1.Application of computer-aided techniques in treatment of proximal humeral fractures
Chinese Journal of Orthopaedic Trauma 2016;18(4):365-368
Digital technology is a hot spot in the orthopedic research in recent years.Computer-aided orthopaedic surgery is a kind of interdisciplinary and frontier technology,usually involving preoperative design and plan,virtual operation,intraoperative navigation and implementation.The application of computer-aided techniques in the treatment of proximal humeral fractures was summarized in this article.We intended to inform surgeons of the digital techniques which have been efficiently used in the clinic and improved the efficacy of PHF treatment.
2.Morphological study of tibial plateau based on three-dimensional computed tomography image and its clinical significance
Yijie ZHANG ; Yanxi CHEN ; Kun ZHANG ; Minfei QIANG ; Xiaoyang JIA ; Haobo LI ; Yuchen JIANG
Chinese Journal of Trauma 2017;33(1):63-68
Objective To investigate the three-dimensional morphological characteristics of tibial plateau based on CT image post-processing technique and analyze its significance in preoperative planning of tibial plateau fractures.Methods Multi-slice spiral CT data of 98 humans (56 males and 42 females) with normal tibial plateau and 30 patients (15 males and 15 females) with tibial plateau fractures were extracted.Morphological measurements of the tibial plateau were achieved by means of a three-dimensional measurement method based on points,lines and surfaces.Differences in threedimensional parameters between genders in normal tibial plateau and differences between normal tibial plateau and tibial plateau fractures were analyzed.Results Differences of males and females were significant in width of tibial plateau [(73.2 ± 3.7) mm,(65.5 ± 3.7) mm],anteroposterior dimension of medial tibial plateau [(39.8 ± 3.5) mm,(34.8 ± 2.6) mm] and anteroposterior dimension of lateral tibial plateau [(34.0 ± 3.3) mm,(29.8 ± 3 5) mm] (P < 0.05),but not in varus inclination of tibial plateau [(3.19 ± 1.98) °,(3.16 ± 1.89) °],medial plateau posterior slope [(7.31 ± 3.04) °,(8.16 ± 2.46)°] and lateral plateau posterior slope [(5.23 ±2.35)°,(5.60 ±2.55)°] (P >0.05).Above parameters in three-dimensional morphological measurements of tibibial plateau fractures varied compared to the normal reference value (P < 0.05).Intraclass correlation coefficient (ICC) for intra-observe and inter-observer agreement in normal tibial plateau measurement was excellent.Conclusions Present research provides a series of scientific and objective data for preoperative planning of tibial plateau fractures.Measurements of tibial plateau can assist the evaluation of reduction of tibial plateau fractures.
3.Application of computer-assisted pre-operation plan for the treatment of geriatric intertrochanteric femoral fractures
Minfei QIANG ; Yanxi CHEN ; Kun ZHANG ; Xiaoyang JIA ; Yijie ZHANG ; Yuchen JIANG ; Haobo LI ; Song CHEN
Chinese Journal of Orthopaedics 2017;37(17):1061-1068
Objective To discuss the curative effect of computer assisted pre-operation plan (CAPP) in treating the geriatric intertrochanteric femoral fracture.Methods The data of intertrochanteric fractures treated with PFNA-Ⅱ between March 2012 and June 2015 were retrospectively analyzed.They were divided into two groups by preoperative design.One group was the CAPP group consisting of 53 patients with a mean age of 75.3 years (range,60-92 years).According to the Evans Classification,there were 12 Evans type Ⅰb,9 Evans type Ⅰc,15 Evans type Ⅰd and 17 Evans type Ⅱ fractures.The other group was the non-CAPP group consisting of 74 patients with a mean age of 76.6 years (range,62-95 years).There were 18 Evans type Ⅰb,15 Evans type Ⅰc,20 Evans type Ⅰd and 21 Evans type Ⅱ fractures.Operation time,intraoperative blood loss,times of fluoroscopy during operation and days of hospital stay were compared.The hip joint function was evaluated by Harris score at the final follow-up.Results The CAPP meanly cost 24.7 min.The consistency of the surgery and CAPP was up to 100%.In the CAPP group,the average operation time was 46.8±6.5 min;the average times of fluoroscopy during operation were 12.0±2.3 times;and the average blood loss was 154.4±27.6 ml.In the non-CAPP group,the average operation time was 57.8±10.3 min;the average times of fluoroscopy during operation was 20.9±3.2;and the average blood loss was 235.0±65.8 ml.All above data in the CAPP group were significantly lower than those in the non-CAPP group.The mean days of hospital stay were 13.9±1.3 days in the CAPP group and 14.3±1.4 days in non-CAPP group.The days of hospital stay had no significant difference between the two groups.Forty-five patients with an average follow-up period of 18.3 months were reviewed in the CAPP group.Fifty patients were followed up with an average period of 19.2 months in the non-CAPP group.At the final follow-up,the average Harris score was 88.6±2.8 points (range,84-96 points) in the CAPP group and 87.5±3.2 points (range,80-95 points) in the non-CAPP group.Conclusion CAPP system is convenient and efficient.It can facilitate the treatment of intertrochanteric fracture effectively.
