1.Treatment of osteochondritis lesion in the knee with reduction and fixation under arthroscopy.
Xiao-feng HU ; Shan-shan WEI ; Shao-shan WANG
China Journal of Orthopaedics and Traumatology 2015;28(10):963-966
OBJECTIVETo study clinical results of reduction and fixation under arthroscopy for the treatment of osteochondrotical lesion in the knee.
METHODSFrom December 2012 to December 2013, 4 patients with the knee joint osteochondritis lesion and free bone fragments were treated with arthroscopy to detect the stripped cartilage, and then the cartilages were reduced with small incision and fixed by cartilage nail. There were 3 males and 1 female, with age of 15, 15, 20 and 27 years old. The durations of the disease were 1 d, 5 d, 1 month and 1 year. All the patients had swelling and effusion in the knee joint, and the floating patellar test was positive. CT examination showed bone defects and loose bodies. The Lysholm, VAS, and Tegner scale were used to evaluate the knee joint functions before and after operation.
RESULTSAll the patients underwent successful surgery. Postoperative CT showed good location of the cartilage without loss of reduced bone and cartilage. All the patients were followed up, and the duration ranged from 10 to 13 months, with a mean of 12 months. In one patient, arthroscopy examination was conducted for a second time to examine the connection of the fracture part to the surrounding cartilage, and it showed that the internal fixator was not absorbed. The Lysholm, VAS and Tegner scale of all patients were better than those before operation.
CONCLUSIONTreatment of osteochondritis lesion with the fixation of absorbable cartilage nails may reconstruct the integrity of articular surface and recover the stability of joints, and it is an effective treatment method.
Adolescent ; Adult ; Arthroscopy ; methods ; Female ; Humans ; Knee Joint ; surgery ; Male ; Osteochondritis Dissecans ; etiology ; physiopathology ; surgery ; Tomography, X-Ray Computed ; Visual Analog Scale
2.Study on the polymorphysm of MTHFR gene in coronary heart disease in Guizhou
Yan XIAO ; Zhiheng HU ; Keren SHAN
Chinese Journal of Practical Internal Medicine 2001;0(04):-
Objective Study on methylenetetrahydrofolate reductase(MTHFR)gene polymorphism in coronary heart disease.Methods Detect the MTHFR C677T gene polymorphism by PCR-RFLP in 73 cases of healthy individuals and 87 cases of coronary heart diseas(CHD).Results At the site of 677,the T allele frequencies are 18.5%,36.1%,respectively,for healthy individuals and 87 cases of coronary heart disease.The frequecies of MTHFR CT genotype and T allel were significantly higher in disease groups.There are significant differences between disease group and control group(P
3.Application of internal fixation combined with external fixator for unstable pelvic fracture.
Jin-hua GAO ; Wei HU ; Xiao-shan GUO
China Journal of Orthopaedics and Traumatology 2015;28(8):753-756
OBJECTIVETo invesitigate the clinical effects of percutaneous closed reduction and cannulated screw internal fixation combined with external fixation in the treatment of unstable pelvic fractures.
METHODSFrom April 2006 to May 2009,29 patients with pelvic fractures of rotatory instability were treated with closed reduction and screw internal fixation combined with external fixation. There were 19 males and 10 females with an average age of 31 years old (ranged from 19 to 53 years). Based on the Tile classification,17 cases were type CI and 12 case were type C2. Tornetta standard and Majeed score were used to evaluated the clinical effect after operation.
RESULTSAll patients were followed up from 10 to 24 months with an average of 16 months. There were no nerve injuries and other organ injuries, only one case of infection was found and it was cured with wound dressing. Time of fracture union was from 14 to 18 weeks with the mean of 16.2 weeks. No loosening, slippage or breakage of the screw were found. According to the Tornetta standards,14 cases obtained excellent results, 10 good, 4 fair and 1 poor. The Majeed score was 87.2 ± 11.3, 16 cases got excellent results, 9 good and 4 fair.
