1.Low amplitude dorsal ulnar cutaneous nerve sensory nerve action potential from cross over innervation. Can nerve ultrasound help?
Xiaoke Dong ; Aravinda K Therimadasamy ; Einar P Wilder-Smith
Neurology Asia 2017;22(1):73-75
The ulnar dorsal aspect of the hand is predominantly innervated by the dorsal ulnar cutaneous nerve
with variable input from the superficial radial cutaneous nerve. This cross innervation can cause
difficulty in interpreting low amplitude sensory nerve action potential for the dorsal ulnar cutaneous
nerve particularly when facing suspected ulnar neuropathyat the elbow. In three subjects with low
dorsal ulnar cutaneous sensory nerve action potential amplitude due to cross over with the superficial
radial nerve, we compared amplitude with nerve circumference and fascicular count as measured by
ultrasound. Dorsal ulnar cutaneous nerve circumference was significantly smaller where there was
low sensory nerve action potential amplitude and showed fewer fascicles. Nerve ultrasonography
may be a useful additional test modality to determine if low dorsal ulnar cutaneous nerve amplitude
is physiological.
2.Bone regeneration with bone marrow mesenchymal stem cells, platelet rich plasma and decellularized cartilage matrices complex
Xiaoke FENG ; Yan DONG ; Zhiye LI ; Wei WU ; Yimin ZHAO
Journal of Practical Stomatology 2017;33(2):148-151
Objective:To study the bone regeneration capacity of the complex of bone marrow mesenchymal stem cells(BMSCs) and platelet rich plasma (PRP) with decellularized cartilage matrix (DCM).Methods:BMSCs were isolated from young rabbit and cultured;PRP were prepared from the fresh blood of rabbit and the DCM were come from the fresh ears of rabbits and processed into a mixture of BMSCs-PRP-DCM.The mixture was injected subcutaneously into nude mice,8 weeks after injection bone regeneration was examine by HE staining and Massons staining decellularization.Results:The BMSCs show good differentiation capacity in vitro and the cartilage fragments were well decellularized.Excellent endochondral ossification ability of the complex was observed by in vivo experiment.Conclusion:The BMSCs-PRP-DCM complex has good capacity of endochondral ossification.
3.Study on Essential Oil in the Seeds ofDescurainia Sophia (L.) Webb ex Prantl by GC-MS Analysis
Jianhong GONG ; Yanli ZHANG ; Weisheng FENG ; Haixu KUANG ; Xiaoke ZHENG ; Mengke DONG ; Bei PAN
World Science and Technology-Modernization of Traditional Chinese Medicine 2014;(9):1942-1945
The analysis of essential oil in seeds ofDeseurainia sophia provided an experimental basis for further research on essential oil activity test at the first time. Essential oil was extracted by steam distillation method. Analysis and identification were made by gas chromatography-mass spectrometry (GC-MS) technology in combination with retention indices. A total of 33 components in seeds ofD. sophia were detected by GC-MS and 28 compounds were identified by MS in combination with Kovats retention index. The compounds with high contents were as follows: 3-methylene-nonane (68.14%), 1,3-diazine (29.32%), 2-n-butylacrolein (0.58%), methyl nipecotate (0.43%), 4-oxo-butanenitrile (0.31%), 8-chloro-neoisol-ongifolene (0.25%) and so on. It was concluded that 28 volatile components were identified by GC-MS combined with retention indices. The total detected components were 99.91%. This method was able to improve the accuracy of qualitative detection results.
4.Assessment of right ventricular function in mice with pulmonary hypertensive by pressure-volume loops
Xiaoke SHANG ; Rong LU ; Mei LIU ; Shuna XIAO ; Bin WANG ; Changdong ZHANG ; Nianguo DONG
Chinese Journal of Interventional Cardiology 2017;25(5):271-275
Objective To study on the evaluation of haemodynamics in the normal and pulmonary hypertensive mouse hearts using pressure volume loops measured by electric catheter.Methods Compared the difference in haemodynamics between mice exposed to chronic hypoxia for 10 days,which causes hypoxia-induced pulmonary hypertension (experimental group,n =8),and mice raised under normal atmospheric pressure (control group,n =8).The right carotid artery was cannulated with a 1.2 F catheter and advanced into the ascending aorta,then punctured towards the right ventricular apex.A 1.2 F admittance pressure-volume catheter was introduced using a 20-gauge needle to obtain the pressure-volume measurements and calculate hemodynamic parameters.Results There were no significant differences in average by weight,ratio of right atrial weight to body weight,left atrial weight/body weight,left ventricular free wall and septum weight/body weight between the 2 groups(all P > 0.05).The ratio of right rentricle/left rentricle and septum weight as well as right rentricular weight/body weight was increased in the experimental group and of significant difference when compared to the control.The mice in in the experimental group had a 61% mean decrease in cardiac output,a 55% decrease in ejection fraction,and a 63% decrease in ventricular compliance(P <0.05).The increase in dP/dtmax-EDVand PRSWfound in the experimental group reflected significant increase in myocardial contractility.Increase in Ees was observed but without significant difference as compared to the control.Ea significantly increased in the experimental group resulting in significant decrease in Ees/Ea from (0.71 ±0.27) to (0.35 ±0.17) (P< 0.005).Conclusion This study demonstrates the feasibility of obtaining RV pressure-volume measurements in mice using electric catheter.These measurements provide insight into right ventricular-pulmonary artery interactions in healthy and diseased conditions.
