1.Expression of neurotrophins receptor p75NTR in human breast cancer resistant cell line and its correlation with multidrug resistance
Xiaofang DENG ; Gang XU ; Lizhen HE
The Journal of Practical Medicine 2017;33(9):1389-1393
Objective To investigate the expression of neurotrophins receptor 75NTR in human breast cancer resistant cell line and its correlation with multidrug resistance. Methods Western blot was used to detect the expression level of p75NTR protein in various breast cancer cell lines and multidrug resistant cell lines. The over-expression vector and siRNA vector of p75NTR were constructed by gene recombination method. Western blot was used to detect the expression levels of p75NTR protein in transfected p75NTR and p75NTR - siRNA breast cancer resistant cell line MDA-MB-231/ADR;the sensitivity of MDA-MB-231 and MDA-MB-231/ADR to different chemotherapeutic anticancer drug (PTX ,ADM ,GEM ,DDP ,OXA) and the multi-drug resistance effects in over-expression and knock-down p75NTR MDA-MB-231/ADR were detected by CCK-8 assay. Results Western blot result showed that the expressions of p75NTR protein in the multidrug-resistant breast cancer cell lines MDA-MB-231/ADR and MCF-7/5-FU were higher than that of other breast cancer cell lines. Over-expression of p75NTRcan up-regulate the expression of p75NTR protein in MDA-MB-231/ADR;the CCK-8 assay indicated that over-expression of p75NTR can effectively enhance the resistance of MDA-MB-231/ADR cells to ADM,GEM and OXA. Conclusion The expression of p75NTR in breast cancer resistant cell line is higher than that of its parental cell line;over-expression of p75NTR can reduce the sensitivity to chemotherapeutic drugs and promote its multidrug resistance.
2.Evaluation of the role of contrast enhanced ultrasound in treatment of ultrasound guided high intensity focused ultrasound ablation for uterine fibroids
Li LIN ; Xiaofang LIU ; Jia HE
Chongqing Medicine 2014;(33):4469-4471
Objective To evaluate the role of contrast enhanced ultrasound in treatment of ultrasound guided high intensity fo‐cused ultrasound ablation for uterine fibroids .Methods Forty eight women with uterine fibroids were allocated into contrast en‐hanced group(25cases ,42fibroids) and non contrast enhanced group(23 cases ,35 fibroids) .The average volume of fibroids and the non perfused volume and the fractional ablation and adverse effects between the tow groups were compared .Results Non perfused volume was observed in all fibroids of the two groups after high intensity focused ultrasound ablation through sulphur hexafluoride micro bubbles .The average non perfused volume was 19 .5(18 .2)cm3 and 22 .5(14 .5)cm3 ,fractional ablation was (78 ± 18)% and (87 ± 13)% of the uterus immediately after HIFU respectively .The average non perfused volume was 18 .6(18 .2)cm3 and 19 .5 (18 .7)cm3 ,fractional ablation was (85 .7 ± 15 .2)% and (87 .6 ± 8 .0)% of the uterus two days after HIFU .There was no signifi‐cant difference was observed in average non perfused volume and the fractional ablation between the two groups(P>0 .05) .During HIFU procedure ,more patients in non contrast enhanced group complained sacral pain than those in contrast enhanced group(P<0 .05) .Conclusion Contrast enhanced ultrasound is an accurate method in assessing the treatment effect of HIFU and could be safely used during HIFU treatment for uterine fibroids ,shorten therapy time ,and decrease side reaction .
3.Long term follow-up of high intensity focused ultrasound in the treatment of uterine fibroids with diameter less than 4 cm
Lili WAN ; Xiaofang LIU ; Jia HE
Chongqing Medicine 2015;(31):4389-4391,4395
Objective To investigate the safety and effectiveness of high intensity focused ultrasound (HIFU ) in the treat‐ment of uterine fibroid (<4 cm) .Methods Retrospectively studied 79 single fibroid (<4 cm) patients that treated with HIFU in our hospital from January 2011 to February 2013 .Evaluated the improvement of post‐treatment ,shrinkage of fibroid volume and HIFU‐related adverse reaction .Results All the 79 patients were successfully cured by HIFU treatment .The shrinkage rate of fi‐broid was 79 .0% (four point spacing 57 .9% ,92 .1% ) after 2‐year treatment ;Symptom severity score (SSS) and uterine fibroid symptom and quality of life score (UFS‐QOL) were significantly improved ;and there was no adverse reaction .Conclusion HIFU can be safely used in the treatment of small uterine fibroids (diameter<4 cm ) .
