1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.A comparative study on efficacy and safety of modified partial stapled hemorrhoidopexy versus conventional hemorrhoidectomy: a prospective randomized controlled trial
Tae Gyu KIM ; Chul Seung LEE ; Dong Geun LEE ; Choon Sik CHUNG ; Seung Han KIM ; Sang Hwa YU ; Jeong Eun LEE ; Gwan Cheol LEE ; Dong Woo KANG ; Jeong Sub KIM ; Gyu Young JEONG
Annals of Coloproctology 2025;41(2):145-153
Purpose:
The long-term outcomes and efficacy of partial stapled hemorrhoidopexy (PSH) compared with those of conventional hemorrhoidectomy (CH) are not fully understood. This study aimed to introduce a modified PSH (mPSH) and compare its clinical efficacy and safety with those of CH.
Methods:
A prospective randomized controlled trial was conducted. This study was performed at a single hospital and involved 6 colorectal surgeons. In total, 110 patients were enrolled between July 2019 and September 2020. Patients were randomly assigned to undergo either mPSH group (n=55) or CH group (n=55). The primary outcome was to compare postoperative average pain and postoperative peak pain using visual analog scale score between the 2 groups.
Results:
The required duration of analgesia was shorter in the mPSH group than in the CH group, although the difference was not statistically significant (P=0.096). However, the laxative requirement duration (P<0.010), return to work (P<0.010), satisfaction score (P<0.010), and Vaizey score (P=0.014) were significantly better in the mPSH group. The average and peak postoperative pain scores were significantly lower in the mPSH group during the 15 days after surgery (P<0.001). The overall complication rate in both groups was 9.1%, with no significant difference between the groups (P=0.867).
Conclusion
The mPSH group demonstrated better improvement in symptoms, lower pain scores, and greater patient early satisfaction after surgery than the CH group. Therefore, this surgical technique appears to be a safe and effective alternative for CH.
3.A comparative study on efficacy and safety of modified partial stapled hemorrhoidopexy versus conventional hemorrhoidectomy: a prospective randomized controlled trial
Tae Gyu KIM ; Chul Seung LEE ; Dong Geun LEE ; Choon Sik CHUNG ; Seung Han KIM ; Sang Hwa YU ; Jeong Eun LEE ; Gwan Cheol LEE ; Dong Woo KANG ; Jeong Sub KIM ; Gyu Young JEONG
Annals of Coloproctology 2025;41(2):145-153
Purpose:
The long-term outcomes and efficacy of partial stapled hemorrhoidopexy (PSH) compared with those of conventional hemorrhoidectomy (CH) are not fully understood. This study aimed to introduce a modified PSH (mPSH) and compare its clinical efficacy and safety with those of CH.
Methods:
A prospective randomized controlled trial was conducted. This study was performed at a single hospital and involved 6 colorectal surgeons. In total, 110 patients were enrolled between July 2019 and September 2020. Patients were randomly assigned to undergo either mPSH group (n=55) or CH group (n=55). The primary outcome was to compare postoperative average pain and postoperative peak pain using visual analog scale score between the 2 groups.
Results:
The required duration of analgesia was shorter in the mPSH group than in the CH group, although the difference was not statistically significant (P=0.096). However, the laxative requirement duration (P<0.010), return to work (P<0.010), satisfaction score (P<0.010), and Vaizey score (P=0.014) were significantly better in the mPSH group. The average and peak postoperative pain scores were significantly lower in the mPSH group during the 15 days after surgery (P<0.001). The overall complication rate in both groups was 9.1%, with no significant difference between the groups (P=0.867).
