1.Biomechanical properties of a novel automatic anti-rotation posterior atlantoaxial internal fixation system: a finite element analysis
Min YANG ; Xiangyang MA ; Jincheng YANG ; Shujin CHEN ; Xiaobao ZOU
Chinese Journal of Tissue Engineering Research 2017;21(19):3031-3037
BACKGROUND: Atlantoaxial posterior approach is currently the main surgical treatment for atlantoaxial instability and/or dislocation, but the shape of rod in normal screw-rod device system is cylindrical. To obtain satisfactory reduction of atlantoaxis, the rod will be pre-bent obviously before fixation; however, the cylindrical rod will be rotated when tighten the nuts. Extra devices will be required to adjust and maintain the direction of the rod, thereafter, the surgical field will be blocked by the device, and spinal injury will occur once the devices are not held tightly. While the novel automatic anti-rotation rod has the function of anti-rotation during nut-tightening process, and also holds all the advantages of normal rod. Further research should be performed for the differences in biomechanical characteristics between two methods.OBJECTIVE: To investigate the biomechanical properties of the novel automatic anti-rotation rod for internal fixation system of atlantoaxial posterior approach based on three-dimensional finite-analysis model of upper cervical spine.METHODS: The three-dimensional finite element model of upper cervical spine with internal rod fixation system was developed. The biomechanical characteristics of the internal fixation system were analyzed. RESULTS AND CONCLUSION: The traditional and novel three-dimensional finite element model with realistic and geometric similarity contained 198330 elements, 964747 nodes and 246788 elements, 996069 nodes,correspondingly. There was no obvious stress concentration in both two systems, stress was concentrated mainly in the screw-bone and screw-rod interfaces. The stress values of the novel system were higher than those of the traditional system, but the maximum Von Misses Stress of two systems was lower than the yield (795-827 MPa ) and ultimate (860-896 MPa) strength of titanium alloys. These results show that the design of the novel automatic anti-rotation rod-screw fixation system has matched the biomechanical requirements for new internal fixation instruments, and is one safe, effective and practical device for atlantoaxial posterior procedure showing promising application prospect.
2.Experimental study on effect of immune response mediated by ICOS signal in renal fibrosis of SHR
Xiaobao QIAN ; Yu WANG ; Renbiao MEI ; Wenjie ZHANG ; Jie MA ; Xiaoyu WANG
Chinese Journal of Immunology 2015;31(12):1610-1615
Objective:To preliminarily study the immune response mediated by inducible costimulation molecule in the role of essential hypertensive renal damage .Methods: The blood pressure of spontaneously hypertensive rats and the wild control group (Wistar-Kyoto rats)was dynamically monitored by noninvasive tail artery blood pressure measuring instrument .The urine protein of the rats in 24 hours was dynamically detected by ELISA .The levels of ICOS protein and its mRNA in the rat′s kidneys were dynamically detected by immunohistochemistry , RT-PCR, respectively.The levels of IL-17A and TGF-β1 in the rat′s plasma and kidneys were dynamically detected by ELISA ,immunohistochemistry ,respectively.The renal pathological changes of the rats were detected by HE and MASSON staining.Results:The blood pressure and urine protein in 24 h of SHRs were significantly higher than that of group WKY from 6 weeks.The expression of ICOS protein and its mRNA in SHRs were significantly higher than that of WKY rats from 6 weeks,and there are significantly positive correlations between the dynamic change of ICOS protein and its mRNA and renal fibrosis score of SHRs (rA=0.813,PA<0.05;rB=0.753,PB<0.05).The expression of IL-17A and TGF-β1 in SHR′s plasma and kidneys were significantly higher than that of WKY rats at the weeks 10 and 23.HE and Masson staining showed that the degree of renal fibrosis of SHRs was sig-nificantly higher than that of WKY rats at 23 weeks.Conclusion:The immune response mediated by ICOS plays an important role in hypertensive renal damage .