4.The Changes of Neurocognitive Function in Early Stage in Patients with First-Episode Schizophrenia
Jia HE ; Dongyan KONG ; Fangmiao CAI ; Shujie GONG ; Yanqing ZHENG ; Xiaoyang ZHANG ; Mingying LUO
Progress in Modern Biomedicine 2017;17(22):4277-4280,4298
Objective:To evaluate the changes of neurocognitive function in early stage in patients with first-episode schizophrenia.Methods:In this study,73 cases of patients with first-episode schizophrenia (research group) and 75 cases of health person (control group) were selected from January 2015 to January 2016 in our hospital.The neurocognitive function was evaluated by neuro-psychological testing tool and the data between two group were compared.Results:Scores of delayed recall,total recall,3 trial,2 trial and 1 trial of research group were lower than those of control group in BVMT-R test,and the difference was statistically significant (P<0.05).In HVLT-R test,the scores of total delay,3 trial and 2 trial of research group were significantly lower than those of control group (P<0.05).The consuming time of dominant hands and subdominant hands in pegboard tasks were significantly higher in research group than in control group (P<0.05).Conpletion time of connection test A,color connection 1 and 2 in connection test of research group were significantly higher than those of control group (P<0.05).Attempt number and correct number in research group in PASAT test were significantly lower than in control group (P<0.05).Number of search errors in research group was higher than in control group,while number of search correct,search total score and digital sign score were significantly lower than in control group (P<0.05).Total number of words,color and color / word count in research group were lower than in control group in Stroop color word test,and the difference was statistically significant (P<0.05).WMS-Ⅲ test results between two group had no significant difference (P>0.05).Conclusion:The neurocognitive function in early stage in patients with first-episode schizophrenia has been extensively damaged.
5.Impacts of Patient Care on Doctor-patient Trust-Field Studies Based on Capital City Tertiary Hospitals
Chumeng GAO ; Xiaoyang WANG ; Zhaofeng LYU ; Rui GUO ; Lanqiu LIU ; Jia YANG ; Taoxin MO ; Jingnan MIAO ; Yifan LI
Chinese Medical Ethics 2015;(5):699-702
Objective:To understand the status of outpatients′medical care and their impact on the doctor -pa-tient trust in Beijing .Methods:Three tertiary hospitals were selected due to most concentrated high -quality medi-cal resources , the largest number of patient visits , universalism and particularism trust could be compared , taking field observations , personal interviews and questionnaires methods .Results:The main factors affecting clinical doctor-patient trust are time, the doctor skills, medical ethics, medical and prescription drug division , etc.are appropriate and effective .Conclusion:Play the role of pyramidmedical system′s overall effectiveness , and es-tablish a patient-centered system for outpatient care as soon as possible a comprehensive grasp of the overall con -struction team doctor , continue to strengthen the standardized management of medication .
6.Efficacy evaluation of early debridement implant removal for infection after internal fixation of tibial fracture
Qinghui HAN ; Kun ZHANG ; Yanxi CHEN ; Minfei QIANG ; Xiaoyang JIA ; Xiaoying TANG
Chinese Journal of Trauma 2018;34(11):995-1000
Objective To compare the efficacy of early and delayed removal of debridement implant for infection after internal fixation of tibial fracture.Methods A retrospective case control study was conducted on the clinical data of 27 patients with tibial fractures who received plate or screw internal fixation admitted to the East Hospital Affiliated to Tongji University from March 2005 to September 2016.There were 21 males and six females,aged 18-81 years [(41.6 ± 14.3)years].According to the treatment methods,the patients were divided into the delayed implant removal group (Group A,10 patients) and the early implant removal group (Group B,17 patients).Group A was given debridement and anti infection treatment followed by continuous dressing change,and the implant was removed after the fractures were healed.Group B was given debridement and implant removal after one month of anti infection treatment and continuous dressing change when the infection was not clearly controlled.Patients with stable fracture ends were given only negative pressure closed drainage (VSD),and those with instable fracture ends were given external fixation and VSD.The time from infection to implant removal,the time of infection control,the fracture nonunion rate,the chronic bone infection rate,the knee joint function score of the American Hospital for Special Surgery (HSS),and the American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot scale were compared between the two groups.Results All patients were followed up for 13-47 months,with the average of 28.4 months.There were significant differences between Group A and Group B in terms of the time from infection to implant removal [(49.9 17.1) weeks ∶ (19.3 ± 9.2) weeks],the time of infection control [(85.3 ±78.3)days∶ (6.3 ±2.8)days],fracture nonunion rate (30% ∶ 0),and the chronic osteomyelitis incidence (30% ∶ 0) (all P <0.05).No significant differences were found in HSS knee joint function score and AOFAS ankle hindfoot scale between the two groups (both P > 0.05).Conclusion For patients with postoperative infection after internal fixation for tibial fracture,early thorough debridement and implant removal can quickly control the infection and reduce the incidence of nonunion and osteomyelitis.
