1.Assessment of the microbiologic and clinical effects of ultrasonic scaling combining with simultaneous antimicrobial agent irrigation
Yafei WU ; Jin CHEN ; Xiaoqin ZHAO
Journal of Practical Stomatology 2000;0(05):-
Objective:To assess the clinical and microbiologic effects of ultrasonic scaling with simultanous irrigation with chlorhexidine(CHX), conventional ultrasonic scaling or subgingival irrigation. Methods: 20 teeth in 7 patients with periodontitis were equally divided into test and control group. Patients in the test group were treated by irrigation with CHX during ultrasonic scaling(Master400),those in the control with irrigating after scaling(MiNi ). Clinical assessments of bleeding on probing (BOP),probing depth (PD) were made just before and 7 and 14 days after treatment. The subgingival microbiologic examination was performed before and 0,7 and 14 days after treatment. Result: Significant reductions in PD and BOP were observed in both groups 7 and 14 days after treatment(P
2.Effect of Xingding injection on blood LN and blood C-Ⅳ in chronic renal failure.
Jingsong JIN ; Xiaoqin WANG ; Min WU ;
Chinese Journal of Practical Internal Medicine 2006;0(S1):-
Objective To observe the effect of Xingding injection on renal fuction,blood Laminin(LN)and Collegen Ⅳ(C-Ⅳ)in chronic renal failure(CRF).Methods Effect of SerumCreatinine(SCR),BloodUreaNitrogen (BUN)、Hemoglobin(Hb)、ALT、24 hupq、Laminin(LN)、Collegen Ⅳ(C-Ⅳ)was observed in CRF pa- tients.Results Compared with the controlvalues,significantly decreased the level of Scr,BUN,LN,C-Ⅳ and 24 hupq(P
3.Safety of delivering nitric oxide through nitrous oxide path in anesthesia machine
Dongya ZHANG ; Xiaoqin HU ; Jin LIU
Chinese Journal of Anesthesiology 1995;0(12):-
To evaluate the feasibility of delivering NO through N_2O path in anesthesia machine,NO at 800 ppm was delivered through nitrous oxide path in anesthesia machine SIEMENS Ventilator 710 or NARKOMED 2B,to ventilate a test lung. The minute volume of ventilation (MV) was set from 2 to 6L/min, and NO concentration from 10 to 80 ppm. NO and NO_2 concentrations were measured by hemiluminescence and electro-chemical fuel cell technique. SIEMENS Ventilator 710:Non-rebreathing model,its inspiratory limb was prolonged to 7 meters,the NO level was adjusted at 80ppm before passing through soda lime, NO and NO_2 samples were taken before absorber,after absorber, 1, 2,4 and 6 meter site in inspiratory limb. NARKOMED 2B:Oxygen flows were at the rates epual to the MV mentioned above, NO concentration was at 10,20,40,60 and 80 ppm,the inspiratory gas mixture was sampled immediately passing through absorber, NO_2 levels were less than 5.0ppm in all conditions listed above. With SIEMENS Ventilator 710, the highest level of NO_2 was 3.45 ppm before absorber and 2.43 ppm after absorber,with NARKOMED 2B,that was 3.6 ppm. As MV increased,NO_2 level before absorber decreased (P
4.Influence factors on the enflurane uptake at the lung of child suffering from congenital heart diseases
Xiaoqin ZHAO ; Jianmin ZHANG ; Jin LIU
Chinese Journal of Anesthesiology 1995;0(02):-
Objective To study the influence factors on the enflurane uptake in child with congenital heart disease(CHD).Methods Sixty children aging less than 5 years with CHD were randomly divided into four groups: in group A 15 children with atrial septal defect(ASD)or ventricular septal defect (VSD) inhaled enflurane before and after CPB;in groups B 15 children with ASD or VSD did only after CPB,in group C 15 children with tetralogy of fallot (F4) did before and after CPB;in group D 15 children with F4 did only after CPB.The concentration of enflurane (F I) was kept at 0.5%.Following inhalation of enflurane,the end tidal alveolar concentration (F E) was measured in 30 min and the time of uptake equilibrium (Tue,F E/F I=1) was recordcd.Results In group C,Tue before CPB was shorter than that before CPB and after CPB in group A,that in group B and group D (P
5.Development of the KPI system for hospital's capital projects based on key performance indicators
Weiqun ZHAO ; Ling JIN ; Xiaoqin SHEN ; Daqiu CHEN
Chinese Journal of Hospital Administration 2013;29(8):621-624
Objective To build a performance indicators measurement system for hospital's capital projects for the purpose of objective comments on project performance.Methods Based on theories and practice of key performance indicators,building the KPI system for hospital's capital projects with the construction project of a hospital in another place.Results Level-1 indicators are set as business indicators and financial ones,the business indicators include three level-2 indicators and 20 level-3 indicators; the financial indicators also include one level-2 indicator and three level-3 indicators.These indicators are designed for scientific and objective appraisal of performance of the projects.Conclusion Such a KPI system can present objective appraisal of the project performance,and the performance management.
