3.Quantitative Determination of Selenium Species in Se-enriched Yeast Using Liquid Chromatography-Hydride Generation Atomic Fluorescence Spectrometry
Zhiming XIAO ; Rong SONG ; Zheng JIA ; Yang LI ; Xia FAN
Chinese Journal of Analytical Chemistry 2014;(9):1314-1319
A rapid and sensitive method has been developed for the simultaneous determination of four selenium species Se(Ⅵ), Se(Ⅵ), selenomethionine, and Se-methylselenocysteine in Se-enriched yeast by liquid chromatography-hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS). The isolation of the analytes from yeast samples was accomplished by proteaseⅩⅣ and trypsin enzymatic digestion. The target compounds were separated on a PRP-X100 anion exchange column and analyzed by HG-AFS. The mobile phase was 20 mmol/L (NH4)2HPO4. Good linearity was obtained for all the selenium species, with linear correlation coefficients higher than 0. 9996. The LODs of the four species were between 0. 5 and 5. 0 μg/kg. Average recoveries for the four analytes were in the ranges of 82 . 5%-101 . 2%, with intra-and inter-day RSD lower than 8. 6% and 14. 5, respectively. The proposed analytical method is simple, sensitive, with low operation cost, making it applicable for the determination of the selenium species in Se-enriched feeds.
4.Application of Stream-media Transmission Technology in PACS and Distance Diagnosis
Wei SONG ; Jia-Xue QI ; Xiao-Hui OUYANG ;
Chinese Medical Equipment Journal 2004;0(09):-
Objective To propose a stream-media technology based on the new transmission technology. Methods Firstly,we explored the advantages and disadvantages of exiting PACS image in LAN (Local Area Network) and WAN (Wide Area Network) and then expounded distance diagnosis related to HIS and PACS,VPN technology,wireless network applications,more points consultation applied technology. At last,we made an analysis of the characteristics of the stream-media transmission technology. Results The characteristics of low bandwidth occupied,high security,and high scalability of stream-media transmission technology fit the needs of PACS development. Conclusion Application of streammedia technology transferred in PACS image provides a new economical and practical technical solution to break through limitation of network bandwidth in medical imaging integrated information,and to thoroughly make use of medical resource.
5.Analysis of the associated complication with circulatory support device
Ming JIA ; Ye ZHOU ; Juanjuan SHAO ; Zhimin LUO ; Xiao ZHOU ; Tieying SONG ; Shijie JIA
Chinese Journal of Emergency Medicine 2008;17(8):867-869
Objetctive To summarize the associated complications with circulatory support device,and provide reference for chnical practice.Method A total of 8306 consecutive patients who underwent open heart surgery,in Department of Post-operation Intensive Care Unit of the Cardiac Surgery,Anzhen Hospital,Capital Medical University,was retrospectively studied from January 2005 to February 2007.And the clinical data of 246 patients including 63 female and 183 male patients with mean age 56.7±14.2 years supported with various circulatory support devices for perioperative cardiorespiratory function failure in ICU were analyzed.Left ventricular assist device (LVAD) was used in 3 patients by the cannulation of the left alritan and ascending aorta.The extracorporeal membrane oxygenation(ECMO) was established in 48 patients for postoperative cardiorespiratory function failure.The vencarterial bypass was established by cannulation of the right atrium in 41 patients and femoral artery and of venovenons in 2 patients,and of the right atrium and ascending aorta in 5 cases,lntra-aortic balloon pumping(I-ABP)was performed via the femoral artery either percutaneonsly by the Seldinger technique in 195 patients.The cardiac operations included coronary artery bypass grafting (n=170),coronary artery bypass grafting with romoldingof left ventricle (n = 22),coronary artery bypass grafting with valvular operation (n=10),valvular operation (n=27),heart transplantation(n=8),correction of congenital heart defects(n=6),aortic operations(n=2).The duration of circulatory support ranged from 4 to 451 hours.Correlative complications of 3 kinds of circulatory support device were compared and repair of ventricular septal perforation in the wake of acute myocardial infarction (n=1).Results Seventy-eight (31.7%) patients died.Seventy-one(28.9% ) patients devdoped various complications including infection(n=27),renal failure required renal rephcement therapy (n=27),re-exploration for bleeding(n=24),haemolysis(n=6),limb ischemia(n=15),neurological complications(n=6),oxygenator failure(n=7) Conchusions The improvement of management to reduce complications may result in improved outcomes of patients supported with circulatory support devices.
6.Preliminary evaluation of color power doppler ultrasonography in diagnosis of sacroiliitis in patients with ankylosing spondylitis
jia-an, ZHU ; bing, HU ; nian-song, WANG ; xiao-guang, ZHANG ; sheng-li, KUANG ; jia, LI
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(09):-
Objective To preliminarily evaluate the value of color power doppler ultrasonography in the diagnosis of sacroiliitis in ankylosing spondylitis(AS). Methods Fifty-seven sacroiliac joints in 31 patients with active AS and 40 sacroiliac joints in 20 volunteers were detected by color power doppler ultrasonography.The color flow signs inside the sacroiliac joints were observed,and the resistance index(RI) was measured. Results In active AS,color flow signs were seen in 55 joints,and the mean RI value was 0.53?0.08 in 45 joints,while the other 10 color flow signs represented reversed phase in diastolic phase on pulse doppler ultrasonography.In the volunteers,color flow signs were seen in 16 joints,and the mean RI value was 0.97?0.01 in 6 joints,while the other 10 color flow signs represented reversed phase in diastolic phase on pulse doppler ultrasonography. Conclusion The abnormal flow signs at the sacroiliac joints can be detected by color power doppler ultrasonography.Low RI values provide diagnosis evidence for active AS.