Conclusion
The mPSH group demonstrated better improvement in symptoms, lower pain scores, and greater patient early satisfaction after surgery than the CH group. Therefore, this surgical technique appears to be a safe and effective alternative for CH.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.A comparative study on efficacy and safety of modified partial stapled hemorrhoidopexy versus conventional hemorrhoidectomy: a prospective randomized controlled trial
Tae Gyu KIM ; Chul Seung LEE ; Dong Geun LEE ; Choon Sik CHUNG ; Seung Han KIM ; Sang Hwa YU ; Jeong Eun LEE ; Gwan Cheol LEE ; Dong Woo KANG ; Jeong Sub KIM ; Gyu Young JEONG
Annals of Coloproctology 2025;41(2):145-153
Purpose:
The long-term outcomes and efficacy of partial stapled hemorrhoidopexy (PSH) compared with those of conventional hemorrhoidectomy (CH) are not fully understood. This study aimed to introduce a modified PSH (mPSH) and compare its clinical efficacy and safety with those of CH.
Methods:
A prospective randomized controlled trial was conducted. This study was performed at a single hospital and involved 6 colorectal surgeons. In total, 110 patients were enrolled between July 2019 and September 2020. Patients were randomly assigned to undergo either mPSH group (n=55) or CH group (n=55). The primary outcome was to compare postoperative average pain and postoperative peak pain using visual analog scale score between the 2 groups.
Results:
The required duration of analgesia was shorter in the mPSH group than in the CH group, although the difference was not statistically significant (P=0.096). However, the laxative requirement duration (P<0.010), return to work (P<0.010), satisfaction score (P<0.010), and Vaizey score (P=0.014) were significantly better in the mPSH group. The average and peak postoperative pain scores were significantly lower in the mPSH group during the 15 days after surgery (P<0.001). The overall complication rate in both groups was 9.1%, with no significant difference between the groups (P=0.867).
Conclusion
The mPSH group demonstrated better improvement in symptoms, lower pain scores, and greater patient early satisfaction after surgery than the CH group. Therefore, this surgical technique appears to be a safe and effective alternative for CH.
7.A comparative study on efficacy and safety of modified partial stapled hemorrhoidopexy versus conventional hemorrhoidectomy: a prospective randomized controlled trial
Tae Gyu KIM ; Chul Seung LEE ; Dong Geun LEE ; Choon Sik CHUNG ; Seung Han KIM ; Sang Hwa YU ; Jeong Eun LEE ; Gwan Cheol LEE ; Dong Woo KANG ; Jeong Sub KIM ; Gyu Young JEONG
Annals of Coloproctology 2025;41(2):145-153
Purpose:
The long-term outcomes and efficacy of partial stapled hemorrhoidopexy (PSH) compared with those of conventional hemorrhoidectomy (CH) are not fully understood. This study aimed to introduce a modified PSH (mPSH) and compare its clinical efficacy and safety with those of CH.
Methods:
A prospective randomized controlled trial was conducted. This study was performed at a single hospital and involved 6 colorectal surgeons. In total, 110 patients were enrolled between July 2019 and September 2020. Patients were randomly assigned to undergo either mPSH group (n=55) or CH group (n=55). The primary outcome was to compare postoperative average pain and postoperative peak pain using visual analog scale score between the 2 groups.
Results:
The required duration of analgesia was shorter in the mPSH group than in the CH group, although the difference was not statistically significant (P=0.096). However, the laxative requirement duration (P<0.010), return to work (P<0.010), satisfaction score (P<0.010), and Vaizey score (P=0.014) were significantly better in the mPSH group. The average and peak postoperative pain scores were significantly lower in the mPSH group during the 15 days after surgery (P<0.001). The overall complication rate in both groups was 9.1%, with no significant difference between the groups (P=0.867).
Conclusion
The mPSH group demonstrated better improvement in symptoms, lower pain scores, and greater patient early satisfaction after surgery than the CH group. Therefore, this surgical technique appears to be a safe and effective alternative for CH.
