1.Achilles tendon graft matches with bone tunnel of different sizes for anterior cruciate ligament reconstruction
Chinese Journal of Tissue Engineering Research 2013;(31):5620-5625
BACKGROUND:Anterior cruciate ligament is the important anatomic structure to maintain the knee joint stability. The tendon bone healing and clinical functional recovery after anterior cruciate ligament have attracted more attention. OBJECTIVE:To observe the healing of graft tendon and surrounding bone with histological method through the same diameter grafts matching with the bone tunnel of different sizes in the anterior cruciate ligament reconstruction surgery, and to detect the functional recovery with biomechanics. METHODS:Middle 1/3 of canine autologous tendon was selected as the anterior cruciate ligament graft, and then trimmed into the same diameter of 4 mm. Sixteen adult mongrel canine were randomly divided into four groups. The anterior cruciate ligament was resected completely, and the tibial and femoral tunnels were prepared on the end sites of tibia and femur with the diameters of 5, 4.5, 4 and 3.5 mm, then implanted into the tendon in prepared and linked into the bone tunnel. At 6 weeks after reconstruction, the experimental canine were sacrificed under general anesthesia to col ect the tissue and organs in the surgical area. Then the hematoxylin-eosin staining, biomechanical testing and statistical analysis were performed. RESULTS AND CONCLUSION:At 6 weeks after anterior cruciate ligament reconstruction, anatomical observation showed that there were no significant differences in growth of grafts and bone tunnels between groups;hematoxylin-eosin staining showed sharpey-like fibronectin could be seen in the tendon bone healing surface, and the col agen fibers in the 3.5 mm bone tunnel group were more compact and regular than those in the other groups;the biomechanical testing results in the 3.5 mm bone tunnel group were better than those in the other groups. The results indicate that during anterior cruciate ligament reconstruction, decreasing the diameter of bone tunnel that matched with grafts in order to make the tendon and the bone tunnel closely matched can provide a more stable cel biological and mechanical environment, accelerate the formation and transformation of tendon-bone healing interface, and can improve the quality of tendon-bone healing.
2.Mechanical properties of cobalt-chromium alloys containing different proportion of once-used alloys after recasts
Yue XIAO ; Dandan REN ; Dan WANG
Chinese Journal of Tissue Engineering Research 2013;(42):7396-7401
BACKGROUND:There are numerous studies about mechanical changes of recast cobalt-chromium ceramic al oys. However, little is reported on the mechanical properties of cobalt-chromium ceramic al oys containing once-used al oys after recasts.
OBJECTIVE:To study the effects of different proportion of once-used al oys to recasting cobalt-chromium al oys on their mechanical properties, including tensile strength, yield strength, elongation and hardness.
METHODS:Cobalt-chromium al oys cast samples were prepared and recast for three times (40%once-used al oys were added per time). The tensile strength, 0.2%yield strength, percentage of elongation, flexural strength and Vickers hardness of each specimen were measured. In addition, microscopic metal ographic observation was done.
RESULTS AND CONCLUSION:Being recast for three times, cobalt-chromiun al oys showed no significant differences on their tensile strength, 0.2%yield strength, percentage of elongation, flexural strength and Vickers hardness. GenerationⅠal oy samples had uniform size, smal diameter and smal carbide size distributing along the grain boundary, mainly exhibiting spherical and irregular wormlike forms. Generations Ⅱ and Ⅲ samples were uniform in shape, but crystal grains were coarsened a little. Carbide from Generation IV samples began to be coarsened, irregular wormlike carbides were increased in amount, and a few of non-metal ic inclusions could be found in grains. Cobalt-chromium al oys can be recast after addition of 40%once-used al oys for three times at least in air environment, without decrease of the mechanical properties.
5.Quality standard study on Entadae Semen.
Hui-ping SHEN ; Meng-yue WANG ; Xiao-bo LI
China Journal of Chinese Materia Medica 2015;40(10):1860-1864
OBJECTIVETo establish the quality standard of Entadae Semen, and provide scientific basis for its quality control.
METHODTLC and HPLC were used for qualitative identification and quantitative analysis of phaseoloidin and entadamide A-O-β-D-glucopyranoside in Entadae Semen. The test of water content, ash and ethanol-soluble extractives of Entadae Semen was carried out according to the methods recorded in appendix of Chinese Pharmacopeia (2010 edition).
RESULTThe TLC was well separated with clear spots. The linear range of phaseoloidin was between 0.014 to 2.747 g x L(-1) (r = 0.999 6, n = 9) with an average recovery rate of 101.06% (RSD 0.90%, n = 6); the linear range of entadamide A-O-β-D-glucopyranoside was between 0.002 to 0.452 g x L(-1) (r = 0.999 7, n = 9) withan average recovery rate of 101.52% (RSD 1.09%, n = 6). The content of phaseoloidin in sample is between 5.12% to 9.24%, entadamide A-O-β-D-glucopyranoside is between 0.55% to 2.17%, alcohol-soluble extracts is between 30.9% to 45.2%, water is between 6.6% to 8.6%, and total ash is between 2.4% to 2.9%.
