1.Extracellular Matrix in Liver: Experimental Study and Clinical Application
Feng GAO ; Xiantao KONG ; Yinghua XIE ; Xiaoli WANG ; Lieying FAN ; Jinxing TAN
Academic Journal of Second Military Medical University 1985;0(05):-
Laminin(LN) and hyaluronie acid (HA) are extracellular matrix in liver. The effects of LN and HA on human fetal liver cells proliferation and collagen synthesis were observed and serum levels of LN and HA were assayed m patients with liver diseases by an enzyme immunoassay method. Both LN and HA had a significant effect on the inhibition of cell proliferation and collagen production. However, serum levels of LN and HA were significantly increased in liver cirrhosis comparing with healthy controls and with patients with non-liver diseases. The results suggest that LN and HA may play a role in the feed-back inhibition mechanism in liver fibrogencsis, and assay of LN and HA in serum may be useful to the diagnosis of liver fibrosis.
2.Clinical observation on sirolimus-eluting stent implantation in left main coronary artery bifurcation lesions
Xiantao SONG ; Yundai CHEN ; Shuzheng LV ; Fei YUAN ; Zening JIN ; Rui TIAN ; Xin CHEN ; Feng TIAN
Chinese Journal of Postgraduates of Medicine 2006;0(19):-
Objective To evaluate the acute and long-term results of stenting for left main coronary artery (LMCA) bifurcation lesions. Methods Forty consecutive patients with LMCA bifurcation lesion and normal left ventricular function were included. Sirolimus-eluting stents were performed in all patients. Results (1)The average diameter of LMCA was (0.81?0.48)mm before stenting and increased to (3.53?0.22)mm after stenting.(2)The procedural success rate was 100.0%. In-hospital events including stent thrombosis,Q-wave myocardial infarction,and emergency bypass surgery did not occur in any patients,and non-Q-wave MI in one patient (2.5%).(3)Clinical follow-up was obtained in all patients at (8.43?3.24) months. There were no death and no myocardial infarction during follow-up. The major adverse cardis events rate was 20.0%.(4)The angiographic follow-up rate was 67.5% (27 of the 40 eligible patients),and the restenosis rate was 18.5% (parent vessel only 11.1%,side branch only 3.7%,and both 3.7%).(5)Different type of operation had no influence on restenosis rate during angiographic follow-up. Conclusion Sirolimus-eluting stent implantation for LMCA bifurcation stenosis appears safe and effective with regard to acute and midterm complications.
3.Synergistic effect of atorvastatin and probucol on severity of coronary lesion in patients with borderline coronary lesion
Changjiang GE ; Shuzheng Lü ; Hong LIU ; Lixia FENG ; Xiantao SONG ; Xin CHEN ; Kang MENG ; Fei YUAN ; Fengqing JI ; Yong HUO
Chinese Journal of Emergency Medicine 2012;21(3):277-281
Objective To study the changes of plasma cystatin C level (PcyC),and evaluate the effects of the joint use of atorvastatin and probucol on PcyC and severity of coronary lesion in patients with borderline lesion of coronary artery.Methods One hundred and thirty consecutive patients with borderline coronary lesion assessed by quantitative coronary angiography were enrolled into borderline coronary lesion group (BCL),and another 136 subjects without coronary lesion were enrolled as controls (CTR).And in the meantime,the subjects in BCL group were randomized (closed envelope method) into routine treatment subgroup ( RTT,n =60),and combined treatment subgroup in which patients were treated with atorvastatin 20 mg plus probucol 1.0 g daily in addition to routine medication ( CBT,n =70) for 6 months.There were no statistical differences in basic clinical features between two subgroups.PcyC,high-sensitive C-reactive protein (hs-CRP),total cholesterol (TC),low-density lipoprotein cholesterol (LDL-C),high-density lipoprotein cholesterol ( HDL-C ) and triglycerides (TG) were determined.Of them,104 patients in BCL group rechecked by coronary angiography.Comparison of biomarkers carried out between two groups by using a number of independent-sample t-test and analysis of variance.For enumeration data,chi-square test was used to compare mean values of biomarkers between groups. P < 0.05 was considered statistically significant.Results PcyC levels were significantly higher in BCL group than those in CTR group ( P < 0.05 ).Compared with RTT subgroup,levels of PcyC,TC,LDL-C,TG and hs-CRP were more significantly decreased in CBT subgroup (P < 0.05,P < 0.01 ).Moreover,there was a trend of slight decrease in the mean percent of stenosis (MPS) of coronary artery with borderline lesion in RTT subgroup treated for 6 months,whereas more marked decrease in the MPS of coronary artery with borderline coronary lesion in CBT subgroup treated for 6 months ( P > 0.05 ; P < 0.05 ).Conclusions Cystatin C plays an important role in the pathogenesis of coronary artery,and PcyC is associated with severity of coronary lesion,the combination of atorvastatin and probucol decreases the PcyC level,and it may be the treatment of choice for borderline lesion of coronary artery.
4.Correlation between monitor units and pass rate of plan dose verification in VMAT plan for different cancers
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2023;32(6):546-550
Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.
5.Repeated sub-acute stent thrombosis: a case report.
