1.Early clinical effects of phacoemulsification cataract surgery with implantation of Acrysof IQ Restor multi-focal toric lens
Xiangfei CHEN ; Yan LU ; Yuhua SHI ; Chunyan XUE ; Yin CHEN ; Liping YANG ; Zhenping HUANG
Journal of Medical Postgraduates 2014;(6):600-604
Objective Acrysof IQ Restor multifocal toric intraocular lens ( IOL) is a new product , which allows a single sur-gical procedure for presbyopia correction and corneal astigmatism management .This study was to evaluate the early clinical effects of phacoemulsification cataract surgery with implantation of a diffractive multifocal toric IOL . Methods We retrospectively analyzed 7 cases (9 eyes) of corneal astigmatism ≥1.0 diopter (D) treated by phacoemulsification with implantation of an Acrysof IQ Restor toric IOL.The patients were followed up for 3 months for observation of uncorrected distance visual acuity ( UDVA) , best corrected distance visual acuity ( CDVA) , uncorrected near visual acuity ( UNVA ) , best corrected near visual acuity ( CNVA ) , spherical equivalent (SE) refraction, focal depth, residual astigmatism, rotational stability of the IOL, contrast sensitivity (CS), and spectacle independ-ence preoperatively and at 1 week, 1 month, and 3 months after operation . Results At 3 months after surgery , the UDVA ( log-MAR), CDVA, UNVA, and CNVA were 0.07 ±0.10, 0.02 ±0.11, 0.12 ±0.06, and 0.08 ±0.07, respectively, with an SE re-fraction within ±0.50 D of the attempted spherical correction in 8 eyes (88.9%) and a focal depth of (5.32 ±1.78) D.The residual astigmatism at 3 months was significantly reduced as compared with the baseline ([0.25 ±0.28] vs [1.55 ±0.39] D, P<0.05), but showed no statistically significant differences from the preoperative an-ticipated residual astigmatism (P>0.05).At 3 months, the mean IOL axis rotation was (3.11 ±1.61)°and CS was remarkably im-proved ( P<0 .05 ) , while CS with or without glare was not significantly different from that at 1 month at all spatial frequencies ( P>0.05) except at 18.0 cpd (P<0.05). Conclusion Implantation of the Acrysof IQ Restor multifocal toric IOL provides excellent overall quality of vision, spectacle independence, visual quality, and rotational stability for patients with cataract and corneal astigmatism.
2.Production of anti-human c-kit monoclonal antibodies by direct intra-spleen injection of DNA vaccine
Lin SHI ; Dashui HE ; Chunling FENG ; Xiangfei YUAN ; Hao QU ; Lihua HUANG ; Liyan ZHANG ; Dongmei WANG ; Yi ZHANG ; Yuguang ZHANG
Chinese Journal of Immunology 2001;0(07):-
Objective:To prepare anti-human c-kit monoclonal antibody(McAb) by genetic immunization in spleen,and to determine practicability of these means to produce McAbs based on the biological activity of anti-human c-kit antibody.Methods:Recombinant plasmid pcDNA3.1/c-kit extracellular domain was constructed by molecular cloning techniques,and was used to immunize BALB/c mice in spleen directly to prepare mAb against human c-kit by routine hybridoma technique.FASC、fluorescence microscope and Western blot were utilized to identify the prepared antibody.Results:c-kit extracellular region was cloned and insert pcDNA3.1 plasmid successfully.Three hybridoma cell lines 6C4、2C5 and 5D5 that secrete anti-human c-kit McAbs were obtained after using intra-spleen immunization with a DNA vaccine.The isotypes of these three antibodies were all IgM,and the epitopes were different with each other.Conclusion:The method of genetic immunization into spleen can be used to prepare anti-human c-kit monoclonal antibodies.
