃. There was a linear relationship within the determination range of 0.05-6.00 μg/ml, the linear regression equation was y=89.610 x+0.133, r=0.9999. The sampling absorption efficiencies were 98.33%-100.00%, the detection limit of the method was 0.005 μg/ml, the minimum detection concentration was 0.016 mg/m 3 (based on V0=3.0 L) . The recovery rates were 95.96%-102.44%, the intra batch precision were 4.36%-7.78%, and the inter batch precision were 4.96%-6.06%. Conclusion:The method has the advantages of simple operation, high sensitivity and good accuracy. It can prevent the loss and degradation of BUT. It can be used for the determination of BUT in the air of workplace.
6.Implications of Sarcopenia and Glucometabolism Parameters of Muscle Derived From Baseline and End-of-Treatment 18 F-FDG PET/CT in Diffuse Large B-Cell Lymphoma
Xiaoyue TAN ; Xiaolin SUN ; Yang CHEN ; Fanghu WANG ; Yuxiang SHANG ; Qing ZHANG ; Hui YUAN ; Lei JIANG
Korean Journal of Radiology 2024;25(3):277-288
Objective:
We previously found that the incidence of sarcopenia increased with declining glucose metabolism of muscle in patients with treatment-naïve diffuse large B-cell lymphoma (DLBCL). This study aimed to investigate the relationship between sarcopenia and muscle glucometabolism using 18 F-FDG PET/CT at baseline and end-of-treatment, analyze the changes in these parameters through treatment, and assess their prognostic values.
Materials and Methods:
The records of 103 patients with DLBCL (median 54 years [range, 21–76]; male:female, 50:53) were retrospectively reviewed. Skeletal muscle area at the third lumbar vertebral (L3) level was measured, and skeletal muscle index (SMI) was calculated to determine sarcopenia, defined as SMI < 44.77 cm 2 /m 2 and < 32.50 cm 2 /m 2 for male and female, respectively. Glucometabolic parameters of the psoas major muscle, including maximum standardized uptake value (SUVmax) and mean standardized uptake value (SUVmean), were measured at L3 as well. Their changes across treatment were also calculated as ΔSMI, ΔSUVmax, and ΔSUVmean; Δbody mass index was also calculated. Associations between SMI and the metabolic parameters were analyzed, and their associations with progression-free survival (PFS) and overall survival (OS) were identified.
Results:
The incidence of sarcopenia was 29.1% and 36.9% before and after treatment, respectively. SMI (P = 0.004) was lower, and sarcopenia was more frequent (P = 0.011) at end-of-treatment than at baseline. The SUVmax and SUVmean of muscle were lower (P < 0.001) in sarcopenia than in non-sarcopenia at both baseline and end-of-treatment. ΔSMI was positively correlated with ΔSUVmax of muscle (P = 0.022). Multivariable Cox regression analysis showed that sarcopenia at end-of-treatment was independently negatively associated with PFS (adjusted hazard ratio [95% confidence interval], 2.469 [1.022–5.965]), while sarcopenia at baseline was independently negatively associated with OS (5.051 [1.453–17.562]).
Conclusion
Sarcopenic patients had lower muscle glucometabolism, and the muscular and metabolic changes across treatment were positively correlated. Sarcopenia at baseline and end-of-treatment was negatively associated with the prognosis of DLBCL.
7.The method of determination for 2, 3-Butanedione in the air of workplace by high performance liquid chromatography with derivatization
Haipeng YE ; Hong FU ; Ji SHAO ; Xiaoyue SHAN ; Ling ZHANG ; Lei ZHANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(2):129-132
Objective:To establish a method for the determination of 2, 3-Butanedione (BUT) in the air of workplace, which including the process of collection by absorption in phosphoric acid aqueous solution and the process of analysis and detection by high performance liquid chromatography with derivatization.Methods:In October 2022, a porous glass plate absorption tube containing 10 ml of 0.01% phosphoric acid solution was used to collect BUT in the air of the workplace at a flow rate of 0.2 L/min. The absorption solution was derived by 2, 4-dinitrophenylhydrazine for 75 min and separated on a SB-C18 column (250 mm×4.6 mm, 5 μm) . At the column temperature of 30 ℃, the mixture of acetonitrile-water ( V∶ V, 1∶1) was eluted at the flow rate of 1.0 ml/min. It was detected by UV detector (λ=365 nm) , qualitatived by retention time and quantitatived by external standard. Results:It showed that BUT in phosphoric acid aqueous solution could be stored for at least 7 d at 4 ℃. There was a linear relationship within the determination range of 0.05-6.00 μg/ml, the linear regression equation was y=89.610 x+0.133, r=0.9999. The sampling absorption efficiencies were 98.33%-100.00%, the detection limit of the method was 0.005 μg/ml, the minimum detection concentration was 0.016 mg/m 3 (based on V0=3.0 L) . The recovery rates were 95.96%-102.44%, the intra batch precision were 4.36%-7.78%, and the inter batch precision were 4.96%-6.06%. Conclusion:The method has the advantages of simple operation, high sensitivity and good accuracy. It can prevent the loss and degradation of BUT. It can be used for the determination of BUT in the air of workplace.
8.Effects of Porphyromonas gingivalis infection with different fimA genotypes on the secretion of IL-1β, IL-6, and TNF-α by human umbilical vein endothelial cells
CAI Shuyu ; LIN Xiaoyue ; LEI Jin ; GE Song
Journal of Prevention and Treatment for Stomatological Diseases 2019;27(6):364-369
Objective:
To study the effects of Porphyromonas gingivalis (P. g) infection with I, II and IV fimA genotypes on the expression of IL-1beta, IL-6 and TNF-alpha in human umbilical vein endothelial cells (HUVECs).