4.Preliminary construction of the evaluation index system for the safety quality of cardiovascular medicine
Yan WU ; Xiaofang HE ; Li YOU
Modern Clinical Nursing 2017;16(6):65-71
Objective To establish an evaluation index system for the quality and safety of the specialized nursing care in cardiovascular medicine. Methods To screen and evaluate the safety quality evaluation index via a group discussion with Delphi method and analytic hierarchy process referenced to the literatures from the evaluation index of domestic nursing safety quality (NSQ)and on the base ofthe factor quality- quality of links-final quality3-dimensional quality structure theory by Donabedian. Results The first and second round of expert consultation and the recovery rate were 97.05% (33/34) and 94.12% (32/34) respectibely, the effective rate was 100%;The authoritative coefficient of expert of the safety quality evaluation index of the specialized nursing care is 0.867 and 0.879 respectively. In the first round, the average of the importance rating is 3.50-5.00, the standard deviation is 0-0.042 and full mark rate is 34.10%-100%. In the second round, the average of the importance rating is 3.80-4.70, the standard deviation is 0~0.047 and full mark rate is 31.60%-100%. The fluctuation degree of the first round is more than 0.10 with a low coordination degree. However, the fluctuation degree of the second round result is less than 0.10. The coordination coefficients from all qustionnair scores by experts in the two roudns are 0.169 and 0.286. The difference was statistically significant according to the chi-square analysis (X2=6.842, P=0.002). The NSQ evaluatin index included 3 first degree indexes (weight coefficient including 0.2684,link qualing 0.6144,and quality 0.1172),16 second degree indicators (weight coefficient 0.034~0.0859) and 61 third degree indexes ( weight coefficient 0.034~0.0859) and 61 third degree indexes (weight coefficient 0.0052~0.0412). Conclusions This paper preliminary established a specialied NSQ evaluation index with factor quality- quality of links-final quality 3-dimensional quality structure in the field of cardiovascular medicine, which is based on Delphi method and analytic hierarchy process. NSQ provides a measurement tool for nurses in CME.
5.Research on the range of motion measurement system for spine based on LabVIEW image processing technology.
Xiaofang LI ; Linhong DENG ; Hu LU ; Bin HE
Journal of Biomedical Engineering 2014;31(4):767-770
A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.
Biomechanical Phenomena
;
Cadaver
;
Humans
;
Image Processing, Computer-Assisted
;
Range of Motion, Articular
;
Spine
;
physiology
6.Clinical analysis of laparoscopic sungery treatment of tubal obstruction infertility combined with endometriosis
Yao ZHANG ; Changqing PAN ; Xiaofang SHU ; Wei HE ; Lisa HUANG
Clinical Medicine of China 2011;27(11):1222-1224
Objective To investigate the diagnosis and treatment value of laparoscopic surgery in tubal obstruction infertility patients with endometriosis.Methods Retrospective analysis was done in 381 cases underwent laparoscopic treatment for tubal obstruction from May 2005 to May 2010,,of which 119 cases were combined with endometriosis.The treatment results were analyzed,including the decomposition of the umbrella side tubal obstruction adhesions,lesions of endometriosis electrocoagulation,endometriosis cystectomy and pregnancy and so on.Results Hysterosalpingography(HSG)showed tubal occlusion in both side or one side in the distal end in 381 cases,and these patients were treated with laparoscopic surgery.There were 262 cases showed distal tubal occlusion not companied with endometriosis,of which 82 cases clinically pregnanced,accounting for 31.3%.Surgical treatment of endometriosis found in 119 cases,accounting for 31.2% ; and 29 cases pregnaced,which accounted 24.4%.We found 42 cases of tubal adhesions grade Ⅰ-Ⅱ and endometriosis stage Ⅰ-Ⅱ,16 cases of clinical pregnancy,accounting for 38.1% ;Twenty-six cases of tubal adhesions grade Ⅰ-Ⅱ and endometriosis stage Ⅰ-Ⅱ,7 cases of clinical pregnancy,accounting for 26.9% ;Twenty-eitht cases of tubal adhesions grade Ⅲ-Ⅳ and endometriosis stage Ⅰ-Ⅱ,4 cases of clinical pregnancy,accounting for 14.3% ;Twenty-three cases of tubal adhesions grade Ⅲ-Ⅳ and endometriosis stage Ⅲ-Ⅳ,2 cases of clinical pregnancy,accounting for 8.7%.The clinical pregnancy rate in the first group was significantly higher than the other groups,chnical pregnancy rate of the last group was the lowest.Conclusion Laparoscopic surgery is an effective treatment of tubal obstruction infertility combined with endometriosis.After laparoscopic surgery,the clinical pregnancy rate is significantly higher in Tubal obstruction without endometriosis than patients with endometriosis.After surgery,the clinical pregnancy rate in patients with the light stage tubal adhesions and endometriosis is better than those severely.