5.Animal models of cerebral venous and sinus thrombosis
Ying WEI ; Xinbin GUO ; Sheng GUAN ; Xin DENG ; Zibo WANG ; Xiaoke LU ; Yanhua DONG
International Journal of Cerebrovascular Diseases 2017;25(3):281-284
Cerebral venous and sinus Thrombosis (CVST) is a rare ischemic cerebrovascular disease,the lesions of 60% patients are involved in multiple venous sinus,of which the superior sagittal sinus thrombosis is most common.The pathogenesis and pathophysiology of CVST has not yet been fully elucidated,and the establishment of stable and ideal animal models can provide a basis for the study of its development,prognosis and efficacy assessment.This article summarizes the characteristics and advantages of several available CVST models,but each method has its own limitations.Therefore,the establishment of a more ideal animal model will help to fully understand the pathogenesis and pathological process of CVST.
6.Establishment of cerebral venous sinus thrombosis model in rabbits by using ferric chloride combined with thrombin injection
Ying WEI ; Sheng GUAN ; Xinbin GUO ; Xin DENG ; Zibo WANG ; Dongdong LI ; Xiaoke LU ; Yanhua DONG
Journal of Interventional Radiology 2018;27(2):151-156
Objective To discuss the establishment of cerebral venous sinus thrombosis (CVST) model in rabbits by local application of ferric chloride at sinuses sagittalis superior (SSS) combined with thrombin injection, and to evaluate its feasibility and application value. Methods A total of 39 New Zealand white rabbits were randomly and equally divided into three groups with 13 rabbits in each group, local application of cotton piece saturated with saline at SSS for 10 minutes was performed for the rabbits of group A, SSS local application of cotton piece saturated with 40% ferric chloride for 10 minutes was adopted for the rabbits of group B, while SSS local application of cotton piece saturated with 40% ferric chloride for 5 minutes together with injection of thrombin was carried out for the rabbits of group C. Whole cerebral DSA was performed immediately after modeling to judge if there was formation of thrombosis. Two days after the modeling, every 3 rabbits from each group were sacrificed to make 2, 3, 5-chloride triphenyl tetrazole (TTC) staining. Seven days after the modeling, the remaining 10 rabbits of each group were examined with DSA, the vascular recanalization rates were calculated, and the histopathological examination was made. Results In group B and group C, SSS thrombosis with surrounding cerebral infarction, edema, inflammatory cell aggregation and other pathological changes were observed. The 7-day vascular recanalization rate in group C was strikingly lower than that in group B (10% vs 70%, P<0.05). Surrounding cortical vein thrombus and subcortex petechial hemorrhages were obviously seen in group C. Conclusion For the establishment of CVST model in rabbits, local application of ferric chloride at SSS together with thrombin injection is effective and feasible. The thrombus thus induced is quite stable, and its pathogenesis and pathophysiology are quite similar to clinical manifestations. Therefore, this method can be used for basic research and clinical trials of CVST.
7.Latest progress of heart failure instrument treatment
Xiaoke SHANG ; Changdong ZHANG ; Nianguo DONG
Chinese Journal of Thoracic and Cardiovascular Surgery 2023;39(3):129-133
With the rapid and in-depth development of interventional treatment of structural heart disease, the instrument treatment of heart failure (heart failure) will become the main way of heart failure treatment in the future. There are a large number of patients with heart failure. Due to different etiology, pathogenesis, course of disease and individual differences, it is sometimes difficult to achieve satisfactory results in medical treatment. The treatment of heart failure based on instruments or equipment provides the dawn of survival for patients who are ineffective in medical treatment. In recent years, the research and development and clinical application of various heart failure devices have mushroomed, but their effectiveness, safety and practicality still need to be verified by strict clinical trials and evidence-based medical evidence. This article briefly reviews the main progress and development prospects of instrument therapy for heart failure in recent years.
