AIM: To establish a method for the determination of ephedrine hydrochloride in Juyuanzhike Tablets (Radix Platycodonis,Radix Polygalae,ephedrinelydrochloride,etc.). METHODS :Ephedrine hydrochloride in Juyuanzhike Tablets were determined by HPLC. RESULTS : The linear range was 0.2~1.6 ?g,r =0.9999.The average recovery was 97.7% and RSD was 0.58%,respectively. CONCLUSION : The method is simple,feasible and reproducible. It can be used for the quality control of Juyuanzhike Tablets.
2.Verification of positioning accuracy of MLC leaves of 7 medical electronic linear accelerators in IMRT in Sichuan province
Ran LIU ; Qiao MA ; Deming LIU ; Xiangdong LIAO
Chinese Journal of Radiological Medicine and Protection 2019;39(2):141-144
Objective To verify the accuracy of multi-leave collimators (MLC) leaves position in intensity modulated radiation therapy (IMRT) using radiochromic films.Methods 7 medical electronic linear accelerators of Varian,Elekta or Siemens design were chosen.25 cm× 25 cm films were put on 30 cm×30 cm×3.0 cm homogeneous solid phantom and covered with a 2.0 cm thick of homogeneous solid phantom.The CT scanned images were transmitted to TPS for plan preparation.A 5 strip picket fence pattern was formed by MLC leaf,each 3 cm long and 0.6 cm wide,with 3.0 cm wide strip separation.At the maximum dose point,the SSD was 100 cm,with 250 MU per strip.After exposure,the films were transmitted to the dosimetry laboratory at IAEA for measurement and calculation.Results For 6 of 7 accelerators chosen,the differences of film-measured and TPS-planned MLC leaf position for every fence were within ± 0.5 mm as required by IAEA,and the other one not consistent with the requirements.The difference of film-measured MLC leaf position between each pair and all pair for 7 accelerators were within ± 0.5 mm,in line with IAEA's requirements.The differences of film-measured MLC leaf actual width were within 0.75 mm,as required by IAEA,for 6 accelerators and-0.8 mm for the other one,not consistent with the IAEA requirements.The standard deviations of film-measured MLC leaf actual width for all pairs for 6 accelerators were <0.3 mm,in line with IAEA requirements,but 0.4 mm for the other one,not consistent with IAEA requirements.Conclusions It is simple,fast and accurate to use radiochromic films for verification of the accuracy of MLC leaf position in IMRT.Therefore it is advisable to widely use radiochromic films in IMRT clinical practice.
3.Expert consensus on the diagnosis and treatment of severe and critical coronavirus disease 2019.
You SHANG ; Jianfeng WU ; Jinglun LIU ; Yun LONG ; Jianfeng XIE ; Dong ZHANG ; Bo HU ; Yuan ZONG ; Xuelian LIAO ; Xiuling SHANG ; Renyu DING ; Kai KANG ; Jiao LIU ; Aijun PAN ; Yonghao XU ; Changsong WANG ; Qianghong XU ; Xijing ZHANG ; Jicheng ZHANG ; Ling LIU ; Jiancheng ZHANG ; Yi YANG ; Kaijiang YU ; Xiangdong GUAN ; Dechang CHEN
Chinese Medical Journal 2022;135(16):1913-1916
Humans
;
COVID-19
;
Consensus
;
SARS-CoV-2
;
China