3.Cloning of the antibacterial peptide cecropin gene of Musca domestica larvae and its fusion expression in Escherichia coli
Jianhua XU ; Jiayong ZHU ; Xiaobao JIN ; Qinying XU ; Leishan LIU ; Yan MA ; Yan WANG
Chinese Journal of Zoonoses 2007;(4):311-318
In the present study, the total RNA was extracted from three instar larvae of Musca domestica, the cDNA sequence encoding the ORF of cecropins was amplified by RT-PCR, and the target fragment was further sequenced after being cloned into T vector pUCm-T. Then, the cDNA sequence of the mature cecropins was amplified by PCR with recombinant plasmid pUCm-T/cecropin as template, the N-terminal rare codon GGA of E. coli was changed to the favorable codon GGC,and a Asn codon AAC was added in front of the stop coden TAA in the C- terminus. This mutant gene designated as mCecropin was then ligated with the fusion expression vector pGEX-4T-1. After restriction analysis and DNA sequencing, the positive recombinant plasmid pGEX-4T-1/mCecropin was transformed to different strains of E. coli cells and the fusion protein was expressed after IPTG induction. The fusion protein was assayed by SDS-PAGE and the E. coli BL21(DE3) cell was chosen as the host cell for the expression of the fusion protein. The expressed fusion protein GST-mCecropin was purified by GSTrap affinity coloum and the GST marker was then cleaved by thrombin. In this way, the fusion protein mCecropin with antibacterial activity was obtained after purification with HiTrap benzamidine column.
4.Comparison of Transoral Anterior Jefferson-Fracture Reduction Plate and Posterior Screw-Rod Fixation in C1-Ring Osteosynthesis for Unstable Atlas Fractures
Mandi CAI ; Yifeng WU ; Rencai MA ; Junlin CHEN ; Zexing CHEN ; Chenfu DENG ; Xinzhao HUANG ; Xiangyang MA ; Xiaobao ZOU
Neurospine 2024;21(2):544-554
Objective:
To compare the clinical outcomes of transoral anterior Jefferson-fracture reduction plate (JeRP) and posterior screw rod (PSR) surgery for unstable atlas fractures via C1-ring osteosynthesis.
Methods:
From June 2009 to June 2022, 49 consecutive patients with unstable atlas fractures were treated by transoral anterior JeRP fixation (JeRP group) or PSR fixation (PSR group) and followed up at General Hospital of Southern Theatre Command of PLA; 30 males and 19 females were included. The visual analogue scale (VAS) score, Neck Disability Index (NDI), distance to anterior arch fracture (DAAF), distance to posterior arch fracture (DPAF), lateral mass displacement (LMD), Redlund-Johnell value, postoperative complications, and fracture healing rate were retrospectively collected and statistically analyzed.
Results:
Compared with that in the PSR group, the bleeding volume in the JeRP group was lower, and the length of hospital stay was longer. The VAS scores and NDIs of both groups were significantly improved after surgery. The postoperative DAAF and DPAF were significantly smaller after surgery in both groups. Compared with the significantly shorter DPAF in the PSR group, the JeRP group had a smaller DAAF, shorter LMDs and larger Redlund-Johnell value postoperatively and at the final follow-up. The fracture healing rate at 3 months after surgery was significantly greater in the JeRP group (p < 0.05).
Conclusion
Both C1-ring osteosynthesis procedures for treating unstable atlas fractures yield satisfactory clinical outcomes. Transoral anterior JeRP fixation is more effective than PSR fixation for holistic fracture reduction and short-term fracture healing, but the hospital stay is longer.
5.Comparison of Transoral Anterior Jefferson-Fracture Reduction Plate and Posterior Screw-Rod Fixation in C1-Ring Osteosynthesis for Unstable Atlas Fractures
Mandi CAI ; Yifeng WU ; Rencai MA ; Junlin CHEN ; Zexing CHEN ; Chenfu DENG ; Xinzhao HUANG ; Xiangyang MA ; Xiaobao ZOU
Neurospine 2024;21(2):544-554
Objective:
To compare the clinical outcomes of transoral anterior Jefferson-fracture reduction plate (JeRP) and posterior screw rod (PSR) surgery for unstable atlas fractures via C1-ring osteosynthesis.