7.Measurement of related predictive parameters of osteoporotic hip fracture based on three-dimensional CT reconstruction technique and its clinical significance
Zhaoman SHI ; Minfei QIANG ; Xiaoyang JIA ; Kun ZHANG ; Yanxi CHEN
Chinese Journal of Orthopaedics 2021;41(15):1025-1032
Objective:To analyze the application value of three-dimensional computed tomography (3-D CT) reconstruction technique in the evaluation of related predictive parameters of osteoporotic hip fractures.Methods:From February 2014 to March 2019, 106 patients with hip fracture who underwent dual-energy X-ray bone density test of T≤ -2.5 SD on the hip were analyzed retrospectively. There were 58 males and 48 females; Age 73.50±5.59 years old (range, 65-88 years old); Height 170.12±7.43 cm (range, 152-187 cm); Weight (69.26±11.85) kg (range, 37-94 kg); Body mass index 23.60±2.37 kg/m 2 (range, 18.3-28.9 kg/m 2); There were 32 cases of femoral neck fractures, 68 cases of intertrochanteric fractures and 6 cases of subtrochanteric fractures. Anatomic parameters of the hip were the cortical thickness index (CTI), hip axis length (HAL), and femoral offset (FO). The above-mentioned predictive parameters of the hip fractures were measured based on X-ray and 3-D CT reconstruction images. Comparison of the two methods were analyzed using paired t test, liner Pearson analysis, and Bland-Altman analysis. Pearson analysis was used to evaluate correlation between CTI, HAL, and FO and T value. Results:106 cases were compared and analyzed with the measured values of X-ray and 3-D CT reconstruction images according to the preset measurement scheme. The mean value of CTI measured by conventional X-ray measurement method was 0.31±0.05, and the mean value of CTI measured by 3-D CT reconstruction images was 0.31±0.05. The result was not statistically significant ( t=0.938, P=0.35). The mean values of HAL, FO measured by conventional X-ray measurement method were 123.35±12.74 mm, 43.99±2.81 mm, and the mean values of HAL, FO measured by 3-D CT reconstruction images were 121.11±14.51 mm, 40.73±3.11 mm. The results were statistically different ( t=2.578, 18.502; all P< 0.05). The Bland-Altman results showed that there was no difference in the consistency of the two measurement methods for CTI while the measurement results of HAL, FO were quite different. CTI and HAL showed strong correlations with the T scores respectively ( r=0.784, -0.748; P< 0.001). Conclusion:Based on 3-D CT reconstruction technique, accurate measurement of related predictive parameters of osteoporotic hip fractures can be realized, which provides theoretical basis for the evaluation of osteoporotic hip fractures in the elderly and the formulation of accurate rehabilitation treatment plan.
8. The treatment of pilon fractures with a single medial locking plate and lag screwsbased on computer-assisted pre-opera-tion plan
Minfei QIANG ; Kun ZHANG ; Yanxi CHEN ; Xiaoyang JIA ; Song CHEN ; Shuguang WANG ; Xiong WANG
Chinese Journal of Orthopaedics 2019;39(9):543-549
Objective:
evaluate the efficacy of a single medial locking plate and lag screws based on computer-assisted pre-operation plan (CAPP) for the treatment of pilon fractures.
Methods:
Between 2013 and 2016, data of 27 patients with pilon fractures who were treated using a single medial locking and lag screws based on CAPP were retrospectively analyzed. All the cas-es were AO/OTA 43-C type pilon fractures. According to the Rüedi-Allgöwer classification, there were 5 cases of type Ⅱ and 22 cases of type Ⅲ. Among 27 patients, 19 patients had fibula fracture. CAPP was performed for all fractures, including simulated re-duction, virtual surgery, and implantation of internal fixation. The time of CAPP, intraoperative realization of preoperative plan, op-eration time, intraoperative blood loss, and pre- and post-operative range of motion of ankle were recorded. Functional outcomes at final follow up were assessed using American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot scale, visual analogue scale (VAS).
