1.Erratum to ‘Genomic biomarkers to predict response to atezolizumab plus bevacizumab immunotherapy in hepatocellular carcinoma: Insights from the IMbrave150 trial’ Clin Mol Hepatol 2024;30:807-823
Sun Young YIM ; Sung Hwan LEE ; Seung-Woo BAEK ; Bohwa SOHN ; Yun Seong JEONG ; Sang-Hee KANG ; Kena PARK ; Hyewon PARK ; Sunyoung S. LEE ; Ahmed O. KASEB ; Young Nyun PARK ; Sun-Hee LEEM ; Michael A. CURRAN ; Ji Hoon KIM ; Ju-Seog LEE
Clinical and Molecular Hepatology 2025;31(2):669-670
2.Effectiveness of Buspirone in Alleviating Anxiety Symptoms in Patients with Depressive Disorder: A Multicenter Prospective Observational Study in Korea
Young Sup WOO ; Won-Seok CHOI ; Jong-Hyun JEONG ; Jonghun LEE ; Do-Hoon KIM ; Jong-Chul YANG ; Se-Hoon SHIM ; Seung-Gul KANG ; Young-Eun JUNG ; Won KIM ; Chi-Un PAE ; Won-Myong BAHK
Clinical Psychopharmacology and Neuroscience 2025;23(1):144-154
Objective:
We aimed to investigate the effectiveness of buspirone as an adjunctive therapy for alleviating anxiety symptoms in patients with depressive disorders who are already taking antidepressants.
Methods:
This was an open-label prospective multicenter non-interventional observational study conducted over 12 weeks. We enrolled 180 patients diagnosed with depressive disorders according to DSM-5 criteria and Hamilton Anxiety Rating Scale (HAMA) scores ≥ 18. Participants were already taking selective serotonin reuptake inhibitors or serotoninnorepinephrine reuptake inhibitors and were prescribed adjunctive buspirone. Efficacy was assessed using HAMA, Hamilton Depression Rating Scale (HAMD), Clinical Global Impression Scale-Improvement, Clinical Global Impression Scale-Severity, Sheehan Disability Scale (SDS), and WHO-5 Well-Being Index.
Results:
The efficacy analysis included 161 patients. HAMA scores decreased significantly from 25.2 ± 6.7 at baseline to 15.4 ± 8.6 at 12 weeks (p < 0.001), whereas HAMD scores decreased from 19.4 ± 4.6 to 12.7 ± 5.7 (p < 0.001).WHO-5 and SDS scores showed significant improvements. The HAMA response rate was 39.1% and the remission rate was 13.7% at 12 weeks. Adverse drug reactions were reported in 3.7% of participants. Subgroup analyses showed no significant differences in treatment response based on buspirone dosage, baseline anxiety/depression severity, or benzodiazepine use.
Conclusion
Adjunctive buspirone therapy effectively improved anxiety symptoms in depressed patients taking antidepressants, regardless of baseline symptom severity or buspirone dosage. The treatment was well-tolerated with few adverse events. Future studies using a control group are needed.
3.Reproducibility of Plasma Biomarker Measurements Across Laboratories:Insights Into ptau217, GFAP, and NfL
Heekyoung KANG ; Sook-Young WOO ; Daeun SHIN ; Sohyun YIM ; Eun Hye LEE ; Hyunchul RYU ; Bora CHU ; Henrik ZETTERBERG ; Kaj BLENNOW ; Jihwan YUN ; Duk L NA ; Hee Jin KIM ; Hyemin JANG ; Jun Pyo KIM ;
Dementia and Neurocognitive Disorders 2025;24(2):91-101
Background:
and Purpose: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer’s disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.
Methods:
Plasma biomarkers were measured using Simoa platforms at both laboratories:the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.
Results:
Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.
Conclusions
Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multicenter studies and underscore their potential for standardized applications in AD research and clinical practice.
4.Clinical Practice Guidelines for Dementia: Recommendations for Cholinesterase Inhibitors and Memantine
Yeshin KIM ; Dong Woo KANG ; Geon Ha KIM ; Ko Woon KIM ; Hee-Jin KIM ; Seunghee NA ; Kee Hyung PARK ; Young Ho PARK ; Gihwan BYEON ; Jeewon SUH ; Joon Hyun SHIN ; YongSoo SHIM ; YoungSoon YANG ; Yoo Hyun UM ; Seong-il OH ; Sheng-Min WANG ; Bora YOON ; Sun Min LEE ; Juyoun LEE ; Jin San LEE ; Jae-Sung LIM ; Young Hee JUNG ; Juhee CHIN ; Hyemin JANG ; Miyoung CHOI ; Yun Jeong HONG ; Hak Young RHEE ; Jae-Won JANG ;
Dementia and Neurocognitive Disorders 2025;24(1):1-23
Background:
and Purpose: This clinical practice guideline provides evidence-based recommendations for treatment of dementia, focusing on cholinesterase inhibitors and N-methyl-D-aspartate (NMDA) receptor antagonists for Alzheimer’s disease (AD) and other types of dementia.
