1.Study on verification and evaluation for the performance of a nucleic acid test system of screening blood
Wengong DU ; Xinghuan MA ; Peng YIN ; Peipei WANG ; Juan LIU
China Medical Equipment 2024;21(10):19-23
Objective:To evaluate main performance indexes and application value of a domestic blood nucleic acid test system for blood screening,so as to ensure the safety of blood screening in the system of blood bank.Methods:Twenty samples were selected from Langfang Center Blood Bank in January 2022,and 6703 blood specimens of voluntary blood donors from Langfang Blood Bank between 2022 and 2023 were simultaneously selected.According to the requirements of the"Technical Operating Procedures for Blood Stations(2019 Edition)"and the standard for medical medicine industry"Nucleic Acid Amplification Test Reagents(kits)",the performances of stability,analytical specificity,sensitivity,precision,anti-interference ability and against cross-contamination ability of nucleic acid test system were verified for the analysis of clinical application.Results:The coincidence rate of the nucleic acid test system was 100%for 20 negative plasma samples.The coincidence rates of the sensitivities of Hepatitis B virus deoxyribonucleic acid(HBV DNA),Hepatitis C virus ribonucleic acid(HCV RNA)and Human immunodeficiency virus ribonucleic acid(1+2)(HIV 1+2 RNA)were respectively 100%,and percentages of the coefficient of variation(CV%)of the precision of them were respectively 1.57%,0.75%and 1.49%.When the system conducted nucleic acid test,the hemolytic plasma with a hemoglobin concentration level of 400mg/dl and the blood specimen with triglyceride concentration levels of 3 000 mg/dl did not affect the analysis performances of the standard substances of HBV-DNA(9.0 IU/ml),HCV-RNA(30.0 IU/ml)and HIV-RNA(135.0 IU/ml)of low concentration level.There were not cross-contaminations when 10 positive samples at high concentration(1 000 IU/ml)were cross-lined with 11 negative samples to conduct test.A total of 16(0.24%)reactive specimens were checked out from 6 703 specimens by Nucleic Acid Test(NAT)Technique under mixed mode.Conclusion:Nucleic acid test system must conduct performance verification before it is put into use,so as to ensure the safety of blood screening.The currently domestic nucleic acid test system can meet the requirements of screening blood safety.The performance verification of nucleic acid test system has great value in ensuring the safety of blood screening.
2.Unqualified rate of anti-HIV detection in the laboratories from blood banks in Beijing-Tianjin-Hebei region
Wei ZHEN ; Hongwei GE ; Rui WANG ; Tong PAN ; Wei HAN ; Peng WANG ; Li YANG ; Shaoqiu SUN ; Xiao CAO ; Liye CUI ; Chao WEI ; Guijun YU ; Yunpeng XU ; Jinjuan FANG ; Caixia LIU ; Xuegang WANG ; Zhijun ZHEN ; Xiaojie LIU ; Wengong DU ; Lunan WANG ; Jiang LIU ; Hongjie WANG
Chinese Journal of Blood Transfusion 2021;34(4):371-376
【Objective】 To investigate the unqualified rate of anti-HIV detection of blood screening laboratories in Beijing-Tianjin-Hebei region, and explore the differences in anti-HIV detection ability and influencing factors in each laboratory. 【Methods】 Through filling questionnaires via e-mail, the anti-HIV ELISA unqualified rate and confirmed (WB) positive results (data) from January to December 2018 from 15 blood screening laboratories in Beijing-Tianjin-Hebei region were collected. Our laboratory was responsible for data collection and confirmation, and statistics software SPSS22.0 was used for analysis. 【Results】 1) There was a statistically significant difference among the unqualified rate of anti-HIV ELISA(6.77‱~35.71‱) and confirmed positive rate(0.60‱~3.56‱) in 15 blood screening laboratories in Beijing-Tianjin-Hebei region (P<0.05); 2) There were significant differencse among the ELISA unqualified rate and the confirmed positive rate of 8 reagents for anti-HIV detection(P<0.01), and the sensitivity of the 4th generation detection reagent and the imported reagent was higher than that of the 3rd generation reagent and the domestic reagent. The anti-HIV ELISA unqualified rate of R5 was the highest (19.08‱). 3)There were significant differences in the anti-HIV ELISA unqualified rate of R1, R2, R3, R5 and R7 reagents among different blood station laboratories(P<0.05), and there were no significant differences in the anti-HIV ELISA unqualified rate of R4, R6 and R8 reagents among different blood station laboratories(P>0.05). 4)The unqualified rate of anti-HIV ELISA of laboratories using different regents showed significant differences(P<0.05), except H, J, M. The unqualified rate of imported reagent was significantly higher than that of domestic reagents of laboratories using imported and domestic reagents combinations(P<0.05), except O. 62.5% (5/8) laboratories using domestic 3rd and 4th generation reagent combination showed significant differences in the unqualified rates among different reagents(P<0.05); 5) The positive rate of single-reagent(62.02%~95.45%)in 15 blood screening laboratories showed significant difference(P<0.001), and A was the lowest (62.02%). 【Conclusion】 The anti-HIV detection ability among 15 blood screening laboratories in Beijing-Tianjin-Hebei region is quite different. The application of different reagents is the main factor for the difference, and other factors such as personnel, instruments and test strategies also has a great impact on the detection of anti-HIV. It is still necessary to promote the process of homogenization of blood testing quality among blood screening laboratories in Beijing-Tianjin-Hebei region.