3.The Killing Effects and Preliminary Mechanism of Natural Plant-derived Antimicrobial Solution(PAMs)to Human Liver Cancer HEPG-2 Cells
Jinyi QIU ; Jiaming HUANG ; Yijie ZHOU ; Rongkun DOU ; Zhenfei BI ; Yalan YANG ; Yinsong DONG ; Danzhou XIANGFEI ; Canquan MAO
Progress in Modern Biomedicine 2017;17(26):5011-5016
Objective:In this study,a series of experiments were conducted to research the mechanism of anticancer and preliminary molecular effects of PAMs on the HEPG-2 cancer cells.Methods:Morphological observation and MTT assay were used to explore the inhibition and killing effect of PAMs acting on HEPG-2.AO/EB staining and Annexin V-FITC/PI staining were employed to observe the apoptosis of HEPG-2 treated with PAMs.The expression level of Foxm1,bcl-2 and others genes in HEPG-2 cells were detected by using qRT-PCR and western blot.Wound healing and transwell experiments determined if PAMs can inhibit the migration of HEPG-2.Results:PAMs can inhibit and kill HEPG-2 cells in time and dose-dependent manners,and the cytotoxic effects were closely related to the cell apoptosis.The mRNA expression of foxm1,bcl-2 and surviving gene were remarkably decreased in HEPG-2 cells after the treatment of PAMs.PAMs decreased the FoXM1 protein expression in HEPG-2 cells,while up-regulating thep53 protein expression.,and it could also inhibit the migration of cancer cells.Conclusions:The possible molecular mechanism for the killing of HEPG-2 cancer cells by PAMs was proposed.By down-regulating the expression of foxm1 and up-regulating the expression of p53,the transcriptional expression of their downstream target genes survivin and bcl-2 was inhibited or reduced,hence enhancing the cancer cell apoptosis.This study provides an important foundation for the development of anti-cancer Chinese folk medicine based on PAMs.
4.Evaluation the safety and efifcacy of corsair microcatheterin the recanalization for coronary chronic total occlusion with transradialantegrade approach
Lei GE ; Hao LU ; Yuxiang DAI ; Chenguang LI ; Qing QIN ; Jianying MA ; Yizhe WU ; Li SHEN ; Xiangfei WANG ; Qibing WANG ; Yan YAN ; Bing FAN ; Dong HUANG ; Kang YAO ; Feng ZHANG ; Juying QIAN ; Junbo GE
Chinese Journal of Interventional Cardiology 2014;(6):349-352
Objective The aim of this study was to evaluate the safety and efficacy of 135 cm Corsair microcatheter inpercutaneous coronary intervention (PCI) for coronary chronic total occlusion (CTO) with antegrade approach via radial artery. Methods From June 2010 to February 2014, a total of 81 patients with CTO lesions treated with 135cm Corsair microcatheter (Asahi Intec Co, Japan) and transradial antegrade approach was enrolled in this study. The success rate of CTO-PCI, the rate of Corsair microcatheter crossing the CTO lesions and the number of balloon catheters utilization were retrospectively analyzed. Unique complications related to the Corsair microcatheter were also documented. Results Success recanalization of CTO were achieved in 73 (90.1%) patients. Crossing the CTO body with Corsair microcatheter was found in 56(84.8%) patients. The number of balloon utilized after Corsair microcatheter crossing the CTO was much lower than that of patients who Corsair microcatheter failed to cross (1.3±0.6 per patient versus 2.8±1.2per patient, P < 0.05). The success recanalization rate of combined using Fielder XT guidewire with Corsair microcatheter was 51.5%. There was no complications related to Corsair microcatheter during the index procedure, no major adverse cardiac events during in-hospital clinical follow-up. Conclusions Corsair microcatheter was safe and effective in the recanalization for CTO with transradialantegrade approach. It can simplify the CTO-PCI procedure and reduce the number of balloon catheters.
5.Effect of new simple breathing apparatus on oxygen therapy in patients with severe and critical coronavirus disease 2019
Fuzhou HUA ; Xifeng WANG ; Xiangfei HUANG ; Fan XIAO ; Gen WEI ; Jun YING ; Lian GUO ; Qian HU ; Xianju HE ; Shuchun YU ; Guohai XU ; Jianjun XU
Chinese Critical Care Medicine 2020;32(7):864-868
Objective:To make a new simple respirator and observe the oxygen therapy effect of the respirator on patients with severe and critical coronavirus disease 2019 (COVID-19).Methods:Based on the infectivity and hospital requirements of COVID-19, a new simple respirator was designed by the medical staff of the Department of Anesthesiology of the Second Affiliated Hospital of Nanchang University, which was applied on the 22 patients with severe and critical COVID-19 who needed oxygen therapy admitted to the Cancer Center of Tongji Medical College of Huazhong University of Science and Technology from February 15th to March 15th in 2020. The new simple respirator contained two National Utility Model Patents (a respirator: ZL 2015 2 0410623.6, a fluid switch and oxygen suction device: ZL 2017 2 0873509.6), which was mainly composed of anesthesia mask and filter, L-shaped connecting tube, soft breathing bladder, connecting tube and elastic fixing belt. When in use, the anesthesia mask was fixed to the patient's mouth and nose with elastic straps, the connecting tube was inserted into the oxygen meter interface, the oxygen flow was adjusted to 6-10 L/min, and the L-shaped connecting tube was opened immediately after the soft breathing bag was full. The carbon dioxide and excess oxygen in the body was discharged from exhaust port. The oxygen flow was lowered to 2-3 L/min, the patient's respiratory rate (RR) was observed through the soft breathing bag fluctuations, and the oxygen flow was adjusted at any time. The changes of pulse oxygen saturation (SpO 2), RR and heart rate (HR) before and after application of new simple respirator were observed, and the blood gas test results of part of the patients were collected. Results:Twenty-two patients with severe and critical COVID-19 had significantly higher SpO 2 at 10 minutes after application of the new simple ventilator than before application (0.994±0.007 vs. 0.952±0.017, P < 0.01), and RR was significantly lower than that before application (times/min: 27.59±3.63 vs. 29.64±3.81, P < 0.01); after 1 day of application, each index was further improved. All 13 patients who received blood gas analysis indicated no carbon dioxide accumulation. Conclusions:The new simple respirator can significantly improve the oxygen therapy effect of patients with severe and critical COVID-19. At the same time, 2019 novel coronavirus (2019-nCoV) can be filtered through the filter to reduce the formation of aerosol and protect the medical staff and patients.