Methods:
Using the Population, Intervention, Comparison, Outcomes (PICO) framework, we developed key clinical questions and conducted systematic literature reviews. A multidisciplinary panel of experts, organized by the Korean Dementia Association, evaluated randomized controlled trials and observational studies. Recommendations were graded for evidence quality and strength using Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology.
Results:
Three main recommendations are presented: (1) For AD, cholinesterase inhibitors (donepezil, rivastigmine, galantamine) are strongly recommended for improving cognition and daily function based on moderate evidence; (2) Cholinesterase inhibitors are conditionally recommended for vascular dementia and Parkinson’s disease dementia, with a strong recommendation for Lewy body dementia; (3) For moderate to severe AD, NMDA receptor antagonist (memantine) is strongly recommended, demonstrating significant cognitive and functional improvements. Both drug classes showed favorable safety profiles with manageable side effects.
Conclusions
This guideline offers standardized, evidence-based pharmacologic recommendations for dementia management, with specific guidance on cholinesterase inhibitors and NMDA receptor antagonists. It aims to support clinical decision-making and improve patient outcomes in dementia care. Further updates will address emerging treatments, including amyloid-targeting therapies, to reflect advances in dementia management.
5.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
6.The effect of a calibrated interproximal brush on proximal plaque removal and periodontal health: a randomized controlled trial
Hye-Jin PARK ; In-Woo CHO ; Hyeon-Seong AHN ; Sung-Jo LEE ; Dae-Young KANG
Journal of Korean Academy of Oral Health 2025;49(1):3-11
Objectives:
To evaluate changes in probing depth, bleeding on probing, and three-dimensional plaque distribution after using an interdental brush for three months.
Methods:
This was a split-mouth design, examiner-blinded, randomized controlled trial. Fifteen patients were randomly assigned to use an interdental brush between their maxillary left or right 1st and 2nd premolar. They were instructed not to use an interdental brush on the opposite side for three months. Probing depth, bleeding on probing, bleeding on using an interdental brush, gingival recession, and plaque distribution were assessed at baseline and after three months.
Results:
After using an interdental brush for three months, 4.26±15.16% of plaque on interdental surfaces decreased. Bleeding on probing and bleeding on using an interdental brush also decreased by 16.67% and 40%, respectively. The size of interdental areas increased by 0.16 mm when using an interdental brush. There were no statistically significant changes in probing depth or gingival recession.
Conclusions
An interdental brush is an effective interdental cleaning aid that reduces interdental plaque and decreases inflammation of interdental soft tissues.
7.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
8.Strategies for Monitoring and Supporting Living Donors in Korea:An Expert Position Paper
Eunjeong KANG ; Hye Young WOO ; Su Young HONG ; Hajeong LEE ; Sangil MIN ; Jongwon HA
Journal of Korean Medical Science 2025;40(10):e33-
Background:
The number of organ transplants in South Korea has increased, with a notable rise in living donor transplants. Ensuring their long-term health and well-being is critical to address potential complications and maintain the success of the transplant programs.
Methods:
A diverse advisory panel, including transplant experts and coordinators, was established to evaluate the follow-up care for living donors. The panel reviewed the results of a brief survey of donors regarding their donation experience, follow-up programs, guidelines, and policies from South Korea and other countries, aiming to identify best practices and recommend improvements.
Results:
The study found that follow-up care for living donors in South Korea is inconsistent and lacks standardization. Significant variability exists in follow-up practices across different institutions, and comprehensive data on donor health pre- and post-donation are scarce. The need for continuous, systematic follow-up, encompassing both medical and psychological support, is emphasized to ensure donor well-being.
Conclusion
Improving follow-up care for living donors is essential. Establishing a national registry and increasing donor advocacy teams are meaningful steps to enhance donor care, ensure long-term health, and maintain ethical standards in organ donation.
9.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
10.A Case Report on Ductal Carcinoma in situ Arising from Axillary Accessory Breast Tissue
Kyung Eun LEE ; Juhee KANG ; Woo Young KANG ; Ok Hee WOO
Journal of the Korean Society of Radiology 2025;86(1):154-159
Accessory breast tissue can appear along the mammary ridge, extending from the axilla to the groin, with the axilla being the most common site. Malignancies arising in accessory breast tissue are rare, representing approximately 0.3%–0.6% of all breast cancer cases.When evaluating accessory breasts, it is essential to apply the same management strategies used for conventionally positioned breasts. This report presents a case of ductal carcinoma in situ originating from accessory breast tissue in the axilla of a 55-year-old woman. The diagnosis was established through a comprehensive assessment involving mammography, ultrasound, and magnetic resonance imaging. Since the axillary accessory breast tissue wasn’t initially included in the routine mammography, we added an axillary tail view to evaluate the extent and morphology of malignant microcalcifications.

Result Analysis
Print
Save
E-mail