1.Evaluation of the fit of cobalt-chromium crowns fabricated by selective laser melting
Yuqi DANG ; Chunbao ZHANG ; Weina WANG ; Bo GAO
Journal of Practical Stomatology 2015;(3):313-317
Objective:To compare the adaption of cobalt-chromium prostheses fabricated by selective laser melting(SLM)and conven-tional lost wax technique(LW)method.Methods:Cobalt-chromium crowns and three-unit fixed dental prostheses(FDPs)were fabrica-ted by selective laser melting(SLM)or by conventional lost wax technique(LW)respectively(n =5).Marginal fit and internal fit were examined using a light-body silicone.After setting,each silicon film was cut into 2 parts and the thickness of silicon layer was measured at 1 00 ×magnification using a digital microscope,the data of marginal gap(MG)and internal gap(IG)were statistically analysed by ANOVA and SPSS statistical package version 1 7.0.Results:The MG and IG(μm)of cobalt-chromium alloy crowns in EOS M270 group were 42.28 ±1 1 .58 and 1 25.75 ±47.67,in EOS M280 group 46.54 ±8.4 and 1 28.22 ±54.1 8,in LW group 48.66 ±1 2.08 and 1 35.37 ±46.89.The MG and IG(μm)of three-unit FDPs in EOS M270 group were 40.55 ±1 0.04 and 1 33.09 ±39.80,in EOS M280 group 45.36 ±1 0 and 1 38.94 ±50.61 ,in LW group 54.24 ±1 2.04 and 1 51 .87 ±61 .94(P <0.05),respectively.Conclu-sion:The marginal fit of the SLMgroup is superior to that of the LW group and significantly smaller than 1 20 μm of clinical generally accepted standards.SLMsystem can satisfy the clinical requirements.
2.Advances in research on anti-fatigue effect of phytochemicals
Yawen WANG ; Zhonghao XIN ; Weina GAO ; Changjiang GUO
Military Medical Sciences 2016;40(12):1009-1012
Fatigue not only affects people′s lives and work, but also causes diseases .Numerous studies have shown that some phytochemicals can promote body energy metabolism and regeneration , improve physical condition , resist fatigue growth and accelerate fatigue alleviation .This paper reviewed the recent research progress , domestic and overseas , in the anti-fatigue effect of phytochemicals .
4.Effects of oxidative stress on homocysteine metabolism in methionine loading rat hepatocytes
Chao HAN ; Weina GAO ; Jianquan WU ; Jingyu WEI ; Lingling PU ; Jijun YANG ; Changjiang GUO
Chinese Journal of Clinical Nutrition 2012;20(4):238-243
Objective To investigate the effects of oxidative stress on homocysteine and related amino acids metabolism in methionine-loading BRL rat hepatocytes.Methods Cultured BRL rat hepatocytes were divided into control and oxidatively stressed group(100 μmol/L H2O2 was added in culture medium for 2 hours),methionine group(50 mmol/L methionine was added in culture medium for 1 hour),and oxidatively stressed + methionine group(100 μmol/L H2O2 was added in culture medium for 2 hours + 50 mmol/L methionine was added in culture medium for 1 hour).At the end of the experiment,culture fluid was collected.Homocysteine,cysteine,and glutathione were measured by high-performance liquid chromatography,and amino acids were assayed by amino acids analyzer.Results Compared with the control group,the contents of homocysteine[(3.76 ± 0.22)vs.(1.54±0.05)μmol/L,P=0.000]and cysteine[(199.80 ±8.75)vs.(99.11 ±2.47)μmol/L,P=0.000]significantly increased in methionine group,and the contents of homocysteine[(3.84 ± 0.34)vs.(1.54 ±0.05)μmol/L,P=0.000]and cysteine[(200.66±8.60)vs.(99.11 ±2.47)μ mol/L,P=0.000]also increased in oxidatively stressed + methionine group.Compared with oxidatively stressed group,the concentrations of homocysteine[(3.76 ± 0.22)vs.(1.67 ± 0.13)μmol/L,P =0.000],cysteine[(199.80 ± 8.75)vs.