CONCLUSIONClosed reduction and screw internal fixation combined with external fixation is an effective way to treat unstable pelvic fractures with Tile type C1 and Tile type C2.
Adolescent ; Adult ; Child ; External Fixators ; Female ; Fracture Fixation, Internal ; methods ; Fractures, Bone ; surgery ; Humans ; Male ; Middle Aged ; Pelvic Bones ; injuries ; surgery
4.Research progress of chemokines and their receptors in breast cancer
Wan-yu WANG ; Xiao-xi LÜ ; Zhuo-wei HU ; Shan-shan LIU
Acta Pharmaceutica Sinica 2021;56(6):1521-1531
Chemokines are small cytokines with chemotactic activity, they are involved in regulating immune responses and inflammatory responses. In the development of tumors, chemokines are multi-functional mediators that not only affect the infiltration of immune cells into the tumor, but also have an important impact on tumor growth, angiogenesis, invasion, and metastasis. Besides, they are important targets of tumor therapy. Here we review chemokines involved in the regulation of signaling pathways, analyze the mechanism of chemokines in the development of breast cancer, summarize the chemokines targeted drugs for breast cancer in recent years and make a prospect about the role of chemokines in anti-breast cancer therapy.
5.Evaluation of performance measurement system of gastrointestinal endoscopy based on deep learning (with video)
Ming XU ; Liwen YAO ; Shan HU ; Xiao HU ; Jinzhu LIU ; Honggang YU
Chinese Journal of Digestive Endoscopy 2021;38(2):107-114
Objective:To construct an intelligent performance measurement system of gastrointestinal endoscopy and to analyze its value for endoscopic quality improvement.Methods:The intelligent gastrointestinal endoscopy performance measurement system was developed by using the deep convolutional neural network (DCNN) and deep reinforcement learning, based on the Digital Imaging and Communications in Medicine. Images were acquired of patients undergoing gastrointestinal endoscopy at Digestive Endoscopy Center of Renmin Hospital of Wuhan University from December 2016 to October 2018. The system applied cecum recognition model (DCNN1), images in vitro and in vivo recognition model (DCNN2), and identification model at 26 gastric sites (DCNN3) to monitor indices such as cecal intubation rate, colonoscopic withdrawal time, gastroscopic inspection time, and gastroscopic coverage. Images of 83 gastroscopies and 205 colonoscopies acquired at Digestive Endoscopy Center of Renmin Hospital of Wuhan University from March to November 2019 were randomly selected to examine the effectiveness of the system. Results:The intelligent gastrointestinal endoscopy performance measurement system consisted of quality analysis of both gastroscopy and colonoscopy, including all indices, and could be generated automatically at any time. The accuracy for cecal intubation rate, colonoscopic withdrawal time, gastroscopic inspection time, and gastroscopic coverage were 92.5% (172/186), 91.7% (188/205), 100.0% (83/83), 89.3% (1 928/2 158), respectively.Conclusion:The intelligent performance measurement system for gastrointestinal endoscopy can be recommended for the quality control of gastrointestinal endoscopy, from which endoscopists can get feedback and improve the quality of gastrointestinal endoscopy.
6.Delayed union or nonunion of the ulna after intramedullary nailing for pediatric forearm fractures.
Sheng-Hu DU ; Jie YANG ; Xiang-Xiang HUANG ; Xiao-Shan GUO ; Yong-Zeng FENG
China Journal of Orthopaedics and Traumatology 2014;27(7):605-608
OBJECTIVETo analyze the causes of delayed union or nonunion of the ulna after intramedullary nailing in pediatric forearm fractures.
METHODSFrom February 2005 to February 2010,5 patients with forearm fractures who were treated with titanium elastic nailing (TEN) were identified to fulfill the criteria of having developed a delayed union or nonunion of the ulna. The causes of delayed union or nonunion were investigated according to mechanism of injury, fracture location, treatments methods and postoperative management. All patients were male and the age was 3 to 14 years old with an average of 9.4 years. All fractures were located on the mid-third part of forearm. Two cases had a re-fracture. Among them, 3 cases caused by high-energy injury and 2 cases by falling down. Open reduction were performed in 4 cases while the other one was treated with closed reduction. Four patients were immobilized in an above-elbow cast, postoperatively.
