1.Analysis of efficacy and safety of operation in treating secondary glaucoma caused by contusion hyphema
International Eye Science 2016;16(8):1567-1569
?AIM:To explore the efficacy and safety of operation in treating secondary glaucoma caused by contusion hyphema.?METHODS: Seventy patients (70 eyes) with secondary glaucoma caused by contusion of anterior chamber in our hospital from November 2014 to November 2015 were selected.All patients were treated by operation.Visual acuity, anterior chamber depth, mean intraocular pressure and postoperative complications of patients before and after operation were compared.?RESULTS:Patients with secondary glaucoma caused by contusion of anterior chamber had better visual acuity after operation and the difference was statistically significant (t=42.471, P<0.001).And they had deeper anterior chamber depth and lower mean intraocular pressure, and the differences were statistically significant (t=9.726, 26.041; P<0.001).Two of those patients had emergence of hyphema after operation and symptomatic relieved after treatment. None of the patients had complications such as blood-staining of cornea or eye pain.? CONCLUSION: The curative effect of operation in treating secondary glaucoma caused by contusion of anterior chamber is good and safe and it can improve visual acuity, deepen the anterior chamber angle depth and reduce the intraocular pressure.
4.Experimental study of gliosis and synaptic reorganization in the hippocampus of chronic temporal lobe epilepsy rats induced by kainic acid
Rong WANG ; Bo XIAO ; Chunxia JING
Chinese Journal of Neurology 2001;0(03):-
Objective To investigate the relationship between gliosis, synaptic reorganization and the mechanism of chronic temporal lobe epilepsy induced by kainic acid. Methods The mossy fibers sprouting, synaptic reorganization and gliosis were observed by Neo-Timm staining and immunohistochemical staining respectively. Results The injected (ipslateral) side was injured predominantly in the CA 3 subfield and hilus, whereas the CA 1 subfield was injured mildlyThe contralateral side showed pathological changes mainly in the CA 1 subfield and hilus, and moderately in the CA 3 subfieldThe longer the rats survived, the more obvious changes were observed in the hippocampuses. Conclusion The injection of kainic acid in hippocampus can cause neuronal loss, reactive gliosis and plasticity of neurons, probably form the abnormal neuronal discharge circuit, finally induce the seizures
5.The correlative relationship between AEEG and MRI in the diagnosis of epileptic patients
Tianjun WANG ; Senyang LANG ; Rong XIAO
Chinese Journal of Neurology 1999;0(06):-
Objective To analyse the role of AEEG and MRI in diagnosis of epilepsy on its primary epileptic focus and pathologic lesions. Methods We reviewed the results of sixty epileptic patients on routine EEG, twenty-four hour active EEG(AEEG),CT scanning and MRI examinations. The relationship between epileptic discharges of AEEG and lesions of MRI was analyzed by using ? 2 test. Results AEEG showed a higher sensitivity in finding epileptic focus in 80% patients, as compared with the rate of 32% in routine EEG. The sensitivity on finding the cerebral lesion related to the epileptic focus by using MRI was 60%, as compared with the rate of 33% in CT scanning. There was a correlative relationship between the AEEG discharge foci and the lesions found by MRI( P
6.The significance of ultrasound in helping 200 cases scarred uterus gravidas chosing their second delivery modes
Changxian RONG ; Xiao ZHOU ; Jian WANG
Chongqing Medicine 2015;(19):2644-2645,2648
Objective To explore the significance of ultrasound in choosing the delivery modality in 200 cases scarred uterus gravida′s second deliveries .Methods The study selected 200 cases late pregnancy gravidas who had once uterine incision delivery history and analyzed clinical data retrospectively ,all of them were chosen from September 2010 to September 2013 in our hospital . All cases were taken by transabdominal ultrasound or transvaginal ultrasound firstly ,then taken by transabdomina transvaginal ul‐trasound ,finally contrast obsenved the transabdomina transvaginal ultrasound detections with their caesarean section observations , meanwhile observe how the uterus scar ranking affect the delivery consequence .Results (1)A total of 200 cases had higher uterus scars visualization ratio(100 .0% ) than ransabdominal ultrasound (92 .0% )and transvaginal ultrasound(96 .5% )(P<0 .05);con‐trasting the transabdomina transvaginal ultrasound with the caesarean section observations ,there was no significant difference(P>0 .05) .The grading diagnosis coincidence of transabdomina‐transvaginal ultrasound was 89 .74% .(2)The UD rate ,the bleeding vol‐ume during operation and the 24 hours postoperative bleeding volume of scarred uterus gravida grade Ⅱ and grade Ⅲ were signifi‐cantly higher than grade Ⅰ (P<0 .05) .Conclusion Transabdomina transvaginal ultrasound can effectively improve the diagnosis coincidence rate of uterine scar detection and can help to chose the better delivery mode according to the scars healing .
