1.Application of Factor Analysis in Imaging Mass Spectrometric Data Analysis
Yi CHEN ; Fei TANG ; Tiegang LI ; Jiuming HE ; Zeper ABLIZ ; Litao LIU ; Xiaohao WANG
Chinese Journal of Analytical Chemistry 2014;(8):1099-1103
The factor analysis method applied in imaging mass spectrometry data analysis was studied. The imaging mass spectrometric data were obtained by air flow-assisted ionization imaging mass spectrometry method. The sample contained some symbols which were drawn on slides using three different inks ( red, blue, black) . The imaging data analyzed by factor analysis method were divided into the background, black, blue and red factor. The results showed that the scores of m/z=443. 2, 478. 4, 322. 2(344. 2) in red, blue, black factor respectively were much larger than others. Therefore, they were markers of three inks. The results accorded with actual condition well and proved that the application of factor analysis in imaging mass spectrometric data analysis was feasible. The data analysis results of factor analysis and principal component analysis were compared. The results showed that the target sample markers could be extracted by factor analysis simply and quantitatively. It was of great potential in biomarker extraction, diseases diagnose and pharmacological analysis.
2.A modified two-stage procedure strategy treat severe hypospadias with preputial flap
Yiding SHEN ; Linfeng ZHU ; Wei RU ; Fan YANG ; Xiaohao WANG ; Chang TAO ; Guangjie CHEN ; Daxing TANG
Chinese Journal of Urology 2019;40(6):431-435
Objective To investigate the effect of a modified preputial flap urethroplasty in twostage treatment of severe hypospadias.Methods The clinical characteristics of the severe hypospadias patients (41 cases) who underwent the staged urethroplasty by using the procedure of preset urethral plate with preputial flap from January 2015 to December 2016 were analyzed retrospectively.We used a modified method (modified group,23 cases):Form the distal urethra with the transected distal urethral plate by using tubularize incised plate (TIP) procedure during the first stage operation,after completely straightened the penis,urethral plate was preseted with transverse preputial flap at the penis shaft.While in the traditional group (18 cases),urethral plate was preseted with preputial flap by using Bracka procedure after transecting urethral plate.The corresponding missing part of urethra underwent urethroplasty at the second stage operation six months later.The patients in the modified group were 9 to 18 months old,and the median age was 13 months;meatus were located at the penis shaft in 10 cases,scrotum in 12 cases,perineum in 1 case.The patients in the traditional group were 9 to 18 months old,and the median age was 13 months;meatus were located at the penis shaft in 6 cases,scrotum in 10 cases,and perineum in 2 cases.There was no statistic difference in age and meatus position between the two groups.Results During the first stage operation,distal urethra was repaired by 13-19 mm,with an average of (14.5 ± 1.3) mm,and the proximal urethra was repaired by 0-6 mm,with an average of (3.1 ± 2.4) mm at the modified group.While at the traditional group,the length of proximal urethra was repaired of 0-9 mm,with an average of (5.6:±:2.9) mm.The urethral length required for reconstruction was measured during the second stage operation,with an average of (26.3:t:4.4) mm in the modified group and (40.5 ± 3.3) mm in the traditional group (P < 0.05).There were 3 case of urethral stricture after removed the catheter,with 2 cases in the modified group and 1 case in the traditional group.Postoperative follow-up was 2 to 3 years,with an average of 2.4 years.There were 3 cases (3/23,13.0%) of urethral fistula in the modified group and 3 cases (3/18,16.7%) in the traditional group.Ascended testis occured in 2 patients in the traditional group after operation.No case of urethrostenosis,diverticulum,chordee or concealed pennis was recorded.There was no significant difference in postoperative complications between the two groups (P > 0.05).Conclusions The modified staged preputial flap method shorten the new forming urethra by making full use of its own materials at the second stage operation,which was helpful to reduce complications.
3.Progress on evaluation, diagnosis and management of disorders of sex development.
