2.Study on the Quality Standard of Huoxuesan
Ying ZHAO ; Fuqiong ZHOU ; Weina ZHU ; Wen LI ; Xuanzhong TAN
China Pharmacy 2016;27(15):2114-2116
OBJECTIVE:To establish the quality standard of Huoxuesan. METHODS:Microscopic identification method was adopted for the qualitative identification of Rhizoma pinelliae,Eupolyphaga seu,Phellodendron amurense and Fructus kochiae in the preparation. HPLC was adopted for the contents determination of phellodendrine,polydatin,jatrorrhizine,berberine and emo-din:the column was ZORBAX Eclipse Plus C18 with methanol-0.1% phosphoric acid(gradient elution)at a flow rate of 0.4 ml/min,the detection wavelength was 240 nm,column temperature was 30 ℃,and the injection volume was 5 μl. RESULTS:Micro-scopic identification map of R. pinelliae,E. seu,P. amurense and F. kochiae was clear. The linear range was 0.159-5.073 μg(r=0.997 4)for phellodendrine、0.149-4.761 μg(r=0.999 9)for polydatin、0.239-7.649 μg(r=0.995 5)for jatrorrhizine、0.165-5.268 μg (r=0.997 2)for berberine、0.012-0.382 μg(r=0.999 9)for emodin;RSDs of precision,stability and reproducibility tests were low-er than 3.0%;recoveries were 98.9%-104.1%(RSD=1.9%,n=6),96.1%-101.7%(RSD=2.5%,n=6),99.6%-105.1%(RSD=2.6%,n=6),90.3%-98.2%(RSD=2.9%,n=6)and 92.9%-96.4%(RSD=2.0%,n=6)respectively. CONCLUSIONS:The es-tablished standard can be used for the quality control of Huoxuesan.
3.Evaluation and comparison of early outcome and corneal biomechanical changes between SMILE-corneal collagen cross linking and SMILE for myopic eyes
Sha JIANG ; Xiaohua LEI ; Weina TAN ; Bao SHU
Chinese Journal of Experimental Ophthalmology 2021;39(5):430-438
Objective:To evaluate early corneal biomechanical change, safety and effectiveness after small-incision lenticule extraction combined with ultraviolet A corneal collagen cross-linking (SMILE-CXL) for myopic eyes and compare with SMILE.Methods:A non-randomized controlled clinical study was performed.Forty-four myopic eyes of 25 patients were included in Hankou Aier Eye Hospital from December 2017 to July 2018.SMILE-CXL or SMILE was carried out for 22 eyes of 12 patients or 22 eyes of 13 patients, respectively, based on the normal posterior surface manifestation of Belin by Pentacam tomography or not.The posterior surface manifestation of Belin was normal in the SMILE group, and the posterior surface of Belin was yellow or red with Corvis biomechanical index and tomographic biomechanical index<0.3 (except keratoconus) in the SMILE-CXL group.The refractive diopter of the eyes was detected before and 6 months after surgery, including spherical diopter, cylindrical diopter and spherical equivalent (SE) with a comprehensive refractometer.The corneal biomechanical parameters of the eyes were detected before and 6 months after surgery with a Scheimpflug-based dynamic tonometry (Corvis ST). The safety index, a ratio of postoperative mean best corrected visual acuity (BCVA) to preoperative mean BCVA, and efficacy index, a ratio of postoperative uncorrected visual acuity (UCVA) to preoperative BCVA, were compared between SMILE-CXL group and SMILE group.BCVA and UCVA were examined using standard chart and converted to logarithm of the minimal angle of resolution (LogMAR) units.This protocol complied with the Declaration of Helsinki and was approved by an Ethics Committee of Hankou Aier Eye Hospital (No.WHS2017052701). Written informed consent was obtained from each patient prior to entering into the cohort.Results:The postoperative UCVA of the eyes in both groups was more than 1.0.There were no significant differences in safety index, efficacy index and SE change between the SMILE-CXL group and SMILE group (all at P≥0.05). At 6 months after surgery, the values of second applanation time (A2T), time from the start until the highest concavity (HC-Time) and DA ratio 2 mm were significantly increased in comparison with before operation in both SMILE-CXL group and SMILE group (all at P<0.05). The changes of A2T, HC-Time and DA ratio 2 mm in the SMILE-CXL group were significantly lowered than those in the SMILE group at the sixth month after surgery ( P=0.001, 0.001, 0.036). The deformation amplitude, maximum corneal velocity during the first applanation (Vin), distance between both non-deformed peaks and integrated radius during the maximum depression were significantly increased, and the central curvature radius at highest concavity, cord length of first applanation, cord length of second applanation, Ambrósio's relational thickness horizontal, stiffness parameter applanation 1 and biomechanical intraocular pressure during the maximum depression were significantly lower at the sixth month after surgery than those before surgery (all at P<0.05). There were no significant differences in the parameters mentioned above between the two groups (all at P<0.05). Conclusions:Compared with SMILE alone, SMILE-CXL shows a comparable safety and efficacy, and better corneal biomechanical properties.
4.Effect of Ding's herb enema prescription on intestinal tissue relateddifferences target in rat colitis using protein array technology
Kang DING ; Hui ZHANG ; Yanyan TAN ; Weina ZHU ; Zhiwei LI ; Wei LU ; Ruiying LI ; Min ZHAO ; Yang DING ; Meng LI ; Shicai HUANG ; Yijiang DING ; Sumin ZHANG
Chinese Pharmacological Bulletin 2017;33(10):1473-1478
Aim To investigate the effect of Ding''s herb enema prescription on intestinal tissue related target in rat colitis induced by dextran sulfate sodium(DSS), and to elucidate the mechanism of Ding''s herb enema prescription in improving the intestinal inflammation and intestinal fibrosis.Methods Rats were fed with 3.5% DSS.The rats were randomly divided into positive drug group, model group, Control group, and Ding''s herb enema prescription group.The positive drug group was treated with mesalazine enema, and Ding''s herb enema prescription group was treated with Ding''s herb enema prescription.The colon mucosa was taken once a day for 6 weeks.The changes of intestinal inflammatory response and intestinal fibrosis related proteins were detected by GSR-CAA-67 antibody protein array, and the differentially expressed proteins were screened out.Results Eight proteins showed statistical differences, including IFN-γ, erythropoietin(EPO), TIMP-2, TIM-1, IL-6, TIMP-1, TNF-α, IL-22 (P<0.05).On the other hand, Ding''s herb enema prescription and mesalazine significantly antagonized the effect of IL-6 and TIMP-1 (P<0.05).The antagonized effect of Ding''s embolization enema on TNF-α and IL-22 was also significant(P<0.05), but mesalazine had no similar effect (P>0.05).Conclusions Ding''s herb enema prescription has the effect of multiple targets, which may improve the intestinal inflammatory response and intestinal fibrosis to achieve the purpose of treatment of ulcerative colitis(UC).