1.Transcatheter closure of atrial septal defects--is balloon sizing still necessary?
Swee Chye QUEK ; Wen X WU ; Kit Y CHAN ; Ting F HO ; William C YIP
Annals of the Academy of Medicine, Singapore 2010;39(5):390-393
INTRODUCTIONThe device closure of atrial septal defects has evolved over the years. In the early days of transcatheter occlusion, balloon sizing was used to choose an appropriate sized device. We postulate that balloon sizing does not value-add to the procedure and is unnecessary.
MATERIALS AND METHODSPatients who had balloon sizing, with (Group 1, n = 38) or without (Group 2, n = 21) atrial septal defect closure, were compared to another group (Group 3, n = 64) who had atrial septal defect closure without balloon sizing. Although the atrial septal defect size (mm) in those without balloon sizing (Group 3) compared to patients who had balloon sizing (Group 1) (18.3 +/- 5.4 vs 14.8 +/- 5.8; P = 0.021) was larger, the Amplatzer septal occluder size chosen (mm) (21.6 +/- 6.3 vs 21.2 +/- 8.1; P = 0.693) was similar.
RESULTSWe analysed the degree of absolute sizing, defined as [(Balloon or Amplatzer occluder size) - (transoesophageal echocardiography size)], versus relative sizing, which is defined as [(Balloon or Amplatzer occluder size)--(transoesophageal echocardiography size) / (Balloon or Amplatzer occluder size)]. It was evident that there was greater absolute and relative over-sizing (6.3 +/- 4.4 mm vs 4.2 +/- 2.1 mm; P = 0.009 and 28.3 +/- 15.4% vs 20.0 +/- 7.0%; P = 0.001, respectively) in patients with balloon sizing (Group 1) compared to those who did not (Group 3). Even a greater degree of absolute (5.1 +/- 3.9 mm vs 9.5 +/- 4.7 mm; P <0.001) and relative over-sizing (24.8 +/- 15.6% vs 33.0 +/- 13.6%; P = 0.001) was observed in patients who had balloon sizing but there was no closure (Group 2) compared to those who had balloon sizing and closure of their defects (Group 1).
CONCLUSIONOur results showed that balloon sizing tended to over-size the atrial septal defect. This may have an important bearing in selecting a larger device than necessary, or even precluding transcatheter closure of the larger atrial septal defects. It is also associated with increased procedural, fluoroscopy time and cost. We suggest that balloon sizing may no longer be necessary in the protocol of device closure of an atrial septal defect.
Adolescent ; Adult ; Aged ; Cardiac Catheterization ; instrumentation ; methods ; Child ; Child, Preschool ; Echocardiography, Transesophageal ; Female ; Heart Septal Defects, Atrial ; diagnostic imaging ; pathology ; surgery ; Humans ; Male ; Middle Aged ; Septal Occluder Device ; Young Adult
2.Effect of influenza and 23-valent pneumococcal polysaccharide vaccinations on elderly with chronic obstructive pulmonary diseases: a community-based intervention study.
Y WEN ; L HE ; Y ZHAI ; J WU ; Y Y CHEN ; H WANG ; Q Q ZONG ; X F LIANG
Chinese Journal of Epidemiology 2018;39(6):792-798
Objective: To explore the effect of influenza and 23 valent pneumococcal polysaccharide pneumococcal vaccinations on symptom-improvement among elderly with chronic obstructive pulmonary diseases (COPD). Methods: Data was gathered from 4 communities in 3 National Demonstration Areas set for comprehensive prevention and control of chronic non- communicable diseases in Chongqing city and Ningbo city respectively, from November 2013 to October 2014. The communities were selected by cluster sampling and divided into 4 groups: (1) injected influenza vaccines; (2) injected with pneumococcal vaccines; (3) received both of the two vaccines; (4) the control group that without any intervention measures. All the subjects aged from 60 to 75 were selected to fill in demographic information questionnaire and receive (COPD assessment test, CAT) scores twice, before intervention and 1 year after the vaccination. SAS 9.4 software was used to analyze the change of symptoms and CAT scores before and after the intervention program and comparing the improvement on symptoms among the elderly people under study. Results: A total of 1 244 subjects with nearly same baseline conditions after the propensity score matching, were involved in this study. CAT scores appeared as Median=21 (IQR: 17-26) at baseline. The CAT scores appeared as Median=18 (IQR: 14-24), decreasing in all the 3 vaccinated groups, one year after the intervention program (influenza vaccines, matching t test, t=-6.531, P=0.403; pneumococcal vaccines, Wilcoxon test, H=-9 623, P<0.001; combined vaccine vaccines, matching t test, t=-10.803, P<0.001). However, in the control group, no obvious change was observed (Wilcoxon H=1 167, P=0.403). Proportions of impacts at high or very high levels all decreased in the 3 intervention groups, while little change was observed in the control group. Outcomes from the Factorial analysis suggested that influenza vaccination could improve the general conditions and symptoms including cough, chest tightness, dyspnea, physical activities, and stamina. Pneumococcal vaccination appeared more effective on all of symptoms and indicators. Conclusion: Pneumococcal and influenza vaccination seemed helpful for elderly people suffering COPD to improve the general health condition.
Aged
;
Humans
;
Influenza Vaccines/immunology*
;
Influenza, Human
;
Pneumococcal Vaccines/immunology*
;
Pneumonia, Pneumococcal/prevention & control*
;
Pulmonary Disease, Chronic Obstructive/complications*
;
Streptococcus pneumoniae
;
Surveys and Questionnaires
;
Vaccination/statistics & numerical data*
;
Vaccine Potency