Guangjie CHEN ; Xiaohao WANG ; Daxing TANG
Journal of Zhejiang University. Medical sciences 2019;48(4):358-366
Disorders of sex development (DSD) refer to a group of diseases characterized by abnormal congenital development of chromosomes, gonad or genitals with different pathophysiological changes and clinical manifestations. DSD is more common in neonates and adolescents, and neonates often show genital abnormalities while adolescents show abnormal sexual development during puberty. It is the international consensus that the scope of DSD should include basic clinical evaluation (internal and external genitalia and endocrine hormones), diagnostic confirmation (chromosome, genetic diagnosis), psychological assessment for children and family, treatment (sex assignment, hormone replacement and surgical intervention), potential fertility protection and long-term follow-up, which require the expertise of pediatric endocrinology, pediatric urology, clinical psychology, genetic disciplines, medical images and other related disciplines; that is, individualized management of children with DSD requires an experienced multidisciplinary team (MDT). This article reviews the recent progress on the evaluation, diagnosis and management of disorders of sex development.
Consensus
;
Disorders of Sex Development
;
diagnosis
;
therapy
;
Humans
;
Medicine
;
trends
;
Sexual Development
4.Replacing a smaller-size catheter after tubularized incised plate urethroplasty may decrease postoperative urethral complications
Wei RU ; Daxing TANG ; Dehua WU ; Yong HUANG ; Chang TAO ; Guangjie CHEN ; Xiaohao WANG ; Lei GAO ; Yiding SHEN ; Jia WEI
Chinese Journal of Urology 2019;40(3):220-223
Objective To investigate the effect of replacing a smaller-size catheter after tubularized incised plate (TIP) urethroplasty on postoperative urethral complications.Methods The data of 116 hypospadias patients underwent TIP urethroplasty performed by the same urologist in our hospital from January 2014 to December 2017 were retrospectively analyzed.The age of patients ranged from 0.5-15.4 years,with the median age of 1.5 years.Meatal location was distal in 47 (39.5%),midshaft in 62 (52.1%) and proximal in 10(8.4%) patients.Unhealthy urethral plate occurred in 49 (42.2%) patients.F8 catheter was used for urethroplasty in 92 (79.3 %) patients,F10 in 17 (14.7%),and F12 in 7 (6.0%).According to the pattern of urinary diversion,patients were divided into two groups.Conventional catheter group in 56 patients (group A):the catheter was chosen in as large size as possible for urethroplasty without tension.Replace a smaller-size catheter group in 60 patients (group B):replace a smaller-size catheter after urethroplasty on the basis of group A.There were no statistically significant differences in age,meatal location and catheter size between the two groups (P > 0.05).Results The mean follow up was 23 months (range 6-66 months).There were 73(62.9%) cases of orifice overflow during indwelling catheterization.There were 5 (4.3%) patients needed further reoperation result from postoperative urethral complications,including 4 cases of fistula and 1 case of meatal stenosis.The process of replacing a smaller-size catheter after urethroplasty in group B was simple and without adverse reactions.There were 15 (26.8%) cases of orifice overflow in group A and 58 (96.7%) in group B.There were statistically significant differences in orifice overflow between the two groups (P < 0.05).There were 5 (8.9%) cases of postoperative urethral complications in group A and 0 case in group B.There were statistically significant differences in postoperative urethral complications (P < 0.05).Conclusions The process of replacing a smaller-size catheter after TIP urethroplasty in was simple and subsequently contributed to less postoperative urethral complications.The results of replacing a smaller-size catheter after TIP urethroplasty were superior to that of no replacing conventionally.