(82.64±15.88)μmol/L,P=0.000],and glutathione[(1.50 ±0.14)vs.(1.00 ±0.11)μ mol/L,P=0.011)]significantly increased in methionine group,and the concentrations of homocysteine[(3.84 ± 0.34)vs.(1.67±0.13)μmol/L,P=0.000],cysteine[(200.66±8.60)vs.(82.64±15.88)μmol/L,P=0.000]and glutathione[(1.40 ± 0.30)vs.(1.00 ± 0.11)μmol/L,P =0.028]significantly increased in oxidatively stressed + methionine groups.Compared with the control group,the contents of serine[(12.41 ± 1.51)vs.(24.00 ±2.54)mg/L,P =0.000],glutamate[(33.31 ±0.17)vs.(43.10 ±0.52)mg/L,P =0.000]and glycine[(6.23 ± 0.18)vs.(24.66 ± 10.87)mg/L,P =0.000]significantly decreased,while taurine [(7.99 ±0.16)vs.(6.17 ±0.15)mg/L,P =0.000]increased significantly in oxidatively stressed group.Compared with the oxidatively stressed group,the concentrations of serine[(16.98 ± 0.39)vs.(12.41 ± 1.51)mg/L,P=0.006)]and glutamate[(35.44 ±0.82)vs.(33.31 ±0.17)mg/L,P =0.002]in methionine group significantly increased,while taurine[(3.77 ±0.16)vs.(7.99 ±0.16)mg/L,P =0.000]significantly decreased in methionine group.Compared with the methionine group,the contents of serine[(12.59 ± 0.66)vs.(16.98±0.39)mg/L,P=0.008],glutamate[(30.87±0.60)vs.(35.44±0.82)mg/L,P=0.000]significantly decreased while taurine[(4.37 ± 0.12)vs.(3.77 ± 0.16)mg/L,P =0.001]in oxidatively stressed + methionine group significantly increased.Conclusion Oxidative stress can somehow promote homocysteine production in methionine loading BRL rat hepatocytes,but it is not the main effects.
5.Relationship between vitamin D deficiency and severe pneumonia in children
Gailan GAO ; Jianping PAN ; Weina LI ; Jie LI ; Yan YANG ; Minfeng CHANG
Chinese Pediatric Emergency Medicine 2015;22(4):253-256
Objective To study the relationship between vitamin D deficiency and severe bronchial pneumonia in children. Methods A total of 58 children with severe pneumonia complicated by a lack of vi-tamin D from January 2011 to December 2013 were enrolled in this study,the serum 25-( OH) D3 was detec-ted by the high performance liquid chromatography-tandem mass spectrometry. All the children were random-ly divided into two groups,the vitamin D treatment group( observation group) and without vitamin D treat-ment group(control group),control group received conventional treatment,and the observation group re-ceived vitamin D based on the same treatment with the control group. Results The serum 25-( OH) D3 of the observation group increased significantly( P<0. 01 ) . ( 2 ) The symptoms such as cough, asthma, fever and pulmonary rales in the observation group disappeared more quickly than that of the control group,and the av-erage cure days of heart failure,respiratory failure and encephalopathy as well as the average length of stay in the observation group were less than those of control group,and there were significant differences between two groups(P<0. 01). (3) The total efficiency of the observation group and control group was 96. 42% and 73. 33% respectively,and there was significant difference between two groups(χ2 =6. 693,P<0. 01). (4) Blood oxygen pressure and oxygen saturation of the observer group were significantly improved,CO2 partial pressure decreased obviously, the differences were statistically significant between two groups ( P <0. 01 ) . Conclusion During the treatment periods in children with severe pneumonia,vitamin D supplements could relieve symptoms promptly,shorten the duration,improve the 25-( OH) D3 levels,and vitamin D deficiency may also be the underlying cause of severe pneumonia in children.