Results:
The mean time of CAPP was 25.8 minutes (range, 14-30 minutes). The average operating time was 138.5 minutes. The average intraoperative blood loss was 225.9 ml. All the twenty-seven patients were followed up for an average period of 18.6 months. The average AOFAS score, VAS score at the final follow-up was 82.9, 2.7 points respectively, which was signifi-cantly improved compared with those before operation (
9.Application of three-dimensional morphological measurement in treatment of displaced intra-articular calcaneal fractures in the elderly
Xiong WANG ; Minfei QIANG ; Yanxi CHEN ; Kun ZHANG ; Xiaoyang JIA
Chinese Journal of Trauma 2020;36(6):520-525
Objective:To investigate the application value of three-dimensional morphological measurement in the treatment of displaced intra-articular calcaneal fractures in the elderly.Methods:A retrospective case series study was conducted to analyze the clinical data of 44 patients with displaced intra-articular calcaneal fractures admitted to East Hospital Affiliated to Tongji University from January 2015 to January 2018. There were 33 males and 11 females, aged 60-88 years (mean, 67.2 years). According to Sanders classification, 35 patients were with type II fractures and 9 with type III fractures. All patients were evaluated with digital technology and received open reduction and internal fixation. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency and complications were recorded. Three-dimensional morphological parameters of calcaneal fractures were compared before and at latest follow-up, including horizontal length of the calcaneus, height of the posterior articular facet, height and length of the anterior process, Gissane angle, and B?hler angle. The visual analogue scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) ankle-hind foot function score were also compared.Results:All patients were followed up for 12-30 months (mean, 17.1 months). There were 31 patients with posterior articular facet depression more than 2 mm, and 13 patients showed the back shift of the whole or part of posterior articular facet more than 3 mm and varying degree of fracture of the upper or lateral wall part of calcaneus body. The operative time was 55-105 minutes (mean, 85.1 minutes). The intraoperative blood loss was 30-130 ml (mean, 74.9 ml). The intraoperative fluoroscopy frequency was 5-8 times (mean, 6.5 times). During the operation, the internal fixation was not changed. Two patients suffered from skin incision infection after operation. At latest follow-up, the horizontal length of the calcaneus, height of the posterior articular facet, Gissane angle and B?hler angle were significantly improved from that before operation [(76.9±4.1)mm vs. (75.5±5.2)mm, (24.2±2.1)mm vs. (22.5±2.9)mm, (29.0±6.2)° vs. (18.3±5.5)°, (124.8±7.2)° vs. (107.6±8.5)°, respectively] ( P<0.01). No significance was found in the height and length of the anterior process ( P>0.05). At latest follow-up, the VAS and AOFAS ankle-hind foot function score were also significantly improved compared to preoperation [(1.1±0.9)points vs. (4.4±0.9)points, (86.4±6.2)points vs. (49.9±6.3)points, respectively] ( P<0.01). AOFAS ankle-hind foot function score was excellent in 13 patients, good in 26, fair in 5, with the excellent and good rate of 87%. Conclusion:Three-dimensional morphological measurement can fully evaluate the damage of calcaneal fractures and provide data reference for the preoperative planning of open reduction and internal fixation in the elderly, so as to restore the calcaneus structure, relieve pain and improve ankle function.
10.Research on dynamic visual function difference
Jun CAI ; Dawei TIAN ; Po XU ; Yange ZHANG ; Qingjun ZHANG ; Xiaoyang YANG ; Yongsheng CHEN ; Lei SONE ; Mei LONG ; Yingjuan ZHENG ; Yuanyuan JIANG ; Shan CHEN ; Sujiang XIE ; Hongbo JIA ; Jie WANG
Military Medical Sciences 2014;(5):368-370
Objective To detect the dynamic visual acuity ( DVA) before and after vestibular habituation of subjects in order to optimize the DVA assessment criteria .Methods The vestibular function examination system was applied to the detection of static and dynamic visual function in 16 healthy subjects .Results When the speed of left or right swinging was fast enough , DVA before and after vestibular habituation was different .Conclusion Subjects with vestibular habituation can reduce their sensitivity to the vestibular system , the changes in DVA are better than before habituation , and the vestib-ular function adaptability training may have effect on DVA .