2.One case of elderly patients with bronchial foreign body.
Wenzhong BAI ; Changdong YANG ; Debin JIN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2013;27(18):1029-1029
This paper reports one case of elderly patients with bronchial foreign body, and analyzes the causes of misdiagnosis. And the best choice of removing larger foreign body is operating under rigid bronchoscopy.
Aged, 80 and over
;
Bronchi
;
Foreign Bodies
;
Humans
;
Male
3.Stress analysis of distal-extension removable partial dentures supported by mini implants
Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG ; Wen CUI ; Dongmei WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1295-1298
Objective To analyse the stress distribution of distal-extension removable partial dentures supported by mini implants. Methods The finite element analysis models of conventional removable partial dentures ( CRPD) and mini implants supported removable partial dentures (ISRPD) were established by modular denture model. The stress distribution of abutments and supporting tissues was compared by finite element analysis software Abaqus 6.5.Results Under vertical loading, the stress of abutment teeth, mucosa of edentulous region and alveolar bone of ISRPD model was lower than that of CRPD model. Under oblique loading, the stress of each part of CRPD model and alveolar bone of ISRPD model significantly increased, while that of abutment teeth and parodontium of ISPRD model decreased. Conclusion The distal-extension removable partial dentures supported by mini implants work well in protecting the abutments and supporting tissues.
4.Stress analysis of precision attachment dentures for mandibular distal-extension edentulous cases
Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG ; Wen CUI ; Dongmei WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1291-1294
Objective To analyse the stress distribution of precision attachment dentures used in distal-extension edentulous cases. Methods The finite element models of conventional removable partial dentures and precision attachment dentures were established by modular denture model, and the models of precision attachment dentures were established with 4┬4 as one abutment or 43┬34 as two abutments. The stress distribution of abutments and supporting tissues was compared by finite element analysis software Abaqus 6.5.Results Under vertical loading or oblique loading, the stress of abutments and supporting tissues from attachment dentures with two abutments was significantly lower than that from attachment dentures with one abutment. The stress of conventional removable partial dentures significantly increased under oblique loading. Conclusion It is reasonable for the design of attachment dentures with two abutments for mandibular distal-extension edentulous cases.
5.Comparison of stress distribution on telescopic denture and clasp-retention denture for bilateral free-ended cases
Bin WEI ; Jie CHEN ; Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1288-1290
Objective To establish three dimensional finite element model libraries of telescopic dentures and removable partial dentures by means of model libraries, and compare the characteristics of stress distribution among three prostheses. Methods Normal model libraries were imported and edited, and models of bilateral free-ended cases were established. Based on the model libraries of fixed partial dentures and removable partial dentures, the finite element models of telescopic dentures and removable partial dentures with medial or distal occlusal rest were established using softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, then finite element stress analysis was performed. Results The stress distribution on abutment root, parodontium, alveolar mucosa and alveolar bone was uniform. The maximum value of stress on the abutment root (6.205 Mpa) was much less than those of two removable partial dentures (18.41 Mpa and 34.49 Mpa). Conclusion For bilateral free-ended cases, the telescopic denture design is uniform in stress distribution with less stress on abutment root, which is healthy to the abutment root and surrounding tissues.
6.Model establishment and stress analysis of telescopic crown-retained removable partial dentures
Bin WEI ; Qingfeng HUANG ; Wenzhong JIN ; Jie CHEN ; Fuqiang ZHANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1285-1287
Objective To redevelop the finite element model libraries and to analyse the stress distribution of telescopic crown dentures. Methods The finite element model libraries were redeveloped based on the model libraries of normal dentition, fixed partial denture and removable partial denture. With the help of softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, the telescopic denture models on the bilateral free-ended case were imported and edited, then the finite element stress analysis was performed. Results The models were easily established. The maximum value of stress and its distribution on abutment root, periodontal membrane, alveolar mucosa, alveolar bone and dental prostheses were observed and studied by the finite element stress analysis. Conclusion The way to establish models of telescopic crown dentures by model libraries is feasible and reliable.
