1.Microwave Processing Technology of Pangolin
China Pharmacy 2001;0(09):-
OBJECTIVE:To explore the microwave processing technology of Pangolins.METHODS:With"heaved and curled in shape,golden yellow or brown in color,crisp in quality" as standards to optimize the microwave processing technology of Pangolins.The contents of water soluble extractive and protein,and the yields in Pangolins were determined.RESULTS:The optimal microwave processing conditions for Pangolins were as follows:with 100% of the microwave firepower baking for 3.5 min.The contents of water soluble extractive and protein in Pangolins and the yields were all higher in microwave processing compared with stir-baking in sand method,CONCLUSLON:The microwave processing is superior to the traditional stir-baking method in that the processed products enjoy a good quality and the method is simple,safe,effective and pollution-free,which also provides a theoretical basis for the industrial production of Pangolins.
2.Discussion on disposal and reuse of large medical equipment
China Medical Equipment 2017;14(1):95-97
Objective:To standardize the process of abandonment management of large medical equipment in hospital, and to achieve the reasonable reuse after large medical equipment were abandoned.Methods: To discuss the conditions, process and reuse assessment when large medical equipments were abandoned, and the concrete operation methods about the abandonment disposition and reused process of large medical equipments.Results:This research has achieved safety and efficient abandonment for large medical equipments under ensuring maximizing benefits of economic efficient.Conclusion: This method reduces the cost of medical device in hospital and create higher social benefits under ensuring maximizing benefits of economic efficiency by standardizing abandonment process and reuse assessment and the safety application for large medical equipment.
3.Clinical study of ulinastatin on the treatment of systemic inflammatory response syndrome in severe acute pancreatitis
Zhijun ZHU ; Weixing YOU ; Yi CHEN
Chinese Journal of Postgraduates of Medicine 2009;32(4):29-31
Objective To evaluate the clinical value of ulinastatin on the treatment of systemic inflammatory response syndrome in severe acute panereatitis. Method Eighty-four patients with severe a-cute pancreatitis were randomly divided into two groups. In the treatment group (42 cases),on the base of routine treatment, ulinastatin was administered intravenously for seven days after hospitalization, while in the control group only routine treatment was given (42 cases) to. Inflammatory factors in serum, the change of liver function and renal function were measured in two groups before and after the treatment, and the clinical efficacy were observed. Results There was significant difference, in the serum level of tumor necrosis factor-α, interleukin-1, interleukin-6, alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen and creatinine on the 7th day between two groups (P < 0.05 or < 0.01 ) ,there were significant differences in the incidence of complications, hospitalization time, incidence of multi-organ failure between two groups [14.3%(6/42) vs 38.1%(16/42), (29.4 ± 1.5)d vs (34.4 ± 1.8)d, 28.6%(12/42) vs 47.6%(20/42), P<0.01 or <0.05 ]. Conclusions Ulinastatin can suppress the secretion and release of some inflammatory factors, protect the important viscera functions and reduce the incidence of complications, and it has favorable clinical efficacy.
