1.Application of clinical risk index for babies in low birth weight preterm infants
Chinese Pediatric Emergency Medicine 2016;23(3):195-199
Clinical risk index for babies( CRIB) is applied in low birth weight preterm neonates to assess the initial severity of illness,predict mortality risk rates,evaluate their own performance,and audit the performance between different medical institutions.CRIB plays an important role in the progressive develop-ment of neonatology.The scoring rules and advantagse of CRIB scorni g system were introud ced in this arti-cle.Teh scoring system is able to correctly predict mortaliyt probabilities and long-term neurodevelopmental outcomes for low birth weight preterm infants.
2.Effects of E23K polymorphism in KCNJ11 gene on membrane current.
Xiao-Hui XIA ; Ai-Hong YANG ; Yang HU
Chinese Journal of Applied Physiology 2014;30(1):23-26
OBJECTIVEE23K polymorphism in KCNJ11 gene is associated with cardiovascular disease and diabetes. In order to explore the mechanism of E23K correlation to related diseases, the effect of E23K polymorphism in KCNJ11 gene on membrane current was investigated.
METHODSThe exon of KCNJ11 was obtained by PCR amplification and the G-->A mutation was completed by overlap extension PCR. The sequences of KCNJ11 exon contained 23E or 23K was inserted into pcDNA3.1/CT-GFP vector respectively. The recombinant plasmid, pcDNA3.1-KCNJ11(E) and pcDNA3.1-KCNJ11(K), were transfected into HEK293T cells by lipofectamine and the membrane current density was determined by whole-cell patch clamp technique.
RESULTS1,173 bp sequences of KCNJ11 gene's exon were amplified by PCR and the recombinant expression plasmid, pcDNA3.1-KCNJ11(E) and pcDNA3.1-KCNJ11(K), were constructed successful. Positive and negative currents were detected in HEK293T cells transfected with difference plasmid by whole-cell patch clamp technique. Results showed that the reversed voltage was 50mV. The current in HEK293T cells with pcDNA3.1-KCNJ11(E) was significantly greater than that with pcDNA3.1-KCNJ11(K) (P < 0.05, n = 10).
CONCLUSIONThe polymorphism of E23K in exon of KCNJ11 gene changed the membrane currents in HEK293T cells. It could be an experiment support for the possible mechanism between the locus and related diseases.
Exons ; HEK293 Cells ; Humans ; Membrane Potentials ; Patch-Clamp Techniques ; Polymorphism, Genetic ; Potassium Channels, Inwardly Rectifying ; genetics
4.Duration for silicon gastric tube to indwell in stomach of elderly patients
Xia LV ; Hongying HU ; Muying CHEN ; Zhen WANG ; Qiumei XIAO
Modern Clinical Nursing 2013;(11):29-31
Objective To investigate the duration for silicon gastric tube to indwell in stomach of aged patients.Methods One hundred elderly patients needing long-term nutrition support were equally randomized into two groups: control group and observation group.The former had the gastric tubes indwelled in the stomach for 4 weeks and the latter for 3 weeks.The two groups were compared about the used tubes in terms of the color of tube at the length of the first 10cm,the indentation by reflection for 10 seconds at the tube of first 10 cm,the hardness of the tube at the length of the first 10 cm and the springback angle of tube at the first 10cm after reflection.Results The tubes in the observation group were significantly better than those in the control group in terms of color,indentation,hardness and springback angle(all P<0?01).Conclusion The duration of indwelling silicon gastric tubes in stomach can be three weeks for old patients needing long-term nutrition support via indwelling silicon tubes in their stomach.
5.Studies on association of HSL repeat polymorphism and aerobic endurance.
Xiao-hui XIA ; Hui-yun XIA ; Jie GUO ; Kang-chao LIU ; Yang HU
Chinese Journal of Applied Physiology 2015;31(1):93-96
OBJECTIVETo investigate the relationship between hormone sensitive lipase (HSL) gene polymorphism and aerobic endurance.
METHODSThe (CA)n repeats polymorphism genotypes in HSL intro 6 of 123 outstanding long distance runners and 127 controls of Han nationality in northern China were analyzed by PCR and Fluorescence labeled STR-genescan. Repeat polymorphisms were grouped according to segmentation point and alleles were divided into long or short chains. Chi-square test was used to analyze the frequency difference of allelic and genotypic between athlete and control groups.