6.Comparison of analgesic effect of ultrasound-guided continuous femoral nerve block after total knee ath-roplasty
Xiaoqin XU ; Xudong XU ; Xianbing JIN ; Zhifeng SHENG ; Ruibin LU
The Journal of Clinical Anesthesiology 2014;(7):634-636
Objective To observe the analgesic effect of ultrasound-guided and nerve stimulator after artificial total knee athroplasty(TKA).Methods Forty elective cases receiving TKA under gen-eral anesthesia were randomly allocated into the ultrasound group (group C)and stimulator group (group S).The time for nerve block,onset time and complications were recorded in both groups. Results Compared to group S,the time for nerve block and onset time was significantly shortened in group C (P <0.05).There was no statistical difference in times of pressing analgesic pump and VAS score in postoperative 48 h.One patient suffered from nerve injury and two underwent vascular dam-age and hematoma in group S,while no complication was found in group C.Conclusion Compared to nerve stimulator,ultrasound-guided continuous femoral nerve block(CFNB)may reduce nerve block time and onset time and decrease complications,so that to increase safety of CFNB.
7.Expression and purification of recombinant human Cosmc extracellular domain in Sf-9 insect cells
Qiuling XIE ; Yue TAO ; Xiaoqin ZHANG ; Xi MO ; Yanliang JIN
Chinese Journal of Immunology 2016;32(10):1507-1511,1518
Objective:In the present study,Bac-to-Bac baculovirus expression system was used to obtain recombinant human Cosmc extracellular domain protein,which can lay the foundation for the research about the structure and function of Cosmc protein in vitro,and simultaneously provide ideas for the research of O-glycosylation and related diseases. Methods: The Cosmc extracellular domain ( Cosmc-ED) gene was cloned into a transfer vector pFastBac1 to form the recombinant donor plasmid pFastBac1-Cosmc ED, which was transformed into competent cells DH10Bac. By using blue-white selection and PCR analysis,we could obtain recombinant shuttle vector rBacmid-Cosmc ED. Then, the recombinant gene DNA of rBacmid-Cosmc ED was used to transfect Sf-9 mediated by cationic lipid formulation,and the recombinant baculovirus bacmid was obtained,which was further used to infect the serum-free cell Sf-9 to express Cosmc-ED in the supernatant. Then the protein of interest was detected by SDS-PAGE and Western blot and purified with Ni-NTA affinity column. Results:SDS-PAGE and Western blot analysis showed a specific band about 33 kD,consistent with the interest protein. Mass spectrometry results further prove that the protein was Cosmc extracellular domain protein. Conclusion: Human Cosmc-ED protein can be successfully expressed in Sf-9 insect cells and laid basis for subsequent studies.
8.Double-equilibration technique for measuring liquid/gas partition coefficients of isoflurane
Mingzheng LIU ; Shijun ZHAO ; Xiaoqin HU ; Jin LIU
Chinese Journal of Anesthesiology 1995;0(12):-
This study was designed to establish methods to measure partition coefficients of inhaled anesthetics at 1 atmosphere and 37 C by using syringe-flask double equilibration technique. Olive oil/gas (O/G), saline/gas (S/G), and water/gas (W/G) partition coefficients of isoflurane were 90.20?2.01, 0.6256?0.109, and 0. 741?0.025, respectively. Even though O/G was 150 folds of S/G,coefficients of variation for both O/G and S/G were less than 3%. The results indicate that the established double-equilibration technique has a very high repeatability and is applicable to wide ranges of inhaled anesthetics' solubilities.
9.Influence of washable type subglottic attract on incidence of ventilator- associated pneumonia in patients with mechanical ventilation
Shenqin DONG ; Xiaoqing SHAO ; Chunyan JIN ; Rong SUN ; Guangyan ZHANG ; Xiaoqin WU
Chinese Journal of Practical Nursing 2012;28(7):22-25
ObjectiveTo explore the influence of washable type subglottic attract on incidence of ventilator-associated pneumonia (VAP) in patients with mechanical ventilation. Methods356 cases in need of mechanical ventilation from July 2009 to July 2010 in our hospital were chosen as the research object.They were randomly divided into the observation group and the control group with 178 cases in each group.The control group was treated with conventional endotracheal tube for mechanical ventilation.The observation group used washable type subglottic endotracheal tube to attract for mechanical ventilation.The VAP rate for the two groups occurred during mechanical ventilation in ventilator was compared.Migration of the dominant bacteria of the subglottic secretion was detected,underwent pathogenic examination and drug sensitivity test. ResultsThe VAP rate was significantly lower in the observation group than that of the control group.186 bacteria strains were detected from subglottic secretion,and 169 were detected from lower respiratory tract. ConclusionsWashable type subglottic attract for mechanical ventilation can reduce the risk of ventilator-associated pneumonia for patients with mechanical ventilation significantly,and it is worthy of clinical application.
10.Effect of CT scanning parameters on CT number
Wenxian PENG ; Tianzhou PENG ; Xiaoqin YE ; Yimou FU ; Huiping PAN ; Yuantong GAO ; Guangbo JIN
Chinese Journal of Radiological Medicine and Protection 2010;30(1):79-81
Objective To study the effects on tissue CT number caused by scan protocols.Methods The phantom was repeatedly scanned in different protocols by changing only one of parameters,such as X-ray tube voltage,mAs and recon kernel,while other parameters were ketp unchanged.The CT number of different materials in phantom were measured and analyzed.Results The CT numbers of tissues changed remarkably with the tube voltage and had different relativity for different tissues.The CT numbers had positive correlation with kV for such maierials as polyethyle,lexan,perspex,but for teflon the correlation was negative.The mAs and recon kernel had no effects on CT number.Conclusions The CT number of tissue changes with scanning X-ray tube voltage,so the setting of scan parameters should be taken into account in image diagnosis and radiotherapy.