6.Monitoring of cerebrospinal fluid dynamics in a model of brain herniation induced by acute intracranial hypertension by PC cine MRI
Jianguo ZHOU ; Xiaoling ZHU ; Wupeng WEI ; Lixuan HUANG ; Yongbiao FENG ; Ling ZHANG ; Xiangfei MA ; Weixiong LI ; Jianfeng ZHANG ; Hesheng OU ; Huamin TANG
Chinese Journal of Emergency Medicine 2019;28(5):584-590
Objective To explore the monitoring of cerebrospinal fluid (CSF) dynamics in a model of brain herniation induced by acute intracranial hypertension in Guangxi Bama-Mini pigs by phasecontrast cine magnetic resonance imaging (PC cine MRI).Methods Femoral artery blood were extracted from 10 pigs,and injected into the frontal and temporal parietal lobe to make a model of brain herniation induced by acute intracranial hypertension.The mean arterial blood pressure (MAP),intracranial pressure (ICP),and cerebral perfusion pressure (CPP) were monitored.Routine T1WI,T2WI,coronal,sagittal and cerebrospinal fluid flow sequence (fast PC cine slice) which positioned on the cervical 3 (C3) vertebral body as the center and perpendicular to the spinal scans were performed on all experimental animals before and after blood injection with 3.0T Magnetic Resonance Imaging.The ICP,MAP,CPP,the absolute values of CSF peak flow velocity and the absolute value of carotid peak flow velocity before and after blood injection were compared.Results The ICP,MAP,CPP,and the absolute value of CSF peak flow velocity before injection of autologous arterial blood were statistically significant as compared with those after blood injection [(6.80±2.044) mmHg vs (52.20±1.619) mmHg,(76.80±7.068) mmHg vs (142.80±12.399) mmHg,(70.00±6.074) mmHg vs (90.50±12.250) mmHg,and the absolute value of CSF peak flow velocity was (243.20±77.671) mm/s vs (201.40±55.482) mm/s,respectively,P<0.01].The absolute value of the peak velocity of the carotid artery before blood injection was not statistically significant compared with that after blood injection [(876.80±239.908) mm/s vs (799.40±241.829) mm/s,P>0.05].Conclusion After the formation of brain herniation induced by acute intracranial hypertension,the CSF flow in the C3 level spinal canal showed a low dynamic change,and the CSF flow velocity waveform was disordered and malformed.The non-invasive measurement of CSF dynamics by PC cine MRI can provide an important basis for the change of CSF dynamics in the model of brain herniation induced by acute intracranial hypertension,and provide a theoretical basis for further research on damage control neurosurgery in the future.
7.Liver transplantation for irresectable hilar cholangiocarcinoma.
Yanhua LAI ; Jiahong DONG ; Weidong DUAN ; Qiang YU ; Xiangfei MENG ; Sheng YE ; Dongxin ZHANG ; Zhiqiang HUANG
Chinese Journal of Surgery 2014;52(11):839-844
OBJECTIVETo evaluate the outcome of patients with irresectable hilar cholangiocarcinoma undergoing orthotopic liver transplantation (OLT) and to identify the prognostic factors that could influence survival.
METHODSThe data of 18 patients who underwent OLT for irresectable hilar cholangiocarcinoma between June 2003 and October 2010 were analyzed retrospectively. There were 12 male and 6 female cases with median of 52 years(range from 34 to 65 years).Fifteen patients underwent modified piggyback liver transplantation, 2 patients underwent classical orthotopic liver transplantation and 1 patient underwent living donor liver transplantation. Data were evaluated regarding tumor size, pathologic stage, overall survival, recurrence rates and prognostic factors.