RESULTS(CA) n repeats polymorphism in HSL gene was total of 9 different repeat number of alleles, which composed of 25 different genotypes. The chi-square test result showed that when compared short and long chain alleles split by 4, there was a significant difference (P <0.05) of genotype distribution in 5/10 km group compared with control. Compared the rest groups with control, there was no significant difference.
CONCLUSIONCompared short and long chain alleles split by 4, the LL genotype of (CA)n of HSL was associated with aerobic endurance and it might be a molecular marker of elite 5/10 km long distance runners.
Alleles ; China ; Ethnic Groups ; Genotype ; Humans ; Physical Endurance ; Polymerase Chain Reaction ; Polymorphism, Genetic ; Sterol Esterase ; genetics
6.Influence of different image processing methods on mensuration of cardiac function in myocardial perfusion imaging
Fan HU ; Xiaotian XIA ; Xiao ZHANG ; Xiaoli LAN ; Jia HU ; Yongxue ZHANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2017;37(9):564-567
Objective To evaluate the influences of FBP and OSEM (with different iteration numbers or subset numbers) on cardiac function parameters with MPI,and to identify a suitable clinical method.Methods The MPI of 66 patients (33 males,33 females,age range: 18-77 years) from January 2012 to December 2014 were retrospectively analyzed.The imaging data was reconstructed with FBP and 5 different OSEM (4-16 subsets and 2-4 iterations) in order to evaluate if there was any difference of cardiac function parameters calculated by QGS between the different image processing methods.In addition,the results were compared with those of cardiac ultrasonography.One-way analysis of variance was used for data analysis.Results The statistical differences of LVEF,EDV,and ESV(F values: 10.73,4.89 and 5.97,all P<0.05) were found among 6 reconstructed methods.The values of LVEF were (66.14±11.12)%,(75.05±12.10)%,(70.09±11.27)%,(66.88±10.38)%,(64.97±10.25)%,and (62.58±9.84)%.Those of EDV were (77.32±27.58),(67.97±27.56),(75.10±27.89),(81.03±28.11),(84.94±29.07),and (89.98±29.71) ml,and the ESV values were (28.71±10.04),(19.71±16.51),(25.13±17.66),(29.01±18.47),(32.10±19.63),and (35.83±20.41) ml respectively.The cardiac function parameters measured by OSEM (with 2 iterations,12 subsets) were much similar to that measured by cardiac ultrasonography.Conclusion Compared with other 5 processing methods of MPI,the OSEM (with 2 iterations,12 subsets) method may be more suitable for practical clinical application.
7.Simultaneous Determination of Seven Anions and Organic Acids in Huo-Xue Tong-Luo Injection by HPCE
Xia LIN ; Junhua HU ; Peichao CUI ; Jiachun LI ; Yuan BI ; Zhenzhong WANG ; Wei XIAO
World Science and Technology-Modernization of Traditional Chinese Medicine 2014;(11):2506-2511
This study was aimed to establish a method for simultaneous determination of seven anions and organic acids in Huo-Xue Tong-Luo (HXTL) injection by HPCE. With tartaric acid as the internal standard, separation was performed on an uncoated fused silica capillary (50 μm × 64. 5 cm, 56 cm of effective length). The 14 mmol·L-1 potassium acid phthalate and 0.1 mmol·L-1 hexadecyl trimethyl ammonium chloride were selected for the running buffer solution (pH 5.6). The separation voltage was -16 kV. The detection wavelength was set at 210 nm. The column temperature was maintained at 25 ℃ . The sample was injected at 50 mbar×4 s. The results showed that
calibration curves of chloride ion, sulfuric acid root ion, formate ions, malic acid, succinic acid, iodate ion and acetic acid ions showed good linear relationship 41.4-248.2 μg·mL-1 (r = 0.999 3), 12.5-74.8 μg·mL-1 (r = 0.999 8), 18.2-109.1 μg·mL-1 (r = 0.999 8), 20.3-121.6 μg·mL-1 (r = 0.999 5), 17.2-103.1 μg·mL-1 (r=0.999 1), 17.6-105.6μg·mL-1 (r=0.999 6), 51.6-309.6μg·mL-1 (r=0.999 7), respectively. The average recoveries were 102.6%, 97.3%, 102.2%, 99.0%, 99.2%, 97.8%, and 103.4%, respectively. The RSD were 1.7%, 2.0%, 1.6%, 2.6%, 2.1%, 2.9%, and 1.0%, respectively (n = 6). It was concluded that the method was accurate and reproducible. It was suitable for the determination of anions and organic acids in HXTL injection.
