1.The development of the portable monitor for HRV
Xiaonian TANG ; Gang AN ; Dayuan ZHAO ; Huiqing ZHANG
Chinese Medical Equipment Journal 1989;0(04):-
Based on sciences of medicine, electronics and computer, this paper details such information of the portable monitor of HRV as the designing principles and essentials of the software and hardware designs. The monitor has a lot of virtues including being lightweight, integrative, visual and controllable. It can not only suit the test of physical and mental work intensity but also offer important HRV parameter for clinical diagnoses of cardiocerebral vascular diseases. It can also be used by individuals, families and service stations.
2.DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
Yuhai TANG ; Xiaonian HAN ; Chunling YU ; Yuanyuan SUN ; Hong YAO
Journal of Pharmaceutical Analysis 2006;18(2):136-138
Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can sensitize obviously the chemiluminesence (CL) intensity of the reaction of luminol with KIO4, the sensitized CL intensity is proportional to the concentration of tetracycline and oxytetracycline. So, a new flow-injection CL method has been developed. The optimum chemical conditions for the CL reaction were investigated. Results Under the optimized conditions (KIO4 concentration: 1.0×10-5 mol/L; NaOH concentration: 0.1mol/L; luminol concentration: 1.0×10-4mol/L), tetracycline and oxytetracycline were determined. The linear range of the working curves was 1.0×10-7 -1.0×10-4g/mL, the detection limits was 1.0×10-8g/mL and 1.1×10-8g/mL, and the relative standard deviation was 2.6% (CS=1.0×10-6g/mL; n=11) and 2.0% (CS=1.0×10-6g/mL; n=11) respectively. Conclusion The method is simple, rapid, and sensitive, and it has been successfully applied to the the determination of tetracycline and oxytetracycline tablets, the mean recoveries being 99.7% and 98.8% respectively.
3.The determination of perphenazine by a new flow-injection chemiluminescence method
Jingfeng YI ; Xiaonian HAN ; Chunling YU ; Yuhai TANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2004;0(05):-
Objective To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method for the determination of perphenazine. Methods In HNO_3 medium, perphenazine could be oxidated by ceriuim (IV) and CL was proportional to the perphenazine concentration without any sensitizers. Thus, a new flow-injection CL method was developed. Results Under the optimized conditions, the proposed method allowed the determination range within 1.0?10~ -7 -7.0?10~ -5 g/mL with the detection limit of 8.0?10~ -8 g/mL. Eleven parallel assays were conducted on perphenazine of 1.0?10~ -6 g/mL, with the relative standard deviation of 1.8%. Conclusion The method is simple, rapid, precise, and sensitive, and has broad linear range; therefore, it has been applied to the the determination of the perphenazine in tablets with satisfactory results.