1.A comparative study of TPA-Nance combined anchorage and face bow in reinforcing the maxillary first molar anchorage
Hongyan ZHAO ; Wenru JIANG ; Ye ZHANG ; lin LI ; Xiufang WANG
Journal of Practical Stomatology 2000;0(06):-
0.05).Conclusions:Combined anchorage can provide maximum anchorage compared with traditional face bow and was accepted easily by patients.
2.Design of Rehabilitation Training System with Electromyography Feedback for Stroke Patients.
Chenxu YU ; Zheng WANG ; Zhengang YU ; Jiaying GUO ; Wenru ZHAO ; Haihong ZHAO ; Haijun NIU ; Yubo FAN
Chinese Journal of Medical Instrumentation 2015;39(3):187-205
This paper proposed a rehabilitation training system with electromyography (sEMG) feedback for stroke patients based on ARM embedded system and LabVIEW. The system can achieve real-time acquisition, processing and dualview of multi-channel sEMGs and compute related sEMG parameters including iEMG, RMS, MPF and co-contraction ratio. The system was detected by clinical experiments and related inspection department. The result showed that the system is functional, interactive and in accordance with the relevant standards for medical devices so that it can fully satisfy the clinical demands. In addition, the system can help doctors to master the training state of the patient more effectively in a real-time and quantitative way that is direct to improve the training programs of stroke patients.
Electromyography
;
Humans
;
Neurofeedback
;
Stroke Rehabilitation
3.Mechanism of weight relief walking remodeling and abnormal gait revising training device and its clinical indication
Wenru ZHAO ; Haihong ZHAO ; Jianfei HUO ; Aiping SUN ; Xiao CAO ; Xuemin ZHANG ; Hongquan SU
Chinese Journal of Tissue Engineering Research 2009;13(48):9455-9458
A device for promoting normal locomotor activity recuperation was made, which was composed by frame, elastic bolt and normal gait mark carpet. The device has the effects of weight relieving, abnormal gait preventing, and safeguards providing. The patient could do gait training by he/her self or assistant self training under the weight reducing and protecting of the device in order to improve the walking ability and the normal gait formation. It is effective for preventing drop foot and leg adduction, and also helpful for the recovery of normal gait ability and the prevention of abnormal gait formation. It is applicable for the patient who can not be trained with ordinary weight relief walking training, such as severe cerebral palsy and severe spasmodic lower extremity and foot drop after brain injury. The results demonstrated that the device is effective in protecting, correcting, preventing abnormal gait as well as forming normal gait.
4.Design Principle and clinical indications of the multifunctional training-box for extremities
Wenru ZHAO ; Jianfei HUO ; Zheng WANG ; Haihong ZHAO ; Xuemin ZHANG ; Aiping SUN ; Xiao CAO ; Xin LI
Chinese Journal of Tissue Engineering Research 2009;13(39):7675-7678
To make a portable apparatus for the patient self-doing joint voluntarily exercise that is keeping with the training demand of human body potential and muscle strong. Different kinds of spring belts are used for joint exercise apparatus according to the needs of joint exercise. Though active joint extension and flexion by using the method of Chinese physical and breathing exercises, the exercise was done by drawing the spring belt. The extremity multifunctional training box is easy for carrying and sutble for each mussel be trained. Because of the wide range of back spring power, it is easy to reach the best training mount and to do the continually training under the biggest training mount. It is beneficial to the joint active function improvement. From June 2006 to February 2008, this kind of apparatus was used in 30 patients with footdrop at the Beijing Tongren Hospital, Capital Medical University. The design of the extremity multifunctional training box is reasonable, and it is easy for carrying and operating. It is also helpful for the patient to do muscle exercise themselves, and the joint function can be persisted and improved by continual exercise using this apparatus.
5.The Device Developed for Potentialities Training of Lower Extremities and Its Clinical Indications
Wenru ZHAO ; Xiao CAO ; Haihong ZHAO ; Jianfei HUO ; Aiping SUN ; Xuemin ZHANG ; Hongquan SU
Chinese Journal of Rehabilitation Theory and Practice 2008;14(10):922-924
Objective To develop one kind of device that can not only reduce the body weight,but also provide a good condition for training lower extremity potentialities.Methods The body weight bearing support and protection system,body weight reducing system and scaled footboard were made respectively.The lower extremity potentialities,nervous conduction speed and leg motion coordination ability training were done under protection and body weight reducing.Results The potential training device could exactly protect the patient and reduce body weight,and make the training step by step.Under the effects of protecting and body weight reducing of the potential training device,the training could be performed together with the Chinese traditional medicine rehabilitation method;that was physical and breathing exercises.The lower extremity potentialities were developed nicely.Conclusion The lower extremity potentialities training device is a useful training device which can bear body weight,have protective effect,develop lower extremity potentialities and improve coordination ability of lower extremities.
