1.Sequence analysis of HIV-1 strains from 2 mother-to-child cases
Jing ZHANG ; Tongzhan WANG ; Xiangdong YOU
Chinese Journal of Infectious Diseases 2000;0(02):-
Objective To study the origin of HIV-1 strains from 2 mother-to-child cases. Method DNA fragments of HIV-1 gag gene were amplified by nested PCR from the 4 target persons, and the amplified region were sequenced. Results The sequence of the specified fragment from all persons were analyzed and the strains were belonged to subtype A/E, while the sequence between mother's and child's is highly homologous. Conclusion 2 children were infected by mother-to-child transmission.
2.Study on integrin-mediated albumin microbubbles adherence to activated leukocytes
Ying ZHOU ; Jiang SHAN ; Yili LIU ; Xiangdong YOU ; Qinghu L
Chinese Journal of Pathophysiology 2000;0(11):-
AIM:To investigate the mechanism responsible for albumin microbubbles adherence to activated leukocytes. METHODS: In vitro studies were performed in which activated or nonactivated leukocytes were incubated with albumin microbubbles and observed under microscopy. The suspensions of leukocytes and microbubbles which contained or absented of integrins were analyzed with flow cytometry.RESULTS: A minimum of 50 cells were identified under transillumination. 5 min after microbubbles were incubated with leukocytes, the number of cells interacting with microbubbles was greater for activated cells than for nonactivated cells(20 30?2 67 vs 4 50?1 43, P
3.The size of thyroid nodules contributing to the accuracy of fine-needle aspiration cytology
Bin LU ; Xiangdong YOU ; Pintong HUANG ; Guoqiang MO ; Minqiang PAN
Chinese Journal of Ultrasonography 2014;23(9):778-781
Objective To evaluate the association of the size of thyroid nodules and accuracy of fineneedle aspiration cytology in diagnose of thyroid nodules.Methods 691 thyroid nodules in 630 patients pathologically confirmed were retrospectively analyzed in our hospital.All imaging data of preoperative ultrasound-guided FNAC were collected in our review.Yields of FNAC were divided into six levels according to the classification criteria of the Bethesda system(level Ⅰ,insufficient material or nondiagnosed;level Ⅱ,benign ; level Ⅲ,atypical hyperplasia; level Ⅳ,follicular neoplasm ; level Ⅴ,suspicious for malignancy; level Ⅵ,malignant),>level Ⅳ was the malignant cytologic criteria for diagnosis of thyroid nodules.According to the maximal diameter of thyroid nodules,the nodules were divided into group A(L≤0.5 cm),group B(0.5 cm<L<1.0 cm) and group C(L≥1.0 cm).Postoperative pathologic results were taken as the gold standard.Results Of 691 nodules,there were 176(25.47%),298(43.13%) and 217(31.40%) in group A,group B and group C respectively.Among the three groups,accuracy of ultrasound-guided FNAC in group B (90.94 %) was higher than in group A(80.11%) and group C(83.41 %),with statistically significant(P <0.05).There was not statistically different between group A and group C(P >0.05).The specificity,positive predictive value and negative predictive value were not statistically different among three groups(P >0.05).Conclusions The size of thyroid nodules was partly associated with accuracy of ultrasound-guided FNAC.
4.Clinical study of left ventricular untwisting motion by peak ventricular apical rotation velocity during early diastole
Ri JI ; Xiangdong YOU ; Zhaoxia PU ; Lei YU ; Xiatian LIU ; Xiaofeng BAO
Chinese Journal of Ultrasonography 2009;18(9):745-747
Objective To evaluate peak left ventricular(LV) apical rotation velocity during early diastole by speckle tracking echocardiography in normal peopleand patients with myocardial hypertrophy because of hypertension. Methods Two dimensional images of left basal and apical ventricular short axis view were recorded in 20 healthy people and 20 patients with hypertension and left ventricular hypertrophy(LVH). Rotation velocity-time curves of six segments in LV apex and base were obtained using Qlab software. The peak rotation velocity in early diastole of LV apex(A-Vel) and base (B-Vel) were acquired through Excel software. Results In LVH group,A-Vel was significantly decreased(P<0. 05) while B-Vel appeared no difference (P = 0.58) compared with healthy individuals. Conclusions Peak LV apical rotation velocity in early diastole can evaluate the change of LV diastolic function in patients with hypertension and LVH.