Jing DAI ; Shuzheng LYU ; Xiantao SONG ; Hong LIU ; Rui TIAN ; Xin CHEN ; Changjiang GEI ; Yuan ZHOU ; Feng XU
Chinese Journal of Cardiology 2014;42(3):254-255
Aged
;
Humans
;
Male
;
Stents
;
adverse effects
;
Thrombosis
;
etiology
6.Application of helical tomotherapy in the treatment of synchronous bilateral breast cancer
Xiantao HE ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2022;42(12):943-949
Objective:To study the differences in the dosimetry and delivery time between helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) in postoperative radiotherapy of synchronous bilateral breast cancer (SBBC) and to explore the feasibility of clinical application of the HT technology.Methods:A retrospective analysis was conducted for nine SBBC patients who underwent modified radical postoperative radiotherapy in the Fourth Affiliated Hospital of Guangxi Medical University from February 2017 to May 2022. For each patient, the Precision planning system was used to formulate the HT plan, and the RayStation planning system was employed to develop the VMAT plan. All plans obtained were divided into HT group and VMAT group according to plan type. The paired sample t-test was used to compare the dosimetric parameters of the target volume and organ at risk (OAR) and delivery time between the two radiotherapy technologies. Results:The plans of both groups could meet the clinical treatment requirements. The coverage ( D95% and V100%), conformity index (CI), average dose ( Dmean), and median dose ( D50%) of the target volumes in the HT group were better than those in the VMAT group, and the differences were statistically significant ( t=-3.21, -3.39, -5.03, 3.76, 4.97, P < 0.05). The differences in the maximum dose ( D2%), minimum dose ( D98%), high dose volumes ( V107% and V110%), and homogeneity index (HI) of the target volumes between the two groups were not statistically significant ( P > 0.05). Regarding the OAR, the V20 and Dmean of both lungs in the HT group were significantly lower than those in the VMAT group, but the irradiation volume V5 of both lungs in the HT group was significantly higher than that in the VMAT group ( t=-3.01, 3.83, -2.81, P < 0.05). Moreover, V20, V30, V40, and Dmean of heart and the V20 and Dmean of liver in the HT group were significantly lower than those in the VMAT group, with statistically significant differences ( t=3.76, -2.83, -2.74, 5.93, 4.57, 4.48, P < 0.05). There was no significant difference in the radiation doses to other OARs (spinal cord, thyroid gland, and humerus head, P > 0.05). The delivery time of the HT group was significantly higher than that of the VMAT group ( t = 11.32, P < 0.05). Conclusions:Compared with VMAT, HT has greater dosimetric advantages, and can provide higher target coverage, conformability and average dose, and significantly reduce the overall radiation doses to both lungs, heart, and liver in OARs. However, the irradiation volume V5 at low-dose areas of both lungs and the delivery time in the HT group are higher than those in the VMAT group, but still meet the clinical treatment requirements. Therefore, it is feasible to apply the HT technology to the modified radical postoperative radiotherapy of SBBC.
7.Construction of controllable polyethylene glycol bioactive coating with hemocompatibility from the surface of modified glass substrate.
Yu WEI ; Jingxun ZHANG ; Yuzhong ZHANG ; Xiantao FENG ; Xuanhuang YANG
Journal of Biomedical Engineering 2019;36(2):260-266
A diblock copolymer, poly(ethylene glycol) methacrylate-block-glycidyl methacrylate (PEGMA-GMA), was prepared on glass substrate by surface-initiated atom transfer radical polymerization (SI-ATRP), and endothelial specific peptide Arg-Glu-Asp-Val (REDV) was immobilized at the end of the PEGMA-GMA polymer brush by ring opening reaction through the rich epoxy groups in the GMA. The structure and hydrophilicity of the polymer brushes were characterized by static water contact angle, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The results showed that the REDV modified copolymer brushes were successfully constructed on the glass substrates. The REDV peptide immobilized onto surface was quantitatively characterized by ultraviolet-visible spectroscopy (UV-VIS). The blood compatibility of the coating was characterized by recalcification time and platelet adhesion assay. The results showed that the polymer coating had good blood compatibility. The multifunctional active polymer coating with PEGMA and peptide produced an excellent prospect in surface construction with endothelial cells selectivity.