7.Study on the Characteristics of EMG Signal of the Masticatory Muscles in Different Materials
Hui SHEN ; Zhengang YU ; Jiaying GUO ; Tengyu ZHANG ; Wenru ZHAO
Chinese Journal of Medical Instrumentation 2016;40(5):314-317
Objective To investigate the activities of different soft and hard materials during right chewing masticatory muscles, describing the masticatory muscles of time domain and frequency domain features. Methods 11 experimental subjects who conform to the standards of measurement chew two materials of different soft and hard texture. Then record surface EMG of each bilateral temporalis anterior bundle, masseter, two bilateral anterior abdominal muscles, analysis to 5 kinds of characteristics of the study of EMG.Results When subjects chewing different soft and hard materials, al the EMG features in the bilateral anterior temporalis and masseter values had signifi cant difference (P < 0.05). The results in bilateral digastric anterior abdominal except zero crossing rate have signifi cant difference; median frequency on the right side of the masticatory muscle has decreased trend. ConclusionThe anterior temporalis and masseter EMG active more intense when chewing hard objects; the right side of the masticatory muscles have obvious fatigue trend after chewing hard masticatory 30 cycles.
8.Risk factors for rotator cuff tear and corresponding prediction efficacy
Zengshuai HAN ; Yi ZHANG ; Lei DING ; Xia ZHAO ; Ruting CUI ; Wenru MA ; Yingze ZHANG ; Tengbo YU
Chinese Journal of Trauma 2022;38(3):213-219
Objective:To analyze the risk factors for rotator cuff tear and evaluate the corresponding prediction efficacy.Methods:A case-control study was conducted in 69 patients with rotator cuff tear admitted to Affiliated Hospital of Qingdao University from June 2020 to June 2021 (rotator cuff tear group) and 51 normal volunteers or medical examiners (normal control group). There were 55 males and 65 females, with the age range of 34-77 years [(58.2±7.2)years]. Body mass index (BMI) ranged from 19.5-32.4 kg/m 2 [(25.4±2.5)kg/m 2]. Univariate analysis was performed for the correlation of gender, age, history of hypertension, history of smoking, history of diabetes, BMI, angle of humeral greater tuberosity and notch angle of humeral greater tuberosity with rotator cuff tear in the two groups. Factors with statistically significant differences were included in multivariate Logistic regression analysis to determine the independent risk factors for rotator cuff tear. Spearman correlation analysis was used to find factor correlation between the two groups. The receiver operating characteristic (ROC) curve of relevant factors for the diagnosis and prediction of rotator cuff tear was analyzed. Results:Univariate analysis showed that age, angle of humeral greater tuberosity and notch angle of humeral greater tuberosity related to rotator cuff tear (all P<0.05). On the contrary, gender, history of hypertension, history of smoking, history of diabetes and BMI were not correlated with rotator cuff tear (all P>0.05). Multivariate Logistic regression analysis showed significant correlations of angle of humeral greater tuberosity and notch angle of humeral greater tuberosity with rotator cuff tear (all P<0.05). Spearman correlation analysis showed that age was not correlated with angle of humeral greater tuberosity and notch angle of humeral greater tuberosity ( r=0.09, 0.13, all P>0.05), but there was significant positive correlation between angle of humeral greater tuberosity and notch angle of humeral greater tuberosity ( r=0.76, P<0.01). When the optimal cutoff values of angle of humeral greater tuberosity and notch angle of humeral greater tuberosity were 70.05° and 150.55°, the area under the ROC curve (AUC) for predicting rotator cuff tear was 0.79 (95% CI 0.71-0.87, P<0.01) and 0.81 (95% CI 0.74- 0.89, P<0.01). Conclusions:Angle of humeral greater tuberosity and notch angle of humeral greater tuberosity are independent factors for rotator cuff tear, and larger angles suggest higher prevalence of rotator cuff tear. Besides, the notch angle of humeral greater tuberosity has relatively better predictive performance.
9. Statins in periodontitis therapy
Shanshan LI ; Yusheng GUO ; Fang WANG ; Yueguang ZHAO ; Juhua DAN ; Wenru TANG
Chinese Journal of Stomatology 2017;52(2):91-95
Statins inhibit the activity of enzyme 3-hydroxy-3-methyl-acetyl coenzyme A reductase and further inhibit cholesterol synthesis. Statins are the most widely used cholesterol-lowering drugs in clinical practice. Studies have found that statins also play a positive role in periodontitis treatment. In this paper, we reviewed the functions of statins in bone metabolism and anti-inflammation in periodontitis. In addition, the application of statins as a local drug delivery system in the treatment of periodontitis was described.
10.Development of Self Training Device for Lung Function Compliance Guided by Meridians.
Ming QI ; Haiying PANG ; Luyang JIA ; Ying FANG ; Aimin WANG ; Hongquan SU ; Xiujuan XIE ; Haiying WANG ; Wenru ZHAO
Chinese Journal of Medical Instrumentation 2021;45(5):503-506
OBJECTIVE:
To develop a self deep breathing training device which can improve lung function compliance and blood oxygen saturation.
METHODS:
The device consists of four parts:flow tube, measuring cylinder, mobile phone holder and meridian guidance audio-visual synthesis training software. The flow tube measures the flow rate of inhaled gas, the metering cylinder measures the total amount of inhaled gas, and the mobile phone rack is equipped with a mobile phone storing the meridian guidance audio-visual synthesis training software.
RESULTS:
The device is reasonable in structure and flexible in operation, which can meet the requirements of self deep inspiration training under the guidance of training module.
CONCLUSIONS
Deep inspiration training under the guidance of guidance training module can form "deep and slow" abdominal breathing, and then improve lung function.
Cell Phone
;
Lung
;
Meridians
;
Software