5.The application of pedicled tunica vaginalis flap cover new urethra in redo and second-stage hypospadias repair
Yiding SHEN ; Shan XU ; Daxing TANG ; Guangjie CHEN ; Lingfeng ZHU ; Fan YANG ; Wei RU ; Xiaohao WANG ; Xueping WANG
Chinese Journal of Urology 2018;39(2):126-129
Objective To investigate the application of pedicled tunica vaginalis flap cover new urethra in redo and second-stage hypospadias repair.Methods Retrospective analysis was performed in 45 redo hypospadias repair cases,aged from 1 year 3 months to 9 years 4 months (median 5 years 3month).All patients were divided into urethral dehiscence after hypospadias repair (group A) and the second stage surgery of two-stage hypospadias repair (group B) based on medical history.According to the site of dehiscence,the group A were further divided into midshaft urethral dehiscence (A1) and glans and distal urethral dehiscence with urethral opening located on midshaft (A2).After new urethra was completed,the appropriate size of the pedicledtunica vaginalis flap was transferred to cover the new urethra.Results There was no scrotal hematoma occurred in all 45 cases,and somecomplications occurred,including scrotal swelling in 1 case,high-riding testicle in 2 cases,penile clockwise torsion in 1 case,urethrocutaneous fistula in 6 cases.All the 45 cases were followed up for 1 to 4 years,with mean of 1.8 years.One more urethrocutaneous fistula occurred in group A2 and 1 more urethrocutaneous fistula with urethral stricture occurred in group B.There was no penile curvature and urethral diverticulum occurred in all cases.Conclusions Pedicled tunica vaginalis flap could be used as waterproofing layer to cover new urethra in redo hypospadias repair and presented a low incidence rate of postoperative complications.
6.Accuracy of portable hemoglobinometer in maintenance hemodialysis patients
Xiaohao ZHANG ; Fanglin TANG ; Jialing RAO ; Yuanqing LI ; Wei LI ; Cailian CHENG ; Hui PENG
Chinese Journal of Nephrology 2024;40(1):49-52
This study aims to evaluate the accuracy of portable hemoglobinometer (Hemocue Hb 201+ hemoglobin analyzer) in patients with maintenance hemodialysis (MHD) and its diagnostic value for anemia. The data of venous hemoglobulin (Hb) and fingertip capillary hemoglobulin (DHb) in MHD patients from Lingnan Hospital, the Third Affiliated Hospital of Sun Yat-sen University were retrospectively analyzed, and the correlation and difference between DHb and Hb and the accuracy of DHb in the diagnosis of anemia were evaluated. A total of 105 patients were included in the study. There was no significant difference between the paired DHb and Hb [(109±21) g/L vs. (108±20) g/L, t=-1.284, P=0.202]. Pearson correlation analysis showed that DHb was positively correlated with Hb ( r=0.929, P<0.001). Linear regression analysis showed that DHb and Hb met the regression equation Hb=0.88×DHb+12.23, and P<0.001. Bland-Altman analysis showed that the differences between the paired DHb and Hb was (1.0±7.8) g/L with the limit of agreement as (-14.2, 16.2) g/L. The mean percentage of the differences in Hb was 1% with limit of agreement as (-13.7%, 15.7%). A DHb of >110 g/L was 0.90 sensitive and 0.83 specific to identify patients with an Hb >110 g/L and its positive and negative predictive values were 0.84 and 0.90, respectively. It suggests that, in MHD patients, Hemocue Hb 201+ analyzer shows good accuracy, and can be used to monitor the Hb trend and serve as a screen method for those reaching target Hb.
7.Study on the radiation device of 241Am-Be neutron source and its dosimetric properties
Xiaohao TANG ; Bo HONG ; Shengnan FAN ; Lei CAO ; Changlin LAN ; Xiaodong PAN
Chinese Journal of Radiological Health 2021;30(2):168-172
Objective To design and build a set of experimental equipment for neutron radiation irradiation by using the 241Am-Be neutron source. Methods In the preliminary work, the spatial distribution data of the neutron energy spectrum and the gamma energy spectrum inside and outside the device were simulated by Monte Carlo method, and the changes of radiation fluence rate with spatial distribution was studied. The model of the 241Am-Be neutron device was established, and the neutron transport process in the irradiation field was studied using the method of shadow cone, inverse square law and other data analysis methods. Results Based on the simulation results, the normalized effective does of fast neutron fluence at the measurement point is about 72.9 pSv/n, and the one of photon fluence is about 3.04 pSv/γ. The ratio of effective dose of photon fluence to neuteon is about 4.17%. Conclusion Using Monte Carlo method, a standard model of 241Am-Be neutron source was constructed, the shadow cone design was optimized, and the feasibility of using the shadow cone conversion method to establish a standard neutron source radiation device was discussed.