8.Evaluation of the value of patient data-based real-time quality control in improving the effectiveness of indoor quality management
Minge LIU ; Fangfang FENG ; Xucai DONG ; Hailing XIONG ; Bin LI ; Dongmei WEN ; Xiaoke HAO ; Xianfei ZENG
Chinese Journal of Laboratory Medicine 2024;47(10):1186-1191
Objective:To explore the application value of patient data-based real-time quality control (PBRTQC) in enhancing the effectiveness of internal quality control (IQC) management.Methods:From the PBRTQC real-time quality control intelligent monitoring platform integrated with the laboratory information system (LIS), a total of 35,631 test results of red blood cell (RBC) count, white blood cell (WBC) count, and dehydroepiandrosterone sulfate (DHEA-S) were collected from patients of the Department of General Xi'an Area Medical Laboratory Center from August 1, 2023, to April 1, 2024. The platform was used in patient data distribution characteristics test, EWMA real-time quality control chart procedure establishment, performance validation, effect evaluation, best procedure selection, and real-time operation. The performance evaluation indexes of the best PBRTQC procedure establishment, the cut-off limit range, weighting coefficient, cumulative mean, standard deviation (SD), coefficient of variation ( CV) of the EWMA real-time quality control chart, and the cumulative mean, SD, and CV of its internal quality control data in the same period were counted, and at the same time compared with the quality target (1/3TEa). Coefficient of variation analyses were performed to compare the quality control status of PBRTQC and conventional internal quality control in the presence of warning or alarm prompts based on quality control process records, and alarm messages. Results:The evaluation indexes of the optimal procedures for RBC count, WBC count, and DHEA-S were the probability of error detection (Ped) between 93%-97% and greater than 90%, the false positive rate (FPR) between 0.0%-0.5%, the false negative rate (FNR) between 3.0%-7.0%, and the average number of the patient sample until error detection (ANPed) between 5-11, which is in line with the optimal quality control efficacy quality requirements for the PBRTQC procedure. The patient outcome cut-off concentrations for the optimal procedure EWMA quality control charts ranged from RBC count (3.92-5.16)×10 12/L, WBC count (4.28-7.50)×10 9/L, and DHEA-S (830-2 160) μg/L; (2 160-4 210) μg/L. The weighting coefficients were 0.05, 0.03, and 0.03, respectively. The real-world application of the EWMA real-time quality control charts showed stable and excellent analytical performance of the measurement system, such as out-of-control alarm: RBC count, 1 true alarm, Ped of 95.85%, and FPR of 0%. The cumulative CV of EWMA was less than the quality target; the cumulative CV of DHEA-S was 7.66% and 9.47%, respectively, and the cumulative CV of low level was greater than the quality target (8.33%), and the cumulative CV of high and low levels were 4.12% and 6.25%. Conclusion:The PBRTQC EWMA method can monitor the patient data - in real-time and continuous way. It can also dynamically identify and provide early indication of small changes in analytical performance during the analysis process, and can be used as a supplement to quality control products to improve the efficacy of laboratory quality management.
9.Echocardiographic evaluation of the domestic D-Shant device for treatment of patients with chronic heart failure
Yi ZHOU ; He LI ; Yuman LI ; Lingyun FANG ; Jie LIU ; Wenqian WU ; Zhenxing SUN ; Ziming ZHANG ; Lin HE ; Yihan CHEN ; Yuji XIE ; Xiaoke SHANG ; Nianguo DONG ; Mingxing XIE
Chinese Journal of Ultrasonography 2022;31(9):737-745
Objective:To evaluate the efficacy of the domestic D-Shant device for the treatment of patients with chronic heart failure (CHF) using echocardiography.Methods:Twenty-four CHF patients who were treated with domestic D-Shant device in Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from September 2020 to December 2021 were enrolled in the study. Pulmonary capillary wedge pressure (PCWP)/ left atrial pressure (LAP), right atrial pressure (RAP), pulmonary artery pressure, interatrial septal gradient pressure, cardiac index and pulmonary/systemic blood flow ratio (Qp/Qs) were measured before and after implantation using right heart catheterization.Left atrial end-diastolic area index (LAEDAI), left atrial end-diastolic volume index (LAEDVI), left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), left ventricular ejection fraction (LVEF), right atrial end-diastolic diameter, right ventricular end-diastolic diameter, tricuspid annular plane systolic excursion (TAPSE), right ventricular tractional area change (RVFAC), device shunt aperture, velocity and pressure, together with mitral and tricuspid regurgitation severity were measured using echocardiography before, and 1 month as well as 3 months after D-Shant device implantation. Clinical data were collected and analyzed including 6-minute walking test (6MWT), New York Heart