7.Influence of Environmental Temperature on Formaldehyde Emission from Blockboard
Xiao-Heng WANG ; Xing-Rong LIU ;
Journal of Environment and Health 2007;0(10):-
Objective To study the effect of temperature on the emission of tbrmaldehyde trom the blockboard.Methods A 0.25 m3 simulation chamber was used to explore the emission of formaldehyde from blockboard at the temperature of 15,17,19,21, 23,25,27,and 29 ℃,respectively.The relative humidity,the ventilation velocity and the loading factor in simulation chamber was (50?1)%,1.0 L/min,and(1?0.03)m~2/m~3 respectively.Results A hyperbolic logarithm variation in formaldehyde concentration with time in the chamber was observed at different temperatures.Formaldehyde concentration in the chamber increased remarkably once the temperature exceeded 25 C.The chamber stabilization formaldehyde concentration varied with temperature in accordance with an exponent equation of y=0.921 9?0.024 9e~(0.176 4x)(R~2=0.996 9).Conclusion The temperature can greatly influence formaldehyde emission from the blockboards.Higher temperature will facilitate formaldehyde emission from the blockboards.
8.Laparoscopy Combined with Hysteroscopy for the Diagnosis and Treatment of Infertility
Rong ZHUO ; Zhonghai WANG ; Tianhui XIAO
Chinese Journal of Minimally Invasive Surgery 2001;0(06):-
Objective To investigate the diagnostic value and therapeutic effect of laparoscopy combined with hysteroscopy in patients with tubal infertility.Methods A total of 133 patients with tubal infertility were treated by laparoscopy combined with hysteroscopy in our hospital from September 2004 to December 2007.All the cases were diagnosed by hysterosalpingography(HSG) and hysteroscopy.Results Totally 225 fallopian tubes were examined in the 133 patients,among which 180 tubes were completely occluded,57 were partially occluded,and 18 were patent.After the surgeries,211 tubes wee patent,24 were partially blocked,while 20 were still occluded.The success rate of the operations was 81.4%(193/237).Follow-up was achieved in 92 patients for 4 to 18 months,in the cases,30 were pregnant during the period(pregnancy rate: 32.6%).Of the 30 cases,2 women had tubal pregnancy;22 women were pregnant in 6 months after the treatments,and the other 8 were pregnant in 6-12 months after the operations.In this group of patients,the pregnancy rate in the women with both patent fallopian tubes was 26.1%(24/92),and in those with single patent fallopian tube was 6.5%(6/92).The pregnancy rate in patients with simple tubal infertility was 22.8%(21/92),while that of those who were complicated with tubal diseases was 9.8%(9/92).Conclusion Laparoscopy combined with hysteroscopy can accurately diagnose tubal infertility,and improve the therapeutic effect.
9.Alkanethiol modified magnetic silver flower nanoparticles applied to detection of chloramphenicol
Ping LI ; Chongwen WANG ; Zhen RONG ; Rui XIAO ; Shengqi WANG
Military Medical Sciences 2016;40(8):634-638
Objective To prepare novel alkanethiol modified magnetic silver flower nanoparticles as SERS substrate to chloramphenicol for Raman detection and to determine their enhancement effect.Methods An alkanethiol was chosen as a surface modifier of the substrate and was self-assembled onto the magnetic silver flower nanoparticle surface.The chloram-phenicol molecules were enriched to the surface of the substrate by hydrophobic interaction and the effect for detection of chloramphenicol SERS signal was enhanced.Results It was found that the 1-hexanethiol-modified SERS substrate was able to lead to stronger enhancement than 1-dodecanethiol and octadecanethiol.Fe3 O4@SiO2-Ag-C6 was used to detect the chloramphenicol (10 -3 -10 -10 mol/L) and chloramphenicol in milk (10 -3 -10 -9 mol/L) by surface-enhanced Raman spectroscopy.The detection limits were 0.1 nmol/L (32 ppt) and 1 nmol/L (323 ppt) respectively.Conclusion Alkanethiol modified magnetic silver flower nanoparticles are a highly active SERS substrate, which can be used for detection of low concentrations of analytical substances.
10.Observations on the Therapeutic Effect of Electroacupuncture on Mild and Moderate Female Stress Incontinence
Wei WANG ; Yiming JIANG ; Rong WANG ; Jinlong XIAO
Shanghai Journal of Acupuncture and Moxibustion 2016;(1):47-49
Objective To investigate the clinical efficacy of electroacupuncture in treating mild and moderate female stress incontinence.Methods One hundred and eighty female patients with mild or moderate stress incontinence were randomly allocated to treatment and control groups, 90 cases each. The treatment group received electroacupuncture and the control group took midodrine hydrochloride tablets. The International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form (ICIQ-UI SF) score was recorded and 1-hour pad test leakage was measured in the two groups before and after treatment. The clinical therapeutic effects were compared between the two groups.Results There were statistically significant pre-/post-treatment differences in the ICIQ-UI SF score and pad test leakage in both groups (P<0.01). There were statistically significant post-treatment differences in the ICIQ-UI SF score and pad test leakage between the treatment and control groups (P<0.01). The total efficacy rate was 86.7% in the treatment group and 68.9% in the control group; there was a statistically significant difference between the two groups (P<0.05).Conclusions Electroacupuncture is an effective way to treat mild and moderate female stress incontinence. It can improve urinary continence and reduce urine leakage in the patients.