8.Tomographic characteristics of optic nerve head on Heidelberg retina tomograph Ⅲ in healthy Chinese subjects
Bin, LIU ; Ming-guang, HE ; Sheng-song, HUANG ; Qiu-xia, YIN ; Xiao-hu, DING
Chinese Journal of Experimental Ophthalmology 2013;(7):664-667
Background Normal adult optic disc rim width follows inferior ≥ superior ≥ nasal ≥ temporal (ISNT) rule.Analysis of the optic disc structural parameters with Heidelberg retina tomograph (HRT) can understand whether ISNT principle is suitable to other optic disc structure parameters.Objective This study was to investigate the characteristics of optic nerve head structure parameters in normal Chinese adults.Methods The parents of twins who participated Guangzhou Twin Eye Study were enrolled in Zhongshan Ophthalmic Center from 2006 June to 2011 August.All subjects received the routine eye examinations,including visual acuity,slit lamp microscope,direct ophthalmoscope examination,auto-refraction examination and HRT Ⅲ examination.All data from the right eyes were collected and analyzed.HRT values from different quadrants of optical nerve head were compared with one-way analysis of variance,and the multiple comparison between quadrants was carried out by Bonferroni test.The differences of optical nerve head parameters in different gender were analyzed using independent sample t test and Bland-Altman test.Results In this study,1672 eyes of 1672 subjects were included,with the 759 male and 913 female persons and average age of (41.8±5.3)years.No significant differences were seen in the disc area (DA)between the superior and inferior,as well as the nasal and temporal quadrants among the subjects (P>0.05).In addition,there were not significantly different in the rim area (RA) between the superior and nasal disc as well as the rim volume (RV) among the inferior,superior and nasal disc (P>O.05).However,significant differences were found in the cup area (CA),cup/disk area ratio (C/DAR),cup volume (CV),mean cupdepth (MCD),maximum cup depth (MxCD),height variation contour (HVC),cup shape measure (CSM),mean retinal nerve fiber layer thickness (mRNFLT) and retinal nerve fiber layer cross section area (RNFLcsa) among the different quadrants (P<0.001).The local differences from only DA and RA complied with an ordination of the ISNT rule.The values of DA,CA,C/DAR,CV,MCD,MxCD from male individuals were higher,but those of the RV,HVC,mRNFLT RNFLcsa were lower in comparison with female individuals.Nevertheless,all the differences were < 0.1 with a maximal mean difference in DA and CA (both 0.07 mm2).Conclusions The optical nerve head configurations measured by HRT have different distributing characteristics in four quadrants in normal adults.Most parameters show the higher values in the inferior and superior than those in nasal and temporal of disc,but DA and RA meet ISNT rule.The differences of most parameters between male and female subjects can be ignored.
9.The impact of refractive errors and axial length on the structural parameters of the optic disc
Bin, LIU ; Ming-guang, HE ; Sheng-song, HUANG ; Qiu-xia, YIN ; Xiao-hu, DING
Chinese Journal of Experimental Ophthalmology 2013;31(10):953-957
Background Heidelberg Retinal Tomograph (HRT) has been widely used in clinical diagnosis of glaucomatous optic neuropathy,importantly,the measurement results of HRT may be affected by myopia.Therefore,studying the effect of different refractive status and axial length on structural parameters of the optic disc is important.Objective This study was to evaluate the influence of refractive error and axial length to optic nerve head parameter measured by HRT.Methods The parents who participate in Guangzhou Twin Study were enrolled in this investigation from July 2006 to August 2011.The regular eye examinations,including visual acuity,slit lamp,fundus,auto-refraction,HRT-Ⅲ and intraocular lens (IOL) Master,were performed on all the subjects.Thc data from right eyes of subjects were collected and analyzed.The linear correlation analysis and multiple linear regression analysis were applied to analyze the correlation between HRT optic papilla configuration parameter and equivalent sphere and ocular axis length.Results A pilot prospective series cases observational study was designed.1748subjects were enrolled in this study.The disc area (DA) (P=0.021),rim area (RA) (P<0.001),rim volume (RV) (P<0.001),mean retinal nerve fiber layer thickness (mRNFLt) (P<0.001) and retinal nerve fiber layer cross section