1.Metamerism in composite resins under five standard illuminants - D65, A, C, FCW and TL84.
Ki Jeong PARK ; Yun Chan HWANG ; Sun Ho KIM ; Won Mann OH ; In Nam HWANG
Journal of Korean Academy of Conservative Dentistry 2003;28(5):402-408
This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110, Charisma, Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate (L*=96.54, a*=0.19, b*=0.01) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus, Model 4000s, Hunter Lab, USA) by applying standard light source D65, C, Fcw, TL84 and A. Standardization was done with reference standard (X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference(DeltaE*>2). 2. All composites had MI below accepted value 0.5 between standard illuminant(D65, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between D65 and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between D65 and A(p<0.05).
Barium Sulfate
;
Composite Resins*
;
Fungi
;
Polytetrafluoroethylene
2.Extended thymectomy in myasthenia gravis.
Kwang Jo CHO ; Hyung Ryul LEE ; Jong Won KIM ; Hwang Kiw CHUNG ; Si Chan SUNG
The Korean Journal of Thoracic and Cardiovascular Surgery 1992;25(12):1516-1522
No abstract available.
Myasthenia Gravis*
;
Thymectomy*
3.Neuropsychological effects of chronic alcoholism on the tactual-spatial performance and memory.
Jong Sub LEE ; Chan Hyung KIM ; Sung Hoon LEE ; Won Joon HWANG ; Kae Joon YOO
Journal of Korean Neuropsychiatric Association 1993;32(1):59-69
No abstract available.
Alcoholism*
;
Memory*
4.Effects of GnRH Agonist Used for Ovarian Hyperstimulation in Human IVF-ET on the Apoptosis of Preovulatory Follicular Cells.
Hyun Won YANG ; Hyuck Chan KWON ; Kyung Joo HWANG ; Jong Min PARK ; Kie Suk OH ; Yong Dal YOON
Korean Journal of Fertility and Sterility 1999;26(1):55-65
There have been many reports to date regarding the role of GnRH as a local regulatory factor of ovarian function as studies of human and rat ovaries revealed GnRH and its receptor. In recent studies it has been shown that GnRH directly causes apoptosis in the granulosa cells of the rat ovary, and such results leads to the suggestion that the use of GnRH agonist for more stable long term ovarian hyperstimulation in human IVF-ET programs causes granulosa cell apoptosis which may lead to follicular atresia. Therefore this study attempts to determine if granulosa-luteal cell apoptosis occurs in patients during IVF-ET programs in which GnRH agonist is employed for ovarian hyperstimulation. The quality of oocyte-cumulus complexes obtained during ovum pickup procedures were assessed morphologically and then the fertilization rate and developmental rate was determined. Apoptotic cells among the granulosa-luteal cells obtained during the same procedure were observed after staining with Hematoxylin-rosin. The fragmentation degree of DNA extracted from granulosa-luteal cells was determined and comparatively analyzed. There was no difference in the average age of the patients, the number of oocytes retrieved, and fertilization and developmental rates between the FSH/hMG group and GnRH-long group. There was also no difference in the apoptosis rate and pyknosis rate in the granulosa-luteal cells between the two groups. However, when the oocyte-cumulus complexes were morphoogically divided into the healthy group and atretic group without regard for the method of hyperstimulation, the results showed that the number of oocytes obtained averaged 11.09+/-8.75 and 10.33+/-4.53 per cycle, respectively, showing no significant difference, but the fertilization rate (77.05%, 56.99%, respectively, p<0.01) and developmental ,ate (65.96%, 41.51%, respectively, p<0.01) was significantly increased in the healthy group when compared to the atretic group. The degree of apoptosis in the granulosa-luteal cells showed that in the healthy group it was 2.25% which was not significantly different from the atretic group (2.77%), but the pyknosis rate in the atretic group (27.81%) was significantly higher compared to the healthy group (11.35%, p<0.01). The quantity of DNA fragmentation in the FSH/hMG group was 32.22%, while in the GnRH-long group it was 34.27%, showing no significant difference. On the other hand the degree of DNA fragmentation was 39.05% and 11.83% in the healthy group and atretic group, respectively, showing significantly higher increase in the atretic group (p<0.01). The above results suggest that death of granulosa-luteal cells according to the state of the oocyte-cumulus complex is more related to pyknosis rather than apoptosis. Also, the GnRH agonist used in ovarian hyperstimulation does not seem to directly affect the apoptosis of retrieved oocytes and granulosa-luteal cells, and which is thought to be due to the suppression of the apoptogenic effect of GnRH agonist as a result of the high doses of FSH administered.
Animals
;
Apoptosis*
;
DNA
;
DNA Fragmentation
;
Female
;
Fertilization
;
Follicular Atresia
;
Gonadotropin-Releasing Hormone*
;
Granulosa Cells
;
Hand
;
Humans*
;
Luteal Cells
;
Oocytes
;
Ovary
;
Ovum
;
Rats
5.A case of myxoid leiomyosarcoma of uterus.
Dong Hoon HWANG ; Yeon Sook LEE ; Won Il PARK ; Yoon Ho LEE ; Yui Jung KIM ; Chan Il PARK
Korean Journal of Obstetrics and Gynecology 1993;36(7):2058-2062
No abstract available.
Leiomyosarcoma*
;
Uterus*
6.The clinical application of fetal echocardiography ; The usefulness of four-chamber view as a screening test.
Yong Won PARK ; Jae Sung CHO ; Kyung Joo HWANG ; Jong Kyun LEE ; Jun Hee SUL ; Chan Ho SONG
Korean Journal of Obstetrics and Gynecology 1993;36(10):3558-3564
No abstract available.