Methods :
HUVECs infected with different fimA genotypes were divided into the fimA type I stimulation group, fimA type II stimulation group, fimA type IV stimulation group. In addition, a positive control group (E. coli LPS stimulation) and negative control group (cell culture medium only) were included. Cell proliferation was detected by MTT assay, and cell apoptosis was detected by flow cytometry. IL-1β, IL-6, TNF-α levels in the supernatant of HUVECs after P. g stimulation were assessed by ELISA at 2 h, 6 h and 24 h.
Results :
HUVECs were infected by P. g with fimA type I,fimA type II and LPS for 24 h. Cell proliferation was inhibited compared with the negative control group (P < 0.05), but there was no significant difference in the apoptosis rate between P. g infection and the negative control group. IL-1β levels in cell culture supernatants were higher at 2th than 6 and 24 h after stimulation of HUVECs with different fimA genotypes, while the IL-6 levels were higher at 24 h than the other time, while the TNF-α levels were no significant difference at every time. After fimA type II and IV P. g infection, IL-1β, IL-6, and TNF-α levels were increased compared with fimA type I P. g (P < 0.05).
Conclusion
Different P. g fimA genotypes have different effects on stimulating HUVECs to induce dysfunction. Here, fimA type II and IV P. g exhibit a strong ability to upregulate the secretion of IL-1β, IL-6 and TNF-alpha.
9.Modification of polyetheretherketone (PEEK) physical features to improve osteointegration.
Dan YU ; Xiaoyue LEI ; Huiyong ZHU
Journal of Zhejiang University. Science. B 2022;23(3):189-203
Polyetheretherketone (PEEK) has been widely applied in orthopedics because of its excellent mechanical properties, radiolucency, and biocompatibility. However, the bioinertness and poor osteointegration of PEEK have greatly limited its further application. Growing evidence proves that physical factors of implants, including their architecture, surface morphology, stiffness, and mechanical stimulation, matter as much as the composition of their surface chemistry. This review focuses on the multiple strategies for the physical modification of PEEK implants through adjusting their architecture, surface morphology, and stiffness. Many research findings show that transforming the architecture and incorporating reinforcing fillers into PEEK can affect both its mechanical strength and cellular responses. Modified PEEK surfaces at the macro scale and micro/nano scale have positive effects on cell-substrate interactions. More investigations are necessary to reach consensus on the optimal design of PEEK implants and to explore the efficiency of various functional implant surfaces. Soft-tissue integration has been ignored, though evidence shows that physical modifications also improve the adhesion of soft tissue. In the future, ideal PEEK implants should have a desirable topological structure with better surface hydrophilicity and optimum surface chemistry.
Benzophenones
;
Ketones/chemistry*
;
Polyethylene Glycols/chemistry*
;
Polymers/chemistry*
;
Surface Properties
10.Determination of diacetyl in workplace air by high performance liquid chromatography using 4-nitro-o-phenylenediamine as precolumn derivatization
Haipeng YE ; Ji SHAO ; Siwei TAN ; Xiaoyue SHAN ; Ling ZHANG ; Hong FU ; Lei ZHANG
Journal of Environmental and Occupational Medicine 2023;40(9):1079-1084
Background Diacetyl (DC) is widely used in the food flavoring industry and excessive occupational exposure to DC can cause serious respiratory diseases. However, there is no corresponding national standard method for the determination of DC in the air of workplace. Objective To establish a method for the determination of DC in workplace air by high performance liquid chromatography using 4-nitro-o-phenylenediamine (NPDA) as precolumn derivatization. Methods DC in the air of workplace was collected by solution absorption method. This experiment used NPDA as the derivatization reagent. By adjusting acidity of solution and optimizing concentration ration of DC/NPDA, derivatization temperature, and time, a method for the determination of DC in workplace air was proposed, and its performance indexes such as linearity, detection limit, and lower limit of quantification were obtained. Sampling efficiency was evaluated by relative comparison method, and sample stability was evaluated by sample preservation test. Accuracy and precision of the method were evaluated by standard addition recovery test with blank samples, and an interference test was carried out by adding standard samples. The established method was applied to actual samples to evaluate its adaptability. Results A combination of 60 °C for 2 h was selected for derivatization because a higher derivatization reaction temperature and a longer reaction time associated with a higher derivatization efficiency. The solution was separated by SB-C18 column (250 mm×4.6 mm, 5 μm) at 30 ℃, using a mixture of methanol and water (v/v, 65%/35%) as mobile phase with an elution flow rate of 1.0 mL·min−1, and was detected with a variable wavelength detector (λmax=257 nm) by qualitative analysis based on retention time and quantitative analysis based on external standard method. In terms of the proposed method, the linear range of detection was from 5 μg·L−1 to 2000 μg·L−1, with a correlation coefficient of 0.9999, and a detection limit of 1.3 μg·L−1, the quantitative detection of the lower limit was 4.3 μg·L−1, with a sampling volume V0 of 3.0 L, the minimum detection concentration was 4.3 μg·m−3, and the minimum quantitative concentration was 14.3 μg·m−3. The recovery rate was 99.1%-100.8%, the intra-batch precision was 0.5%-3.0%, and the inter-batch precision was 1.2%-2.0%. The average sampling efficiency of this method was 94.5%, and the sample could be stored at 4 °C for at least 14 d. The coexisting components in the air of the workplace did not interfere with the determination of DC. The DC content in the air of a flavor workplace was 5.86-8.85 mg·m−3. Conclusion A determination method for DC in workplace air by high performance liquid chromatography using NPDA as precolumn derivatization after being collected by 1.0% phosphoric acid absorbent is proposed and has the advantages of simple operation, high sensitivity, and good accuracy. With no DC loss and degradation, the method may satisfy the request for DC determination in the air of workplace.