7.Expression and clinical significance of Topo Ⅱα , COX-2 in breast cancer tissues
Gang XU ; Zhongfu SHAO ; Xiaofang DENG ; Lizhen HE
Cancer Research and Clinic 2011;23(2):100-102
Objective To explore the expression of Topo Ⅱα and COX-2 in breast cancer tissues and investigate their correlations to clinicopathologic feature of breast cancer. MethodsThe expression of Topo Ⅱα and COX-2 in 50 specimens of breast cancer and their normal tissues were detected by immunohistochemistry. Their correlation to clinicopathologic features of breast cancer were analyzed.ResultsThe positive rates of Topo Ⅱα were 64 % (32/50) and 22 % (11/50) and COX-2 were 68 % (34/50) , 14 %(7/50) in breast cancer and normal tissue (P<0.05). The expression of Topo Ⅱα was correlated to degree of differentiation (P <0.05), not correlated to patient age, tumor size, clinical stage and lymph node metastasis(P >0.05). The expression of COX-2 was correlated to tumor size, degree of differentiation, clinical stage and lymph node metastasis (P <0.05), not correlated to patient age (P >0.05). Conclusion Topo Ⅱα and COX-2 expression can be used as an indicator for predicting the differentiation, infiltration and metastasis characteristics of breast cancer.
9.Reflections on the Cell Membrane Chromatography Used in Quality Control of Traditional Chinese Medicine
Xiaofang HOU ; Sicen WANG ; Tao ZHANG ; Langchong HE
World Science and Technology-Modernization of Traditional Chinese Medicine 2014;(3):526-528
It is very difficult to comprehensively achieve the quality control of traditional Chinese medicine (TCM), because some problems such as indicator simplification and lack of correlation between efficacy and indicator are ex-isted in the common quality control of TCM. Combined with the practical experience of our research work, this paper outlined the characteristics and applications of cell membrane chromatography (CMC) and discussed that CMC method can be used for quality control of TCM.
10.Study on stability of dipstick dye immunoassay kit forschistosomiasis diagnosis
Wei HE ; Yinchang ZHU ; Guoqun CAO ; Xiaofang XIN
Chinese Journal of Schistosomiasis Control 1989;0(04):-
Objective To evaluate the stability of dipstick dye immunoassay (DDIA) kit forschisitosomiasis diagnosis. Methods By means of detection of the sera from infected people withSchistosoma japonicum and healthy people, the stability of the DDIA kit, which stored at 37℃,room temperature or 4 ℃ respectively, was evaluated depending on the detective results ofsensitivity, specificity, detectable minimum and coefficient variation ( CV). Results Thesensitivity, specificity, detectable minimum and coefficient variation of the DDIA kit were invariableafter the kits stored at 37 ℃ for 180 days, and at room temperature or 4 ℃ for 360 days.Conclusion The DDIA kit is stable while it stores at 37℃ for 180 days, and at room temperatureor 4℃ for 360 days at least.