4.Loss of visualization of digitations of hippocampal head in MRI in the evaluation of hippocampal sclerosis
Wenhua LI ; Tianzhen SHEN ; Jinyong ZHU ; Weixing ZHONG
Chinese Journal of Tissue Engineering Research 2005;9(21):246-247
BACKGROUND: At present, MRI is the key method to examine the hippocampal sclerosis of the patients with epilepsy. The main results are the abnormal signals of hippocampus, in addition, other symbols of MRI can also suggest the hippocampal sclerosis.OBJECTIVE: To study the significance and value of the loss of visualization of digitations of hippocampal head in diagnosis of hippocampal sclerosis through the analysis of MRI on patients with temporal lobe epilepsy.DESIGN: Non-randomized, blind procedure(data selection, result evaluation), blank controlled and clinical experiment.SETTING: Departments of radiology in two universities.PARTICIPANTS: Between September 1996 and December 2002, 18 patients with temporal lobe epilepsy were selected from the Department of Radiology,Xinhua Hospital Affiliated to Shanghai Second Medical University. Meanwhile,patients with headache were diagnosed with MRI. Eighteen healthy people,whose ages were matched, were as control group.METHODS: Among 18 patients, MRI of 16 patients and 18 people in the control group were performed with a GE 1.5T Horizon MR unit and another 2with a GE 1.5T Signa whole body MR unit. With the double blind procedure, whether the digitations of hippocampal head of 72 hippocampal heads of 36 people in both patient and control groups exist or not was recorded by two radiologists with knowledge of hippocampal dissection but without knowing the condition of clinical operation. The results were divided into 3 levels:loss, poorly visible and existing, and hippocampal atrophy and abnormal signals were also recorded.MAIN OUTCOME MEASURES: Image condition of digitations of head,size of hippocampal head and changes of signal.RESULTS: Of 18 patients with hippocampal sclerosis, the abnormal findings included smooth and the loss of visualization of digitations of hippocampal heads seen in 16 patients, poorly visible of digitations of hippocampal head in one patient, and existence of digitations of hippocampal head in one patient. Hippocampal atrophy and high signals on T2-weighted images and fluid-attenuated inversion recovery imaging were seen in all patients. The sensitivity of loss of digitations of hippocampal heads for diagnosis of hippocampal sclerosis was 88.9% (16/18), and the specificity was 100%.CONCLUSSION: The loss of visualization of digitations of hippocampal head is a sensitive indicator for the diagnosis of hippocampal sclerosis. Atrophic changes of hippocampus combining with the increase of T2-weighted signal can definitely diagnose the hippocampal sclerosis.
5.Facial nerve preservation in acoustic neuroma microsurgery
Fengyi ZHU ; Ning LIU ; Weixing HU ; Al ET
Chinese Journal of Microsurgery 2000;0(04):-
Objective To study the skills of facial nerve preservation in acoustic neuroma microsurgery. Methods Seventy four cases of acoustic neuromas treated microsurgically by suboccipital retrosigmoid transmeatus approach were analyzed retrospectively, including their clinical symptoms and characteristic image, the pathological anatomic relationships of facial nerve and tumor, microsurgical technique. Results Total resection of the tumor was achieved microsurgically in 72 cases, subtotal resection in 2 cases. Facial nerve was kept anatomic intact in 67(90.5%) of the patients. Intracranial end to end anastomosis of the facial nerve was performed in 4 cases. No patient died in this series. Conclusions Microneurosurgical technique is a safe and effective method for total resection of acoustic neuroma. It is key point for keeping facial nerve anatomic intact to understand the pathological anatomic relationships of facial nerve and tumor.
6.Uncertainty Evaluation in Carbamazepine Determination in Human Plasma by HPLC-MS/MS
Shenghui MEI ; Li YANG ; Zhigang ZHAO ; Weixing FENG ; Leting ZHU
China Pharmacist 2016;19(3):419-423
Objective:To evaluate the uncertainty in carbamazepine ( CBZ) determination in human plasma by HPLC-MS/MS. Methods:The whole process of CBZ determination was analyzed and the uncertainty sources were established, and then the uncertainty was evaluated and combined, and the expanded uncertainty was also calculated. Results: The expanded uncertainty of CBZ with low (7.46 ng·ml-1) and high (745 ng·ml-1) levels was 0.410 ng·ml-1 and 33.400 ng·ml-1, respectively (P=95%, k=2). Conclusion:The uncertainty in CBZ determination in human plasma by HPLC-MS/MS is mainly caused by recovery, sample prepara-tion and matrix effect for low concentration, and by sample preparation and repeatability for high concentration.
