1.Deformation of the Cupula of a Semicircular Canal Based on a Biomimetic Physical Model
Wenxuan ZHANG ; Yu ZHANG ; Xianhua WEN ; Junjie DAI ; Yixiang BIAN ; Yani JIANG
Journal of Medical Biomechanics 2024;39(3):524-531
Objective To explore the biomechanical responses of the cupula of the human semicircular canal to three basic rotational perception processes.Methods A one-dimensional visual semicircular canal model was successfully fabricated using three-dimensional printing and hydrogel physical cross-linking technologies,and the response deformation of the cupula was explored by applying constant angular velocity,constant angular acceleration,and sinusoidal oscillation stimulations.Results The time constant of the biomimetic semicircular canal model was stable at approximately 3 s and close to the human time constant.The displacement deformation of the ampullary cupula was proportional to the angular acceleration applied.Under sinusoidal oscillation stimulation of 0.07-5.00 Hz,the gain of the semicircular canal increased from 1.54 um/° rises to 42.34 μm/°,but the phase difference decreased from 109.72° to 11.27°.Conclusions The biomimetic semicircular canal model prepared in this study can accurately simulate the working mechanism of the human semicircular canal and is expected to play a role in mechanism research and disease diagnosis of the human vestibular semicircular canal.
2.A preliminary investigation study of islet function assessment
Wenxuan BIAN ; Yunqiang HE ; Qi FU ; Shuang CHEN ; Min SUN ; Tao YANG
Chinese Journal of Diabetes 2024;32(3):161-168
Objective To investigate doctors'knowledge and differences in islet function assessment methods in China.Methods This is a cross-sectional study that conducted by online questionnaire survey.Demographic data,examination items,blood collection point of OGTT,detection method,kit type and follow-up frequency were collected and compared among doctors in different regions,different levels of hospitals,different specialties and different titles.Results 79.2%and 85.1%of physicians believed that the levels of insulin and C-peptide should be measured at the same time to assess islet function in patients with newly diagnosed and follow-up diabetes mellitus patients.Endocrinologists preferred to access insulin and C-peptide at the same time(P<0.05).56.0%of physicians chose bread meal test for T1DM patients and 54.7%for T2DM patients.Compared with non-specialists,endocrinologists preferred to commit bread meal test to T1DM patients(61.4%vs 41.0%,P<0.05).In addition,for the islet function assessment of new-onset diabetes patients,7.6%of physicians chose the six-point method(0,30,60,90,120,180 min),27.3%selected the five-point method I(0,30,60,120,180 min),8.5%selected the five-point method II(0,30,60,90,120 min),9.8%selected the four-point method I(0,30,60,120 min),10.3%selected the four-point method II(0,60,120,180 min),13.8%chose the three-point method(0,60,120 min)and 13.4%chose the two-point method(0,120 min).At the time of follow-up assessment,the above selection rates were 5.3%,20.4%,6.4%,6.6%,9.4%,15.8%and 24.1%,respectively.In terms of the frequency of assessment,39.2%of doctors assessed islet function once a year and 24.7%once every six months.Specialists preferred to assess islet function once a year,and physicians with senior titles chose to assess islet function more variably.Conclusion At present,there are still great differences in assessment methods of islet function in China.It is of great significance for the clinical diagnosis and treatment of diabetes to understand the differences in the selection of islet function assessment methods among doctors in different regions,specialties and job titles.