7.Nosocomial Infection in Schizophrenics with Tuberculosis:A Clinical Analysis
Zhixing JIN ; Wenzhong CHEN ; Bingrong YUAN ; Ping XU ; Jianxi SHI
Chinese Journal of Nosocomiology 2006;0(08):-
OBJECTIVE To investigate the clinical features and causes of nosocomial infection in schizophrenics with tuberculosis so as to take effective measures for better prevention and treatment.METHODS A retrospective investigation was used to analyze the clinical features and causes of nosocomial infection in 207 schizophrenics with tuberculosis.RESULTS The rate of nosocomial infection in schizophrenics with tuberculosis was 39.13%.The main infection way was via respiratory tract,followed by skin,soft tissue and gastrointestinal tract.The period and degrees of tuberculosis,the history of smoking,psychiatric symptoms and the complications were the causes of nosocomial infection.CONCLUSIONS Controlling psychiatric symptoms actively,preventing and treating somatic complications,using antibiotics rationally and less or no smoking are the effective measures to avoid nosocomial infection in schizophrenics with tuberculosis.
8.Comparison between SPECT and MRI in detecting skull-base invasion in nasopharyngeal carcinoma
Li ZHANG ; Rui AO ; Jinchuan WANG ; Jin HUANG ; Xiaoyun WU ; Han ZHOU ; Wenzhong SONG ; Mingxi CHEN
Chinese Journal of Radiation Oncology 2008;17(6):417-420
Objective To investigate the ability of single photon emission computed tomography (SPECT) and MRI in detecting skull-base invasion in nasopharyngeal carcinoma. Methods Sixty-one patients with nasopharyngeal carcinoma received whole body and skull-base tomography SPECT, and nasopharynx and skull-base MRI before radiotherapy. The results were double-blind compared and evaluated. Results The overall positive rates of skull-base invasion detected by SPECT and MRI were 51% and 46% (P=0.508). In paitents with headache, cranial nerve palsy or both, the rates were 83% and 86% (P=1.000) ,80% and 80% (P=1.000), 88% and 94% (P=1.000), respectively. In patients with T1+T2 and T3+T4lesions,the rates were 22% and 0(P=0.031) ,74% and 82% (P=0.250) ,repectively. In patients with N0+N1and N2+N3lesions,they were 50% and 48% (P=1.000) ,53% and 40% (P=0.500) ,respectively. The conformation rate between SPECT and MRI was 85%. Binary Logistic regression analysis showed that T stage was a risk factor for positive SPECT(χ2=4.23,P=0.040, OR=3.04). Headache tended to be a risk factor for both positive SPECT and positive MRI (χ2=3.13, P=0.077, OR=4.54;χ2=3.64,P=0.056,OR=12.00). Conclusions The detection sensitivity of SPECT in skull-base invasion in nasopharyngeal carcinoma is equivalent to that of MRI. The consistency between SPECT and MRI is good. Moreover, there is a good correlation between SPECT and symptoms, signs and stage. SPECT of skullbase tomography is necessary for patients with severe headache, negative CT and those who can not receive MRI. When SPECT result is positive,skull-base should be considered to be invaded and should be defined as gross tumor volume in radiotherapy planning.
9.Stress analysis of distal-extension prosthetics with mesial and distal occlusal rest
Wenzhong JIN ; Qingfeng HUANG ; Bin WEI ; Fuqiang ZHANG ; Wen CUI ; Chengtao WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1282-1284
Objective To investigate the stress distribution in the abutment and supporting tissues of distal-extension removable partial dentures with mesial and distal occlusal rest under loading. Methods A modular denture model was used to build a model of mandibular dentition defect ( 765┬567 loss) with HyperMesh 7.0 software. Prosthetics with mesial (M model) and distal occlusal rest (D model) were designed with UG 5.0 software, and the finite element models were completed with HyperMesh 7.0 software. The stress distribution was analyzed in the abutment and supporting tissues of distal-extension removable partial dentures with mesial and distal occlusal rest when bilateral vertical forces were applied. Results Compared with M model, D model provided much larger maximum stress in abutments and periodontal membrane. Stress of D model mainly concentrated on roots of 4┬4 , while that of M model uniformly distributed on roots of 43┬34 . The maximum stress of M model was significantly larger than that of D model on the mucosa of edentulous region. The maximum stress on alveolar bone of two models' edentulous region was equal, while the stress of M model distributed more widely. Conclusion It is prior to select mesial occlusal rest in distal-extension removable partial dentures.