RESULTSAll patients were followed up from 7 to 19 months with an average of 11.4 months. There were 4 delayed union and 1 nonunion. Three patients healed after the removal of the nail and avoidance of weight-bearing. Two patients healed by replacing another fixation. No patients had soft-tissue irritation or nail-entry-site infections.. The clinical effect was evaluated according to Daruwalla and Price scores with 3 excellent and 2 good of the results.
CONCLUSIONSUsing titanium elastic nailing for the treatment of pediatric both-bone forearm fractures is a good method. However,strict indication selection should be followed to avoid delayed union or nonunion.
Adolescent ; Child ; Child, Preschool ; Fracture Fixation, Intramedullary ; methods ; Fracture Healing ; Humans ; Male ; Radius Fractures ; physiopathology ; surgery ; Retrospective Studies ; Ulna Fractures ; physiopathology ; surgery
7.One case of parotid gland fistula caused by the external auditory canal cholesteatoma.
Zhi PEI ; Xiao-bo ZHANG ; Hu-shan DENG ; Ji LU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2006;41(1):42-42
Adolescent
;
Cholesteatoma
;
microbiology
;
Ear, External
;
Fistula
;
etiology
;
Humans
;
Male
;
Parotid Gland
8.Studies on Stability of Hesperidin in Alkaline Solution
Yumei HU ; Zhaoqing MENG ; Shan ZHANG ; Ningbo CHENG ; Gang DING ; Zhenzhong WANG ; Wei XIAO
World Science and Technology-Modernization of Traditional Chinese Medicine 2014;(10):2270-2273
This article was aimed to study the stability of hesperidin in alkaline solution, in order to provide experi-ment evidences for quality control of extraction and purification as well as formulation development. RP-HPLC was applied to determinate content changes of hesperidin in alkaline solution by changing the temperature, pH and heat-ing time. The results showed that hesperidin was degraded in alkaline solution by heating. The content of hesperidin decreased along with the increasing of heating temperature and heating time. The hesperidin appeared to be more stable in a weak base. It was concluded that for the purpose of ensuring of the stability of hesperidin in alkaline so-lution, it should be kept at low temperature (below 50℃), weak base conditions and shorten the heating time during the preparation process.
9.The proprioception of knee and its correlation with pain and dysfunction in patients with knee osteoarthritis
Yi WU ; Xiao-Jie YU ; Yong-Shan HU ; Yu-Long BAI ;
Chinese Journal of Physical Medicine and Rehabilitation 2003;0(05):-
Objective To determine the extent and distribution of error in knee joint proprioception and e- valuate the relationship between knee joint proprioception and pain and dysfunction.Methods Twenty-eight knee OA patients (19 female and 9 male) were compared with 27 age-matched healthy adults (20 female and 7 male). Knee joint proprioception was measured with a repositioning test on the Biodex dynamometer.The pain and knee dys- function were assessed with Visual Analogue Scale and Lequesne Index,respectively.Results Knee OA patients produced 79% more proprioception errors than the healthy subjects (P
10.Top-quality Course Construction for Bioprocess Equipment
Yuan-Shan WANG ; Zhong-Ce HU ; Jian-Miao XU ; Xiao-Long CHEN ; Yu-Guo ZHENG ;
Microbiology 2008;0(11):-
Bioprocess equipment is of great importance in application of modern industrial biotechnology.With the rapid development of industrial biotechnology,demands for talents capable of understanding the theory,design and manipulation of modern bioprocess equipment increased.The experiences in aspects such as the building of teachers' contingent,construction of teaching materials,innovation of teaching method from the top-quality course construction of Bioprocess Equipment was discussed in this paper.