Methods:
From June 2009 to June 2022, 49 consecutive patients with unstable atlas fractures were treated by transoral anterior JeRP fixation (JeRP group) or PSR fixation (PSR group) and followed up at General Hospital of Southern Theatre Command of PLA; 30 males and 19 females were included. The visual analogue scale (VAS) score, Neck Disability Index (NDI), distance to anterior arch fracture (DAAF), distance to posterior arch fracture (DPAF), lateral mass displacement (LMD), Redlund-Johnell value, postoperative complications, and fracture healing rate were retrospectively collected and statistically analyzed.
Results:
Compared with that in the PSR group, the bleeding volume in the JeRP group was lower, and the length of hospital stay was longer. The VAS scores and NDIs of both groups were significantly improved after surgery. The postoperative DAAF and DPAF were significantly smaller after surgery in both groups. Compared with the significantly shorter DPAF in the PSR group, the JeRP group had a smaller DAAF, shorter LMDs and larger Redlund-Johnell value postoperatively and at the final follow-up. The fracture healing rate at 3 months after surgery was significantly greater in the JeRP group (p < 0.05).
Conclusion
Both C1-ring osteosynthesis procedures for treating unstable atlas fractures yield satisfactory clinical outcomes. Transoral anterior JeRP fixation is more effective than PSR fixation for holistic fracture reduction and short-term fracture healing, but the hospital stay is longer.
6.Comparison of Transoral Anterior Jefferson-Fracture Reduction Plate and Posterior Screw-Rod Fixation in C1-Ring Osteosynthesis for Unstable Atlas Fractures
Mandi CAI ; Yifeng WU ; Rencai MA ; Junlin CHEN ; Zexing CHEN ; Chenfu DENG ; Xinzhao HUANG ; Xiangyang MA ; Xiaobao ZOU
Neurospine 2024;21(2):544-554
Objective:
To compare the clinical outcomes of transoral anterior Jefferson-fracture reduction plate (JeRP) and posterior screw rod (PSR) surgery for unstable atlas fractures via C1-ring osteosynthesis.
Methods:
From June 2009 to June 2022, 49 consecutive patients with unstable atlas fractures were treated by transoral anterior JeRP fixation (JeRP group) or PSR fixation (PSR group) and followed up at General Hospital of Southern Theatre Command of PLA; 30 males and 19 females were included. The visual analogue scale (VAS) score, Neck Disability Index (NDI), distance to anterior arch fracture (DAAF), distance to posterior arch fracture (DPAF), lateral mass displacement (LMD), Redlund-Johnell value, postoperative complications, and fracture healing rate were retrospectively collected and statistically analyzed.
Results:
Compared with that in the PSR group, the bleeding volume in the JeRP group was lower, and the length of hospital stay was longer. The VAS scores and NDIs of both groups were significantly improved after surgery. The postoperative DAAF and DPAF were significantly smaller after surgery in both groups. Compared with the significantly shorter DPAF in the PSR group, the JeRP group had a smaller DAAF, shorter LMDs and larger Redlund-Johnell value postoperatively and at the final follow-up. The fracture healing rate at 3 months after surgery was significantly greater in the JeRP group (p < 0.05).
Conclusion
Both C1-ring osteosynthesis procedures for treating unstable atlas fractures yield satisfactory clinical outcomes. Transoral anterior JeRP fixation is more effective than PSR fixation for holistic fracture reduction and short-term fracture healing, but the hospital stay is longer.
7.Comparison of Transoral Anterior Jefferson-Fracture Reduction Plate and Posterior Screw-Rod Fixation in C1-Ring Osteosynthesis for Unstable Atlas Fractures
Mandi CAI ; Yifeng WU ; Rencai MA ; Junlin CHEN ; Zexing CHEN ; Chenfu DENG ; Xinzhao HUANG ; Xiangyang MA ; Xiaobao ZOU
Neurospine 2024;21(2):544-554
Objective:
To compare the clinical outcomes of transoral anterior Jefferson-fracture reduction plate (JeRP) and posterior screw rod (PSR) surgery for unstable atlas fractures via C1-ring osteosynthesis.