Echocardiography*
;
Mass Screening*
7.Effects of Low Oxygen Condition on the Development of Mouse Embryos Cultured In Viro.
Jong Hyun WOO ; Kyung Joo HWANG ; Hyun Won YANG ; Chi Hyeong LEE ; Jeong In YANG ; Hyuck Chan KWAN ; Kie Suk OH
Korean Journal of Obstetrics and Gynecology 1998;41(12):2962-2968
OBJECTIVE: It is known that mouse embryos before implantation develop in a low oxygen environment of 3- 8% concentration and with antioxidant materials such as vitamins, antioxidant enzymes, ferrous binding proteins, and albumin in follicular and tubal fluids. However, the 20% oxygen culture condition with chemically defined media might be produce an abundance of ROS, and leads to developmental delay or developmental block in vitro. In this study, we attempt to elucidate the relationship between intracellular H2O2 production and embryo development in different oxygen culture conditions of mouse embryos. METHODS: Prenuclear embryos from C57BL/CBA Fl hybrid and ICR mouse were cultured in incubators which provided 5% carbon dioxide, 20% oxygen and 5% carbon dioxide, 5% oxygen. Measurement of H2O2 level in a embryo was performed with DCHFDA(2, 7 -dichlorodihydroflourescein diacetate)and analyzed with Quanti-cell 700, and the number of blastomeres was counted with DAPI( 4, 6'-diamidino-2-phenylindole). RESULTS: Oxygen concentration of the culture medias was significantly higher in the 20% oxygen environment compared to that of 5% oxygen environment. Culture of mice embryos in high oxygen condition leads to high HO concentrations at 2 cell stage and developmental delay or ""2-cell block"" regardless of the strain. But in a 5% oxygen environment, which is similar to in-vivo conditions HO production was suppressed continuously through out culture and development of embryos was definitely improved. CONCLUSION: These results suggest that there is a difference in the production of ROS or protective mechanism according to the mouse strains and stage of development, and it is thought that in-vitro culture in 5% oxygen environment provides stable in vivo equilibrium but in a 20% oxygen environment there is production of ROS which overcome the protective mechanism which leads to cellular damage and embryo developmental delay.
Animals
;
Blastomeres
;
Carbon Dioxide
;
Carrier Proteins
;
Culture Media
;
Embryonic Development
;
Embryonic Structures*
;
Female
;
Incubators
;
Mice*
;
Mice, Inbred ICR
;
Oxygen*
;
Pregnancy
;
Vitamins
8.A study of insertion depth of gutta percha cones after shaping by Ni-Ti rotary files in simulated canals.
Hyun Gu CHO ; Yun Chan HWANG ; In Nam HWANG ; Won Mann OH
Journal of Korean Academy of Conservative Dentistry 2007;32(6):550-558
The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25 (n = 10), .06 taper #25 (n = 10), ProTaper F2 (n = 10), HEROShaper .04 taper #25 (n = 10) and .06 taper #25 (n = 10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted (p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted (p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.
Dental Pulp Cavity
;
Gutta-Percha*
9.A comparative study on radiopacity of canal filling and retrograde root-end filling materials.
Yong Sang KIM ; Seo Kyong KIM ; Yun Chan HWANG ; In Nam HWANG ; Won Mann OH
Journal of Korean Academy of Conservative Dentistry 2008;33(2):107-114
This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, Dyract(R) AP, Super EBA(R), IRM(R), AH 26(R), Sealapex(TM), Tubli-Seal(TM) and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.
Aluminum
;
Compomers
;
Dentin
;
Glass Ionomer Cements
;
Gutta-Percha
;
Resins, Synthetic
;
Root Canal Obturation
10.Effect of irrigation methods on the adhesion of Resilon/Epiphany sealer and gutta-percha/AH 26 sealer to intracanal dentin.
Seo Kyong KIM ; Yun Chan HWANG ; In Nam HWANG ; Won Mann OH
Journal of Korean Academy of Conservative Dentistry 2008;33(2):98-106
The purpose of this study was to evaluate whether intracanal irrigation method could affect the adhesion between intracanal dentin and root canal filling materials (Gutta-percha/AH 26 sealer and Resilon/Epiphany sealer). Thirty extracted human incisor teeth were prepared. Canals were irrigated with three different irrigation methods as a final rinse and obturated with two different canal filling materials (G groups : Gutta-percha/AH 26 sealer, R groups : Resilon/Epiphany sealer) respectively. Group G1, R1 - irrigated with 5.25% NaOCl. Group G2, R2 - irrigated with 5.25% NaOCl, sterile saline. Group G3, R3 - irrigated with 5.25% NaOCl, 17% EDTA, sterile saline. Thirty obturated roots were horizontally sliced and push-out bond strength test was performed in the universal testing machine. After test, the failure patterns of the specimens were observed using Image-analyzing microscope. The results were as follows. 1. Gutta-percha/AH 26 sealer groups had significantly higher push-out bond strength compared with the Resilon/Epiphany sealer groups (p < 0.05). 2. Push-out bond strength was higher when using 17% EDTA followed by sterile saline than using NaOCl as a final irrigation solution in the Resilon/Epiphany sealer groups (p < 0.05). 3. In the failure pattern analysis, there was no cohesive failure in Group G1, G2, and R1. Gutta-percha/AH 26 sealer groups appeared to exhibit predominantly adhesive and mixed failure patterns, whereas Resilon/Epiphany sealer groups exhibited mixed failures with the cohesive failure occurred within the Resilon substrate.
Adhesives
;
Collodion
;
Dentin
;
Edetic Acid
;
Humans
;
Incisor
;
Root Canal Filling Materials
;
Tooth