7.Identification and early diagnosis for traditional Chinese medicine-induced liver injury based on translational toxicology.
Jia-Bo WANG ; Xiao-He XIAO ; Xiao-Xi DU ; Zheng-Sheng ZOU ; Hai-Bo SONG ; Xiao-Xin GUO
China Journal of Chinese Materia Medica 2014;39(1):5-9
Recently traditional Chinese medicine (TCM)-induced liver injury has been an unresolved critical issue which impacts TCM clinical safety. The premise and key step to reduce or avoid drug-induced liver injury (DILI) is to identify the drug source of liver injury in early stage. Then the timely withdrawal of drug and treatment can be done. However, the current diagnosis of DILI is primarily governed by exclusive method relying on administering history supplied by patients and experience judgment from doctors, which lacks objective and reliable diagnostic indices. It is obvious that diagnosis of TCM-induced liver injury is especially difficult due to the complicated composition of TCM medication, as well the frequent combination of Chinese and Western drugs in clinic. In this paper, we proposed construction of research pattern and method for objective identification of TCM-related DILI based on translational toxicology, which utilizes clinical specimen to find specific biomarkers and characteristic blood-entering constituents, as well the clinical biochemistry and liver biopsy. With integration of diagnosis marker database, bibliographic database, medical record database and clinical specimen database, an integrative diagnosis database for TCM-related DILI can be established, which would make a transformation of clinical identification pattern for TCM-induced liver injury from subjective and exclusive to objective and index-supporting mode. This would be helpful to improve rational uses of TCM and promote sustainable development of TCM industry.
Animals
;
Biomarkers, Pharmacological
;
metabolism
;
Biopsy
;
methods
;
Chemical and Drug Induced Liver Injury
;
diagnosis
;
metabolism
;
pathology
;
Early Diagnosis
;
Humans
;
Liver
;
drug effects
;
pathology
;
Medicine, Chinese Traditional
;
adverse effects
;
Rats
8.Clinicopathologic study of 8 cases of lipoprotein glomerulopathy.
Li-fen XU ; Jia CHEN ; Song-song HUANG ; Qing MENG ; Xiao ZENG
Chinese Journal of Pathology 2008;37(6):408-409
Adult
;
Female
;
Humans
;
Hyperlipoproteinemia Type III
;
pathology
;
Male
;
Middle Aged
;
Nephrosis, Lipoid
;
pathology
9.Animal biodistribution and pharmacokinetics study of ~(131)I-labelled rch24
Haiwei JIA ; Qing NIE ; Haifeng SONG ; Baozhen ZHU ; Xiao SUN ; Xiaojun MIAO ; Lun OU
Cancer Research and Clinic 2009;21(11):724-727
Objective To evaluate biodistribution and pharmacokinetics pattern of ~(131)I-labeled rch24which is the region-grafted (humanized) anti-carcinoembryonic antigen (CEA) monoclonal antibody in nude mice. Methods Nude mice bearing cancer xenografts received intravenous injections of ~(131)I- rch24, then blood, plasma, heart, liver, spleen, lung, kidney, tumor and other tissues were taken at different time point for determination the concentration of radioactivity and calculate the T/NT value. Nude mice were packeted randomly to four group of high, medium, low dose and continuous administration, blood drug concentration was detected by ELISA method at the different intervals. Then, draw the concentration-time curve and calculate the pharmacokinetics paramete. Results After administration, radioactivity of the tumour was significantly enhanced whereas radioactivity of normal tissues decreased gradually. For single administration, at the dose of low to medium, pharmacokinetics pattern was linearity -kinetics whereas for high dose group,pharmacokinetics paramete shown some behavior of non-linearity-kinetics. Conclusion Our results suggest that the ~(131)I-labeled region-grafted (humanized) anti-CEA monoclonal antibody rch24 exhibit a considerable targeting activity so as to ~(131)I radioisotopes can be concentrated specifically in tumor. The pharmacokinetics pattern of this medicine was different at different dose.
10.Pharmacokinetics of levofloxacin in rat pancreas
Deding LIU ; Heping XIAO ; Zhuo WANG ; Jia ZHOU ; Bin SONG ; Lin YANG ; Rui LIU ; Yi HUANG
Chinese Journal of Pancreatology 2010;10(2):92-95
Objective To investigate the pharmaeokinetics of levofloxacin in rat's pancreatic tissue. Methods Pancreatic tissue and blood were sampled in vivo by microdialysis simultaneously. The concentrations of levofloxacin in beth blood and tissues were measured by high performance liquid chromatography. All date were analyzed by WinNonlin software. Results The maximum concentration of free levofloxacin in blood and pancreatic tissue were (65.23 ± 12.9) μg/ml at 10min and (30.56±3.22) μg/ml at 20 min, respectively, then beth continuously decreased. Concentration of free levofloxacin in pancreatic tissue was higher than that in blood from 20min to 100min, then returned to similar level. The area under the concentration curve(AUC)of unbound levofloxacin was(2465.11±258.56)min·μg~(-1)·ml~(-1) in pancreas,and (2914.38±205.73)min·μg~(-1)·ml~(-1) in blood.Conclusions Microdialysis with reversed phase high performance liquid chromatography established in this essay could be used to determine the pharmacokinetics of levofloxacin objectively. High concentration of levofloxacin in pancreatic tissue and blood was observed.