RESULTSOLT with lymphadenectomy was received by 18 patients with hilar cholangiocarcinoma. Median time until tumor recurrence was 20.5 months(range from 6.0 to 33.0 months). Seventeen patients died during follow-up.Of these, 14 patients died from recurrent or metastatic diseases, 2 patients died from multiple organ dysfunction syndrome during peri-operative period, and one patient died from other cause. The median survival time was 29.5 months(range from 3.0 to 84.0 months). The overall survival rate and recurrence-free survival rate at 1, 3, and 5 year were 16/18, 8/18, 1/18 and 13/18, 2/18, 1/18, respectively.Lymph node metastases had a statistically significant negative impact on overall survival. The 1, 3, and 5 year survival rates were 6/7, 1/7,0 and 10/11, 7/11, 1/11 (P < 0.05) in lymph node-positive and lymph node-negative patients.
CONCLUSIONSAcceptable survival rates can be achieved by OLT for irresectable hilar cholangiocarcinoma without lymph node metastases.Strict patient selection plus multimodal chemoradiation therapy prior to OLT are recommend for patients with lymph node metastases.
Adult ; Aged ; Bile Duct Neoplasms ; surgery ; Bile Ducts, Intrahepatic ; surgery ; Cholangiocarcinoma ; surgery ; Female ; Humans ; Liver Transplantation ; Male ; Middle Aged ; Neoplasm Recurrence, Local ; Prognosis ; Retrospective Studies ; Survival Rate ; Treatment Outcome
8.Clinical application of precise liver surgery techniques for donor hepatectomy in living donor liver transplantation.
Yanhua LAI ; Jiahong DONG ; Email: DONGJH301@163.COM. ; Weidong DUAN ; Sheng YE ; Wenbin JI ; Jianjun LENG ; Ying LUO ; Qiang YU ; Xiangfei MENG ; Dongxin ZHANG ; Bin SHI ; Zhiqiang HUANG
Chinese Journal of Surgery 2015;53(5):328-334
OBJECTIVETo evaluate the effect of techniques of precise liver surgery for donor hepatectomy in living donor liver transplantation.
METHODSEighty-nine donors aged from 19 to 57 years were performed by the same surgical team from June 2006 to December 2013 in Chinese People's Liberation Army General Hospital.Individualized surgical program were developed according to preoperative imaging examination and hepatic functional reserve examination. The evaluation included liver function, liver volume, vascular anatomy and bile duct anatomy. According to the results after the operation, preoperative evaluation accuracy, postoperative donor liver function and postoperative complications were analyzed. ANOVA analysis was used to compare the difference of graft volume by two-dimensional, three-dimensional calculation method and actual postoperative graft weight. Pearson correlation test and linear regression analysis were used to verify the correlation between the estimated graft volume each method and actual graft postoperative weight.
RESULTSAll the 89 cases operation protocol as following, there were 5 cases with left lateral lobe graft, 10 cases with left lobe liver graft, 74 cases with right lobe graft. There were 59 cases with middle hepatic vein (MHV) harvested, and 30 cases without MHV. The mean graft volume by two-dimensional, three-dimensional calculation method and actual postoperative graft weight were (656.2±134.1) ml, (631.7±143.2) ml and (614.5±137.7) ml respectively. ANOVA analysis results showed that there were no statistically significant difference in the three methods (P>0.05). Compared to the actual postoperative graft weight, the average error rate of the two methods were 7.9% and 5.3% respectively. Pearson correlation test showed the graft volume calculated by two-dimensional and three-dimensional methods had a significantly positive correlation with actual graft weight (r=0.821, 0.890, P<0.01) and linear regression analyze showed the R2 were 0.674 and 0.792, respectively. The accuracy rate of preoperative evaluation about portal vein, hepatic vein, hepatic artery and bile duct were 100%, 100%, 97.8% and 95.5%, respectively. The preoperative plan and postoperative practical scheme coincidence rate was 95.5%. Overall donor complication rate was 7.4%. All donors were alive. Sixteen donors received right lobe hepatectomy with gallbladder preserved had a good liver function and gallbladder function.
CONCLUSIONThrough the precise preoperative evaluation, surgical planning, fine operation and excellent postoperative management, precise liver surgery technique can ensure the safety of donor in living donor liver transplantation.
Adult ; Bile Ducts ; Body Weight ; Hepatectomy ; methods ; Hepatic Artery ; Hepatic Veins ; Humans ; Linear Models ; Liver Transplantation ; methods ; Living Donors ; Middle Aged ; Portal Vein ; Postoperative Complications ; Postoperative Period ; Young Adult