4.Electrochemiluminescence Behavior of [ Ru(bpy) 3 ] [4-(Clph) 4 B] 2/N,N,N',N'-Tetrakis(propyl)-pentanediamine Nanopaticles Modified Electrode
Hong RAN ; Ping JIANG ; Baozhan ZHENG ; Hongyan YUAN ; Dan XIAO
Chinese Journal of Analytical Chemistry 2015;(11):1708-1715
A new organic-soluble co-reactant of N,N,N’,N’-tetrakis(propyl)-pentanediamine (TPPD) was synthesized and co-immobilized with tris ( 2, 2’-bipyridine ) ruthenium ditetrakis ( 4-chlorophenyl ) borate ([Ru(bpy)3][4-(Clph)4B]2) on an indium tin oxide (ITO) electrode for electrochemiluminescent (ECL) study. The hydrophobicity of TPPD prevented its leakage from the electrode surface, thus the long-term stability of the ECL electrode was enhanced. The TPPD/[Ru(bpy)3][4-(Clph)4B]2 modified-ITO electrode exhibited strong, stable and reproducible ECL signal. The ECL signal could be quenched efficiently by phenol with a quenching efficiency of 95. 4% in the presence of 0. 1 mmol/L phenol, demonstrating the potential of the modified electrode in determination of phenolic compounds. The transient-state of the electrogenerated chemiluminescence reaction was also investigated, which revealed that the TPPD/[Ru(bpy)3][4-(Clph)4B]2 modified-ITO electrode had a longer lifetime than conventional TPA-Ru(bpy)2+3 co-reactant system.
5.Assessment of the CT image quality for lung nodule using different field of view and matrix:a phantom study
Yuan FANG ; Xiangsheng XIAO ; Hong YU ; Jing LIU ; Liqing JIN
Journal of Practical Radiology 2016;32(10):1594-1597,1613
Objective To assess the CT image quality of the pure ground glass nodule(pGGN)in chest phantom by using different field of view(FOV)and matrix.Methods CT(Philips Brilliance 128 spiral CT)scans were performed on chest phantom containing 9 artificial pGGNs(diameter≥5 mm)in 3 different FOV (50 mm,150 mm,300 mm ),and were reconstructed in 2 different matrix(512×512, 1 024×1 024),standard kernel.Recorded the CT values and standard deviations (SD)of the nodules and surrounding regions in different FOV and matrix,and calculated the mean standard deviation(MSD),contrast noise ratio (CNR)and signal noise ratio (SNR),then compared the difference among them.Two radiologists assessed the image quality of the pGGNs in blind method respectively,then evaluated the coherence between them using Kappa testing.Results The coherence of 2 observers was substantial or almost perfect.No significant differences were found on MSD,CNR and SNR in different FOV (P value>0.05)when matrix was kept,whereas the visibility of the nodules improved with the FOV changing smaller.And there were significant differences all on MSD,CNR and SNR by using different matrix when FOV was kept.The MSD increased and the CNR,SNR decreased in high-resolution group.The visibility of the pGGNs was not improved obviously in high-resolution group.Conclusion The image quality of the pGGN(diameter≥5 mm)won’t be changed by using smaller FOV when matrix is kept ,but the visibility will be improved with the FOV changing smaller.When FOV is kept,the MSD increased and the CNR,SNR reduced in high-resolution group,but the visibility will not be improved obviously compare to the standard resolution group.
6.Effect of Early Intervention for Improving Intellectual Development in Parity with Brain Damage
hong, LI ; yuan, ZHOU ; xiao-lan, QIN ; lian-bin, WEI
Journal of Applied Clinical Pediatrics 1994;0(04):-
Objective To approach the method for improving the intellectual development,of whom had suffered from parity′s brain damage.Methods The patients were divided into 2 groups randomly(age range from 7 days to 18 months) who were observed and compared for 3 years.Group A was bundle of intervention which had been under early intervention program since infant.Group B was bundle of comparing of which had not been under early intervention.Results Observed for 6 months and 12 months,the intellectual development of group A was prior to that of group B(age 6 months P
7.Problems in application of carotid ultrasonography in health checkup population
Yuanming XIAO ; Zhiheng CHEN ; Liuxin WU ; Hong YUAN
Chinese Journal of Health Management 2016;(1):66-70
Carotid ultrasound examination is a very mature examination method, it is widely used in clinical diagnosis and health checkup. Carotid ultrasound examination plays an important role in the prediction of the occurrence of cardiovascular disease. However, there are still certain problems in the application of the examination in the domestic health checkup population, which mainly include that the method and the standard are not unified, and the reporting form is not standardized. Carotid ultrasound examination must be standardized as soon as possible.
8.Investigation of PML-RAR? fusion gene in acute promyelocytic leukemia by real-time quantitative reverse transcription PCR
Hong YUAN ; Nan WANG ; Shi-Jun LI ; Jing WANG ; Hong ZHU ; Xiao-Guang XIAO ; Min HUANG ;
Chinese Journal of Laboratory Medicine 2001;0(04):-
Objective To investigate the relapse risk assessment for patients with acute promyelocytic leukemia(APL)through testing PML-RAR? fusion gene by real-time quantitative polymerase chain reaction(RQ-PCR).Methods Relative copies of PML-RAR? fusion gene were measured in 25 patients with APL in phases of first diagnosis,complete remission(CR)and relapse.The minimal residual disease(MRD)situations were also monitored in 6 of the 25 patients.Results Different PML-RAR? fusion gene expression levels were observed in patient groups of different phases of the disease.(P
9."Myositis-like" T-cell lymphoma: report of a case.
Xiao-ge ZHOU ; Yan SHI ; Gang CHEN ; Yuan-yuan ZHENG ; Yan-ning ZHANG ; Shu-hong ZHANG
Chinese Journal of Pathology 2008;37(6):422-423
10.Rapid molecular identification of pseudostellariae radix.
Dan ZHAO ; Tao ZHOU ; Wei-Ke JIANG ; Yuan YUAN ; Cheng-Hong XIAO ; Wei ZHENG
China Journal of Chinese Materia Medica 2014;39(19):3689-3694
To establish a convenient and rapid method for identification of Pseudostellariae Radix by molecular identification, the rDNA-ITS sequences of Pseudostella riaheterophylla and its adulterants had been aligned to find out specific fragment. The specific primers against the fragment were designed and the PCR amplification conditions were optimized. The fluorescence reaction of the PCR products colored by 100 x SYBR Green I was observed under UV. The concentration of reaction buffer included 5.5 μL DNA Taq polymerase premix, 10 pmol Tzs-2F and 10 pmol Tzs-2R, 20-80 ng template DNA, and plus double sterile distilled water to 25 μL. The PCR thermal profile was as follows: predenaturation at 95 degrees C for 1 min, followed by 30 cycles of denaturation at 95 degrees C for 5 seconds, primer annealing and extension at 56 degrees C for 15 seconds, then it was extension at 72 degrees C for 30 seconds. The fluorescence reaction of Pseudostellariae Radix showed green fluorescence, while adulterants had not. Extraction, amplification DNA and all steps of molecular identification could be completed successfully in 40 minutes. The approach could amplify DNA template of Pseudostellariae Radix specificity, and its product with 1 μL 100 x SYBR Green I could engender green fluorescence under UV. The method was simple and accurate, so it could be used for identification of Chinese traditional medicine.
Caryophyllaceae
;
classification
;
genetics
;
DNA Primers
;
genetics
;
Drug Contamination
;
prevention & control
;
Plant Roots
;
classification
;
genetics
;
Polymerase Chain Reaction
;
methods