6.Effect of Muscle-region Alignment Needling plus Dermal Needle Therapy on the Long-term Therapeutic Efficacy for Post-stroke Upper-limb Spasticity
Baochang ZHANG ; Shukai HAN ; Weina GAO ; Yuna XU ; Hongqiang JIN ; Xinwei YANG ; Weihong YANG
Shanghai Journal of Acupuncture and Moxibustion 2014;(12):1120-1123
ObjectiveTo evaluate the long-term therapeutic efficacy of muscle-region alignment needling plus dermalneedle therapy in treating post-stroke upper-limb spasticity.MethodTotally 488 patients with post-stroke upper-limb spasticity were randomized into a treatment group and a control group, 244 in each group. Besides theessentialrehabilitation treatment, the treatment group was intervened by muscle-region alignment needling plus dermal needle therapy, while the control group was given regular Western medication.Thetwo groups were intervened for 3 weeks and were followed up for 6 months. The neurologic function, Functional Comprehensive Assessment (FCA), and Stroke Speciality-Quality of Life (SS-QOL) were observed for the follow-up study.ResultThe total effective rate was 93.4% in the treatment group versus 61.5% in the control group, and the difference was statistically significant (P<0.05); the neurologic function, FCA score, and SS-QOL score in the treatment group were significantly superior to that in the control group at the end of the follow-up study (P<0.05).ConclusionMuscle-region alignment needling plus dermal needle therapycan produce a content long-term therapeutic efficacy in treating post-stroke upper-limb spasticity.
7.Effectiveness of high frequency oscillation ventilation combined with Sildenafil treatment on newborns with persistent pulmonary hypertension
Shuqiang GAO ; Rong JU ; Xuhong HU ; Zhengwei YE ; Jin MAO ; Weina DU
Chinese Journal of Applied Clinical Pediatrics 2015;30(2):114-117
Objective To explore the effectiveness and adverse effect of high frequency oscillation ventilation (HFOV) combined with Sildenafil (SIL) treatment on newborns with persistent pulmonary hypertension (PPHN).Methods A total of 89 cases of PPHN infants collected from Chengdu Women and Children's Central Hospital from Sep.2010 to Sep.2012 were randomly divided into HFOV group,constant mechanical ventilation (CMV) group,HFOV combined SIL group (HFOV + SIL group) and CMV combined with SIL group (CMV + SIL group).The arterial blood gas,pulmonary artery pressure (PAP) and adverse reactions were monitored before and 3 days after treatment.SNK multiple comparison method andx2 test were performed for data before and after treatment among groups for continuous variables and categorical variables,respectively.Results The levels of pa (O2) [(79.1 ± 13.7) mmHg (1 mmHg =0.133 kPa),(77.9 ±14.6) mmHg,(85.4 ±15.2) mmHg],Sa(O2) [(87.8 ±13.4)%,(88.4±15.6)%,(96.1±15.9)%],pa(CO2)[(42.5±11.3) mmHg,(40.2 ±10.5) mmHg,(35.6 ±8.7) mmHg] and PAP [(31.1 ± 8.1) mmHg,(30.4 ± 9.5) mmHg,(25.8 ± 7.3) mmHg] were all improved significantly in CMV + SIL group,HFOV group and HFOV + SIL group compared with those in CMV group[(69.9 ± 12.3) mmHg,(81.1 ± 14.9)%,(48.1 ±9.5) mmHg,(35.6 ±8.9) mmHg] (F =4.629 3,3.673 2,5.865 3,4.849 5,P <0.05),especially for HFOV + SIL group(P < 0.05).No significant difference in such indicators was observed between CMV + SIL group and HFOV group (P > 0.05).The effective rate in HFOV + SIL group (90%) was the highest among the 4 groups (x2 =7.938,P < 0.05).During the treatment,all neonates have no adverse reaction.Conclusion The combined use of SIL and HFOV might be a more effective and safer method in the treatment of PPHN of neonate.