Association (NYHA) classification and the Kansas City Cardiomyopathy Questionnaire (KCCQ). Spearman correlation analysis was used to determine the relation between the changes in PCWP/LAP as well as echocardiographic parameters before and 3 months after implantation and NYHA classification. Binary Logistic regression analysis was performed to determine the predictive factors of NYHA classification improvement at 3-month follow-up after D-Shant device implantation.Results:①D-Shant devices were successfully implanted in all patients. ②Compared with preoperative values, invasive PCWP/LAP systolic, diastolic and mean pressures, transatrial septal gradient, and pulmonary systolic, diastolic and mean pressures decreased significantly after implantation(all P<0.001); Qp/Qs increased significantly after implantation( P<0.001). ③Compared with preoperative values, TAPSE, RVFAC and pulmonary artery flow velocity increased at 1 month after implantation(all P<0.05), whereas a significant reduction in mitral regurgitation grade, and an increase in LVEF and pulmonary artery flow velocity at 3 months after implantation(all P<0.05). Right atrial end-diastolic diameter, right ventricular end-diastolic diameter, LAEDAI, LAEDVI, LVEDVI, LVESVI, ratio of early to late diastolic peak velocities of mitral inflow(E/A), systolic peak velocity of mitral annulus at septal site(S′), ratio of early diastolic peak velocity of mitral inflow to diastolic peak velocity of mitral annulus(E/e′), pulmonary artery diameter, inferior vena cava diameter and degree of tricuspid regurgitation did not change among before, and 1 month as well as 3 months after implantation. There were no significant changes in the device shunt aperture, velocity and pressure between 1 month and 3 months after implantation(all P>0.05). ④The significant improvements in NYHA classification, KCCQ scores and 6MWT were observed at 1 and 3 months after implantation compared with preoperative values (all P<0.01). ⑤NYHA classification at 3 months after implantation was correlated with LVEF pre-post, PCWP/LAP pre-post, TAPSE pre-post and RVFAC pre-post ( rs=0.738, -0.730, 0.738, 0.723; all P<0.001). Logistic regression analysis showed that LVEF pre-post was an independent predictor for NYHA classification improvement at 3 months after implantation ( OR=0.687, 95% CI=0.475-0.992, P=0.045) . Conclusions:Domestic D-Shant device can effectively improve the cardiac function and clinical symptoms in patients with CHF. Echocardiography is a feasible and effective method to evaluate the benefits of domestic D-Shant device for the treatment of CHF.
10.Short-term clinical and echocardiographic outcomes of the novel domestic transcatheter edge-to-edge repair Neonova? system in patients with mitral regurgitation
Yun YANG ; He LI ; Wenqian WU ; Xiaoke SHANG ; Shu CHEN ; Yucheng ZHONG ; Manwei LIU ; Lin HE ; Zhenxing SUN ; Ziming ZHANG ; Yi ZHOU ; Xin ZHANG ; Nianguo DONG ; Lingyun FANG ; Mingxing XIE
Chinese Journal of Ultrasonography 2023;32(1):51-59
Objective:To investigate short-term safety, efficacy and the learning curve of this self-developed novel transcatheter valve repair system (Neonova?) in patients with mitral regurgitation, and explore the role of perioperative echocardiography.Methods:Ten patients who visited the Union Hospital of Tongji Medical College, Huazhong University of Science and Technology from June 2021 to March 2022 and met the inclusive criteria were prospectively enrolled. All the patients were at high risk of surgery with moderate to severe or severe mitral regurgitation (MR). Clamps of Neonova? were implanted under guidance of transesophageal echocardiography and digital subtraction angiography. Clinical outcomes, echocardiography indexes and learning curves of this technique were evaluated immediately after intervention, 7 d, 1 month and 3 months post-intervention.Results:The technical success rate was 100% with MR relieved in all patients immediately after intervention. The device and procedural success rates were both 90.0% with 1 patient received surgical replacement at 37 days post-intervention while the others′ reduced to mild (8/9) and moderate (1/9) MR. New York Heart Association class and the Kansas City Cardiomyopathy Questionnaire improved significantly (all P<0.001). Mean mitral valve pressure gradient didn′t increase significantly after intervention when compared with that before intervention( P=0.324), and no mitral stenosis was observed. Left ventricular end-diastolic diameter decreased significantly ( P=0.008) during follow up.Procedure duration ranged from 60 to 300 (175.8±75.2)minutes. The simple linear regression model between procedure volume and duration showed that procedure duration decreased significantly with the increase of procedure volume ( F=15.857, P=0.004). Conclusions:Neonova? implantation can improve MR severity and clinical symptoms safely and effectively. Transthoracic echocardiography and transesophageal echocardiography are essential for perioperative management of transcatheter mitral valve repair.