1.Long-term therapeutic efficacy and prognosis analysis of complex high-risk coronary heart disease patients undergoing elective percutaneous coronary intervention with extracorporeal membrane oxygenation combined with intra-aortic balloon pump
Tian-Tong YU ; Shuai ZHAO ; Yan CHEN ; You-Hu CHEN ; Gen-Rui CHEN ; Huan WANG ; Bo-Hui ZHANG ; Xi ZHANG ; Bo-Da ZHU ; Peng HAN ; Hao-Kao GAO ; Kun LIAN ; Cheng-Xiang LI
Chinese Journal of Interventional Cardiology 2024;32(9):501-508
Objective We aimed to compare the efficacy and prognosis of percutaneous coronary intervention(PCI)in complex and high-risk patients with coronary heart disease(CHD)treated with extracorporeal membrane oxygenation(ECMO)combined with intra-aortic balloon pump(IABP)assistance,and explore the application value of combined use of mechanical circulatory support(MCS)devices in complex PCI.Methods A total of patients who met the inclusion criteria and underwent selective PCI supported by MCS at the Department of Cardiology,the First Affiliated Hospital of the Air Force Medical University from January 2018 to December 2022 were continuously enrolled.According to the mechanical circulatory support method,the patients were divided into ECMO+IABP group and IABP group.Clinical characteristics,angiographic features,in-hospital outcomes,and complications were collected.The intra-hospital outcomes and major adverse cardiovascular events(MACE)at one month and one year after the procedure were observed.The differences and independent risk factors between the two groups in the above indicators were analyzed.Results A total of 218 patients undergoing elective PCI were included,of which 66 patients were in the ECMO+IABP group and 152 patients were in the IABP group.The baseline characteristics of the two groups of patients were generally comparable,but the ECMO+IABP group had more complex lesion characteristics.The proportion of patients with atrial fibrillation(6.1%vs.0.7%,P=0.030),left main disease(43.9%vs.27.0%,P=0.018),triple vessel disease(90.9%vs.75.5%,P=0.009),and RCA chronic total occlusion disease(60.6%vs.35.5%,P<0.001)was higher in the ECMO+IABP group compared to the IABP group.The proportion of patients with previous PCI history was higher in the IABP group(32.9%vs.16.7%,P=0.014).There was no statistically significant difference in the incidence of in-hospital complications between the two groups(P=0.176),but the incidence of hypotension after PCI was higher in the ECMO+IABP group(19.7%vs.9.2%,P=0.031).The rates of 1-month MACE(4.5%vs.2.6%,P=0.435)and 1-year MACE(7.6%vs.7.9%,P=0.936)were comparable between the two groups.Multivariate analysis showed that in-hospital cardiac arrest(OR 7.17,95%CI 1.27-40.38,P=0.025)and after procedure hypotension(OR 3.60,95%CI 1.10-11.83,P=0.035)were independent risk factors for the occurrence of 1-year MACE.Conclusions Combination use of ECMO+IABP support can provide complex and high-risk coronary heart disease patients with an opportunity to achieve coronary artery revascularization through PCI,and achieve satisfactory long-term prognosis.
2.Role of Macrophage Activation and Polarization in Myocardial Fibrosis and Intervention of Traditional Chinese Medicine
Kunpeng YAO ; Huzhi CAI ; Xiang ZHAO ; Ke GONG ; Chuning TIAN ; Yuntao LUO ; Liqi PENG ; Guangyang OU ; Qingyang CHEN ; Xinyu CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(9):272-282
Myocardial fibrosis (MF) is a common pathological manifestation of various heart diseases. Due to the non-renewable nature of myocardial cells, the occurrence of MF represents irreversible damage to the myocardium. Previous studies have suggested that fibroblast-mediated collagen deposition is the main mechanism of MF. Recent studies have found that there is an immune regulation mechanism in the heart itself, and macrophage activation/polarization plays an important role in MF. With the deepening of traditional Chinese medicine research, scholars have found that traditional Chinese medicine can interfere with MF by regulating the renin-angiotensin-aldosterone system (RAAS) system and the inflammatory process, repairing the extracellular matrix, managing oxidative stress, and maintaining the balance of autophagy. This process is closely related to the activation and M1/M2 polarization of macrophages. Throughout the MF process, macrophage activation is beneficial, but excessive activation will be harmful. In the early stage of MF, appropriate M1 macrophage polarization is conducive to activating immunity and removing harmful substances. In the middle and late stages of MF, appropriate M2 macrophage polarization is conducive to remodeling the damaged myocardium. If macrophage activation is excessive/insufficient, or the balance of M1/M2 macrophage polarization is broken, the effect changes from improvement to destruction. Traditional Chinese medicines that regulate the activation/polarization of macrophages have the effects of replenishing Qi and nourishing Yin, as well as regulating Qi and activating blood, but there are also some heat-clearing, dampness-drying, and detoxification products. Therefore, the occurrence of MF may be caused by Qi and Yin deficiency, damp heat accumulation, and Qi stagnation and blood stasis. By summarizing the biological processes involved in macrophage activation/polarization in MF, this paper expounded on the research progress of traditional Chinese medicine in regulating macrophage activation and M1/M2 polarization from different angles to improve MF, so as to provide a reference for the treatment of MF with traditional Chinese medicine.
3.Comparison of clinically relevant factors in bipolar disorder patients with different age of onset
Yan MA ; Xiaoyi TIAN ; Yueqin HUANG ; Zhaorui LIU ; Yongyan DENG ; Liang ZHOU ; Yan LIU ; Bo LIU ; Jie ZHANG ; Yuandong GONG ; Xiang FU ; Qiongxian ZHAO ; Jin LU ; Wannian SHA ; Hao HE ; Zonglin SHEN ; Tingting ZHANG ; Wenming CHEN
Chinese Mental Health Journal 2024;38(1):42-49
Objective:To compare clinical characteristics,treatment patterns and physiological indicators in bipolar disorder(BD)patients with different age of onset.Methods:Totally 380 patients with DSM-5 BD were se-lected in this study.Psychiatrists diagnosed the patients using the Mini International Neuropsychiatric Interview.The clinical information questionnaire and the Global Assessment of Functioning scale were utilized to collected clinical characteristics,treatment status,and physiological indicators.The onset age of BD was divided into 21 and 35 years as cut-off points.Multivariate logistic regression and linear regression were used to analyze related factors.Results:Among the 380 patients with BD,199 cases were early-onset group(52.4%),121 cases were middle-onset group(31.8%),and 60 cases were late-onset group(15.8%).There were 26.6%of patients in the early-onset group in-itially diagnosed as depression,23.1%in the middle-onset group,and 11.7%in the late-onset group.Multivariate analysis revealed that compared to the early-onset group of BD,the middle-onset(OR=2.22)and late-onset(OR=4.99)groups had more risk to experience depressive episodes,and the late-onset group(OR=6.74)had 6.74 times of risk to suffer from bipolar Ⅱ disorder.Additionally,patients in the middle-onset(β=-1.52)and late-on-set(β=-4.29)groups had shorter durations of delayed treatment,and those in the middle-onset(β=-1.62)and late-onset(β=-3.14)groups had fewer hospitalizations.Uric acid levels were lower in both the middle-onset(β=-28.39)and late-onset(β=-31.47)groups,and total cholesterol level was lower in the middle-onset group(β=-0.23).Conclusion:Patients with BD in different age of onset show significant differences in clinical charac-teristics,treatment conditions and physiological indicators.
4.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
5.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
6.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
7.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.

Result Analysis
Print
Save
E-mail