area (RNFLcsa) in the high myopia were greater than those of the emmetropic group,with significant difference between the two groups (P<0.001).However,the cup area (CA),cup/disk area ratio (C/DAR) and cup volume (CV) were less in the high myopic group than those of the emmetropic group (P=0.004,P<0.001 and P<O.001),respectively.In the mild-moderatc myopic group,the RV,mRNFLt and RNFLcsa were greater than those of the emmetropic group (all of the P value less than 0.001),but the numbers of DA,CA,C/DAR,and CV were less than those of the emmetropic group,the differences were significant and their P valuables were 0.038,< 0.001,<0.001 and 0.001 respectively.The differences of structure parameters between the hyperopia group and the emmetropic group were not statistically significant (P>0.05).The DA,CA,RA,C/DAR,CV,RV,mean cup depth (MCD),maximum cup depth (MxCD),cup shape measure (CSM),mRNFLt and RNTLcsa were (2.04±0.43) mm2,(0.49±0.34) mm2,(1.55 ± 0.34) mm2,0.23-0.13,(0.11 ± 0.12) mm3,(0.45 ± 0.19) mm3,(0.21 ± 0.09) mm,(0.60±0.21) mm,-0.21 ± 0.07,(0.29 ± 0.07) mm and (1.46 ± 0.36)mm2,respectively,in the 1748 eyes of 1748 subjects.No significant correlation was found between the DA value with SE (r=-0.032,P =0.186).However,weaker positive correlations were seen between the CA,C/DAR,CV,MCD,MxCD with SE (r=0.139,0.163,0.130,0.004,0.054,P< 0.05) and negative correlation between RA,RV,mRNFLt and RNFLcsa with SE (r =-0.178,-0.331,0.241,-0.239,P<0.001).With the increase of the ocular axial length,the DA,RA,RV,mRNFLt and RNFLcsa values were enlarged,and the CV value was smaller.With the increase of CA,the RA,C/DAR,CV,RV,MCD,MxCD,CSM and RNFLcsa values elevated,but mRNFLt value was decreased.Conclusions Refractive error is not associated with DA,but the measuring results are different among various refractive groups.Refractive error,ocular axial length and DA affect the measuring result of HRT.
10.Chronic pain-related factors and the quality of life of fracture victims 27 months after the Sichuan earthquake
Yongxue LI ; Xia ZHANG ; Wenchao YI ; Xiaorong HU ; Mingyue XIAO ; Hong JIN ; Jianan LI
Chinese Journal of Physical Medicine and Rehabilitation 2011;33(9):673-677
Objective To investigate factors related to chronic pain in those injured with fractures 27 months after the Sichuan earthquake.The correlation between intensity of pain and quality of life was also analyzed.Methods A total of 705 victims were investigated on site.Their residual pain was categorized using a visual analogue scale (VAS) score as no pain,mild pain,moderate pain or severe pain.The pain-related biological,psychological and social factors were analyzed using the Barthel Index ( BI ),Life Satisfaction Questionaire-11 ( LiSat-11 )and the SF-36 health questionnaire. Rehabilitation and surgical interventions,employment,income and emotional status were also investigated. Results The incidence of chronic pain was 88.5% in this population,of which mild pain and moderate pain were 35.7% and 33.3%,respectively.The percentage of the victims who had received fracture surgery was 65.8% ; the percentage of those who had recovered was 96.9%.BI scores for the victims without pain,with mild,moderate and severe pain were 92.7 + 10.2,92.8 + 8.4,91.2 ± 9.9 and 90.4 + 14.7,respectively ; the differences between these groups were all statistically insignificant.The influence of pain intensity on life satisfaction showed a significant linear trend.The percentages of the victims with restricted occupational ability in the four groups were 38.3%,61.5%,75.7% and 62.8% respectively.The median of personal annual income were ¥ 3550,¥ 2500,¥ 2000 and ¥ 2500.The VAS scores were significantly related to abnormal emotions,life satisfaction,employment and annual income.The subjects with different levels of residual pain also showed significant differences in the physical functioning,role-physical,bodily pain,general health,vitality,social functioning,role-emotional and mental health sub-scales of the SF-36.The total SF-36 scores were highest among victims without pain (70.6 + 17.5) and declined significantly in those with mild (61.3 + 14.3 ),moderate (52.7 + 14.3 ) and severe pain (52.3 + 14.7 ).This negative correlation between pain intensity and SF-36 total score was statistically significant. Conclusions Chronic pain remains common among fracture victims 27 months after the earthquake.Its intensity is correlated with psychological and social factors as well as quality of life.