8.Effect of Auricular Point Sticking on Cerebrovascular Reactivity in Hypertension Patients Studied by Transcranial Doppler
Tingting REN ; Nan GAO ; Weina WANG ; Xianghe SONG ; Lijun DING ; Liangzhi MA
Shanghai Journal of Acupuncture and Moxibustion 2014;(8):698-701
Objective To study the effect of auricular point sticking on the cerebrovascular reactivity in hypertension patients of different stages by using Transcranial Doppler (TCD) technology.Method Three hundred hypertension patients were randomized into a treatment group (auricular point sticking) of 180 cases and a control group (medication) of 120 cases. The cerebral arterial hemodynamic indexes were observed and analyzed by TCD before and after intervention.Result In comparing the improvements of cerebral arterial hemodynamic indexes in stage 1-2 hypertension patients, the treatment group was significantly superior to the control group (P<0.05,P<0.01); in stage 3 hypertension patients, the improvements of cerebrovascular hemodynamics of the treatment group were significantly better than those in the control group (P<0.05,P<0.01).Conclusion Auricular point sticking can improve the cerebrovascular hemodynamics and effectively improve the cerebrovascular reactivity of hypertension patients. TCD can help observe and estimate the cerebral arterial function of hypertension patients, and prevent and intervene in cerebrovascular diseases.
9.Application of Six-minute Walk Test in Acute Stroke Patients
Min LI ; Li WANG ; Mengyu SHI ; Wenxian GAO ; Yufang LIU ; Xuemei WANG ; Weina YU
Chinese Journal of Rehabilitation Theory and Practice 2016;22(9):1097-1100
Objective To apply Six-minute Walk Test (6MWT) in acute stroke patients and analyze the results. Methods From Novem-ber, 2014 to January, 2015, 29 acute stroke patients with multiple or single infarction accepted 6MWT. The distance, distance per minute, blood pressure and heart rate before and after test, adverse events or discomforts during the test were recorded. Weak and fatigue scores were calculated. Results The mean of distance in acute stroke patients was (240.1±17.2) m, that was (46.8±3.3)%of the predicted values in the healthy. Male patients walked (255.4±21.40) m, not different from (214.9±28.4) m in female (t=-1.151, P=0.26). The distance liked to be negatively correlated with age (r=-0.356, P=0.058). The distance was similar in each minute. Weak score was (46.8±3.3)%, fatigue score was mostly between-20 and 20, and no correlation was found between them. Blood pressure and heart rate increased significantly at the end of the test (t>2.476, P<0.05). Few of patients complained mild discomforts. Conclusion 6MWT is safe and suitable for acute stroke patients for physical mobility judgement, but adverse events need to be cared.
10.Study on the fit of titanium alloy removable partial denture framework fabricated by selective laser melting
Yifan LIU ; Weina WANG ; Hai YU ; Rui MA ; Bing WU ; Bo GAO
Journal of Practical Stomatology 2017;33(3):302-305
Objective:To evaluate the fit of titanium alloy removable partial denture framework fabricated by selective laser melting(SLM) technique.Methods:7 Kennedy Ⅲ Ti-6Al-4V removable titanium alloy partial denture frameworks were fabricated by SLM technology.An optical scanner was used to scan the gypsum model adhered with the silicone rubber film obtained by the impression method before and after removal of the film.Geomagic Qualify 2013 software was used to analyze the gap between the model and the tissue surface of the major connector of the framework,the fit of the frame work was evaluated.Results:The overall 3D deviation between the titanium alloy frameworks and the gypsum model was (0.221 9±0.07) mm.Conclusion:The fit of the titanium alloy removable partial denture framework made by SLM technology can basically met the clinical requirements.