5.Practice and reflection on the international remote pathology consultation
Xiangdong YOU ; Jianan WANG ; Wei LI ; Meijuan LAN ; Mingli YANG ; Xu FANG ; Guofeng WANG ; Fangmin GE
Chinese Journal of Hospital Administration 2011;27(8):613-615
Justified the necessity of remote pathology consultation in China, and described the basic approach of such consultation in terms of the conditions, organizational framework, specialists and consultation process of the hospital. on the basis of benefit in pationts, the consultation helps the development of the pathology department and other specialist departments at the same time, builds initially a pathology quality control system, and accelerates the multi-discipline diagnosis and treatment approach. Expect to encourage contemplation on international remote pathology consultation in an effort to improve such a practice for the benefit of patients.
6.Preoperative biopsy in the treatment of gastric mucosal lesions by endoscopic submucosal dissection
You ZHANG ; Enqiang LINGHU ; Zhongsheng LU ; Hong DU ; Xiangdong WANG ; Jiangyun MENG ; Hongbin WANG
Chinese Journal of Digestive Endoscopy 2012;29(3):151-154
ObjectiveTo evaluate preoperative biopsy in the treatment of gastric mucosal lesions by endoscopic submucosal dissection (ESD).MethodsClinical data of 195 patients diagnosed as having gastric intraepithelial neoplasia (GIEN) or early cancer by preoperative biopsy were retrospectively analyzed.The discrepancy between endoscopic biopsies and pathological diagnosis after ESD were studied.ResultsThe overall consistency rate between preoperative biopsies and postoperative pathological diagnosis was 93.8% (183/195) and complete consistency rate was 50.8% (99/195).For low-grade and highgrade gastric intraepithelial neoplasia ( LGIEN),the complete consistency rates were 49.4% (42/85)and 38.0% (30/79),respectively,which were not different ( P > 0.05 ).For early cancer it was 87.1%(27/31 ),which was significantly higher than those in the LGIEN group and HGIEN group ( P < 0.05 ).Post-ESD diagnosis was more severe than biopsy in 66 patients (33.8%,66/195 ),including 36 LGIEN (42.4%,36/85) and 30 HGIEN (38.0%,30/79).Final pathological diagnosis was milder than biopsy in 18 patients (9.2%,18/195),i.e.14 HGIEN (17.7%,14/79) and 4 early cancer (12.9%,4/31).Gastritis was diagnosed in 12 patients (6.2%,12/195),i.e.7 LGIEN (8.2%,7/85) and 5 HGIEN (6.3%,5/79).ConclusionPreoperative biopsy is insufficient for accurate diagnosis of gastric mucosal lesions,but facilitates resection of gastric mucosal lesions by ESD.
7.Application of the binary regression mode in analyzing the ultrasonographic features of solid thyroid micronodules
Yuemingming JIANG ; Pintong HUANG ; Nan SU ; Shengmin ZHANG ; Libin CHEN ; Youfeng XU ; Xiangdong YOU
Chinese Journal of Ultrasonography 2014;23(8):675-678
Objective To apply the binary Logistic regression model and evaluate the value of grey scale ultrasonography(US),ultrasond elastography(UE) and contrast-enhanced ultrasound(CEUS).Methods US,UE and CEUS were performed in 130 patients with 142 solid thyroid micronodules (the largest diameter less than 10 mm).Pathology was followed up as golden diagnosis criteria.A Logistic model on the basis of ultrasonographic features was obtained.A receiver operating characteristic(ROC) curve was used to assess the performance of Logistic model.Results Four ultrasonic indexes were finally entered into the Logistic regression model including microcalcification,acpect ratio,advanced CEUS mode and elasticity score.The percentage correction of prediction was 92.1% (129/142),the area under the ROC curve was 0.944.Conclusions The multivariate analysis model of binary Logistic regression can describe and analyze the process of differential diagnosis of malignant and benign solid thyroid micronodules by ultrasonography,and select out the valuable indexes for differential diagnosis.