Biocompatible Materials
;
Cells, Cultured
;
Endothelial Cells
;
Glass
;
Humans
;
Immobilized Proteins
;
Methacrylates
;
Oligopeptides
;
Platelet Adhesiveness
;
Polyethylene Glycols
;
Polymers
;
Surface Properties
8.Clinical value of helium-free magnetocardiography in diagnosis of coronary heart disease
Feng XU ; Chenchen TU ; Shuwen YANG ; Ming DING ; Bin CAI ; Huan ZHANG ; Linqi LIU ; Xueyao YANG ; Shu ZHOU ; Zhao MA ; Xiantao SONG ; Hongjia ZHANG
Chinese Journal of General Practitioners 2023;22(11):1159-1166
Objective:To assess the clinical value of helium-free magnetocardiography(MCG) in the diagnosis of coronary artery disease(CAD).Methods:A total of 213 patients with suspected CAD undergoing MCG in Beijing Anzhen Hospital were enrolled in the study. All patients underwent coronary CT angiography/invasive coronary angiography(CCTA/ICA) within 48 hours after MCG scanning. The parameters of MCG, including magnetic field multipolarization, magnetic field unipolarization, T-wave flattened, change in magnetic field distribution at TT segment, abnormal T-peak amplitude ration of maximum to minimum, significant movement of poles, magnetic field angle deviation and abnormal distribution of positive pole were used for the evaluation of the stenosis of coronary arteries.Results:Among 213 patients, MCG scanning was completed in 193 cases(90.6%), while 20 cases were excluded for various reasons. The CCTA/ICA results were taken as gold standard, the total coincidence rate of MCG with the degree of stenosis was 88.60%(95% CI: 83.25%-92.72%), the sensitivity and specificity of MCG in the diagnosis of CAD was 89.63%(95% CI: 83.21%-94.21%) and 88.23%(95% CI:78.12%-94.78%), respectively; the positive and negative predictive value were 93.80%(95% CI:88.72%-96.68%) and 81.08%(95% CI:72.15%-87.64%), respectively. Conclusion:MCG is highly accurate in the diagnosis of CAD, it may be widely used clinically as an non-invasive method free of radiation or contrast agent.
9. Dosimetric effect of set-up errors on nasal NK/T cell lymphoma based on dose reconstruction
Zhanyu WANG ; Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG
Chinese Journal of Radiation Oncology 2019;28(11):849-853
Objective:
To evaluate the dosimetric effects of set-up errors on nasal NK/T cell lymphoma by introducing set-up errors into the radiotherapy planning system for dose reconstruction.
Methods:
Ten patients with nasal NK/T cell lymphoma were recruited. A non-coplanar volumetric modulated arc therapy plan was designed for CT image and clinical target area of each patient. After the completion of the plan, the set-up errors were introduced into the radiotherapy plan by changing the ISO of the treatment, and dose calculation was performed to reconstruct the dose distribution.
Results:
With the increase of system set-up errors, the dose of target was decreased and the order affected by set-up errors in different directions was: left-right direction> head-foot direction> front-rear direction. When the translational set-up errors in each direction were -3 mm to 3 mm and the rotating set-up errors were -3° to 3°, the range of dose change in all targets was less than ±3%. When the set-up errors in all directions were ≤ 3 mm, the dose of organ at risk was less than or similar to the prescribed dose. When the set-up errors were> 3 mm, the doses of lens, spinal cord, parotid gland and optic nerve gradually exceeded the prescribed dose. Only when the rotating set-up errors were ≥ 3°, the dose of lens exceeded the prescribed dose. Special attention should be paid to the influence of the greater set-up errors in the left and right direction on lens, spinal cord and parotid gland, as well as on the spinal cord due to the larger set-up errors in the front and rear direction. After the actual set-up errors were introduced from our department, it exerted slight effect on the irradiation dose of GTV and CTV, which was less than ±2%. In a few cases, the dose of organ at risk potentially exceeded the prescribed dose limit, and special attention should be diverted to overdose of the lens and optic nerve.
Conclusions
The set-up errors will result in target dose deficiency and overdose of organ at risk in nasal NK/T cell lymphoma, especially upon the set-up errors in the left and right direction. The effect of 3 mm and 3° set-up errors on target and organ at risk is limited. Therefore, it is recommended to maintain the single direction set-up errors within 3 mm and 3°. The actual set-up errors introduced from our department exert little effect on the target dose, but a small number of organs are at risk of exceeding the prescribed dose limit. It is necessary to increase the evaluation of the extension region of organ at risk.
10.Short-term outcome of ascending aorta replacement combined with total aortic arch fenestration technique for acute type A aortic dissection
Xiantao MA ; Zhangqiang ZHU ; Yi FENG ; Shiliang LI ; Akilu Wajeehullahi ; Xiang WEI ; Cai CHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(05):577-584
Objective To report our clinical experience and outcomes of thoracic endovascular aortic repair (TEVAR) for acute Stanford type A dissection using ascending aorta replacement combined with implantation of a fenestrated stent-graft of the entire aortic arch through a minimally invasive technique. Methods From 2016 to 2020 in our hospital, 24 patients (17 males and 7 females, aged 45-72 years) with complicated Stanford type A aortic dissection, underwent replacement of the proximal ascending aorta with TEVAR. None of the patients with dissection involved the three branches of the superior arch, and all patients were replaced with artificial blood vessels of the ascending aorta under non-hypothermic cardiopulmonary bypass, preserving the arch and the three branches above the arch, and individualized stent graft fenestration. Results Surgical technical success rate was 100.0%. There was no intraoperative complication or evidence of endo-leak in 1 month postoperatively. Hospital stay was 10±5 d. During postoperative follow-up, the stent was unobstructed without displacement, the preserved branch of the aortic arch was unobstructed, and the true lumen of the descending aorta was enlarged. Conclusion This hybrid technique by using TEVAR with fenestrated treatment is a minimally invasive and effective method to treat high-risk patients with acute Stanford type A aortic dissection.