CONCLUSIONThe established standard is acceptable for quality control of Entadae Semen.
China ; Chromatography, High Pressure Liquid ; Chromatography, Thin Layer ; Drugs, Chinese Herbal ; chemistry ; isolation & purification ; standards ; Fabaceae ; chemistry ; Quality Control
6.Statistical analysis of 512 in-patients with carbon monoxide poisoning.
Yuan-Ping YUE ; Shu-Xia WANG ; Xiao-Qiong CHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(7):491-491
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Carbon Monoxide Poisoning
;
epidemiology
;
therapy
;
Child
;
Child, Preschool
;
Female
;
Humans
;
Infant
;
Inpatients
;
statistics & numerical data
;
Male
;
Middle Aged
;
Young Adult
8.Thighbone and cervical bone fraction internal fixing guide pin director
Xiao-Bin DONG ; Zhu-Hong WANG ; Yue-Mei SUN ;
Chinese Medical Equipment Journal 1993;0(05):-
This paper reports a new type of thighbone and cervical bone fraction internal fixing aim di- rector,it has the advantage of entering pin accuratly,simple operating,short time for x-ray irradiating, little suffering to the patient and being economic.
9.Roles of OPG and OPGL in periprosthetic osteolysis
Xiao-Qing WANG ; Zhen-An ZHU ; Yue-Hua SUN ;
Chinese Journal of Orthopaedic Trauma 2004;0(08):-
Objective To investigate the histological and biochemical responses associated with periprosthetic osteolysis,including the changes of tumor necrosis factor-?(TNF-?),osteoprotegerin(OPG) and os- teoprotegeria ligand (OPEL) in the interface membrane in rat models so as to understand the mechanisms of these interactions.Methods Twenty-four male SD rats were used in this study.A titanium alloy plug was inserted into each distal femur through the knee joint.Polyethylene particles were injected into the left knee at 2,4,6,8 and 10 weeks after implantation of the plugs.Saline solution was injected into the right knee as the control.The animals were killed 12 weeks after implantation.The distal femur was taken from each knee to make histological sections. The samples were made decalcified and stained with hematoxylin and eosin.The histopathological changes were observed under a light microscope.The concentrations of TNF-?in the membrane were assayed by a ELISA kit and the mRNA expressions of OPG and OPEL extracted from the tissue around the plug were detected by RT-PCR. Results The interface membrane taken from the experimental side was found to contain extensive fibrous tissues which extended deeply into the surrounding hone.TNF-?concentrations in the membrane of the experimental side were higher than in the control membrane.There was a significant decrease of OPG mRNA and a significant increase of OPGL mRNA in the membrane around the plug at the experimental side compared with the control side.Con- clusions Polyethylene particles can induce inflammatory responses around the titanium alloy plug.The increase of OPGL expression and reduction of OPG expression in membrane at the experimental side may be induced by TNF-?. Such changes might contribute to the differentiation of osteoclasts and result in the periprosthetic osteolysis.
10.Influence of Electroacupuncture at Acupoints Zusanli(ST 36)and Taichong(LR3) with Different Frequencies on Rats Swimming Endurance
Yue LIANG ; Lei WANG ; Chuan XIAO ; Yi GUO ; Zhongchun ZHU
Journal of Acupuncture and Tuina Science 2006;4(5):261-263
Objective: To observe the influence of electroacupuncture with different frequencies on rats swimming endurance and sift out the optimal frequency parameter.Methods: Wistar rats were randomly allocated to control group, non-acupoint group and electroacupuncture with low frequency group (EA with 2 Hz group), electroacupuncture with medium frequency group (EA with 15 Hz group), and electroacupuncture with high frequency group (EA with 100 Hz group), acupoints Zusanli (ST 36) and Taichong (LR 3) were punctured and rats load swimming time was used as an index, and the change of swimming endurance time before and after acupuncture was observed. Results: After electro-acupuncture, swimming time was increased in 15 Hz and 100 Hz groups respectively, with the significant differences between before and after acupuncture (P<0.05). There was also a significant difference in the percentage of increase in swimming time between 15 Hz group and other groups (P<0.05).Conclusion: It is suggested that electroacupuncture at acupoints Zusanli (ST 36) and Taichong (LR 3) with a frequency of 15 Hz could enhance rats's swimming endurance, and 15 Hz might be an optimal frequency parameter during the electrical stimulation.