8.A comparative study on efficacy and safety of modified partial stapled hemorrhoidopexy versus conventional hemorrhoidectomy: a prospective randomized controlled trial
Tae Gyu KIM ; Chul Seung LEE ; Dong Geun LEE ; Choon Sik CHUNG ; Seung Han KIM ; Sang Hwa YU ; Jeong Eun LEE ; Gwan Cheol LEE ; Dong Woo KANG ; Jeong Sub KIM ; Gyu Young JEONG
Annals of Coloproctology 2025;41(2):145-153
Purpose:
The long-term outcomes and efficacy of partial stapled hemorrhoidopexy (PSH) compared with those of conventional hemorrhoidectomy (CH) are not fully understood. This study aimed to introduce a modified PSH (mPSH) and compare its clinical efficacy and safety with those of CH.
Methods:
A prospective randomized controlled trial was conducted. This study was performed at a single hospital and involved 6 colorectal surgeons. In total, 110 patients were enrolled between July 2019 and September 2020. Patients were randomly assigned to undergo either mPSH group (n=55) or CH group (n=55). The primary outcome was to compare postoperative average pain and postoperative peak pain using visual analog scale score between the 2 groups.
Results:
The required duration of analgesia was shorter in the mPSH group than in the CH group, although the difference was not statistically significant (P=0.096). However, the laxative requirement duration (P<0.010), return to work (P<0.010), satisfaction score (P<0.010), and Vaizey score (P=0.014) were significantly better in the mPSH group. The average and peak postoperative pain scores were significantly lower in the mPSH group during the 15 days after surgery (P<0.001). The overall complication rate in both groups was 9.1%, with no significant difference between the groups (P=0.867).
Conclusion
The mPSH group demonstrated better improvement in symptoms, lower pain scores, and greater patient early satisfaction after surgery than the CH group. Therefore, this surgical technique appears to be a safe and effective alternative for CH.
9.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
10.Clinical Trial Protocol for Porcine Islet Xenotransplantation in South Korea
Byung-Joon KIM ; Jun-Seop SHIN ; Byoung-Hoon MIN ; Jong-Min KIM ; Chung-Gyu PARK ; Hee-Jung KANG ; Eung Soo HWANG ; Won-Woo LEE ; Jung-Sik KIM ; Hyun Je KIM ; Iov KWON ; Jae Sung KIM ; Geun Soo KIM ; Joonho MOON ; Du Yeon SHIN ; Bumrae CHO ; Heung-Mo YANG ; Sung Joo KIM ; Kwang-Won KIM
Diabetes & Metabolism Journal 2024;48(6):1160-1168
Background:
Islet transplantation holds promise for treating selected type 1 diabetes mellitus patients, yet the scarcity of human donor organs impedes widespread adoption. Porcine islets, deemed a viable alternative, recently demonstrated successful longterm survival without zoonotic risks in a clinically relevant pig-to-non-human primate islet transplantation model. This success prompted the development of a clinical trial protocol for porcine islet xenotransplantation in humans.
Methods:
A single-center, open-label clinical trial initiated by the sponsor will assess the safety and efficacy of porcine islet transplantation for diabetes patients at Gachon Hospital. The protocol received approval from the Gachon Hospital Institutional Review Board (IRB) and the Korean Ministry of Food and Drug Safety (MFDS) under the Investigational New Drug (IND) process. Two diabetic patients, experiencing inadequate glycemic control despite intensive insulin treatment and frequent hypoglycemic unawareness, will be enrolled. Participants and their family members will engage in deliberation before xenotransplantation during the screening period. Each patient will receive islets isolated from designated pathogen-free pigs. Immunosuppressants and systemic infection prophylaxis will follow the program schedule. The primary endpoint is to confirm the safety of porcine islets in patients, and the secondary endpoint is to assess whether porcine islets can reduce insulin dose and the frequency of hypoglycemic unawareness.
Conclusion
A clinical trial protocol adhering to global consensus guidelines for porcine islet xenotransplantation is presented, facilitating streamlined implementation of comparable human trials worldwide.

Result Analysis
Print
Save
E-mail