Methods:
From June 2009 to June 2022, 49 consecutive patients with unstable atlas fractures were treated by transoral anterior JeRP fixation (JeRP group) or PSR fixation (PSR group) and followed up at General Hospital of Southern Theatre Command of PLA; 30 males and 19 females were included. The visual analogue scale (VAS) score, Neck Disability Index (NDI), distance to anterior arch fracture (DAAF), distance to posterior arch fracture (DPAF), lateral mass displacement (LMD), Redlund-Johnell value, postoperative complications, and fracture healing rate were retrospectively collected and statistically analyzed.
Results:
Compared with that in the PSR group, the bleeding volume in the JeRP group was lower, and the length of hospital stay was longer. The VAS scores and NDIs of both groups were significantly improved after surgery. The postoperative DAAF and DPAF were significantly smaller after surgery in both groups. Compared with the significantly shorter DPAF in the PSR group, the JeRP group had a smaller DAAF, shorter LMDs and larger Redlund-Johnell value postoperatively and at the final follow-up. The fracture healing rate at 3 months after surgery was significantly greater in the JeRP group (p < 0.05).
Conclusion
Both C1-ring osteosynthesis procedures for treating unstable atlas fractures yield satisfactory clinical outcomes. Transoral anterior JeRP fixation is more effective than PSR fixation for holistic fracture reduction and short-term fracture healing, but the hospital stay is longer.
8.Comparison of Transoral Anterior Jefferson-Fracture Reduction Plate and Posterior Screw-Rod Fixation in C1-Ring Osteosynthesis for Unstable Atlas Fractures
Mandi CAI ; Yifeng WU ; Rencai MA ; Junlin CHEN ; Zexing CHEN ; Chenfu DENG ; Xinzhao HUANG ; Xiangyang MA ; Xiaobao ZOU
Neurospine 2024;21(2):544-554
Objective:
To compare the clinical outcomes of transoral anterior Jefferson-fracture reduction plate (JeRP) and posterior screw rod (PSR) surgery for unstable atlas fractures via C1-ring osteosynthesis.
Methods:
From June 2009 to June 2022, 49 consecutive patients with unstable atlas fractures were treated by transoral anterior JeRP fixation (JeRP group) or PSR fixation (PSR group) and followed up at General Hospital of Southern Theatre Command of PLA; 30 males and 19 females were included. The visual analogue scale (VAS) score, Neck Disability Index (NDI), distance to anterior arch fracture (DAAF), distance to posterior arch fracture (DPAF), lateral mass displacement (LMD), Redlund-Johnell value, postoperative complications, and fracture healing rate were retrospectively collected and statistically analyzed.
Results:
Compared with that in the PSR group, the bleeding volume in the JeRP group was lower, and the length of hospital stay was longer. The VAS scores and NDIs of both groups were significantly improved after surgery. The postoperative DAAF and DPAF were significantly smaller after surgery in both groups. Compared with the significantly shorter DPAF in the PSR group, the JeRP group had a smaller DAAF, shorter LMDs and larger Redlund-Johnell value postoperatively and at the final follow-up. The fracture healing rate at 3 months after surgery was significantly greater in the JeRP group (p < 0.05).
Conclusion
Both C1-ring osteosynthesis procedures for treating unstable atlas fractures yield satisfactory clinical outcomes. Transoral anterior JeRP fixation is more effective than PSR fixation for holistic fracture reduction and short-term fracture healing, but the hospital stay is longer.
9.Secretion expression of BPI23-haFGF fusion gene in Pichia pastoris X-33 and identification of its biological activity.