8.Preliminary evaluation of transesophageal echocardiography in percutaneous edge-to-edge repair of mitral regurgitation
Zhaoxia PU ; Lei YU ; Xiangdong YOU ; Xianbao LIU ; Jian'an WANG ; Wei HE ; Pintong HUANG
Chinese Journal of Ultrasonography 2014;23(10):842-846
Objective To explore the preliminary evaluation of transesophageal echocardiography in percutaneous edge-to-edge repair of mitral regurgitation.Methods Ten consecutive patients were treated with percutaneous edge-to-edge repair of mitral regurgitation using the MitraClip system.All of them had moderate-severe (n =1) or severe (n =9) central MR and high operative risk.MitraClip implantation performed under echocardiographic and fluoroscopic guidance in general anaesthesia.Preoperative and postoperative immediate echocardiographic data were prospectively collected.Results All operations succeed with one MitraClip implanted to 5 patients and two MitraClips implanted to 5 patients.Postoperative immediate echocardiography observed MR reduction,6 cases to mild,2 cases to mild-to-moderate and 2 cases to moderate.No complications occurred in all patients,such as Clip off,pericardial effusion/tamponade,or mitral valve damage.Conclusions Echocardiography guarentees the success of MitraClip based transcatheter mitral valve repair operations with safety and effectiveness.
9. Comparison of aortic annular diameter defined by different measurement mordalities before transcatheter aortic valve implantation
Ruixiang QI ; Xiangdong YOU ; Zhaoxia PU ; Qian YANG ; Zhaoxu HUANG ; Liming ZHOU ; Pintong HUANG
Chinese Journal of Cardiology 2017;45(5):409-414
Objective:
To compare aortic annular diameter measured by transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT) in patients with severe aortic stenosis, and to evaluate the impact on selection of prosthetic valve type in transcatheter aortic valve implantation (TAVI).
Methods:
Clinical data of 138 patients with severe aortic stenosis referred for TAVI between January 2014 and June 2016 in our hospital were retrospectively analyzed.The difference of aortic annular diameter measured by TTE, TEE, and MSCT were compared.TTE was performed after TAVI to evaluate the accuracy of measurement before TAVI.
Results:
(1) Aortic annular diameter was (23.37±2.22) mm by TTE and (23.52±1.70) mm by TEE (
10.Preoperative gross classification of gastric adenocarcinoma: Comparison of double contrast-enhanced ultrasound and multi-detector row CT
Caoxin YAN ; Pintong HUANG ; Weihui SHENTU ; Minqiang PAN ; Xiangdong YOU ; Yanbin TAN ; Liuhong WANG ; Xiaoli JIN
Chinese Journal of General Surgery 2018;33(1):20-24
Objective To compare the accuracy of double contrast-enhanced ultrasound (DCEUS) and multi-detector row CT (MDCT) in determining the gross classification in patients with gastric carcinoma (GC) preoperatively.Methods 239 patients with GC proved by endoscopic biopsy were included.DCEUS (intravenous microbubbles combined with oral contrast-enhanced ultrasound) and MDCT were performed preoperatively.The diagnostic accuracy of DCEUS and MDCT in determining gross classification was calculated and compared.Results The overall accuracy of DCEUS in determining the gross appearance of GC was higher than that of MDCT (85% vs.80%,P < 0.05);there was no significant difference in accuracy between DCEUS and MDCT for Borrmann Ⅰ and Ⅳ classification of AGC (x2 =1.175,P =0.323 for type Ⅰ;x2 =2.171,P =0.141 for type Ⅳ);the accuracy of DCEUS for EGC,Borrmann Ⅱ and Ⅲ classification of GC was higher than that of MDCT (x2 =16.307,P =0.000 for EGC;x2 =39.950,P =0.000 for type Ⅱ;x2 =35.770,P =0.000 for type Ⅲ).Conclusion DCEUS is valuable in determining gross typing of gastric adenocarcinoma preoperatively.