1.Efficacy of Prolene 3D patching in tension-free hernioplasty for femoral hernia via femoral approach
Chinese Journal of General Practitioners 2014;(6):488-489
A total of 114 cases of femoral hernia undergoing 3D Prolene patching via femoral approach were examined for duration of surgery , length of stay , recurrence , postoperative pain and complications.Among them, 53 cases received both pre-and post-operative Doppler ultrasonic examinations.The vein thrombus ,diameter and flow rate of femoral vein were observed to compare with the pre-operative data to learn whether it had difference or not.The operative duration was 13.3 minutes.There was no event of recurrence ,compression,stricture or thrombosis of femoral vein.
2.Polymorphisms of the thymidylate synthase gene promoter in primary colon cancer and its relationship with clinical pathological parameters
Chinese Journal of Digestion 2001;0(01):-
Objective To investigate the relationship between polymorphisms in the thymidylate synthase promoter enhancer region(TSER) and clinical pathological characteristics of primary colon cancer.Methods TSER polymorphisms and thymidylate synthase(TS) protein were detected by PCR and immunohistochemical staining respectively in primary foci.Results There were three genotypes of TSER including homozygous with double tandem repeats(2R/2R),homozygous with triple tandem(repeats)(3R/3R) and heterozygous with both alleles(2R/3R)in 68 cases of colon cancer(6,40,22 cases respectively).The ratio of 3R/3R was significantly higher in stage of Dukes C than stages in Dukes B and Dukes A.(Dukes A16%;Dukes B30%;Dukes C 93%,?~2=28.56,P
4.Correct measurement of the posterior wall size of adult male inguinal hernia used for herniorrhaphy
Chinese Journal of Tissue Engineering Research 2017;21(6):957-961
BACKGROUND:The mesh size used for herniorrhaphy mainly depends on clinicians' experience, which is less reliable. OBJECTIVE:To obtain the mesh size by measuring the posterior wall of inguinal hernia in Chinese adult men undergoing Rutkow surgery, and to assess the postoperative effect. METHODS:The posterior wall size of inguinal hernia in 180 Chinese adult male patients undergoing tension-free hernioplasty was measured, and then the optical mesh size was calculated. All patients were equivalently randomized into two groups, followed by subjected to Rutkow surgery according the calculated mesh size (experimental group) or subjective size (control group). Clinical indexes, the incidence of complications and recurrence rate were compared between groups. RESULTS AND CONCLUSION:The distance of pubic tubercle to internal oblique inguinal ligament starting point was (6.03±0.58) cm;the vertical distance of the highest point on the edge of the arcuate to inguinal ligament was (3.02±0.32) cm;therefore, the length of mesh should be larger than (13.04±0.74) cm, and width larger than (5.88±0.52) cm. The time of off-bed, dieting and hospitalization in the experimental group were significantly less than those in the control group (P<0.05);the time of operation and recovery of normal activities showed no significant difference between groups (P>0.05). The rates of postoperative complication and recurrence in the experimental group were significantly lower than those in the control group (P<0.01). These results suggest that after measuring the posterior wall size of inguinal hernia, the Rutkow used for inguinal hernia repair, obtains desired treatment outcomes with low incidence of complications and recurrence.
5.Determination of Lead in Cosmetics by Potential Stripping Voltammetry
Xiuzhen WANG ; Weixing WANG ; Zhaohui GUO
Journal of Environment and Health 1992;0(04):-
Objective To establish a method for determination of lead in cosmetics. Methods Samples were digested. The lead content was detected by isochronous mercury-plating method with the condition of lead cation being enriched for 40 s at -1.20V(vs. SCE). Results The stripping potential peak of lead appeared at - 0. 20 V( vs. SCE) . The detection limit was 0.03 jug Pb. Six parallel determinations of a sample were done with the mean of 3.574mg/ kg and the relative standard deviation of 4. 1% . Recovery rates obtained by standard addition test ranged from 90% -100.5% . Conclusion The method is suitable for detecting lead in cosmetics.
6.Application of Grafting Vessels for Coronary Artery Bypass Grafting
Wan HOU ; Shijie WANG ; Weixing WANG
Journal of Chinese Physician 2001;0(09):-
Objective To summarize the experience of obtaining and maintaining grafting vessels correctly in order to prevent grafting vessels from occlusion and assure the success for myocardial revascularization.Methods The grafting vessels was obtained by the method of "no touch", active anticoagulant therapy and maintaining normal level of blood pressure and blood glucose after operation.Results Stable postoperative hemodynamic parameters and myocardial functional improvement without perioperative myocardial infarction and pectoris angina occurred in 15 patients with coronary heart disease.Conclusions Manipulating carefully and gently by the method of "no touch"and active anticoagulant therapy play an important role in the prevention of grafting vessels occlusion and the success of coronary artery bypass grafting.
7.The Effect of Liquiritin on Body Weight and Behavior of Depressive Rats
Zhiyu ZHAO ; Weixing WANG ; Hongzhu GUO
Chinese Mental Health Journal 2002;0(12):-
Objective:To observe the effect of liquiritin on body weight and behavior in depression model rats.Methods:Seventy-two male Sprague-Dawley(SD)rats were randomly assigned into normal control group,model group(stress+vehicle),fluoxetine group(stress+ fluoxetine)and three liquiritin groups(stress+liquiritin at different dose).The behavior of rats was detected by sucrose consumption test and forced swimming test.Results:The model rats showed significantly lower body weight(429?45/494?37,P
8.Research Progress of Portable Life Support System for Extravehicular Activity Space Suit.
Jing WANG ; Weixing YUAN ; Xiugan YUAN
Space Medicine & Medical Engineering 2006;0(01):-
With the development of space exploration,high performance extravehicular activity(EVA) space suit portable life support system(PLSS) is expected.In this paper,the research progress of PLSS for EVA is introduced.The techniques of CO2 removal system and H2O removal system are key parts of PLSS.These concepts are compared and analyzed.Prospects of development of PLSS are proposed.Those mature,reliable techniques should be adopted for our country.Regenerative PLSS facilities should be investigated simultaneously.
9.Clinical Efficacy of Qingwen Baidu Drink in Treating Sepsis and Its Effect on Cytokine
Jianchun LENG ; Weixing WANG ; Qiaolin LI
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(06):-
0.05), while clinical control rate of the treatment group was better than the control group (P
10.Simulation Research on Performance of Condensing Heat Exchanger in Different Working Conditions
Jing WANG ; Weixing YUAN ; Xiugan YUAN
Space Medicine & Medical Engineering 2006;0(02):-
Objective To provide a more accurate calculation method for design of condensing heat exchanger (CHX) through an in depth discussion about working conditions of the CHX commonly used in temperature and humidity control system of manned spacecraft.Methods With difference of the simplified configuration of CHX,a mathematical model was given.Specifically,the log-mean temperature difference (LMTD) method was used in dry conditions,while in wet conditions mass and energy conservation equations were used.The set of equations of the model were solved by using the shooting method provided by Matlab/Simulink program.Results The results of working conditions and the performance of heat transfer and dehumidification of CHX were determined.Analysis showed that the simulation model could evaluate performance of the CHX in different work conditions reasonably and the results were close to the physical phenomenon.Conclusion The simulation models are of significance for design and optimization of CHX both in manned spacecraft temperature and humidity control system and in aircraft environmental control system.