Yan MA ; Jiayong ZHU ; Xiaobao JIN ; Haiying PENG ; Yan WANG
Journal of Biomedical Engineering 2009;26(2):379-384
The BPI23-haFGF fusion gene was subcloned to the yeast expression vector pPICZaA and the recombinant plasmid pPICZaA-BPI23-haFGF was constructed. After linearization by sac I, the construct was introduced into X-33 yeast cells. The efficient engineering strain was obtained by the resistance and phenotype selection and identified by specific PCR. SDS-PAGE and Western blot analysis indicated that a 43 KD protein band coincident with the anticipated fusion protein size expressed in the culture supernatant of the transformed yeast cells, which accounted for above 50% of the total proteins of the culture supernatant. About 90% purity of recombinant BPI23-haFGF fusion protein was obtained by affinity chromatography. The in vitro bioactivity testing showed that the purified fusion protein killed E. coli and promoted proliferation of NIH3T3 cells, suggesting that the recombinant BPI23-haFGF fusion protein possessed both of BPI and FGF functions.
Animals
;
Antimicrobial Cationic Peptides
;
genetics
;
metabolism
;
Blood Proteins
;
genetics
;
metabolism
;
Cell Proliferation
;
Cloning, Molecular
;
Escherichia coli
;
drug effects
;
Fibroblast Growth Factor 1
;
genetics
;
metabolism
;
Gene Fusion
;
Genetic Vectors
;
Humans
;
Mice
;
NIH 3T3 Cells
;
Pichia
;
genetics
;
metabolism
;
Recombinant Fusion Proteins
;
genetics
;
metabolism
;
pharmacology
10.Biomechanical analysis of new horizontal screw-screw crosslink in C1-C2 pedicle screw-rod fixation
Beiping OUYANG ; Xiangyang MA ; Chunshan LUO ; Xiaobao ZOU ; Tingsheng LU ; Qiling CHEN
Chinese Journal of Tissue Engineering Research 2024;28(12):1837-1841
BACKGROUND:Posterior atlantoaxial pedicle screw rod internal fixation is the main method for treating atlantoaxial dislocation,and the horizontal crosslink plays an important role in the antirotation ability of the internal fixation system.The new horizontal screw-screw crosslink can effectively overcome the disadvantages of traditional horizontal crosslink,such as inconvenient installation,impact on bone grafting bed,and potential spinal cord injury.However,the biomechanical properties of the new horizontal screw-screw crosslink with different installation modes are still unclear. OBJECTIVE:To investigate the biomechanical characteristics of new different installation modes of horizontal screw-screw crosslink in the C1-C2 pedicle screw-rod fixation and to provide a theoretical basis for optimal installation mode. METHODS:Six fresh human occipitocervical specimens were divided into the intact state group(group A),and the atlantoaxial instability model of type Ⅱ odontoid fracture was established based on the intact state group as the instability group(group B).The C1-C2 pedicle screw-rod fixation was performed on each specimen based on the instability group(group C).In group C,different installation modes of horizontal screw-screw crosslink were successively installed in each specimen,including upper transverse connection(two atlas screw tails)as group D,lower transverse connection(two axis screw tails)as group E,diagonal transverse connection(upper left and lower right for group F,lower left and upper right for group G),and cross transverse connection as group H.The specimen models were tested in order of flexion,extension,lateral flexion and lateral rotation on a three-dimensional motion machine,and the atlantoaxial range of motion of each group of specimens was obtained.Repeated measure analysis of variance was used to evaluate the biomechanical properties of each group. RESULTS AND CONCLUSION:(1)Under six states,the range of motion of groups A,C,D,E,F,G and H was smaller than that of group B,and there were statistically significant differences(P<0.05).(2)In the flexion and extension states,there was no significant difference among the five types of horizontal screw-screw crosslink groups(P>0.05).(3)In the left and right rotation directions,there were significant differences in D and E groups compared with F,G and H groups(P<0.05);there were no significant differences between D and E groups,and F and G groups(P>0.05),and there were no significant differences in F and G groups compared with H group(P>0.05).(4)In conclusion,under flexion-extension states,the biomechanical stability of five types of horizontal screw-screw crosslink groups was similar,but under the rotation state,the stability of diagonal horizontal screw-screw crosslink group and cross horizontal screw-screw crosslink group was obviously better than that of transverse horizontal screw-screw crosslink group;however,the stability of diagonal horizontal screw-screw crosslink group is similar to the cross horizontal screw-screw crosslink group,so the former is more worthy of clinical recommendation.