7.Application of LC-MS/MS Method for the Determination of Carbamazepine in Human Plasma and Exter-nal Quality Assessment
Shenghui MEI ; Li YANG ; Weixing FENG ; Zhigang ZHAO ; Leting ZHU
China Pharmacy 2016;27(8):1044-1047
OBJECTIVE:To establish and validate the method for the determination of carbamazepine (CBZ) in human plas-ma,and to apply the method for external quality assessment. METHODS:After precipitated with acetonitrile,the plasma sample was determined by LC-MS/MS. Using loratadine as internal standard,the determination was performed on Kromasil C18 column with mobile phase consisted of water (containing 0.1% formic acid)-acetonitrile (gradient elution) at flow rate of 0.6 ml/min and column temperature of 40 ℃. The ion transitions under MRM mode by ESI+ ionization were performed at m/z 237.1→194.0 and m/z 383.1→267.0 for CBZ and internal standard,respectively. RESULTS:The linear range of CBZ were 5-1 000 ng/ml (r>0.998). The limit of quantitation was 5 ng/ml. RSDs of inter-day and intra-day were 1.00%-6.42%;relative deviation were -6.93%-0.32%. The external quality assessment of 5 samples were 679.0,475.0,104.0,29.2 and 26.2 ng/ml,respectively. The pass rate of assess-ment result was 100%. CONCLUSIONS:The method is sensitive,accurate and specific. The method is applicable for the plasma concentration determination and external quality assessment of CBZ.
8.Uncertainty Evaluation of the Determination of Lamotrigine in Human Plasma by LC-MS/MS
Li YANG ; Leting ZHU ; Weixing FENG ; Zhigang ZHAO ; Shenghui MEI
China Pharmacist 2016;19(5):854-858
Objective:To evaluate the uncertainty in the determination of lamotrigine(LTG)in human plasma by LC-MS/ MS. Methods:The uncertainty sources in the determination of LTG were analyzed and the uncertainty was evaluated and combined. Re-sults:The expanded uncertainty of LTG at low(0. 050 4 μg· ml - 1 )and high(1. 27 μg· ml - 1 )concentrations was 0. 005 18 μg· ml - 1 and 0. 066 4 μg· ml - 1 ,respectively(P = 95% ,k = 2). Conclusion:The uncertainty in the determination of LTG in human plasma by LC-MS/ MS is mainly caused by the protein precipitation recovery,matrix effect and sample preparation at low concentration, and by the matrix effect,sample preparation and repeatability at high concentration.
9.Interventional treatment of intracranial arteriovenous fistula in infants
Juming YU ; Guoping FAN ; Weixing ZHONG ; Ming ZHU
Journal of Interventional Radiology 2006;0(08):-
Objective To evaluate the efficacy and safety of embolization therapy with NBCA for intracranial arteriovenous fistula (AVF) in infants. Methods Four patients with cerebral arteriovenous fistula were reported, including 3 males and 1 female with nonspecific symptoms and signs, and the diagnosis was made by DSA. Three of them were treated by embolization therapy with NBCA. Results Three of the cases were treated by NBCA, neither death nor complication occurred. Conclusion Intracranial AVF is rare in childhood. Endovascular treatment with NBCA is effective and safe, but the long-term effect has to be comfirmed by follow-up study. (J Intervent Radiol, 2006, 15: 451-452)
10.The Exploration of Value of Loss of Digitations of Hippocampal Head in Diagnosis of Hippocampal Sclerosis
Wenhua LI ; Tianzhen SHEN ; Jinyong ZHU ; Weixing ZHONG
Journal of Practical Radiology 2001;0(06):-
Objective To explore the significance and value of loss of digitations of hippocampal head in diagnosis of hippocampal sclerosis.Methods Eighteen patients with hippocampal sclerosis comfirmed by histopathological examination and 18 cases to be matched control group were examined by MRI . The digitations,atrophic change and abnormal signals of hippocampal head were evaluated retrospectively.Results Of 18 patients with hippocampal sclerosis, loss of digitations was seen in 16 cases, poorly visible in 1 case and exist in 1 case. The sclerotic hippocampal heads all had atrophic change and were hyperintensity on T_2-weighted and FLAIR MR imagings. No loss of digitations were seen in the opposite side of the hippocampal sclerosis and all hippocampal heads in control group.Conclusion The loss of digitations of hippocampal head is a sensitive indicator for the diagnosis of hippocampal sclerosis.